MX-ventilation products

Similar documents
REK, LEK, ROK AND LOK

REK, LEK, ROK and LOK

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

Regulation and shut-off damper SPB and SPC

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

Kitchen exhaust fan GLEB

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

Duct Nozzle Diffuser. L e

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Exhaust air diffuser EYMA-2 and air intake device DYMA-1

Carisma The Ultra Quiet Fan Coil

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Particle Filter Box FKU

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

KTI Supply air valve. Product Facts. Product code example. Quick Selection

ROOF FAN ROOFMASTER STEC

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

ROL NOZZLE DUCT ROL-S ADJUSTMENT AND SILENCER UNIT

IrisControlDamper. For Adjustment and Measuring of Airflow.

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

KSOF Fire damper valve

KV sileo 100 M. Circular duct fans. Circular duct fans

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

Performance. Sound Levels. Impellers. Motors. Accessories

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

GDD - Supply Grille. Halton GDD. Supply Grille

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

Particle Filter Box Model FKF

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

For installation into ductwork

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

Round duct diffuser DBB-RR

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

J L I e x h a u s t h o o d

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Round duct grille Model KG-RR

Ceiling Slot Diffuser Model DSX

Floor Swirls Models BZD and SZD

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Plate mounted axial flow fans HXBR / HXTR Series

OPTIVENT Housing HVSA, HVSL

Broad multiplex outlet BF-V...

An agile and compact ambulance

Compact Design BB101 & 93

TW Electric hot-air automatic welding machine. Four wheel drive and belt system assures wrinkle free welding

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

CK, LPK, LPKB. Duct fans with circular connection.

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

ceiling swirl diffuser DQJ

Ceiling Slot Diffuser DSC

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling Slot Diffuser DSC

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Ceiling Swirl Diffuser DQJ

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

ROOFMASTER STEF-ATEX ROOF FAN

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

Radial roof fans - SMART-UL. Application. Stylistics. Structure. Efficiency adjustment. Acoustics

ROOFMASTER STEF-HT ROOF FAN

ILO, OLO, OLE and OLOi

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

NCF fans 50 Hz. Protection class IP 55

Fire dampers ETCE and ETCS TECHNICAL DATA

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

NORDexternal External louvres

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Vent-Axia Sabre Sickle Roof Fans (VSR)

Ceiling diffuser 4DE

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation


HiLTO EC High efficiency heat recovery unit

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

TWINFLOW STDR Product Brochure

Ceiling swirl diffusers

WGA Long throw nozzle grille

Ceiling impulse diffuser Model PIL

Fan coil unit NBS 100/150

Transcription:

MX-ventilation products Technical brochure ENG

Material Weatherproof and impact resistant polypropylene UV protected Solid coloured Reliable and controlled ventilation High-quality and durable materials Easy installation Neat and elegant end result 1. Sewer ventilation pipe 2. Roof fan 3. Radon fan 4. Exhaust pipe. Roof fan 6. Ventilation pole MX-pass-throughs Tight and elegant pass-through Carefully designed shape prevents the accumulation of dirt and debris An excellent fit for the most common roof types Compatible with all Meltex roof fans, exhaust pipes and ventilation pipes MX-exhaust and ventilation pipes Suitable for exhaust air diffusers in air conditioning systems and sewer ventilation Suitable products for 12 mm and 16 mm ventilation ducts and 11 mm sewer pipes Insulation in the products prevents freezing issues MX-roof fans Controlled and efficient mechanical ventilation A suitable capacity class for every need A controlled radon exhaust system MX-ventilation pole For ventilating the base floor in different types of buildings The structure prevents debris, snow and small animals from entering the base floor BASIC COLOURS FOR ROOF PRODUCTS VENTILATION POLE BASIC COLOURS BLACK RR 33-RAL 9 GREY RR 23-RAL 71 BROWN RR 32 RED RR 28/29-RAL 39 BRICK RED RR 7-RAL 84 LIGHT GREY RR 21-RAL 74 BLACK RR 33-RAL 9 GREY RR 23-RAL 71 2

MX-pass-throughs For steep roofs MX-pass-through set for tile roof Suitable for most double-wave roof tiles on the market. The effective width of the passthrough is the same as that of most of the roof tiles on the market. The adjustment discs allow for easy adjustment of the passthrough to suit various tiles. The seals in the pass-through plate are securely attached to the plate, but they can be removed, if necessary. The pass-through set for tile roof includes a pass-through plate, an underlay fastening, fastening screws and installation instructions. The ingenious adjustment discs make installation easier. Colour and product number 212 44 329 783 7831 7832 7833 7834 MX-pass-through set for steel roof Suitable for most tile-patterned steel roofs on the market. A rubber seal that conforms to the roof profile and waterproofs the passthrough is included in the delivery. The rubber seal can be attached to the pass-through plate quickly with two fastening straps. The pass-through set for steel roof includes a pass-through plate, a rubber seal, an underlay fastening, a stencil, fastening screws and installation instructions. The two fastening straps make it possible to mount the rubber seal on the passthrough plate quickly. Colour and product number 177 3 44 783 7836 7837 7838 7839 MX-pass-through set for standing seam roof Suitable for flat, standing seam roofs. The pass-through plate is waterproof thanks to the rubber seal on the lower surface. The order of fastening the screws is marked on the pass-through plate to make installation easier. The pass-through set for standing seam roof includes a pass-through plate, an underlay fastening, a stencil, fastening screws and installation instructions. The pass-through plate shows clearly in which order the screws are fastened. Colour and product number 163 47 293 7831 78311 78312 78313 78314 MX-pass-through for felt roof Suitable for all steep felt roofs. Thanks to the angular shape of the connecting surface, the pass-through and the rubberised bitumen form a waterproof connection to surface felt and underlays. A pass-through plate, a stencil and installation instructions are included in the delivery of the package. MX-fastening for underlay The fastening for the underlay lifts the edges of the underlay up and connects to the roof battens, preventing water from entering the roof's insulation. The fastening for the underlay is included in the delivery of pass-through sets for tile, steel and standing seam roofs. The two fastening lugs make it possible to attach the fastening to the roof battens from the top, which makes installation faster and easier. 17 24 The angular shape of the connecting surface together with bitumen guarantees a strong connection with the Colour felt. and product number 7831 78316 78317 78318 78319 Thanks to fastening from the top, installation is easy. Colour and product number 78368 93 2 634 38 3

Roof angles MAX MX-pass-through set for tile roof MX-pass-through set for steel roof MX-pass-through set for standing seam roof MX-pass-through for felt roof X MAX X 11 mm 36 37 31 31 1 mm 43 44 38 38 12 mm 36 37 31 31 1 mm 4 41 39 39 16 mm 33 36 34 34 Y 1 mm 3 3 X, Y MAX 16 1 mm 38 38 38 MX-exhaust ventilation pipes MX-exhaust ventilation pipe 12 MX-exhaust ventilation pipe 16 27 31 86 73 916 77 Ø12 Ø16 The shape of the cowl efficiently minimises water entering into ventilation ducts. MX-exhaust ventilation pipe 12, colour and product number MX-exhaust ventilation pipe 16, colour and product number 7832 78326 78327 78328 78329 7833 78331 78332 78333 78334 Total pressure, Pa 1 9 8 7 6 4 MX-exhaust ventilation pipe 12 VTT test report No. VTT-S-4474-12 3 2 1 2 4 6 Air flow, l/s 8 1 12 Total pressure, Pa MX-exhaust ventilation pipe 16 VTT test report No. VTT-S-447-12 4 4 3 3 2 2 1 1 2 4 6 8 1 12 14 Air flow, l/s 4

MX-ventilation pipe 11, insulated, and cowl for the MX-ventilation pipe 224 724 9 Ø11 Equipped with a cowl, the MX-ventilation pipe is suitable for natural radon ventilation. 27 MX-ventilation pipe 11, colour and product number 7832 78321 78322 78323 78324 Cowl for the MX-ventilation pipe, colour and product number 78363 78364 7836 78366 78367 MX-roof fans The MX-roof fans with a low pressure loss blow upward. The shape of the roof fans together with a tight pass-through efficiently prevents water from entering the ventilation ducts. There are no pass-throughs on the cover of the motor compartment, which makes the motor compartment more waterproof and protects the motor. The MX-roof fans are easy to maintain. Checking and cleaning the blade wheel occasionally is enough to keep the roof fan in good shape. If necessary, the motor can be easily removed without any tools. The wires are fully enclosed inside the structure and the voltage is cut off automatically when the motor is removed. The inner pipe of the MX-roof fans is made of galvanised steel sheet. The inner pipe of the MX-radon fan is polypropylene; due to fire safety regulations, it cannot be used for residential ventilation. To prevent freezing, we recommend keeping the roof and radon fans on at all times, at least at a minimum speed. The rotation speed can be adjusted by changing the voltage with a thyristor or a step transformer. The integrated power supply does not require any pass-throughs on the outer surface of the product, making it more waterproof. The MX-roof fans and radon fans are FI certified.

MX-roof fan 7/12 27 878 73 MX-roof fan 7/12, colour and product number Total pressure Pt, Pa Total pressure Pt, Pa Ø12 7833 78336 78337 78338 78339 3 2 23V 18V 2 16V 1 14V 12V 1 1V 8V 6V 1 2 3 4 6 7 8 9 1 11 12 13 14 7 6 6 4 4 3 3 2 2 1 1 Flow rates and electric power VTT test report No. VTT-S-661-12 23V 18V 16V 14V 12V 1V 8V 6V 1 2 3 4 6 7 8 9 1 11 12 13 14 Noise levels VTT test report No. VTT-S-661-12 U V 1 1 1 1 1 qv l/s 16, 2,3 32,7 41,3 49,4 LW63 db 6,8 2, 2,4 2,8 2,4 LW12 db 7,7 4,6 2,8 3, 6,6 LW2 db 3, 48, 47,1 49,1 49,7 LW db 4,8 42,4 43,1 43,7 43,3 LW1 db 4,7 37,8 37, 38,9 4,8 LW2 db 33,3 27,8 26,1 27,2 31,2 LW4 db 22,7 19,9 2,1 17,8 18,6 LW8 db 24,8 24,9 2,3 * * LW db 61,2 7, 6,4 7,2 61,6 LWA db(a) 49, 4,1 44,4 4,8 47,7 U V 14 14 14 14 14 qv l/s 2, 41,8 1,7 63,9 8, LW63 db 63,7 6,1 6, 7,6 8, LW12 db 6,6 67, 72,2 73,6 6,3 LW2 db 67,2 63, 62, 63,8 6,2 LW db 9, 2,7 3,7 3,2 3,4 LW1 db 4,,9,9,6 1,7 LW2 db 48,8 43,7 42,6 44,9 48, LW4 db 4, 32,7 31,7 32, 37, LW8 db 33,1 26,8 26,1 26,4 27,8 LW db 7,9 68,9 72,8 74,2 68,9 LWA db(a) 61,2 8,1 6,7 61,8 8,9 U V 18 18 18 18 18 qv l/s 31,8,2 69,9 88,6 11 LW63 db 9,6 8,2 8, 7,8 6, LW12 db 64, 63,2 6,8 61,7 64,6 LW2 db 78,4 7,4 71,8 72,2 78,4 LW db 9,2 9,9 7,9 7,7 6,4 LW1 db 9,2 62, 63,6 6,4 7, LW2 db 2,4 2,2,8 2,6 4,4 LW4 db 43, 43,1 42, 44,2 47, LW8 db 38,1 37, 36,6 36,4 38,3 LW db 78,8 76,1 73, 73, 78,8 LWA db(a) 7,3 68,3 66,2 64,6 7,2 6

MX-roof fan 12/12 27 878 73 MX-roof fan 12/12, colour and product number Total pressure Pt, Pa Power input of the roof fan, W Ø12 7834 78341 78342 78343 78344 Flow rates and electric power VTT test report No. VTT-S-669-12 3 23V 2 18V 2 16V 1 14V 1 12V 1V 8V 6V 1 2 3 4 6 7 8 9 1 11 6 4 4 3 3 2 2 1 1 23V 18V 16V 14V 12V 1V 8V 6V 12 13 1 2 3 4 6 7 8 9 1 11 12 13 Noise levels VTT test report No. VTT-S-669-12 U V 1 1 1 1 1 qv l/s 16,7 24,9 36,9,6 62,3 LW63 db 7,2 63,7 8, 9, 9,2 LW12 db 73,9 61, 62,3 9, 9, LW2 db 6,2 7, 7,1 3,1 4,3 LW db 1,7 49,3 47,8 48,,3 LW1 db 46,2 43, 4,8 42,4 4,2 LW2 db 39, 3,6 31, 32,8 37,9 LW4 db 29,9 2,6 21,7 21,6 23,9 LW8 db 22,7 * * * * LW db 7,6 66,4 64,6 62,9 63,3 LWA db(a) 61,4 2,7 2,1,3 2,1 U V 14 14 14 14 14 qv l/s 24,4 3,9 2, 72,2 88,7 LW63 db 73,1 74,1 68,7 61,8 63,6 LW12 db 74,1 71, 67, 68,4 66, LW2 db 76,7 69, 7,2 68,2 68,1 LW db 62, 9,8 7, 7, 7, LW1 db 7,6 6,6 6,4,1 7,2 LW2 db 2, 49,6 47,8 49,9 1,9 LW4 db 42,7 39,9 36,1 3,6 38,9 LW8 db 31,7 28,7 2, 24,8 27, LW db 79,8 76,8 73,8 72, 71,6 LWA db(a) 69, 63, 62,7 62, 62, U V 18 18 18 18 18 qv l/s 3,8 48,1 66,1 92,3 114 LW63 db 81,2 77,4 7, 64,6 64,1 LW12 db 77,6 7,7 73,6 7, 72, LW2 db 7, 79,1 81,2 76,1 79,8 LW db 6,2 64,4 63, 62,3 62,3 LW1 db 61,4 62,6 61,8 61,9 62,7 LW2 db 6,6,,2,3 7,1 LW4 db 47,7 46, 44,6 4,9 49,7 LW8 db 37,6 3,3 33,2 32,6 3, LW db 83,6 82, 82,3 77,6 8,7 LWA db(a) 7,1 72,1 73,2 69,1 72,2 7

MX-roof fan 12E/12, silenced 31 Silencer in the body 92 77 MX-roof fan 12E/12, colour and product number Total pressure Pt, Pa Power input of the roof fan, W Ø12 7834 78346 78347 78348 78349 3 2 2 1 23V 2V 18V 16V 14V 1 12V 1V 8V 6V 1 2 3 4 6 7 8 9 1 11 12 13 14 1 6 7 6 4 4 3 3 2 2 1 1 Flow rates and electric power VTT test report No. VTT-S-6661-12 14V 12V 1V 8V 6V 23V 2V 18V 16V 1 2 3 4 6 7 8 9 1 11 12 13 14 1 Noise levels VTT test report No. VTT-S-6661-12 U V 1 1 1 1 1 qv l/s 17,8 34,6 44,1 4,6 72,8 LW63 db 63,4 9,3 1,4 2,2 4,4 LW12 db,9, 49,3 1,4, LW2 db 47,8 46,4 44,8 4,2 48,4 LW db 38,4 41,2 31,4 32,4 36, LW1 db 2,2 2,8 19,2 2,9 27, LW2 db 1,4 12,9 * * 1,9 LW4 db * * * * * LW8 db * * * * * LW db 64,2 6,9 4,1,3 8,2 LWA db(a) 44,3 43,9 37,9 39,1 42,7 U V 14 14 14 14 14 qv l/s 32,6 47,8 62,4 79,7 13 LW63 db 67, 62, 6, 9,2 8,1 LW12 db 63,9 8,2 8,1 9,2 62,9 LW2 db 63,2 6,4 6,3 6, 9, LW db 42,1 39,9 41,2 42,4 4,7 LW1 db 32,7 36,9 37, 33,1 38, LW2 db 18,1 18, 18,3 22, 31, LW4 db * * 11,6 19,8 23, LW8 db * * * * 17,1 LW db 69,8 64,3 63,2 63,2 6, LWA db(a) 4, 48,4 48, 48,6 2,2 U V 18 18 18 18 18 qv l/s 4,9 6, 73,8 14 122 LW63 db 68,8 63,1 61,6 61,1 61, LW12 db 71,7 6,8 63,8 6,2 66,1 LW2 db 63,4 6,2 6,6 61,7 63,2 LW db 46,4 4,6 46,6 48,3, LW1 db 3,8 36,6 46,7 44,6 43,6 LW2 db 24,4 23,6 24,3 32, 37, LW4 db 22,4 21,1 21,3 26,1 3, LW8 db 21, 17,4 17, 22, 2,8 LW db 73,9 68,4 67,1 67,9 68,9 LWA db(a) 7,7 3,3 4,1 4,9 6,1 8

MX-roof fan 18E/16, silenced 31 Silencer in the body 913 77 MX-roof fan 18E/16, colour and product number Total pressure Pt, Pa Power input of the roof fan, W Ø16 783 7831 7832 7833 7834 3 2 2 1 2V 18V 16V 23V 14V 1 12V 1V 8V 6V 1 2 3 4 6 7 8 9 1 11 12 13 14 1 16 17 18 19 9 8 8 7 7 6 6 4 4 3 3 2 2 1 1 Flow rates and electric power VTT test report No. VTT-S-6664-12 23V 2V 18V 16V 14V 12V 1V 8V 6V 1 2 3 4 6 7 8 9 1 11 12 13 14 1 16 17 18 19 Noise levels VTT test report No. VTT-S-6664-12 U V 1 1 1 1 1 qv l/s 1,9 27,7 4,,2 8,6 LW63 db 9,6 3, 1, 49,3 2,6 LW12 db 9,3,3 1,6,9 2,8 LW2 db,6 44,7 43,1 44,1 48,2 LW db 38, 32,7 32,9 33,9 38,1 LW1 db 28,1 23,3 23,7 24,1 28,6 LW2 db 1, * * * 11,7 LW4 db * * * * * LW8 db * * * * * LW db 62,8 7,6 4,9 3,8 6, LWA db(a) 46,3 41,2 39, 39, 42,6 U V 14 14 14 14 14 qv l/s 23,2 4,6 9,6 84,7 116 LW63 db 67,8 62, 2,6 2,6 6, LW12 db 67,1 9,9 2,3 2,6,8 LW2 db 63,6 6,4 1, 1,9 8,1 LW db 49,4 43,4 41, 42,9 46,6 LW1 db 38,1 31,8 3, 31,8 36,7 LW2 db 18, 11,7 1, 1,4 26,3 LW4 db 21, 1,6 * * 2,9 LW8 db 19, * * * * LW db 71,3 6,1 6,9 7,3 61,8 LWA db(a) 7, 49,8 44, 4,,9 U V 18 18 18 18 18 qv l/s 29, 3,2 8,2 17 18 LW63 db 72,1 66, 8,8 7, 62,1 LW12 db 73,3 66,1 8,1 8,4 61,3 LW2 db 7,2 6,1 7,1 7,6 61,9 LW db 6,9 1,2 48, 49,8 3, LW1 db 4,7 4,9 37,9 38,7 4,1 LW2 db 24,8 2,6 18, 23,9 37, LW4 db 28,4 23, 21, 22, 34,8 LW8 db 27,7 22,6 19, 21,6 26,7 LW db 76,9 7,6 63, 62,8 66,8 LWA db(a) 63,4 8,2 1,1 1,9 6,4 9

MX-radon fan 11 88 73 Colour and product number Radon fan pressure, Pa Power input of the radon fan, W Ø11 783 7836 7837 7838 7839 3 23V 2 2V 2 18V 16V 1 1 14V 12V 1V 8V 6V 1 2 3 4 6 7 8 9 1 11 12 6 4 4 3 3 2 2 1 1 Flow rates and electric power VTT test report No. VTT-S-661-12 23V 2V 18V 16V 14V 12V 1V 8V 6V 1 2 3 4 6 7 8 9 1 11 12 Noise levels VTT test report No. VTT-S-661-12 U V 8 8 8 8 8 qv l/s 12, 17,8 24,8 32,3 36,4 LW63 db 1,8 1,3,2 4,4 48, LW12 db 6,,6 3, 3,6 3,3 LW2 db 48,2 44, 44,8 47,1 47, LW db 44,4 43,8 43,2 43,1 42,9 LW1 db 4,9 39,4 4,6 41,4 41,7 LW2 db 2,2 21,6 21, 21, 21,1 LW4 db 19,8 2,2 2,3 2,2 23,7 LW8 db 18,1 16,6 * * * LW db 8, 7,,7 7,7,7 LWA db(a) 46,4 4,2 4,2 46, 4,9 U V 12 12 12 12 12 qv l/s 21,1 3,8 43,9 3,7 62,1 LW63 db 6,3 3,9 1, 4,,1 LW12 db 72,2 61, 63,7 68,3 69, LW2 db 67,,1 4,8,9 7, LW db 4,7,8 2,7 3,2 3,1 LW1 db 2,2,1,7,6 1,9 LW2 db 44,1 39,2 37,9 39,1 41,3 LW4 db 32,8 27,7 2,9 26,8 29,7 LW8 db 18,9 21, 2,1 2,3 22, LW db 73,7 63,1 64,9 68,9 69,6 LWA db(a) 62,1 4,3, 7,6 8,4 U V 16 16 16 16 16 qv l/s 28, 4,8 7, 7,7 8,2 LW63 db 9,8,9,3,6 7,1 LW12 db 66,8 62,1 61,9 62,8 63,6 LW2 db 73,7 67,9 68,9 72,1 76,2 LW db 6,4 7,6 7,4 7,9 9, LW1 db 9, 68,1 63,8 8,8 9,4 LW2 db 2,7 1,7 48,,1 2,8 LW4 db 43,7 39,1 38,2 39, 41,9 LW8 db 32,9 28, 27,2 26,9 27,9 LW db 7, 71,8 71, 73, 76,6 LWA db(a) 66,9 68, 6,2 64,3 67,1 1

Electrical and technical specifications Power, W, V Rated current, A Capacitor, uf Speed of rotation, rpm MX-roof fan 7 2 23/ Hz,23 1, 23 MX-roof fan 12 8 23/ Hz,26 2 2 MX-roof fan 12E 8 23/ Hz,26 2 2 MX-roof fan 18E 8 23/ Hz,38 3 2 MX-radon fan 11 2 23/ Hz,23 1, 26 Speed control Thyristor or step transformer Circuit diagram Quick selection of MX-roof fans 3 2 Total pressure Pt, Pa 2 1 1 1 2 3 4 6 7 8 9 1 11 12 13 141 16 17 18 19 MX-roof fan 7/12 MX-roof fan 12E/12 MX-roof fan 12/12 MX-roof fan 18E/16 Quick selection of MX-roof fans for residential ventilation Dwelling area, m 2 Air change rate, (m 3 /h)/ Air flow, l/s MX-roof fan m 3 <,7 2 MX 7/12 8, 3 MX 7/12, MX 12/12 12, 4 MX 12/12, MX 12E/12 16, 6 MX 12/12, MX 12E/12, MX 18E/16 > 2, 8 MX 18E/16 11

MX-ventilation pole 16 112 13 Ø168 19 38 The add-on for the MX-ventilation pole is an accessory. The add-on raises the ventilation pole by 33 mm, and several add-ons can be connected to gain greater heights. MX-ventilation pole 16, colour and product number 7836 78361 78362 37 MX-ventilation pole add-on 33 mm, colour and product number 78371 78369 7837 19 1 MX-ventilation pole 16 Quick selection of MX-ventilation pole Pressure loss, Pa 2 2 1 1 Area, m 2 Pcs, side of the building Pcs, total 8 3 6 12 4 8 16 1 2 6 12 The calculation is only indicative. In addition, the shape of the building and other structural features that have an effect on the air flow must be taken into account. 1 1 2 2 3 3 4 4 Amount of air, l/s Meltex Oy Plastics Taivaltie 2 FI-161 Vantaa Finland Tel. +38 2 777 7 Email sales@meltex.fi www.meltex.fi MX_ventilation_products_tech_ENG 1/212