Symmetra PX. 20 kw 208 V. Technical Specifications 01/2016.

Similar documents
Symmetra PX. Technical Specifications 07/

EPS Technical Specifications 06/2015.

Technical Specifications. Symmetra PX kw 208 V

Galaxy VM. Battery Breaker Box Installation 09/

Symmetra PX 20 kw. InfrastruXure 208 V. Installation 01/

Symmetra PX 96 and 160 kw

Galaxy Receiving and Unpacking 09/

Galaxy VX. 380 V, 400 V, 415, and 440 V UPS System Technical Specifications 12/

Galaxy : kva 380/400/415 V 3: kva 220/230/240 V. Technical Specifications 04/

Installation Power Management Unit Battery Cables and Battery Harness

Symmetra PX kw 208 V. Installation 01/

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

Technical Specifications

Galaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016.

Galaxy Technical Specifications 05/

Installation Guide. Marine Filter SURT023M SURT024M

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Galaxy Installation 08/

Galaxy VX. 480 V UPS System Technical Specifications 07/

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Galaxy 300 Battery Breaker Kit G3HTBKIT1

Galaxy 300. Technical Specifications 06/

Galaxy kva 380/400/415 V UPS Technical Specifications 08/2017.

Broadband PowerShield. CP27U Models. User Manual

Symmetra PX with Maintenance Bypass

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Installation and Operation

Symmetra PX. 250/500 kw 400/480 V Single and Parallel Installation 07/

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Smart-UPS VT kva 208/220 V Single and Parallel Installation. With Batteries 11/2016.

Easy UPS 3S with Internal Batteries

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Easy UPS 3M. Operation 01/

PowerValue 11/31 T kva

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

User Manual Easy UPS On-Line SRVS Series Rack-Mount 1000VA, 2000VA, 3000VA

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

SUA1000I-IN / SUA1500I-IN 230 VAC

APC Smart-UPS 2200/3000 VA 230 VAC. Uninterruptible Power Supply

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

User Manual Easy UPS On-Line SRV Series 1000VA, 2000VA, 3000VA

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower 100/120/230 Vac. 500 VA Tower 100 Vac

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Single and Parallel Installation

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Operation Manual. Smart-UPS Uninterruptible Power Supply. 1000/1500/2200/3000 VA 220 Vac. Rack-Mount 2U

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

User Manual. Smart-UPS. Uninterruptible Power Supply. 1000/1500 VA 100/120/230 Vac. 750XL/1000XL VA 120/230 Vac. Tower

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Illuminator Series CR NEMA 3R

TECHNICAL DATA SHEET KVA UPS Systemss

User Manual Smart-UPS On-Line SRC1KI-IN, SRC1KUXI

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

Operation Manual. Smart-UPS. Uninterruptible Power Supply. Rack-Mount 1U. 1200/1500 VA 100/120/230 Vac

Installation and Operation

10 Year Limited Warranty

Features and Benefits

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Symmetra PX. 48, 96, and 160 kw 400 V 100 kw 208 V. Operation 09/

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

EFFEKTA Power Supplies

Electrical Installation

SecureUPS On-Line 120V AC Output, 1300VA

Sola/Hevi-Duty S3K Series Mini-Tower UPS

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

G3PE-Single-phase. Solid State Relays for Heaters

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Operation Manual. Smart-UPS Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA 100/120/230 Vac. 500 VA 100 Vac. Tower

AIS and 40 kva 400 V. Site Preparation and Installation Manual

AIS 5000 UPS kva 480 V. Installation Manual

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

StormPro BA Series Sump Pump

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

II DISTRIBUTION & SUBSTATION TYPE C

Installation and Operation

High Performance Output Sine Wave Filter Installation, Operation, and Maintenance Manual

Galaxy 300 and Galaxy 300i

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

POWER kva

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Liebert PowerSure PSI UPS

Transcription:

Symmetra PX 20 kw 208 V Technical Specifications 01/2016 www.schneider-electric.com

Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to in this guide are the sole property of Schneider Electric SA and its subsidiaries. They may not be used for any purpose without the owner's permission, given in writing. This guide and its content are protected, within the meaning of the French intellectual property code (Code de la propriété intellectuelle français, referred to hereafter as "the Code"), under the laws of copyright covering texts, drawings and models, as well as by trademark law. You agree not to reproduce, other than for your own personal, noncommercial use as defined in the Code, all or part of this guide on any medium whatsoever without Schneider Electric's permission, given in writing. You also agree not to establish any hypertext links to this guide or its content. Schneider Electric does not grant any right or license for the personal and noncommercial use of the guide or its content, except for a non-exclusive license to consult it on an "as is" basis, at your own risk. All other rights are reserved. Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this publication.

20 kw 208 V Table of Contents Important Safety Information...5 Safety Precautions...6 Technical Data...8 Model List...8 Input Power Factor...8 Efficiency...8 Efficiency Curve 10 kw...8 Efficiency Curve 20 kw...8 Batteries...9 Efficiency DC to AC...9 Battery Runtimes...9 End of Discharge Voltage...10 Battery Material Safety Data Sheet...10 Communication and Management... 11 Network Management Card AP9630CH... 11 Compliance... 11 Facility Planning...12 AC Input Specifications...12 AC Bypass Specifications...12 AC Output Specifications...12 Battery Specifications...13 Fuses and Breakers...13 Protection Type and Rating...13 System DC Input Protection...14 Wiring...14 Wraparound Bypass Configuration / Rating...14 Distribution...14 Recommended Cable Sizes...14 Torque Specifications...14 Emergency Power Off (EPO)...15 EPO Type...15 EPO Wiring...15 Physical...15 Weight and Dimensions...15 Shipping Weight and Dimensions...15 Clearance...16 Environmental...16 Heat Dissipation...17 Drawings...18 Single Feed with MBP One Line Diagram...18 Options...19 Hardware Options...19 Symmetra Power Module...19 Symmetra Battery Systems...19 Optional Management Devices...19 Configuration Options...19 Schneider Electric Limited Factory Warranty...20 990 4640B 001 3

Important Safety Information Important Safety Information 20 kw 208 V Read these instructions carefully and look at the equipment to become familiar with it before trying to install, operate, service or maintain it. The following safety messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of this symbol to a Danger or Warning safety message indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages with this symbol to avoid possible injury or death. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. Failure to follow these instructions will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. Failure to follow these instructions can result in death, serious injury, or equipment damage. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Failure to follow these instructions can result in injury or equipment damage. NOTICE NOTICE is used to address practices not related to physical injury. The safety alert symbol shall not be used with this type of safety message. Failure to follow these instructions can result in equipment damage. Please Note Electrical equipment should only be installed, operated, serviced, and maintained by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to the construction, installation, and operation of electrical equipment and has received safety training to recognize and avoid the hazards involved. 990 4640B 001 5

20 kw 208 V Important Safety Information Safety Precautions DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH The product must be installed according to the specifications and requirements as defined by Schneider Electric. It concerns in particular the external and internal protections (upstream circuit breakers, battery circuit breakers, cabling, etc.) and environmental requirements. No responsibility is assumed by Schneider Electric if these requirements are not respected. After the UPS system has been electrically wired, do not start up the system. Start-up must only be performed by Schneider Electric. Failure to follow these instructions will result in death or serious injury. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH The UPS System must be installed according to local and national regulations. Install the UPS according to: IEC 60364 (including 60364 4 41- protection against electric shock, 60364 4 42 - protection against thermal effect, and 60364 4 43 - protection against overcurrent), or NEC NFPA 70 depending on which one of the standards apply in your local area. Failure to follow these instructions will result in death or serious injury. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH Install the UPS system in a temperature controlled area free of conductive contaminants and humidity. Install the UPS system on a non-inflammable, level and solid surface (e.g. concrete) that can support the weight of the system. Failure to follow these instructions will result in death or serious injury. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH The UPS is not designed for and must therefore not be installed in the following unusual operating environments: Damaging fumes Explosive mixtures of dust or gases, corrosive gases, or conductive or radiant heat from other sources Moisture, abrasive dust, steam or in an excessively damp environment Fungus, insects, vermin Salt-laden air or contaminated cooling refrigerant Pollution degree higher than 2 according to IEC 60664-1 Exposure to abnormal vibrations, shocks, and tilting Exposure to direct sunlight, heat sources, or strong electromagnetic fields Failure to follow these instructions will result in death or serious injury. 6 990 4640B 001

Important Safety Information 20 kw 208 V HAZARD OF OVERHEATING WARNING Respect the space requirements around the UPS system and do not cover the product s ventilation openings when the UPS system is in operation. Failure to follow these instructions can result in death, serious injury, or equipment damage. HAZARD OF EQUIPMENT DAMAGE WARNING Do not connect the UPS output to regenerative load systems including photovoltaic systems and speed drives. Failure to follow these instructions can result in death, serious injury, or equipment damage. 990 4640B 001 7

20 kw 208 V Technical Data Technical Data Model List Symmetra PX 20 kw InfraStruXure 20kW, 208V Input Power Factor Input Power Factor 0.99 @ full load Efficiency System 25% load 50% load 75% load 100% load Symmetra PX 10 kw 91.6% 93.8% 94.2% 94% Symmetra PX 20 kw 92.5% 94.3% 94.6% 94.3% Efficiency Curve 10 kw Efficiency Curve 20 kw 8 990 4640B 001

Technical Data 20 kw 208 V Batteries Efficiency DC to AC DC-AC at nominal battery voltage 94% Minimum from 75% to Full load when configured as 20kVA n+0 Battery Runtimes 4.5 minutes Two battery shelves: @ 0.1 PF load 8 minutes Two battery shelves: @ 0.7 PF load (SMPS load according to EN50091 3/EIC62040 3) 13 minutes Four battery shelves: @ 0.1 PF load 21 minutes Four battery shelves: @ 0.7 PF load (SMPS load according to EN50091 3/EIC62040 3) 3 hours To 90% capacity after full discharge External Battery/Extended Runtime Options Up to four modular battery cabinets can be added 10 kw Curve A B C D E Part Number(s) SY10K SY10K + (1)SYBT4 SY10K + (2)SYBT4 SY10K + (3)SYBT4 SY10K + (1)SYCFXR8 8 990 4640B 001 9

20 kw 208 V Technical Data 20 kw Curve A B C D E Part Number(s) SY20K SY20K + (1)SYBT4 SY20K + (2)SYBT4 SY20K + (1)SYCFXR8 8 SY20K + (2)SYCFXR8 8 End of Discharge Voltage Battery Material Safety Data Sheet NOTE: For Material Safety Data Sheet (MSDS), go to the Knowledge Base http:// www.apc.com/site/support/us/en/faq/ and type MSDS to get the latest MSDS information. 10 990 4640B 001

Technical Data 20 kw 208 V Communication and Management Interface port DB-9 RS-232, RJ-45 10 Base-T Ethernet for web/snmp, Internal Modem for out of band management Smart Slot Interface Quantity 2 Management software included Control panel Audible alarm PowerChute Symmetra Bundle Multi-function LCD status and control console Alarm when on battery: distinctive low battery alarm: configurable delays Network Management Card AP9630CH This UPS is equipped with two Smartslots which enables the use of two Network Management Cards (NMC). By default, the UPS is shipped with the AP9630CH NMC. AP9630CH Network Management Features: Browser accessible View the user interface with a browser Notification Be notified of problems to ensure that crucial situations are dealt with in a timely manner Data logging Identify problematic trends before they escalate or export the data log for analysis Event logging Pinpoint the timing and sequence of events leading up to an incident with the event log PowerChute Network Shutdown compatible Reliable network-based shutdown of multiple servers on single or parallel UPS installation StruxureWare Data Center Expert compatible An IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network Compliance Regulatory Approvals Standard Warranty UL Listed per UL 1778, CSA Certified per standard CSA 107.1, FCC Verified Class A per standard FCC 47 CFR Part 15, IEC 61000-4-2 level 3, performance criteria B, IEC 61000-4-4 level 2, performance criteria A, IEC 1000-4-5 test voltages double those required for class 3, IEC 61000-4-3 level 2, performanc criteria A 1 year on-site repair or replace with factory authorized Start-Up 990 4640B 001 11

20 kw 208 V Facility Planning Facility Planning AC Input Specifications Connection type 3PH + N + PE Nominal input current 1 (A) 61.3 Maximum input current 2 (A) 70.9 Input current limitation 3 (A) 89.4 Overload (A) Walk-in duration Input power factor Total harmonic distortion (THDI) 115.0 A for 30 seconds (based on 150% overload on output) 15 seconds (On retransfer from input to battery, RMS current will linearly ramp in for 10 seconds) 0.99 at full load < 6% at full load Nominal input voltage (V) 208 Input voltage range (V) 166 4 240 5 Input frequency (Hz) 40 70 (Outside of this range, the UPS will operate from battery power) Maximum short-circuit withstand (ka) 30 AC Bypass Specifications Connection type 3PH + N + PE Input frequency (Hz) 40 70 Nominal input current (A) 55.5 Input voltage range (V) 183 233 Output current at overload (A) 69.4 A at 125% load 555.1 A 1000% load for 500 ms AC Output Specifications Output voltage Connection type Overload capacity 208 V 3PH + N + PE or 3PH + PE 150% for 30 seconds (normal operation) 150% continuously for 30 seconds (battery operation) 100% continuously (bypass operation) 1000% for 500 milliseconds (bypass operation) Crest factor 2.7 6 Load power factor 0.5 to 1.0 Output voltage dynamic load response +/-5 % (For load step 0% to 100% or 100% to 0%. Recovery back to steady state: < 60ms) 1. Current that flows at nominal mains with batteries fully charged 2. Current that flows at nominal mains with charging batteries 3. The maximum continuous input current limit that can be drawn at low mains with charging batteries 4. At less than full load, the UPS will operate from mains/utility power to lower voltages 5. Above 240 V, the UPS will operate from battery power 6. No limit on applied crest factor, but the UPS regulates it down to 2.7 12 990 4640B 001

Facility Planning 20 kw 208 V Total harmonic distortion (THDU) Nominal output voltage (V) < 2% (100% resistive load) < 6% (Computer load as defined by EN50091-3/ IEC 62040-3) 208 V Output voltage range (V) 205.9 V 1% to 210.1 V +1% Output frequency (on line, in bypass) 7 Synchronized to input over the range 57 Hz 63 Hz Output frequency battery operation (Hz) 50/60 Slew rate (Hz/s) Programmable to 0.25, 0.5, 1, 2, 4, and 6 Battery Specifications Battery type Maintenance-free, sealed, lead-acid battery with suspended electrolyte leakproof Nominal voltage (VDC) +/- 192 Float voltage (VDC) +/- 219 End of discharge voltage (VDC) 8 +/- 158 (96 cells at 1.65 V) Temperature compensation -320mV per C (For temperatures greater than or equal to 20 C) 0mV per C (For temperatures less than 20 C) Battery charging 9 (kw) 2 (N system 2 power modules ) Maximum charging power 9 (kw) Recharge time DC Ripple current 10 External battery input Full load DC input current External battery input Maximum DC input current 3 (N+1 system 3 power modules) 3 hours to 90% capacity after full discharge <0.05 C 55.4 A at +/-192 V 66.5 A at end of discharge +/-160 V Fuses and Breakers NOTE: The UPS unit s withstand rating is 30,000 symmetrical Amps RMS Protection Type and Rating Condition: The UPS plus the following options (external to the UPS): Input Isolation Transformer Protection Type Notes Present 90 A 3 pole breaker (30k AIC) If available fault current is less than 30 ka, a lower AIC rated breaker may be used. Isolation transformer contains 90 A Class J fuse on primary. Each power module contains 2 pieces of 30 A fuse in parallel on its input. Not present 90 A Class J current limiting fuse Current limiting fuse is required to limit fault current through static switch. Each power module contains 2 pieces of 30 A fuse in parallel on its input. 7. The following ranges can be selected: 40-60 Hz, 47-53 Hz, 49.9-50.1 Hz, 50-70 Hz, 57-63 Hz, and 59.9 60.1 Hz 8. May be higher at less than full load 9. May drop to lower values at low AC Mains 10. In normal operation at fully charged batteries 990 4640B 001 13

20 kw 208 V Facility Planning System DC Input Protection DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH For third party external battery solutions, it is mandatory to install an external MCCB supplied by Schneider Electric containing two 100 A DC breakers for battery isolation. Failure to follow these instructions will result in death or serious injury. Wiring Phase conductor size Terminal lug diameter Notes Mains input 3 AWG THHN Saddle clamp- not stud Wire AWG is recommended, copper, 194 F (90 C) per NEC 310-15 and 310-16 for 104 F (40 C) temperature environment and maximum of 3 current carrying conductors in a raceway. Local electrical codes must take precedence. Neutral conductor to be sized equal to phase current #2 AWG recommended. DC input 1/0 AWG 8 mm Recommended PE conductor size is 4 AWG. The PE lug diameter is 0.250 in (8 mm). Wraparound Bypass Configuration / Rating Q1 Q2 Q3 3 Pole 100 A 80% rated breaker 3 Pole 100 A 80% rated breaker 3 Pole 100 A 80% rated breaker Distribution Square D QOB Panel 42 poles 3 Phase Input via back feed 80A breaker mounted in panel Capable of feeding 13 3 pole circuits ATO configurable overhead whips Internal Wiring #4AWG Recommended Cable Sizes Recommended cable sizes 4 AWG THHN 1 inch conduit Torque Specifications Torque for main input terminals (in-lb) 24.6 26.1 PE lug (in-lb) 124 14 990 4640B 001

Facility Planning 20 kw 208 V Emergency Power Off (EPO) EPO Type Normally open dry contact closure or applied 24 VDC. EPO Wiring CL2 or other extra-low voltage wiring in accordance with local electrical codes. Physical Weight and Dimensions UPS Model Weight kg (lbs) Height mm (in) Width mm (in) Depth mm (in) Symmetra PX 20 kw, 208 V 275 (606) 11 2068 (81.4) 597 (23.5) 905 (35.6) Shipping Weight and Dimensions UPS Model Weight kg (lbs) Height mm (in) Width mm (in) Depth mm (in) Symmetra PX 20 kw, 208 V 842.27 (1853) 12 2311 (91) 749 (29.5) 1054 (41.5) 11. Without power or battery modules inside 12. Including battery and power modules 990 4640B 001 15

20 kw 208 V Facility Planning Clearance NOTE: Clearance dimensions are published for airflow and service access only. Consult with the local safety codes and standards for additional requirements in your local area. Environmental Operating Temperature Storage Temperature Relative Humidity Operating Elevation Storage elevation Audible noise at 1 meter from front of unit 0 to 40 C (32 to 104 F) Storage with batteries: -15 to 45 C (5 to 104 F) 13 Storage without batteries: -30 to 70 C (-22 to 158 F) 0 95% non-condensing 0 3000 meters (0 10000 feet) 0 15000 meters (0 50000 feet) < 58 dba @ < 70% load of system size when configured with 1 to 2 power modules (< 100% load with 3 power modules); 25 C < 64 dba @ > 70% load of system size when configured with 1 to 2 power modules; 25 C Protection Class NEMA 1 Color Black 13. Note that for storage with batteries: at 25 C battery self discharge is approximately 6 8 months at 45 C battery self discharge is approximately 1 2 months 16 990 4640B 001

Facility Planning 20 kw 208 V Heat Dissipation Heat Dissipation 50% load 75% load 100% load Batteries fully charged (BTU/hr) 2038 2946 4117 Batteries charging (BTU/hr) 4494 5402 6573 NOTE: Batteries fully charged is a continuous rating. Batteries charging is for 3 hours max. Charging losses are based on 3000 W and 95% charger electronic efficiency and 80% battery charging efficiency. 990 4640B 001 17

20 kw 208 V Drawings Drawings NOTE: A comprehensive set of drawings is available on the engineering website at engineer.apc.com. NOTE: These drawings are for reference ONLY subject to change without notice. Single Feed with MBP One Line Diagram 18 990 4640B 001

Options Options 20 kw 208 V Hardware Options Symmetra Power Module 10 kw Power Module, 208 V (SYPM10KF2) Symmetra Battery Systems Modular battery module (SYBT4) Modular battery cabinet (SYCFXR8) Modular battery cabinet with 8 battery modules & startup (SYCFXR8 8) Modular battery cabinet with startup (SYCFXR8S) Optional Management Devices 2-Port interface expander (AP9607) UPS network management card (AP9630CH) UPS network management card 2 with environmental monitoring (AP9631) UPS management SmartSlot card with dry contact (relay) support to monitor external triggers and initiate actions on external devices. (AP9613) Configuration Options Unity power factor corrected ENERGY STAR-certified Swappable battery and power modules Main and redundant intelligence modules Automatic internal bypass Service included Generator compatible Network manageable Internal N+1 redundancy Top feed Extended battery runtime Line-up/remote modular battery cabinets StruxureWare Data Center Expert compatible SmartSlot device management card Secondary network management card 990 4640B 001 19

20 kw 208 V Schneider Electric Limited Factory Warranty Schneider Electric Limited Factory Warranty Three Phase Power Products or Cooling Solutions One-Year Factory Warranty The limited warranty provided by Schneider Electric in this Statement of Limited Factory Warranty applies only to products you purchase for your commercial or industrial use in the ordinary course of your business. Terms of Warranty Schneider Electric warrants that the product shall be free from defects in materials and workmanship for a period of one year from the date of product start-up when start-up is performed by Schneider Electric-authorized service personnel and occurs within six months of the Schneider Electric shipment date. This warranty covers repairing or replacing any defective parts including on-site labor and travel. In the event that the product fails to meet the foregoing warranty criteria, the warranty covers repairing or replacing defective parts at the sole discretion of Schneider Electric for a period of one year from the shipment date. For Schneider Electric cooling solutions, this warranty does not cover circuit breaker resetting, loss of refrigerant, consumables, or preventive maintenance items. Repair or replacement of a defective product or part thereof does not extend the original warranty period. Any parts furnished under this warranty may be new or factoryremanufactured. Non-transferable Warranty This warranty is extended to the first person, firm, association or corporation (herein referred to by You or Your ) for whom the Schneider Electric product specified herein has been purchased. This warranty is not transferable or assignable without the prior written permission of Schneider Electric. Assignment of Warranties Schneider Electric will assign you any warranties which are made by manufacturers and suppliers of components of the Schneider Electric product and which are assignable. Any such warranties are assigned AS IS and Schneider Electric makes no representation as to the effectiveness or extent of such warranties, assumes no responsibility for any matters which may be warranted by such manufacturers or suppliers and extends no coverage under this Warranty to such components. Drawings, Descriptions Schneider Electric warrants for the warranty period and on the terms of the warranty set forth herein that the Schneider Electric product will substantially conform to the descriptions contained in the Schneider Electric Official Published Specifications or any of the drawings certified and agreed to by contract with Schneider Electric if applicable thereto ( Specifications ). It is understood that the Specifications are not warranties of performance and not warranties of fitness for a particular purpose. 20 990 4640B 001

Schneider Electric Limited Factory Warranty Exclusions 20 kw 208 V Schneider Electric shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user or any third person misuse, negligence, improper installation or testing. Further, Schneider Electric shall not be liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection, inappropriate on-site operation conditions, corrosive atmosphere, repair, installation, start-up by non-schneider Electric designated personnel, a change in location or operating use, exposure to the elements, Acts of God, fire, theft, or installation contrary to Schneider Electric recommendations or specifications or in any event if the Schneider Electric serial number has been altered, defaced, or removed, or any other cause beyond the range of the intended use. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH. SCHNEIDER ELECTRIC DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, SCHNEIDER ELECTRIC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE SCHNEIDER ELECTRIC SOLE LIABILITY AND PURCHASER S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. SCHNEIDER ELECTRIC WARRANTIES RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES. IN NO EVENT SHALL SCHNEIDER ELECTRIC, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER SCHNEIDER ELECTRIC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES, SPECIFICALLY, SCHNEIDER ELECTRIC IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR REVENUE, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE. NO SALESMAN, EMPLOYEE OR AGENT OF SCHNEIDER ELECTRIC IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY. WARRANTY TERMS MAY BE MODIFIED, IF AT ALL, ONLY IN WRITING SIGNED BY AN SCHNEIDER ELECTRIC OFFICER AND LEGAL DEPARTMENT. Warranty Claims Customers with warranty claims issues may access the SCHNEIDER ELECTRIC worldwide customer support network through the SCHNEIDER ELECTRIC web site: http://www.schneider ELECTRIC.com/support/contact/. Select your country from the country selection pull-down menu. Open the Support tab at the top of the web page to obtain contact information for customer support in your region. 990 4640B 001 21

Schneider Electric 35 rue Joseph Monier 92500 Rueil Malmaison France + 33 (0) 1 41 29 70 00 www.schneider-electric.com As standards, specifications, and design change from time to time, please ask for confirmation of the information given in this publication. 2014 2016 Schneider Electric. All rights reserved. 990 4640B 001