DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

Similar documents
3.5 Exposure Control Measures

LABORATORY HOOD MANUAL

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

---:...-- Environmental Health & Safety RADIATION PROCEDURES MANUAL. Procedure Cover Sheet. Procedure Number: EHS REV 2

How to Use a Chemical Fume Hood Safely

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

January, 2014 Page 1 of 6

Design Standard - Fume Hoods & Fume Hood Exhausts

USER'S GUIDE TO FUME HOODS. Procedures for Increasing the Effectiveness of Laboratory Hoods. Revised December, Hood Basics

TABLE OF CONTENTS STANDARDS FOR THE DESIGN, CONSTRUCTION, MAINTENANCE AND USE OF LABORATORY FUME HOODS. Effective August 2010

UNIVERSITY OF ROCHESTER DESIGN STANDARDS JANUARY 2012 SECTION FUME HOODS AND LOCAL EXHAUST SYSTEMS

Bench fume hood with horizontal sash - 14" working sash height. Bench fume hood with vertical sliding doors 14" working gap between doors

UNR Ventilation Policy

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

Ductless Nanoparticle Containment Enclosures

Lab Safety & Energy Optimization. Introduction & Agenda

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating Ventilating and Air Conditioning ODG010107

Element D Services Heating, Ventilating, and Air Conditioning

Compounding Safety Solutions.

Requires Ductwork and Blower

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

HOODS AIR CHEM SYSTEMS, INC.

LABORATORY FUME HOODS

Protector XStream Laboratory Hoods

Ventilated Balance Enclosures

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

Ductless Nanoparticle Containment Enclosures

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

FUME HOOD SELECTION GUIDE

Ductless Nanoparticle Containment Enclosures

Guidance Document. Controlling Quantities of Hazardous Chemicals in Fire Control Zones

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

Fume cupboards and extraction devices

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

An Energy Assessment of Fume Hoods with and without Automated Sash Positioning Control Systems at Amgen, Inc.

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

High Performance Ductless Balance Enclosures

Laboratory Fume Hood. Operation & Maintenance Manual APR 2005

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Class II biological safety cabinets

Fume Hood Operation & Maintenance Manual

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY

STATE UNIVERSITY CONSTRUCTION FUND

new fume hoods providing performance and protection

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Thermo Scientific Hamilton Air Flow Products. Table of Contents

Polypropylene Total Exhaust Fume Hoods

DIAGNOSTIC TESTING USING ASHRAE 110. Gerhard Knutson, Ph.D., CIH Knutson Ventilation, Inc

LABORATORY FUME HOODS

FE-WS6 Downflow Ductless Workstation. Operator s Manual

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

Powered Air Purifying Respirator (PAPR) For Departments that Store, Supply and Maintain PAPR Units

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

BioPROtect III. and BioPROtect III Jr. Class II Style Walk-In Clean Air and Containment Enclosures.

Esco Ascent Max Ductless Fume Hood

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

High protection against allergens and contaminants Spacious working area High cleanability and visibility Microprocessor controls and safety alarms

PCR Laminar Flow Cabinets

Technical Standard for Radiological Air Cleaning and Ventilation Systems at Jefferson Lab

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

Protector Demonstration Hoods

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

LABORATORY FUME HOODS OF 5

UC Irvine Environmental Health & Safety SECTION: TITLE: Powered Industrial Truck (Forklift) Safety Program

Downflo workstation DuSt ColleCtorS

BSC-1100IIA2-X is designed to meet the operating principles:

OPERATION INSTRUCTIONS

General Application Ductless Fume Hoods

downflo workstation dust collectors

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

CG2010 Cytogard Cytotoxic Drug Safety Cabinets

MODEL NUMBER NOMENCLATURE. The model described above is a Side Access Housing, 4,000 CFM, 2 stages PX1224 cells, epoxy coated construction.

General. Technical Bulletin: ACCESSORY INFORMATION

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

Thermo Scientific Hamilton Horizon Fume Hoods. Operation, Maintenance and Installation Instructions

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

Powered Industrial Trucks

VCM LAMINAR FLOW HOOD VERTICAL

General Purpose Walk-In Fume Hood

biolus BIO SAFETY CABINET

Element D Services Heating Ventilating and Air Conditioning ODG010107

General Purpose Walk-In Fume Hood

INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V)

Healthcare Solutions Room Pressure Monitors and Controls

Model ND-2 Specification

Automatic Cyanoacrylate Fuming Chamber XL. Safely Obtain Quality Latent Prints and Reproducible Results

Labconco 48, 60, and 72 Hoods

Underutilized Technologies

MODEL FA5 Air Filtration System. Operations Manual

INSTRUCTION MANUAL. AMS 1500 One Piece. Negative Pressure Unit (AMS-1500 NPU 230V)

Airstream. Class II Type A2 Bioltogical Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

Air Sentry High Performance Fume Hood Operation & Maintenance Manual

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

F. VAV hoods shall have a restricted bypass plate.

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

Transcription:

DEPAUL UNIVERSITY Fume Hoods Manual Environmental Health & Safety April 2017

1 TABLE OF CONTENTS SECTION PAGE NO. 1. INTRODUCTION 2 2. TYPES OF FUME HOODS 2 2.1 CONVENTIONAL FUME HOODS 2 2.2 HIGH PERFORMANCE FUME HOODS 2 3. FUME HOOD COMPONENTS 3 3.1 HOOD BODY 3 3.2 WORK SURFACE 3 3.3 EXHAUST PLENUM 3 3.4 AIR FOIL SILL 3 3.5 BAFFLES 3 3.6 SASH 4 4. FUME HOOD PERFORMANCE INDICATORS 4 5. EVALUATION AND MAINTENANCE 4 5.1 ANNUAL INSPECTION 4 6. USING A FUME HOOD 5 6.1 BEFORE USING A FUME HOOD 5 6.2 WHEN USING A FUME HOOD 5 APPENDICES Appendix A: Appendix B: OTHER HOOD TYPES PROGRAM HISTORY

2 1. INTRODUCTION Fume hoods are a type of ventilation system used in many laboratories throughout the University. Their primary function is to exhaust chemical fumes, vapors, gases, dusts, mists, and aerosols. They also serve as physical barriers between reactions and the laboratory environment, offering a measure of protection against inhalation exposure, chemical spills, run-away reactions, and fires. A typical fume hood has a box-like structure with a moveable sash window. Experimental procedures are performed within the hood which is consistently and safely ventilated, usually by means of an extract blower and ductwork. Chemical fumes are exhausted and diluted many times over in the atmosphere and have an insignificant effect on human health. Fume hoods function by maintaining a relatively negative interior pressure while continuously drawing air through the sash opening, which prevents contaminants from escaping. A suitable hood face velocity (the speed at which air is drawn into the hood) is critical to safe and effective operation. While excessive face velocities can result in turbulence and reduce containment, insufficient velocities also compromise performance. In general, a hood s cubic face velocity is recommended to be between 0.3 m/s (60 cubic feet per minute) and 0.5 m/s (100 fpm). 2. TYPES OF FUME HOODS The two main types of fume hoods used in laboratories are covered in this section. See Appendix A for descriptions of other ventilating enclosures that may be present on campus. 2.1 Conventional Fume Hoods Conventional fume hoods draw a constant volume of air through the sash opening. They have no features to vary the velocity or volume of air entering the fume hood. Most conventional hoods have a two panel baffle system and a moveable sash. 2.2 High Performance Fume Hoods High performance fume hoods are more energy efficient than conventional hoods because of their lower total exhaust volumes. They are designed to take air entering through the sash opening and form a roll in the upper chamber called a vortex. This vortex enhances the hood s containment capability and has been engineered so that the vortex will not break down and collapse. Many high performance hoods have sash doors that slide side to side (horizontally) and vertically. Only open the vertical moving sash to load/unload the hood. Use the horizontal sash doors to create a splash and blast shield while working in the hood. Typically, high performance hoods have audible and visual alarms to indicate if the air-flow is above or below preset alarm levels. Some fume hoods are equipped with on/off switches or variable air velocity (VAV) controls that allow the user to turn the exhaust velocity down during periods of inactivity.

3 3. FUME HOOD COMPONENTS Most fume hoods share common design characteristics. High performance fume hoods incorporate additional or modified components. The basic fume hood components include the hood body, sash, work surface, exhaust, and baffles. 3.1 Hood Body The housing of the fume hood provides the containment for hazardous gases and vapors or the physical barrier between the containment and the outside air. 3.2 Work Surface The work surface or deck is generally a laboratory bench top. 3.3 Exhaust Plenum The shape and location of the exhaust plenum helps to distribute air flow evenly across the hood face. Materials such as paper towels drawn into the plenum can create turbulence in this part of the hood, resulting in areas of uneven air flow and poor performance. 3.4 Air Foil Sill The air foil sill is located along the bottom edge of the fume hood. The air foil performs several important functions: It streamlines the airflow into the hood around the edge, reducing turbulence and loss of containment, The flow continually sweeps the work surface, and It provides a source of air for the hood to exhaust with the sash fully closed. 3.5 Baffles The baffles are moveable partitions used to create slotted openings along the back of the hood body. Baffles keep the airflow uniform across the sash opening to optimize capture efficiency and eliminate dead spots or possible reverse flows at the sash opening which would result in a loss of containment. Baffle Positions Adjusting the baffles allows the user to accommodate light vapors or dense, heavy vapors as necessary. High performance fume hoods have louvered or articulated baffles that allow more flexibility. Baffle positions open and close the slots between the panels. In a three panel louvered baffle system, the baffles would be adjusted as follows to accommodate light or dense vapors: Light vapors: Maximum airflow is required at the top. Top slot is fully opened and the center and bottom slots are in the open position.

4 Normal Operation: The top, center, and bottom slots are all open evenly to provide uniform flow. Heavy vapors: Maximum flow is required at the bottom near the work surface. The top slot is closed and the center and bottom slots are open. 3.6 Sash The sash located at the front of the hood can be adjusted to optimize the air flow into the fume hood. It provides a protective barrier, a window to observe the activities in the containment, and protects the user s breathing zone from vapors released in the containment. Sash Opening The sash opening or hood face is the imaginary plane from the bottom of the sash to the air foil sill. The face velocity is measured across this plane. Sash Positions There are three typical sash positions to be used by the operator. Closed: All sashes should be closed when the fume hood is not in use. Operating Position or Operating Height: A maximum of 18 inches. The sash should be used at this position whenever work is being performed in the containment. Set-Up Position: Any opening greater than the operating position. The sash should only be used in this position for loading equipment and set-up of materials. Other work should not be performed with the sash in the set-up position. 4. FUME HOOD PERFORMANCE INDICATORS Performance indicators are important safety devices that must be monitored regularly and are necessary for every chemical fume hood on DePaul s campus. Each hood should be equipped with a monitoring device used to continuously measure air flow, and provide a visible reading to the hood user. The most common types of visual performance indicators found in DePaul s laboratories are differential pressure manometers or gauges, and digital monitoring devices. It is important to the health and safety of the laboratory occupants to pay close attention to the digital or posted reading. A broken or missing performance indicator may result in lab occupants being unaware of air flow changes, and increase the risk of chemical exposure. If you believe that your hood is missing a performance indicator, your current device has been damaged, or is out of range; please contact Facility Operations immediately for repair. 5. EVALUATION AND MAINTENANCE 5.1 Annual Inspection On an annual basis, Facility Operations outsources inspections of all chemical fume hoods. Upon completion of the hood inspection, the outsourced company will place a certification sticker on the fume hood indicating who inspected it, the date, and passed or failed. A report is then generated

5 on each fume hood, the original report goes to Facility Operations and Environmental Health & Safety receives a copy. 6. USING A FUME HOOD The fume hood is often the primary control device for protecting laboratory personnel when working with flammable and/or toxic chemicals. OSHA s Laboratory standard (29 CFR 1910.1450) requires that fume hoods be maintained and function properly when in use. 6.1 Before Using a Fume Hood Make sure that you are trained and understand how the hood works. Know the hazards of the chemical you are working with; refer to the chemical s Safety Data Sheet (SDS) if you are unsure. Ensure that the hood is on. Make sure that the sash is open to the proper operating level, which is usually indicated by arrows on the frame. Make sure that the air gauge indicates that air flow is within the required range. 6.2 When Using a Fume Hood Never allow your head to enter the plane of the hood opening. For example, for vertical rising sashes, keep the sash below your face; for horizontal sliding sashes, keep the sash positioned in front of you and work around the side of the sash. Use appropriate personal protective equipment: Eye protection, gloves, lab coat. Be sure that nothing blocks the airflow through the baffles or through the baffle exhaust slots. Elevate large equipment (e.g., a centrifuge) at least two inches off the base of the hood interior. Keep all materials inside the hood at least six inches from the sash opening. When not working in the hood, close the sash. Do not permanently store any chemicals inside the hood. Promptly report any hood that is not functioning properly to Facility Operations. Its sash should be closed and the hood tagged and taken out of service until repairs can be completed. When using extremely hazardous chemicals, understand your laboratory s action plan in case an emergency (e.g., power failure) occurs.

6 APPENDICES APPENDIX A: Other Hood Types Ductless Hood is another type of enclosure hood. Ductless hoods pass air from the hood interior through an absorption filter and then discharge the air into the laboratory. These types of hoods are only suitable for use with nuisance vapors and dusts that do not present fire or toxicity hazards. These types of hood have very specific uses. Capture Hoods are ventilating devices that can be positioned to pull in contaminants that are produced outside of a hood. A sufficient velocity called the capture velocity is necessary to "grab" the contaminant and move it into the hood. They are generally used in welding and grinding operations. Receiving Hoods are devices generally used to exhaust heat, water vapor, odors, and other non-hazardous materials. They are not a laboratory hood and generally are not effective for exhausting toxic or flammable materials. Biological Safety Cabinets are special safety enclosures used to handle and contain pathogenic microorganisms or chemotherapeutic agents. Biological safety cabinets are NOT laboratory fume hoods. Biological safety cabinets provide protection for the product and also protect laboratory personnel by utilizing vertical airflow.

7 APPENDIX B: Program History Date Revision Number Brief Description of Changes Review Completed by April 2017 1 No significant changes K. Abma

8 ACKNOWLEDGEMENTS This manual was developed using best practice examples from OSHA and the University of Chicago as well as Federal and State regulations and guidance documents.