RP100 Series. 2.4GHZ Extended Range. 32-bit Microprocessor. Radio Receiver Model: RP100 / RP / 10 Digital Output

Similar documents
Current Steering Module ECM0001

ANTI-TWO-BLOCK SYSTEM

Power Conversion. Battery Chargers. Model

Timer Relays - Fixed & Adjustable

Innovative Controls Inc. SL Series Tank Level Monitor

Timer Relays - Fixed & Adjustable

Power Conversion. Battery Chargers. Model

User s Manual TX MHz Powercaster TM Transmitter

Timer Relays - Fixed & Adjustable

Model H30 Operation Manual

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRODUCT OVERVIEW. Our Mission:

Whale - Electric Bilge Pump Range From the Experts in Bilge Pumps experience in electronics

ICS Switch Panel. Introducing the new

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Warning Lamps. Bus Warning Light Kits 110. Headlights On Units 113. Headlight Flasher 114

Low Oil Controller Installation and Operations Manual. CS SS07-A2 P/N Enclosure

INSTRUCTIONS. 20 Circuit Wiring Kit Instructions October 2009, Speedway Motors, Inc.

Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents:

TELEMOTIVE APPENDIX F 10K Stepless Electronic Transfer Switch

New Products. Fast Acting / Open Link Design. For high amperage applications

LED Light Emitter - Blue, Red, Green, or Amber LEDs - 12 LEDs - 36 Watts V Lumen

8000 Series Liquid Flow Meter

Model 277EC ENGINE IDLE LIMITER

Two Channel Remote Shutdown Device

DT Series Technical Manual

Contents. Glossary Common terms and definitions

garage door operators

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

9419 E US HWY 175, Kemp, TX Phone: Fax:

6500DC Dual Motor Wireless Controller Kits

Bringing Component Parts Together

Low Profile, High Intensity LED Light Bars - 27, 3-Watt LEDs VDC Lumen

WIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECTOR

Installation and Operating Manual

240SS Power Unit. Installation Manual. AMKUS, Inc. is an ISO 9001 registered company.

New Product Introduction: Limitless WGLA Series Global Limit Switch and WPMM Monitor

Lt.Blue/Black. White. Orange. LED Blue LED Yellow LED Red

e -Stroke e-s 3 / GEN 3 Tractor / Truck / Bus Parts List

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

ELECTRICAL SYSTEM RP-7

CA-510a Installation Instructions

PRELIMINARY. Ordering Part Numbers: Converter P/N: AX082600

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

PBS M Marine Push Button Start

Ebling Back Blade Snow Plow Wireless Controller Kit Only sold by SnowplowsPlus.com and ControlAllWireless.com

Installation and Operation Guide

Installing the gate post bracket with the cardboard arm template

TOUGH, RUGGED CONTROLLERS

Charging Battery Based Power Supply Systems Remote Terminal Units (RTU) Power Conditioning for Controls & Instrumentation Switchgear

DIESEL Engine Fire Pump Controllers Features

SP Series - Part Numbering

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

TENSION LOAD. Product Overview

Power Converters. Output Current Function Design Features

3 Channel Remote Start / Keyless Entry System Installation Instructions

INTRO INTRO. Intella is pleased to introduce the A.T.I.B product line of forklift battery chargers.

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

100 Watt LED Light lumens Volts DC - Adjustable Surface Mount - Flood LED Light

ATIB CHARGERS FOR FORKLIFT TRUCKS

CONSUMABLES POWER 099 POWER CONNECTIONS 108 FUSES 115 CIRCUIT BREAKERS 116 FUSE HOLDERS 126 RELAYS & FLASHER UNITS 131 SOLENOIDS 132 JUNCTION BOXES

nterconnect compatibility new SEALED CONNECTORS harsh environment dual seals for harsh environments ergonomic locking tab for easier mating

anchor winches mini genius

INSTRUCTIONS 12 Circuit Wiring Kit Instructions

Not Included. Rear Half Harness

65 Watt High Intensity LED Light - 120/277V AC ft Spot Beam - 6.7" OD Light Head

3200NT Timer Service Manual

Busbars, Terminals and Accessories

500 Watt Portable LED Work Area Light Cart ft cord - 60,000 Lumens V AC

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

CONTROL UNITS VEHICLE EXHAUST GASES. Pure advantages

Senior Swing Control Box. Table of Contents

Warning Lamps. Bus Warning Light Kits 90. Headlights On Units 93. Flasher Units 94

APOLLO Gate Operators, Inc.

Gen INSTALLATION MANUAL

Topcon X30 Display Kit Installation Manual 54VT-TC-X30

Data Sheet P1A Pressure Sensor

WIRELESS CAMPER JACK LITERATURE NUMBER REV. C CCD WARNING PERSONAL INJURY & PROPERTY DAMAGE WARNING EXPLOSION. Effective NOV 2018

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

WIRELESS TRI-JACK WIRELESS REMOTE KIT COMPONENTS LITERATURE NUMBER REV. C WARNING EXPLOSION WARNING PERSONAL INJURY & PROPERTY DAMAGE

TC26-B Vehicle Sensor

Model PRO 9246CH Installation Manual

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL

FOLD SEQUENCE VERSION 2 & 3 ISO 6. Operator s Manual FOLD 1 FOLD 2 FOLD 3 FOLD 4 FOLD 5 FOLD 6 FOLD 7 FOLD 8 IMP-LIFT DISC COULTER MARKER

Wedge in Plugs Stock No

LED Blasting Light - Waterproof - Magnetic Mount Lumens - High Voltage

High Intensity Colored LED Light - 90 Watts - 30 LEDs - Red, Amber, Green, Blue

Selection Guide Motor Control Device Solutions

Installing the gate post bracket with the cardboard arm template

Valve Sensor Options ELECTRONIC CONTROLS INTEGRAL POSITION SENSOR EMI/RFI CE-RATED POSITION SENSOR RATINGS SENSOR WIRING HYDRAFORCE.

OEM Pressure Transmitters

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

Lippert Components, Inc. Informational Publication ENTRY DOOR LATCH INFORMATION - SOUTHCO

Installation Instructions for TM470 Interfacing with 1708 and 1939.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

36EFC. Series & EFC Valve Package

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

CP 634 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM

CA 421 Installation Instructions

Transcription:

Engineering & Manufacturing Solutions 2.4GHZ Extended Range RP100 Series Radio Receiver Model: RP100 / RP01000002 / 10 Digital Output Sealed To IP67 32-bit Microprocessor ISO 9001:2008 WITH DESIGN Certificate #02.002.1

Features & Applications RP Series Radio Receiver / RP100 / RP0100002 / 10 Digital Outputs FEATURES: Engineered and manufactured in the USA FCC, IC, CE certified by accredited independent laboratory RoHS Complaint 2.4 GHz with Extended Range and DSSS ( Direct Sequence Spread Spectrum ) Worldwide license free operation 32-bit ARM-Core Digital Microprocessor Simple, straight forward, easy to install Encapsulated waterproof control package 500 ft. range line of sight LED diagnostic indicators Reverse polarity protection Wireless pairing function Loss of signal timeout Universal for 12VDC or 24VDC systems No perceivable delay between transmitter and receiver Multiple system may operate within the same area in close proximity without interfering with each other Optional factory master output configuration Factory configurable for custom applications* Factory custom wire/cable harnesses available* APPLICATON: The RP Series radio receiver is used to control the ON/OFF functions of hydraulic valves for cylinders and motors from a remote location. This series can also be used to control other devices that meet the electrical requirements. Ex. lights, horns, contactors, relays. APPLICATON EXAMPLES: Tow Trucks Winches Boat Lifts Gates Conveyor Systems Service Truck Crane Stump Grinders AG Equipment Power units Automobile Carriers Grain Carts Turf Equipment Paving Equipment Door Lifts Lighting/Horns A-49 REV(D)

DESCRIPTION: The fully encapsulated RP Series are compact, durable, sealed and easy to install radio receivers. All exposed components on the receiver are made from non corrosive materials. This receiver is designed with Direct Sequence Spread Spectrum (DSSS) modulation for superior performance. It is a perfect complement to the Brand Series 21, Series 36 and Series 38 stackable directional control valves. Other control valves or solenoids meeting the appropriate specifications may be controlled as well. SAFETY: Our RP Series radio receivers are built with high quality long life components that are designed for use in harsh environments. We use the latest wireless and microprocessor technology including a 32-bit ARM-Core microprocessor to give these small controls some serious digital muscle. Our unique network design allows for operation of multiple units in the same location without interfering with each other. Safety and protection features: Watchdog monitor Over-current protection Short circuit protection Loss of signal timeout Reverse polarity protection Load dump protection Back EMF protection on all outputs Back-feed protected outputs Description / Safety / Reliability RELIABILITY: All Brand Hydraulics Co. products are backed by lifetime technical support from the engineers at the Brand Hydraulics Co. manufacturing facility. Our electrical engineers are ready to assist you before and after the sale with technical support. Brand Hydraulics Co. products are backed by a 2 year Limited Warranty Policy. Please visit our website at www.brand-hyd.com for more information. MASTER OUTPUT OPERATION: Part number RP01000005 (9 Digital Outputs + 1 Master Digital Output) is factory programmed for master output on OUTPUT #1. With this setup OUTPUT #1 will always go active when any transmitter function button is pressed. The #1 function button on the transmitter will control output #2 on the RP100 receiver. Ex. button #1 controls output #2, button #2 controls output #3 and so on. If you have a 10 function button transmitter being used with a 10 output RP01000005 the last function button, #10, will not have an associated output. A-50

Specifications RP Series Radio SPECIFICATIONS: Receiver / RP100 / RP0100002 / 10 Digital Outputs Digital Outputs 10 ( 1 ON at a time ) Consult factory for other options Back EMF Protection Yes Output Switching Type Automotive Grade, High side switch Output current per output 3 Amps Total Maximum current 6 Amps Short Circuit Protection Shutdown 10A Supply Voltage, DC Only 8-30VDC LED Indicators Transmit, Reset, Power Good, Reverse Polarity, Output Active (one for each output) Antenna Internal Range 500 ft. line of site. Depends on environment Operating Temperature -40 C - 85 C (-40 F - 185 F) Storage Temperature -40 C - 85 C (-40 F - 185 F) Ingress Protection IP67 Frequency 2.4 2.483 GHz Modulation DSSS (Direct Sequence Spread Spectrum) Weight 10 oz, less any connector plug assemblies Enclosure Material Glass filled plastic Approvals USA FCC Part 15.109 European Union CE (EN ETSI 301 489-1, V1.9.2) Canada ICES-003 A-51 REV(D)

RP100 DIMENSIONS DETAILS: 2.25 4.5 1.8 0.83 Dimensions & Connector Details 3.0 2.6 0.36 0.185 #8 Button Head Type Screw Recommended RP100 CONNECTOR DETAILS: For factory use only. Do NOT remove this plug or make connections at this location. Receptacle - A Deautsch DT Series Keyed - A, Gray P/N: DTF15-12PA PIN 1 - Power Input PIN 2 - NC PIN 3 - Output 4 PIN 4 - Output 3 PIN 5 - Output 2 PIN 6 - Output 1 PIN 7 - Ground PIN 8 - Ground PIN 9 - Ground PIN 10 - Ground PIN 11 - Spare Ground PIN 12 - System Ground Receptacle - B Deautsch DT Series Keyed - B, Black P/N: DTF15-12PB PIN 1 - Output 10 PIN 2 - Output 9 PIN 3 - Output 8 PIN 4 - Output 7 PIN 5 - Output 6 PIN 6 - Output 5 PIN 7 - Ground PIN 8 - Ground PIN 9 - Ground PIN 10 - Ground PIN 11 - Ground PIN 12 - Ground A-52

Diagnostic Indicators & Typical System Configuration RP Series Radio Receiver / RP100 / RP0100002 / 10 Digital Outputs RP100 Diagnostic Indicators: RP100 DIAGNOSTIC INDICATORS: TRANSMIT (GREEN/RED) OUTPUT 1 (RED) OUTPUT 2 (RED) OUTPUT 3 (RED) POWER GOOD (GREEN) REVERSE POLARITY (AMBER) OUTPUT 8 (RED) OUTPUT 7 (RED) OUTPUT 6 (RED) OUTPUT 5 (RED) OUTPUT 4 (RED) RESET (YELLOW) OUTPUT 9 (RED) OUTPUT 10 (RED) TYPICAL SYSTEM CONFIGURATION: NOTE: With P/N: RP01000005 Output #1 is always active when any other ouput is active. Power In 8-30VDC ( Customer Supplied ) Fuse 15 A Fast Acting Type ( Customer Supplied ) Power Switch A1 Output 1 ( 3 Amp Max ) Output 2 ( 3 Amp Max ) Output 3 ( 3 Amp Max ) A6 B5 A7 B8 A5 B4 A8 B9 A4 B3 A9 B10 A3 B2 Output 6 ( 3 Amp Max ) Output 8 ( 3 Amp Max ) Output 9 ( 3 Amp Max ) Output 4 ( 3 Amp Max ) A10 Output 5 ( 3 Amp Max ) Output 7 ( 3 Amp Max ) B11 B6 B1 B7 B12 Output 10 ( 3 Amp Max ) A12 A11 Note: PIN A11 Spare Ground does not require connecting System Ground 0 VDC REV(D) A-53

COMMON MODEL CODES: RP01000002...( 10 Digital Outputs Digital Outputs) RP01000005 ( 9 Digital Outputs + 1 Master Digital Output) MATING BRAND HYDRAULICS TRANSMITTER MODELS: V100 V200 V300 V400 V500 Common Model Codes & Options OPTIONAL PARTS: E2368 Deutsch 12-contact plug body, A-Key, Gray Deutsch P/N: DT06-12SA E2369 Deutsch 12-contact plug body, B-Key, Black Deutsch P/N: DT06-12SB E2371 Wedge lock for 12-contact plug, Orange Deutsch P/N: W12S E1827 Terminal, socket, size 16 Deutsch P/N: 0462-201-16141 E2024 Sealing Plug, Locking, Size 16, White Deutsch P/N: 0413-217-1605 E2401 8-Contact plug ( For sealing receptacle on RP100 only ) OPTIONAL ACCESSORIES: E2365 Deutsch 12-contact flying lead connector assembly, A-Key, 12 12 leads E2366 Deutsch 12-contact flying lead connector assembly, B-Key, 12 12 leads Brand Hydraulics can produce custom wire and cable harnesses Contact your local Brand Hydraulics distributor for pricing What is Included: Quantity Description 1 RP100 Series, 10 Digital Output Radio Receiver *Some options and custom changes may require minimum quantities. It is the purchaser s responsibility to determine the suitability of any Brand Hydraulics product for an intended application, and to insure that it is installed in accordance with all federal, state, local, private safety, health regulations, and codes and standards. Due to the unlimited variety of machines, vehicles, and equipment on which our products can be used, it is impossible for Brand Hydraulics to offer expert advice on the suitability of a product for a specific application. We believe that it is our customer s responsibility to undertake the appropriate testing and evaluation to prevent injury to the end user. All product, product specifications and data are subject to change without notice to improve reliability, function or design or otherwise. A-54