MISSOURI SERVICE AREA

Similar documents
MISSOURI SERVICE AREA

SERVICE CLASSIFICATION NO. 7 LARGE GENERAL TIME-OF-DAY SERVICE

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-27 CUSTOMER GENERATION PRICE PLAN FOR RESIDENTIAL SERVICE

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. TIME-OF-USE GENERAL POWER RATE--SCHEDULE TGSA (November 2018)

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. Availability

RATE 624 RATE FOR ELECTRIC SERVICE GENERAL SERVICE LARGE

THE NARRAGANSETT ELECTRIC COMPANY LARGE DEMAND RATE (G-32) RETAIL DELIVERY SERVICE

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. LARGE MANUFACTURING SERVICE RATE SCHEDULES (November 2018)

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. Availability

FLORENCE ELECTRICITY DEPARTMENT. GENERAL POWER RATE--SCHEDULE GSC (October 2015) Availability

Large Power Service Time of Use

FLORENCE ELECTRICITY DEPARTMENT. MANUFACTURING SERVICE RATE--SCHEDULE TDMSA (October 2015) Availability

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-21 PRICE PLAN FOR RESIDENTIAL SUPER PEAK TIME-OF-USE SERVICE

Schedule TOU-EV-7 Sheet 1 GENERAL SERVICE TIME-OF-USE, ELECTRIC VEHICLE CHARGING

Rate Schedules. Effective 1/1/2019

National Grid. Narragansett Electric Company INVESTIGATION AS TO THE PROPRIETY OF COMPLIANCE TARIFF CHANGES. 2 nd Amended Compliance Filing

Large Power Service Time-of-Use (LPS-TOU)

Schedule TOU-EV-9 Sheet 1 GENERAL SERVICE TIME-OF-USE, ELECTRIC VEHICLE CHARGING, LARGE DEMAND METERED

RATE 724 RATE FOR ELECTRIC SERVICE GENERAL SERVICE LARGE

STANDBY SERVICE. Transmission Service Primary Service Secondary Service

Schedule TOU-EV-8 Sheet 1 GENERAL SERVICE TIME-OF-USE, ELECTRIC VEHICLE CHARGING, DEMAND METERED

BrightRidge Large Commercial and Industrial Rates October 2017 Billing Cycle All Rates Subject to TVA s Fuel Cost Adjustment (separate schedule)

MISSOURI SERVICE AREA

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after January 1, 2014.

Revised Cal. P.U.C. Sheet No E Cancelling Revised Cal. P.U.C. Sheet No E

TERRITORY: This rate schedule applies everywhere PG&E provides electric service. I

M.P.S.C. No. 2 Electric Third Revised Sheet No. 65 (Rate Case) Cancels Second Revised Sheet No. 65

Resolution 12- introduced and read the following resolution

MISSOURI SERVICE AREA

MISSOURI SERVICE AREA

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after February 1, 2019.

PUBLIC SERVICE COMPANY OF NEW MEXICO ELECTRIC SERVICES COGENERATION AND SMALL POWER PRODUCTION FACILITIES

SERVICE CLASSIFICATION "CEF" COMMUNITY ENERGY FACILITY

First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO.

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Noble County Rural Electric Membership Corporation

RATE 725 RATE FOR ELECTRIC SERVICE METAL MELTING SERVICE

REQUIREMENTS FOR PARALLEL OPERATION FOR CUSTOMERS WITH GENERATION NOT EXCEEDING 50 kw

September 21, Advice No , NEW Schedule 50 Retail Electric Vehicle Charging Rates

Louisville Gas and Electric Company

D Original Sheet No. 11!81 Revised

Interconnection of Distributed Generation Net Metering (Excluding Solar*Rewards) DATE: August 17, 2015

Revised Cal. P.U.C. Sheet No E Cancelling Original Cal. P.U.C. Sheet No E

RATE 732 RATE FOR ELECTRIC SERVICE INDUSTRIAL POWER SERVICE

RATE APPLICATION MANUAL. Kansas City Board of Public Utilities

Montana-Dakota Utilities Co. A Division of MDU Resources Group, Inc. 400 N 4 th Street Bismarck, ND 58501

Southern California Edison Revised Cal. PUC Sheet No. Withdrawn Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Tariff cover sheets reflecting all rates approved for April 1 in Dockets 4218 (ISR) and 4226 (Reconciliation Filing).

MISSOURI SERVICE AREA

ELECTRIC SCHEDULE EV Sheet 1 RESIDENTIAL TIME-OF-USE SERVICE FOR PLUG-IN ELECTRIC VEHICLE CUSTOMERS

Indianapolis Power & Light Company I.U.R.C. No. E-18 Original No. 17 One Monument Circle Indianapolis, Indiana

White River Electric Association, Inc. Net Metering Information & Service Requirements

INDEX OF RATE SCHEDULES. Schedule Classification Sheet No.

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

STANDBY SERVICE. RULES AND REGULATIONS: Terms and conditions of this schedule and the General Rules and Regulations govern use of this schedule.

Street Address. City-Village-Township

Portland General Electric Company Eleventh Revision of Sheet No. 7-1 P.U.C. Oregon No. E-18 Canceling Tenth Revision of Sheet No.

Definitions. Scope. Customer Generation Interconnection Requirements

SCHEDULE 6 RESIDENTIAL SERVICE ON-SITE GENERATION

ROANOKE ELECTRIC COOPERATIVE RATE SCHEDULES

FRENCH BROAD ELECTRIC MEMBERSHIP CORPORATION RATE SCHEDULES

Large General Service Time-of-Use Storage Program

HAYWOOD ELECTRIC MEMBERSHIP CORPORATION WAYNESVILLE, NORTH CAROLINA ELECTRIC RATE SCHEDULES

Schedule D DOMESTIC SERVICE

RATE 633 RATE FOR ELECTRIC SERVICE HIGH LOAD FACTOR INDUSTRIAL POWER SERVICE

P. SUMMARY: The Southeastern Power Administration (SEPA) establishes Rate Schedules JW-

MEMBER RELATIONS POLICY NO SUBJECT: INTERCONNECTION OF CUSTOMER GENERATION RESOURCES

EXHIBIT A ORDINANCE NO. O CITY OF LAURINBURG, NORTH CAROLINA SCHEDULES OPR RESIDENTIAL TIME-OF-USE SERVICE

Net Metering Program

2018 Customer generation rates

Case/Order Reference(s): Approved at the February 26, 2014 Admin. Mtg.

RESIDENTIAL SERVICE. CHARACTER OF SERVICE: This Schedule is for single phase, alternating current at standard voltage as designated by the Utility.

SCHEDULE 84 CUSTOMER ENERGY PRODUCTION NET METERING SERVICE

To complete the process for a net metering interconnection, please follow the steps below:

AUSTIN UTILITIES. CHARACTER OF SERVICE: AC, 60 cycles, 120/240 Volt, three wire, single-phase; or 120 Volt, two wire.

PET(S) FIRST & LAST NAME: January 2019

Edmond Electric Standard Pricing Schedules

SCHEDULE 62 COGENERATION AND SMALL POWER PRODUCTION SCHEDULE - IDAHO

Tariff changes effective: Riders PIV and R-PIV effective Usage on and after September 21, 2016.

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

Revised Cal. P.U.C. Sheet No E** Pacific Gas and Electric Company Cancelling Revised Cal. P.U.C. Sheet No E San Francisco, California

P.S.C. No. 9 - Electricity Consolidated Edison Company First Revised Leaf No. 310 of New York, Inc. Superseding Original Leaf No.

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Street Address. City-Village-Township

Power Supply Cost Recovery

Matthew K. Segers Office 202, An Exelon Company Assistant General Counsel

PIEDMONT ELECTRIC MEMBERSHIP CORPORATION ELECTRIC SERVICE RATES

Umatilla Electric Cooperative Net Metering Rules

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

Phone (602) Toll Free (800) Fax (602) CALENDAR OF FILING DEADLINES AND SEC HOLIDAYS

Revised Cal. P.U.C. Sheet No E Cancelling Revised Cal. P.U.C. Sheet No E. San Francisco, California

Norris Public Power District

North Dakota Commercial and Industrial Electric Prices

Per Meter, Per Month. Effective July 1, 2018 Customer Charge Flat Charge $8.86

HOUSE BILL No Koch

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Edmond Electric Standard Pricing Schedules

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

Transcription:

MO.P.S.C. SCHEDULE NO. 6 2nd Revised 170 6 1st Revised 170 FROM QUALIFYING FACILITIES 1. *STANDARD RATES FOR PURCHASE The standard rates for purchase from a customer with a design capacity of 100 kw or less are as follows: a. Non-Time - Differentiated Energy Rate Summer Rate (Applicable during 4 monthly billing periods of June through September) Summer Winter Rate (Applicable during 8 monthly billing periods of October through May) Winter 2.68 per kwh 2.47 per kwh b. Time-Differentiated Energy Rate Summer Rate (Applicable during 4 monthly billing periods of June through September) Weekday (10 AM - 10 PM) Weekday (10 PM - 10 AM) Saturday, Sunday, Holiday (1) 3.35 per kwh 2.20 per kwh 2.47 per kwh Winter Rate (Applicable during 8 monthly billing periods of October through May) Weekday (10 AM - 10 PM) Weekday (10 PM - 10 AM) Saturday, Sunday, Holiday (1) 2.75 per kwh 2.34 per kwh 2.30 per kwh (1) Legal Holidays of New Year's Day, Good Friday, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, Thanksgiving Friday, Christmas Eve Day, and Christmas Day. c. Customer Charge (per meter required for parallel operation) Non-Time Differentiated Energy Single Phase Three Phase Time Differentiated Energy Single Phase Three Phase $4.00 per month $6.00 per month $13.00 per month $15.00 per month *Indicated Revision DATE OF ISSUE February 2, 2017 DATE EFFECTIVE March 4, 2017 ISSUED BY Michael Moehn President St. Louis, Missouri

MO.P.S.C. SCHEDULE NO. 6 1st Revised 170.1 6 Original 170.1 FROM QUALIFYING FACILITIES (Cont'd.) 2. APPLICATION This tariff applies to purchases of electric energy or electric energy and capacity from Qualifying Facilities (hereinafter referred to as "Customer") under the provisions of Rule 4 CSR 240-20.060 of the Missouri Public Service Commission (Commission). * Company shall not be obligated to enter into new contracts or obligations to purchase electric energy or capacity from Qualifying Facilities with a net capacity larger than 20,000 kilowatts as ordered by the Federal Energy Regulatory Commission in Docket No. QM16-2-000 on June 30, 2016. 3. BILLING Monthly billing between Company and Customer shall be in accordance with the Contract between the parties. 4. CONTRACT Whether or not purchases are made by Company under the standard rates, the Company shall not be required to make any purchase from Customer until Company and Customer have entered into a written contract for such purchases. 5. GENERAL RULES AND REGULATIONS All provisions of this tariff are subject to all Commission rules and regulations as may be revised from time-to-time. All terms of the tariff are also subject to the Commission s normal complaint and arbitration procedures. *Indicates Addition DATE OF ISSUE February 2, 2017 DATE EFFECTIVE March 4, 2017 ISSUED BY Michael Moehn President St. Louis, Missouri

MO.P.S.C. SCHEDULE NO. 6 Original 170.2 FROM QUALIFYING FACILITIES (Cont'd.) GUIDELINE TECHNICAL REQUIREMENTS FOR PARALLEL OPERATION WITH THE COMPANY S SYSTEM Introduction The minimum technical requirements for safe parallel operation of Customer-owned electrical generating facilities with the Company s system are set forth below. These requirements will serve as a guide for Company and Customer engineering when planning such an installation; however, it is recognized that each installation may have specific requirements other than those set forth herein as a result of each installation s unique nature. General Technical Requirements 1. Protection Customer shall install protective devices capable of detecting fault conditions on both his system and the Company s system. These devices will separate Customer s system from the Company s system either directly or through an auxiliary device such as a circuit breaker. The separating device must be capable of interrupting the available fault current. The detection sensitivity and operating speed of these devices must be compatible with protective devices on the Company s system. The Customer shall install equipment designed to automatically separate his system from the Company s system upon loss of the normal Company supply. The Customer is responsible for protecting Customer-owned equipment in such a manner that faults or other disturbances on the Company s system or on Customer s system do not cause damage to his equipment. Customer shall furnish information to Company regarding his proposed generation equipment and protective devices prior to parallel operation. Company will check the adequacy of this proposed equipment and its compatibility with protective devices on the Company s system and will either approve as submitted or specify additional equipment which will be required in order to begin parallel operation with the Company s system. All protective relay settings that would affect any Company system relay settings will be specified by Company. These relays will be initially calibrated by Company to assure proper operation. A manual visible disconnect switch must be provided which is under the exclusive jurisdictional control of the Company dispatcher. This manual switch must have the capability to be locked out of service by a Company-authorized switchman.

MO.P.S.C. SCHEDULE NO. 6 Original 170.3 FROM QUALIFYING FACILITIES (Cont'd.) General Technical Requirements (Cont'd.) 1. Protection (Cont'd.) The above statements are the basic minimum protection requirements that would be associated with parallel generation. Additional requirements and/or equipment would depend on an in-depth study of each proposed connection. 2. Operation Under certain conditions the intertie breaker (if one is required) must be operated by Customer in order for Company to operate the manual disconnect switch. Company may request this action for any of the following reasons: a. System emergency. b. Inspection of Customer s generating equipment or protective equipment reveals an unsafe condition. c. Customer s generating equipment interferes with other customers or with the operation of the Company s system. d. An outage is scheduled on the Company s supply circuit or feeder. Customer shall be solely responsible for properly synchronizing his generating equipment with the Company s frequency and voltage. This includes resynchronizing his generator(s) after system outages or disturbances. 3. Quality of Service The interconnection of Customer s generating equipment with the Company s system shall not cause any reduction in the quality of service being provided to other customers or cause any undesirable effect on any Company facilities. In order to achieve this objective, wave form guidelines presently applicable to Customer s facility and which are measured at the point of interconnection between the Company and the qualifying facility are as follows: a. The phase unbalance must be less than 1%, b. The arithmetic sum of harmonics in the current or voltage must be less than 10%, and c. The root of the sum of the squares of harmonics in the current or voltage must be less than 5%. The above lists should be viewed as general guidelines which are subject to change as dictated by experience as well as the unique nature of the electrical system at each point of interconnection. The power factor of Customer s load with his generating equipment connected shall not be less than that specified by retail tariff for his applicable customer class.

MO.P.S.C. SCHEDULE NO. 6 Original 170.4 FROM QUALIFYING FACILITIES (Cont'd.) General Technical Requirements (Cont'd.) 4. Metering Parallel generating facilities connected to Company s system are divided into two groups: (a) Two-way Power Flow, and (b) One-way Power Flow. Two-way Power Flow would apply to Customer s facilities whose load is sufficiently variable or smaller than its generating capacity so that excess Customergenerated power could flow into the Company s system. One-way Power Flow would apply to Customer s facilities whose load is significantly larger than their generating capacity so that no Customer-generated power would flow into the Company s system except under fault conditions. a. Two-way Power Flow This type of installation provides for the interchange of energy in either direction as a normal operating mode. The revenue metering for Two-way Power Flow installations shall include two series connected watthour meters with detents. One meter shall be connected to measure energy supply to Customer from Company; the other meter shall measure Customer-generated energy supplied to Company. The meter detents prevent operation of either meter in the reverse direction. Additional metering may or may not be required depending on the terms of the contract between Company and Customer. b. One-way Power Flow This type of installation does not allow the interchange of energy from Customer to the Company. The intertie circuit breaker will be tripped by equipment capable of detecting the reverse power flow condition toward the Company s system. This type installation requires a single revenue meter installation with detent to prevent operation of the meter in the reverse direction. Additional metering may or may not be required depending on the terms of a contract between Company and Customer. 5. Other Requirements All Customer installations shall adhere to any applicable requirements of the National Electrical Safety Code, the National Electric Code, Institute of Electrical and Electronics Engineers (IEEE), Underwriters Laboratories (UL), local electric codes, applicable NEMA codes, OSHA, and Company s Electric Service Rules as set forth in published tariffs. Customer will bear all interconnection costs of parallel operation over and above the normal cost to serve his load.