Enclosed Safety Switches

Similar documents
Catalog Number Description

Catalog Number Description

Catalog Number Description

Catalog Number Description

Catalog Number Description

Catalog Number Description

Catalog Number Description

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Alert: Square D Safety Switches

Heavy Duty Safety Switches

1.1. Switching Devices

QMB Fusible Panelboards

1.1. Switching Devices. Safety Switches

Solar Combiner Solutions

Section 3. Table of Contents. Safety Switches. General Duty. Light Duty. Heavy Duty. Double Throw 3-1

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

Solar Combiner Solutions

SPEEDFAX TM 2011 Disconnect Switches Contents

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Light Duty. General Duty. Heavy Duty. Double Throw Vdc Photovoltaic Heavy Duty Disconnect Switch. Standards:

Air Conditioning Disconnects Molded Case Switch

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Product Specification Sheet #3LD2.1

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Bussmann series Quik-Spec Coordination Panelboard

Quik-Spec Electrical Gear

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

MP Meter-Pak Meter Centers

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Quik-Spec. Section Contents

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Selection and application guide

Effective December 2015 Supersedes September 2013

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

EPOXY POWDER COATED COPPER FREE ALUMINUM

IN2 Enclosed Switches and Circuit Breakers

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

GHN424NW HHN426N HUN361AW

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

OTEC Transfer switch open transition

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Wastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors

6.2. Power Pedestals. Contents

T CLASS T FUSE BLOCKS

Design Standard. Purpose: Design Standard:

Section 4 Square D QO Loadcentres

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Transfer switch OTEC open or delayed transition

Just the right switch for your application

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

Type VBII Visible Blade Disconnect Switches

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

5.2. Power Pedestals. Contents Description

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Safety Switch. Type VBII. cross-reference GUIDE

POWERBUS 225 Busway and Plug-In Units

A. Submit manufacturer's literature and technical data before starting work.

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Transfer switch OTEC and OTECSE open transition

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages

Hazardous Duty Applications

Panelboards Circuit Breaker / Lighting and Distribution

Quik-Spec Coordination Panelboard Specifications

EDS / EFS Series Control Stations

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Transcription:

Enclosed Safety Switches Catalog CT0901 09 Class CONTENTS Description............................................. Page General Duty Safety Switches.............................. Page 4 Heavy Duty Safety Switches.............................. Page 11 Double Throw Safety Switches............................ Page 4

Enclosed Safety Switches CONTENTS CATALOG NUMBER DESCRIPTION... GENERAL DUTY SAFETY SWITCHES... 4 Product Description... Configuration... Construction... Enclosures... 6 Accessories... 6 Class R Fuse Kits... 6 Fuse Puller Kits... 6 Equipment Grounding Kits... 6 Electrical Interlock Kits... 7 Field-Installed Lug Kit... 7 Class J Fuse Kit... 7 HEAVY DUTY SAFETY SWITCHES... 11 Product Description... 1 Configuration... 1 Construction... 1 Enclosures... 1 Receptacle Switches... 14 Appleton Powertite Receptacle... 14 Crouse-Hinds Arktite Receptacle... 14 Hubbellock Receptacle... 14 Motor Disconnect Switches... MD... Compliances... Application... 16 Standards... 16 General dc and Photovoltaic Systems... 17 Special Applications... 19 Accessories... Hubs... Class R Fuse Kits... Solid Neutral Assemblies... Equipment Grounding Kits... Electrical Interlock Kits... 1 Fuse Puller Kits... 1 Optional Compressor Lugs... 1 Key Interlock System... 1 Lock-Off Guard... Internal Barrier Kits... DOUBLE THROW SAFETY SWITCHES... 4 Product Description... 44 Construction... 44 Enclosures... 44 Accessories... 4 NOTE: For information on Replacement Parts with specific part numbers, go to www.schneiderelectric.us, click on Product FAQ s, enter the device catalog number, click SEARCH, then look for the information required. 09 Schneider Electric 11/09

Catalog Number Description Enclosed Safety Switches Number Segment Character Description D 1 N RB L=Light duty D=General duty Fusible H=Heavy duty Type of Switch DT=Double throw DU=General duty Non-Fusible HU=Heavy duty DTU=Double throw 1 1 pole poles Blades Switchable Poles poles 4 4 poles 6 6 poles 1 1 Vac (plug fuse) Voltage Rating 1 Vac 6 0 Vac 1 A A A 4 0 A Ampere Rating 0 A 6 0 A 7 800 A 8 A Factory-installed neutral (neutrals are field-installed on most general duty, heavy duty, Neutral N and double throw safety switches). No suffix NEMA Type 1 A NEMA Type 1K AWK NEMA Type 1 (without K.O.) DF NEMA Type 4X Fiberglass reinforced polyester Enclosure DS NEMA Types 4, 4X, and (Type 4 stainless steel) DX NEMA Type 4X Krydon 1 Factory Modifications For dc ratings, see the latest catalog listing. R NEMA Type R RB NEMA Type R (bolt-on hub provision) SS NEMA Types 4, 4X, and (Type 16 stainless steel) CLR Class R fuse kit EI or EI Electrical interlock kit GL Equipment ground lugs GLC Equipment ground lug, copper only KI, KI or KIKI 1 or Key interlocks LK Compression lugs (800 and A only) NP Phenolic legend plate PB Push buttons, pilot lights, selector switches. Customer must provide catalog number of control device to be installed SLC Copper lugs ( 0 A) SP Special paint colors SPLO Lock-on provision VW Viewing window WA Appleton interlocked receptacle WC Crouse-Hinds Arktite interlocked receptacle WH Hubbellock interlocked receptacle 09 Schneider Electric 11/09

Enclosed Safety Switches GENERAL DUTY SAFETY SWITCHES CONTENTS Product Description... Configuration... Construction... Enclosures...6 Accessories...6 Class R Fuse Kits...6 Fuse Puller Kits...6 Equipment Grounding Kits...6 Electrical Interlock Kits...7 Optional Field-Installed Lug Kit...7 Class J Fuse Kit...7 Application and Standards...8 4 11/09 09 Schneider Electric

General Duty Safety Switches Enclosed Safety Switches General Duty Safety Switches Product Description General duty safety switches are designed for residential and commercial applications where durability and economy are a prime consideration. Typical loads include lighting, air conditioning, and appliances. They are suitable for use as service equipment when equipped with a factoryinstalled neutral assembly or field-installed service grounding kit, as applicable. General duty safety switches are UL Listed, File E8, and meet or exceed the NEMA Standard KS1. The switches are also available with CSA rating. Configuration Two fusible switched poles with insulated, grounded neutral Three fusible, switched poles with insulated, grounded neutral Two or three, not fusible, switched poles without insulated, grounded neutral Construction Indoor NEMA Type 1 or Outdoor NEMA Type R enclosures Visible blades for positive indication that the switch is OFF Quick-make, quick-break operating mechanism Lugs suitable for aluminum or copper conductors. See page 8 for additional lug data Spring reinforced, plated copper fuse clips Visible Blade Construction Operating Mechanism with Line Base Series F Series F handle/lock-plate is a field-replaceable modular design Series F operating mechanism is an enclosed, field-replaceable, modular design Series F NEMA Type R covers have side opening construction Top endwalls in 0 A NEMA Type R switches have bolt-on hub provisions Multiple padlock provisions in OFF position Tangential combination knockouts alleviate the need for offset bends Wall 09 Schneider Electric Tangential Knockouts 11/09

Enclosed Safety Switches General Duty Safety Switches Enclosures Enclosures are finished in gray, baked enamel that is electrodeposited on cleaned, phosphatized steel. NEMA Type 1 general purpose, indoor NEMA Type R general purpose, outdoor Accessories Rainproof Hubs Bolt-on hubs for rainproof applications. Switches with RB suffix accept /4 through -1/ inch bolt-on hubs. Switches with R suffix have blank endwalls. Class R Fuse Kits For systems up to,000 rms symmetrical amperes See page 9 for selection RB Hub Class R Fuse Kits Series F Fuse Puller Kits Kit consists of three fuse pullers as required for a -pole fusible A or A general duty switch. Kits can be installed into or A Series F switches. Table 1: Fuse Puller Kits Equipment Grounding Kits Aluminum or copper conductors Field-installed Table : Equipment Grounding Kits Fuse Puller Kit Series F Switch Ampere Rating Series Number Fuse Puller Kit Catalog Number F FPK0 F FPK06 and A A Switch Ampere Rating Catalog Number Equipment Grounding Kit Catalog Number, Series E PKGTA1 () 1 Cu or () Al or (1) 4 Al/Cu Max. Series F GTK0 () 1 Cu or () Al or (1) 4 Al/Cu Max. () 1/0 Al/Cu Max. 0 A 0 PK0GTA () /0 Al/Cu Max. Grounding Kits 0, 0 PK0GTA (Two required) () /0 Al/Cu Max. Per Lug 800 PK0GTA (6) /0 Al/Cu Max. 6 11/09 09 Schneider Electric

Enclosed Safety Switches General Duty Safety Switches Electrical Interlock Kits Electrical interlocks for Series F 0 A general duty safety switches and Series F A fusible general duty safety switches are available in kit form for field installation. Each kit contains instructions for proper field mounting. A pivot arm operates from switch mechanism, breaking the control circuit before the main switch blades break. Switches with electrical interlocks installed are UL Listed, Table : Electrical Interlock Kits Switch Ampere Rating Electrical Interlock Kit Catalog Number 1 Fusible Series F Series F 0 EIK01 or EIK0 EIK-1 or EIK- 1 Electrical interlock kit catalog numbers with -1 suffix indicate one normally open and one normally closed contact; - indicates two normally open and two normally closed contacts. Kits are UL Listed. Table 4: Electrical Interlock Contact Ratings 1 AC or Hz DC Interlock Type Volts Make Break Cont. Volts Make / Break Cont. 1.00 A.00 A.00 A 1 0. A.00 A 1 N. O. / 1 N. C. Contact (-1 Suffix ) N. O. / N. C. Contacts (- Suffix ).00 A.00 A.00 A 0. A.00 A 480.00 A 6.00 A.00 A 0 8.00 A.00 A.00 A 0 0.0 A.00 A 1.00 A.00 A.00 A 1 1.00 A.00 A.00 A 1. A.00 A 0. A.00 A 480 7. A 0. A.00 A 0 6.00 A 0. A.00 A 0 0. A.00 A 1 Single-pole single-throw interlock kits are rated 1/ hp at 1 and Vac. -1 Suffix uses a 9007A01 limit switch. - Suffix uses a 9007C0 limit switch. Optional Field-Installed Lug Kit Kit consists of three line, three load, and two neutral lugs as required for a -pole 0 A or 0 A general duty switch. Kit can be installed on 0 A or 0 A Series E switches only. Table : Field-Installed Lug Kit Switch Ampere Rating Lug Kit Catalog Number Wire Range/NEC Lug Wire Range 0 or 0 Series E 1 GDLK 1-1/0-0 kcmil -1/0-0 kcmil 4-1/0- kcmil -1/0-0 kcmil 4-1/0- kcmil 1 Not suitable for use on 0 A NEMA Type R. Field-Installed Lug Kit for 0 and 0 A Devices Class J Fuse Kit The Class J Fuse Kit consists of three Class J fuse adapters as required for a three-pole fusible 0 A general duty switch. Kit can be installed in 0 A Series E switches only (NEMA Type 1). Table 6: Class J Fuse Kit Switch Ampere Rating Class J Kit Cat. No. 0 A Series E GDJK0 09 Schneider Electric 11/09 7

Enclosed Safety Switches General Duty Safety Switches L11N NOTE: Switch is load make/break. Application General duty safety switches are designed for the following applications: Residential and light commercial applications Infrequent or moderate operations Vac maximum Up to,000 rms symmetrical amperes, using appropriately rated Class R fuses and Class R Fuse Kits, or Class T or J fuses 800 A Horsepower rated Load-make, load-break rated for the switch current rating. The light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms, furnaces and garages. Light dutyvisible blades,000 A short circuit current rating A fusible and non-fusible, Vac Replacement parts not available Available with plug or cartridge fuse holders Standards General duty safety switches are manufactured in accordance with these standards: UL 98, Standard for Enclosed and Dead Front Switches. UL Listed under File E8 NEMA Standards Publication KS1, Enclosed Switches Federal Specifications WS-86c for Type NDS (NEMA Type 1) and Type LD (NEMA Type R) UL/CSA Listed Short Circuit Current Rating (RMS Symmetrical) Switch Type Fuse Class Short Circuit Rating Fusible Non-Fusible 1 Table 7: Terminal Lug Data 1 Plug H J R T ka ka ka ka ka H ka J ka R ka T ka 1 The UL Listed short-circuit current rating for Square D general duty non-fusible switches is based on the switch being used in conjunction with fuses. Evaluation of non-fusible switches in conjunction with molded case circuit breakers has not been performed. If a UL Listed short circuit current rating is required, this non-fusible switch must be replaced with a Square D general duty fusible safety switch, equipped with the appropriate class and size fusing. The UL Listed short circuit current rating of the fusible switch is typically as follows: when used with Classes H and K fuses ka, Classes J and R fuses ka. Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. ka for A non-fusible switch. Ampere Rating Conductors Per Phase Wire Range Wire Bending Space Per NEC Table 1.6 AWG/kcmil Lug Wire Range AWG/kcmil 8 11/09 1 1 1 6 (Al) or 14 6 (Cu) 1 6 (Al) or 14 6 (Cu) 1 (Al) or 14 (Cu) (Al) or 14 (Cu) 1 1 1 (Al) or 14 1 (Cu) 1 1/0 (Al) or 14 1/0 (Cu) 0 1 6 (Al/Cu) 6 0 (Al/Cu) 0 NEMA Type1 0 NEMA Type 1 or 1/0 0 (Al/Cu) or 1/0 0 (Al/Cu) 1/0 (Al/Cu) (1) 1 7 (Al/Cu) or () 1/0 0 (Al/Cu) (1) 1/0 0 (Al/Cu) or () 1/0 (Al/Cu) 0 4 0 (Al/Cu) 4 0 (Al/Cu) 800 /0 0 (Al/Cu) /0 0 (Al/Cu) A switches suitable for C or C conductors. 0 800 A switches suitable for C conductors. 09 Schneider Electric

Enclosed Safety Switches General Duty Safety Switches Catalog Number Series Class R Fuse Kits Available for Field-Installation 1 Horsepower Ratings 1 Vac Vac Vac Max. Max. L111N L11N L1N D11N D11NRB D1N D1NRB DN DNRB DN DNRB D4N 4 D4NRB 4 DN Catalog Number 1Ø 1Ø 1Ø Ø 1Ø Ø E 1/ E E 1 Rejection kits are available for Series D, E1, E, and F1 switches. When installed, this kit rejects all but Class R fuses. When installed with this kit and Class R fuses, the switch is UL Listed for use on systems with up to,000 RMS symmetrical amperes available fault current. For corner grounded delta systems only, use switching poles for ungrounded conductors. Suitable for use as service equipment; requires field installation of a service grounding kit (see Digest 1, page -). Solid neutral assembly for Series F is SNA for the DU4 or DU4RB. 4 For 0% neutral, order (1) additional neutral kit SNA and (1) neutral jumper kit SNNI. Suitable for use as service equipment; requires field installation of solid neutral assembly D0SN. 6 Includes factory-installed neutral. 7 Includes factory-installed grounding kit. 8 Not service entrance rated. 9 Enclosed molded case switch. 9 09 Schneider Electric 11/09 1-1/ 1-1/ 1/ 1-1/ E DRK 1-1/ 1-1/ F1 RFK0L 1-1/ F RFK F1 HRK E DRK DNR E1 D6N E DRK0 D6NR E1 DRK0 D1N D1NRB E DRK 1-1/ DN DNRB F1 RFK0L 1-1/ DN F RFK DNRB D4N 4 F1 HRK D4NRB 4 DN DRK 1 E DNT DRKNR DRK 1 E1 DRKNTR D6N DRK0 1 E D6NT D6NR DRK0 1 E1 D6NTR DU1RB E DURB E1 DU 4 DURB 4 F DU4 4 DU4RB 4 F1 DU 4 1 E DU6 4 1 QO0TR 6 7 8 QONATS 7 9 QO00NRB QO00NS T7N T7NR G E E1 E1 E1

Enclosed Safety Switches General Duty Safety Switches H 11/09 W W / H W W / H Typical NEMA Type 1 D Typical NEMA Type R D Table 8: 1 Catalog Number L111N 1 Switch Dimensions Series H W W/H D in. mm in. mm in. mm in. mm E 7.6 194.00 17 6.1 6 4.00 L11N 1 E 7.6 194.00 17 6.1 6 4.00 L1N 1 E 7.6 194.00 17 6.1 6 4.00 D11N 1 E 9. 6. 171 7. 184.6 9 D11NRB 1 E 9.6 4 7. 184 7. 197. 9 D1N 1 E 9. 6. 171 7. 184.6 9 D1NRB 1 E 9.6 4 7. 184 7. 197. 9 DN F1 14. 71 6.1 16 7.4 189 4.87 14 DNRB F1 14.88 78 6.6 168 7.4 189 4.87 14 DN F 17. 44 8. 16. 6. 16 DNRB F 17. 44 8. 16. 6. 16 D4N F1 77 17. 48 1 48 8. D4NRB F1 9. 74 17. 48 1 48 8. DN E 4.1 1146 4.00 6 4.88 6 8.88 6 DNR E.6 778 1.8 4. 6 7 D6N 1 E 49.1 148 4.00 6 4.88 6 8.88 6 D6NR 1 E 49.1 148 4. 69.1 68 8.88 6 D1N 1 E 9. 6. 171 7. 184.6 9 D1NRB 1 E 9.6 4 7. 184 7. 197. 9 DN F1 14. 71 6.1 16 7.4 189 4.87 14 DNRB F1 14.88 78 6.6 168 7.4 189 4.87 14 DN F 17. 44 8. 16. 6. 16 DNRB F 17. 44 8. 16. 6. 16 D4N F1 77 17. 48 1 48 8. D4NRB F1 9. 74 17. 48 1 48 8. DN 1 E 4.1 1146 4.00 6 4.88 6 8.88 6 DNT 1 E 4.1 1146 4.00 6 4.88 6 8.88 6 DNR E1.6 778 1.8 4. 6 7 DNTR E1.6 778 1.8 4. 6 7 D6N 1 E 49.1 148 4.00 6 4.88 6 8.88 6 D6NT 1 E 49.1 148 4.00 6 4.88 6 8.88 6 D6NR E1 49.1 148 4. 69.1 68 8.88 6 D6NTR E1 49.1 148 4. 69.1 68 8.88 6 DU1RB 1 E 9.6 4 7. 184 7. 197. 9 DURB 1 E1 9.6 4 7. 184 7. 197. 9 DU1 1 E 9. 6. 171 7. 184.6 9 DU1RB 1 E 9.6 4 7. 184 7. 197. 9 DU 1 E1 9. 6. 171 7. 184.6 9 DURB 1 E1 9.6 4 7. 184 7. 197. 9 DU F1 17. 44 8. 16. 6. 16 DURB F1 17. 44 8. 16. 6. 16 DU4 F1 77 17. 48 1 48 8. DU4RB F1 9. 74 17. 48 1 48 8. DU 1 E 4.1 1146 4.00 6 4.88 6 8.88 6 DU6 1 E 49.1 148 4.00 6 4.88 6 8.88 6 QO0TR 1 G 6. 16 4.6 118.88 99 QONATS E 9. 4.88 14. 8 QO00NRB E1 14.00 6 7. 197 4. 114 QO00NS 1 E1 1.8 6.1 6. 89 T7N 1 E1 49.1 148 4.00 6 4.88 6 8.88 6 T7NR 1 E1 49.1 148 4. 69.1 68 8.88 6 Does not have a cover draw as indicated in above drawing. 09 Schneider Electric

HEAVY DUTY SAFETY SWITCHES CONTENTS Product Description...1 Configuration...1 Construction...1 Enclosures...1 Receptacle Switches...14 Appleton Powertite Receptacle...14 Crouse-Hinds Arktite Receptacle...14 Hubbellock Receptacle...14 Motor Disconnect Switches... MD... Applications...16 Standards...16 General dc and Photovoltaic Systems...17 Special Applications...19 Accessories... Hubs... Class R Fuse Kits... Solid Neutral Assemblies... Equipment Grounding Kits... Electrical Interlock Kits...1 Fuse Puller Kits...1 Optional Compression Lugs...1 Key Interlock System...1 Lock-Off Guard... Internal Barrier Kits... General Information...8 09 Schneider Electric 11/09 11

Product Description The Square D brand Heavy Duty Safety Switch is designed to be tough, reliable and provide exceptional performance in the most grueling conditions; from commercial and institutional to industrial and manufacturing facilities. Square D F Series safety switches provide significantly higher levels of mechanical endurance than NEMA KS-1 requires. The design life of a Square D F-Series switch is a minimum of three times the NEMA requirement. An abundance of copper is used in the heaviest current carrying power paths of all Square D Heavy Duty Safety Switches. The more copper for current carrying paths, the lower the temperature rise. Managing temperatures inside the switch is the key to providing greater service life. All heavy duty safety switches feature a quick-make, quick-break operating mechanism, a dual cover interlock and a color-coded indicator handle. Series F Operating Mechanism Series F Visible Blades Configuration Two or three fusible switched poles with or without insulated, solid grounded neutral Four or six fusible switched poles without insulated, solid grounded neutral Two, three, four or six non-fusible, switched poles without insulated, solid grounded neutral Three fusible switched poles without insulated solid grounded neutral interlocked to Appleton, Crouse-Hinds, or Hubbellock receptacle Three non-fusible switched poles without insulated solid grounded neutral interlocked to Appleton, Crouse-Hinds, or Hubbellock receptacle Construction Visible blades for positive blade position indication Optional viewing window allows visual verification of blade position without opening door; not available on NEMA Type 4X fiberglass reinforced polyester or Krydon enclosures or NEMA Type 7 or 9 enclosures Red and black handle indication for switch position Series F handle, mechanism, and lock plate are field replaceable Series F Type R devices have side-opening covers Highly visible embossed ON-OFF marking Quick-make, quick-break, spring-driven operating mechanism Front removable mechanical lugs. Refer to page 8 for further lug data Standard lugs accommodate aluminum or copper cable termination Optional lugs accommodate copper only cable termination Mechanical Lugs 1 11/09 NEMA Type 1 NEMA Type R NEMA Types 4, 4X, and Stainless Steel NEMA Type 1 09 Schneider Electric

Dual cover interlock keeps the cover closed when switch is ON. When the cover is open, it interlocks the switch OFF, unless the interlock is bypassed. Factory-installed fuse pullers on A NEMA Types 4, 4X, and stainless steel, NEMA Type 4X fiberglass reinforced polyester, Krydon and NEMA Types 1 or 1K switches. Available for field installation on A F Series switches, NEMA Types 1 and R switches. Class J fuse provisions on A 0 A, 0 V switches and 0 A, V switches. 0 A devices require a mounting kit (catalog number H0J). 0 A switches are shipped with standard Class H fuse spacing. These switches will accept Class R fuses also. A field-installable rejection kit is available, which, when installed, rejects all but Class R fuses. See pages through 6 for Class R fuse kits. Multiple padlock provision in OFF position (three padlocks). Lock-on provisions for factory or field modification. Tangential combination knockouts lessen the need for conduit offset bends. Fuse Pullers Lock-off Provision with Optional Lock-off Guard Kit Installed Enclosures Class J Fuse Provisions Alternate mounting holes make for easy conversion to Class J fuses. Tangential Knockouts Wall NEMA Type 1 general purpose, indoor NEMA Type R rainproof, outdoor NEMA Types 4, 4X, indoor or outdoor, watertight, dust-tight, and corrosion-resistant (Types 4 and 16 stainless steel) NEMA Type 4X indoor or outdoor, watertight and dust-tight, and corrosion-resistant (fiberglass reinforced polyester) NEMA Types 7 and 9 hazardous locations: Class I, Groups C and D Class II, Groups E, F and G Class III NEMA Types 1 and1k indoor, dust-tight, and drip-proof NEMA Type 1 has no knockouts (suitable for outdoor use) NEMA Type 1K provided with knockouts 09 Schneider Electric 11/09 1

Receptacle Switches Interlocked receptacle switches are furnished with a factory-installed threephase four-wire Appleton Powertite, Crouse-Hinds Style Arktite, or Hubbellock receptacle. The fourth wire is connected to the switch equipment grounding terminal and is not a solid neutral termination. Interlocking linkage between the receptacle and switch mechanism prevents insertion or removal of the plug while the switch is in the ON position, or insertion of any plug other than specified. The interlocking mechanism also prevents the switch from being turned ON if a plug has not been fully inserted into the receptacle. Appleton Powertite Receptacle H6AWA Interlocked Receptacle Switch with Appleton Powertite Receptacle Devices are UL Listed and CSA Certified, suitable for use as service equipment Receptacles are epoxy powder coated over copper-free cast aluminum A, H6AWA and HU6AWA are stock items. All other items are non-stock and require an 8-week lead time Short circuit rating: ka when used with or protected by Class H or K fuses; 0 ka when used in conjunction with Class R, T, or J fuses Crouse-Hinds Arktite Receptacle Devices are UL Listed and suitable for use as service equipment A, H6AWC and HU6AWC are stock items. All other items are non-stock and require a 1-week lead time Short circuit rating:,000 A when used with or protected by Class H or K fuses; 0,000 A when used in conjunction with Class R, T or J fuses Hubbellock Receptacle H6AWC Interlocked Receptacle Switch with Crouse-Hinds Arktite Receptacle UL Listed and suitable for use as service equipment Short circuit rating: ka H6AWH Interlocked Receptacle Switch with Hubbellock Receptacle 14 11/09 09 Schneider Electric

Motor Disconnect Switches Heavy Duty Safety Switches Square D, a brand of Schneider Electric, brings to the market a comprehensive offering of Motor Disconnect switches listed UL8 "Suitable as Motor Disconnect". The MD IEC9 mechanical interlock receptacle switches address fixed and flexible process requirements. MD The MD motor disconnect is a pin and sleeve interlocked switch receptacle listed UL 8 "Suitable As Motor Disconnect" in one compact Type 4X enclosure. It is offered in,,, and A units compatible with IEC9- plug configurations. The MD UL 8 switch with receptacle interlock allows motor driven equipment and motors to be moved into and out of a given space when necessary. Plus, a key safety feature is that the interlock switch design requires an operator to turn off the load before removing the machine plug from the receptacle. Compliances UL Listed 98 File Number E8 and E17818 UL Listed 8 Industrial Control Equipment UL Listed 168 and 1686 Plugs and Receptacles, Pin and Sleeve Type CSA Certified. No. 4-M91 File Number E4 IEC 9-1; IEC 9- Enclosure: plastic Types 4X and 1 UL 94 V Flame Rating UV Stabilized Material IP66 09 Schneider Electric 11/09

Applications Heavy duty safety switches are designed for the following applications: Commercial and industrial installations Up to 0 Vac or 0 V dc maximum Up to 0,000 rms symmetrical amperes short circuit current A Horsepower ratings Load-make, load-break rated for the switch current rating Two or three fusible switched poles with or without insulated, grounded neutral Four or six fusible switched poles, neutral not available Two or three non-fusible, switched poles with or without insulated, grounded neutral Four non-fusible switched poles, neutral not available Six non-fusible switched poles, neutral not available Tested and approved for seismic applications Standards Heavy duty safety switches are manufactured in accordance with these standards: UL98, Standard for Enclosed and Dead Front Switches. UL Listed under File E8, or E488 NEMA Standards Publication KS1, Enclosed Switches Federal Specifications WS-86c for Type HD 16 11/09 09 Schneider Electric

NOTE: Heavy duty safety switches may be used on photovoltaic systems with a grounded feed. Refer to Figures 1B, 1D, 1F and (negative grounding shown; positive grounded systems are similarly allowed). For ungrounded systems, see National Electrical Code (NEC ) 690. (NEC 08, NFPA 70). Figure 1: Heavy Duty Safety Switches General dc and Photovoltaic Systems As a market leader and innovator in photovoltaic (PV) applications, we are proud to announce a catalog section dedicated to dc and PV safety switch applications. This section focuses on the Square D brand UL approved Heavy Duty Safety Switch dc and PV wiring schemes. Additionally a UL witnessed and Square D self-certified PV wiring option is presented. This additional unlisted option provides a robust, cost effective option for PV systems. All heavy duty safety switches with dc ratings (-, - and 4-pole fusible and nonfusible) are Underwriters Laboratories (UL) Listed and CSA Certified for use on dc applications when wired as shown in Figure 1 (A, B, C, D, E, and F). UL Listed, CSA Certified (Files E8 and E48). Additionally: Heavy duty safety switches are rated for 0 Vdc maximum open circuit voltage. Non-fusible safety switches may carry percent of the nameplate current rating. Fusible safety switches may carry 80 percent of nameplate current rating (continuous use). Heavy duty switches are dc horsepower rated as indicated on the safety switch wiring diagram. Heavy duty switches have a,000 ampere dc short-circuit rating at 0 Vdc unless otherwise stated on the switch wiring diagram. Consult factory for short circuit current ratings at Vdc. Refer to current Square D Digest for lug wire range of heavy duty switches. General dc and Photovoltaic Systems, Fusible and Non-Fusible Wiring Diagram (Non-Fusible Shown) LINE 0 Vdc LINE 0 Vdc LINE 0 Vdc LOAD LOAD LOAD LINE (Four-Pole) A 0 Vdc LINE LOAD (Three-Pole) C 0 Vdc (Two-Pole) E LINE 0 Vdc LOAD LOAD LOAD LOAD 09 Schneider Electric (Four-Pole) B (Three-Pole) D (Two-Pole) F 11/09 17

Alternate Photovoltaic System Wiring, Evaluated and Self-Certified by Schneider Electric (Not UL Listed) Figure : Grounded Feed per NEC Article 690 Photovoltaic Array or String Max Open Circuit Voltage 0 Vdc ( ) ( ) ( ) ( ) ( ) ( ) A, 0 V Fusible or Non- Fusible Disconnect (Fusible Shown) ( ) ( ) ( ) ( ) Connect negative photovoltaic line (-) to case inside inverter for negative grounded system. Positive grounded systems are similarly allowed. For ungrounded systems, see NEC 690. (NEC08, NFPA70). Current Ratings 1 Switch Nameplate 0 V Switch dc Rating per Pole 1 (To Inverter) Photovoltaic Maximum Circuit Current Photovoltaic Short-Circuit Current (l sc ) A A 16 A dc per pole 1.8 A (/1.6) A A 48 A dc per pole 8 A (/1.6) A A 80 A dc per pole 64 A (/1.6) The switch per pole rating must be at least the photovoltaic maximum circuit current multiplied by 1%. From NEC 08 and NFPA 70, Article 690.8: the photovoltaic maximum circuit current is I sc multiplied by 1%. If a non-fusible disconnect is used, the inverter must not be capable of backfeeding currents into a short circuit or fault in the photovoltaic array or string. One inverter may be connected to each pole of the switch. Refer to current Square D Digest for lug wire range of heavy duty switches. 18 11/09 09 Schneider Electric

Special Applications Rainproof Bolt-On Hubs Electrical Interlock Kits Available factory- or field-installed Pivot arm operates from switch mechanism, breaking the control circuit before the main switch blades break Switches with electrical interlocks installed are UL Listed Watertight Hubs Class R Fuse Kits Internal Barrier Kits Provide an additional barrier that helps prevent accidental contact with live parts Field-installed transparent barriers do not restrict visual inspection of the switch Barriers provide IEC9 IPX finger safe protection when door of enclosed disconnect switch is open Convenient door allows use of test probes without accessing fuses Allows for replacement of fuses without removing barrier NOTE: Barrier can also be used with a skirt kit to enclose a panel mounted Type 94 disconnect. Key Interlock Systems Factory-installed only Interlocks are used to prevent the authorized operator from making an unauthorized operation Not available on hazardous location devices (NEMA Types 7 or 9) or fiberglass reinforced polyester (NEMA Type 4X) UL Listed Lock-On Provisions Provision for one /8 in. hasp padlock is available factory-installed on NEMA Types 1, R, 4, 4X and stainless steel and 1 switches This modification will allow the switch to be locked in the ON position UL Listed Special Paint Available painted with special safety colors: safety red, safety orange, safety yellow, safety green, safety blue, safety purple, black or white All colors comply with OSHA Standard 19.144 and ANSI Specification Z.1 for marking physical hazards Phenolic Legend Plate Available engraved and mounted on all heavy duty safety switches, except NEMA Types 7 and 9 Legend engraved in 1/4 in. high white letters on black background Customer must provide legend UL Listed 09 Schneider Electric 11/09 19

Accessories Square D brand heavy duty safety switches manufactured by Schneider Electric are UL Listed for use with the following accessories: Hubs Bolt-on hubs for rainproof applications. Switches with RB suffix accept /4 in. through -1/ in. bolt-on hubs. Switches with R suffix have blank top endwalls. Table 9: Rainproof Bolt-On HubsFor Use on NEMA Type R Enclosures Conduit Size /4 1 1-1/4 1-1/ -1/ -1/ 4 Closing Cap Bolt-On Hubs Hub Cat. Number B0 B B1 B1 B0 B B0 B B0 BCAP NEMA Type R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory-installed. Order bolt-on hubs separately from table above. Hubs through size -1/ in. can be directly installed on RB devices. Devices requiring in. or larger hubs must have holes cut in the field. Gaskets are provided on in. and larger hubs. All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread. Watertight hubs are zinc or chrome plated for field-installation on NEMA Types R, 4, 4X,, and 1 stainless steel switches and Type 1 enclosures. Table : Conduit Trade Size Watertight Hubs 1/ /4 1 1-1/4 1-1/ -1/ -1/ 4 Watertight Hubs Standard Zinc Hub Cat. Number H0 H0 H H1 H1 H0 H H0 H H0 Chrome Plated Hub H0CP H0CP HCP H1CP H1CP H0CP Cat. Number Class R Fuse Kits For systems up to 0,000 rms symmetrical amperes provide rejection for all other fuse types. See pages through 7 for catalog numbers. Class R Fuse Kits Solid Neutral Assemblies Factory or field-installed insulated, grounded solid neutral assemblies. See pages through 6 for catalog numbers. Equipment Grounding Kits Equipment grounding kits available for factory- or field-installation. See pages through 6 for catalog numbers. Field-installed Insulated, Grounded Neutral Field-installed Equipment Grounding Kit 11/09 09 Schneider Electric

Electrical Interlock Kits Electrical interlocks for heavy duty safety switches through A are available factory installed or in kit form for field installation. A pivot arm operates from the switch mechanism, breaking the control circuit before the main switch blades break. Switches with electrical interlock accessories installed are UL Listed. See pages through 6 for catalog numbers. Table 11: Electrical Interlock Contact Ratings 1 Interlock Type 1 N.O./ 1 N.C Contact (-1 Suffix) N.O./ N.C Contact (- Suffix) ac or Hz Volts Make Break Cont. Volts 1 480 0 1 480 0.0 A.0 A.0 A 8.0 A.0 A.0 A 7. A 6.0 A.0 A.0 A 6.0 A.0 A.0 A 1. A 0. A 0. A.0 A.0 A.0 A.0 A.0 A.0 A.0 A.0 A 1 0 1 0 1 Single-pole single-throw interlock kits are rated 1/ hp at 1 and Vac. dc Make and Break 0. A 0. A 0.0 A 1.00 A 0. A 0. A Cont..0 A.0 A.0 A.0 A.0 A.0 A -1 Suffix uses a 9007A01 limit switch. - Suffix uses a 9007C0 limit switch. Fuse Puller Kits Kit consists of three fuse pullers as required for a three-pole fusible V or 0 V heavy duty switch. Kits can be installed in switches manufactured after February, 1980. Fuse pullers are supplied as standard equipment on NEMA Types 1 and 1K; NEMA Types 4, 4X, stainless steel; NEMA Type 4X fiberglass reinforced polyester, and Krydon switches through A. See pages through 6 for catalog numbers. Optional Compression Lugs Refer to page 8 for applicable options. Key Interlock System Interlocks are used to prevent the authorized operator from making an unauthorized operation. The key interlock system is a simple and easy method of applying individual key interlock units and assemblies to the above equipment so as to require operation in a predetermined sequence. UL Listed. They are not available on hazardous location devices (NEMA Types 7 or 9) or fiberglass reinforced polyester (NEMA Type 4X). Use these suffixes on switch catalog numbers: KI = 1 lock per switch KI = 1 lock with cylinders per switch KIKI = separate locks per switch Key Interlock System NOTE: Factory-installed only on heavy duty safety switches. 09 Schneider Electric 11/09 1

Lock-Off Guard Available field-installed only, the lock-off guard works by covering the lockout/tagout opening whenever the switch is in the ON position. This prevents a padlock from being inadvertently inserted into the switch lockplate. The device is designed to help prevent accidental misapplication of a lockout device. These kits are marked curus (UL Component Recognized) for fieldinstallation. Table 1: Lock-Off Guard Applications Switch Rating A A V A 0 V and 0 A Kit Catalog Number LOGK1 LOGK Internal Barrier Kits Lock-Off Guard Shown Internal Barrier Internal Barrier Kits provide an additional barrier that helps prevent accidental contact with live parts. Field-installed transparent barriers do not restrict visual inspection of the switch. Barriers provide IEC9 IPX finger safe protection when door of enclosed disconnect switch is open. Convenient door allows use of test probes without accessing fuses and replacement of fuses without removing barrier. Barrier can also be used with the skirt kit to enclose a panel mounted Type 94 disconnect. Table 1: Catalog Number Internal Barrier Kits Description Safety Switch Application (F Series Only) 94 Type T Disconnect Application SS0 Interior Barrier for A / 0 Vac A Safety Switch 1 Vac A NA Interior Barrier for A 0 Vac A SS06 Safety Switch, or 0 Vac A A 94 Switch 0 Vac A SS Interior Barrier for A Safety Switch or / 0 Vac A 0 Vac A A 94 Switch SS Interior Barrier for 0 A Safety Switch / 0 Vac 0 A NA Skirt Kit to Enclose or 0 Vac A SS06SK A 94 Switch NA (requires SS06) 0 Vac A SSSK Skirt Kit to Enclose A 94 Switch (requires SS) NA 0 Vac A 1 Requires arc shield on V switches be changed to 0 V arc suppressor. 11/09 09 Schneider Electric

11/09 09 Schneider Electric Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs HXFA H1A H1AWK H1DS E1 EIK01 EIK01 EK01 EIK0 EIK0 EK0 RFK0L RFK0L HRK SN SN0 SN0 HSN SN0C SN0C HSNC GTK0 GTK0 PKGTA1 GTK0C GTK0C PKO6GTC1 H1N H1NRB HA HAWK EIK01 EIK01 EIK01 EIK01 EIK0 EIK0 EIK0 EIK0 RFK0L RFK0L RFK0L RFK0L SN0 SN0 SN0C SN0C SN0C SN0C GTK0 GTK0 GTK0 GTK0 GTK0C GTK0C GTK0C GTK0C FPK0 FPK0 HDS HN HNRB HA EIK61 EIK01 EIK01 EIK6 EIK0 EIK0 HRK RFK0L RFK0L RFK HSN SN06 HSNC SN0C SN0C PKGTA1 GTK0 GTK0 PKOGTC1 GTK0C GTK0C FPK0 FPK0 HAWK HDS HN HNRB 01 0 RFK HRK RFK RFK SN06 HSN HSNC FPK06 FPK06 H4A H4AWK H4DS H4N 01 01 01 01 0 0 0 0 HRK HRK HRK HRK H0SN H0SN H0SN H0SNC H0SNC H0SNC H0SNC H4NRB H HAWK HDS E 01 0 HRK H0SNC HN HNAWK HNDS HNR HR HXKA H6 H6AWK C SNA H6DS H6N H6AWK H6NDS H6NR H6R H7 H7AWK H800SN H800SN H7N H7NAWK H7NR H7R H800SN H8 H8AWK H8N H8NAWK HSN HSN PKOGTA8 PKOGTA8 PKOGTA8 PKOGTA8 H8NR H8R H6 H6AWK HSN PKOGTA8 PKOGTA8 H6DS H6R H66 H66A H66AWK H66DS H66R H H800SN HAWK HNAWK HR H68 H800SN H800SN HSN H68AWK H68NAWK H68R H1A EIK01 EIK0 RFK0L HSN HN SN0 SN0C GTK0 GTK0C H1AWK H1DS H1N H1NRB EIK01 EIK01 EIK01 EIK01 EIK0 EIK0 EIK0 EIK0 RFK0L HRK RFK0L RFK0L SN0 HSN SN0C HSNC SN0C SN0C GTK0 PKGTA1 GTK0 GTK0 GTK0C PKOGTC1 GTK0C GTK0C FPK0 FPK0 Continued on next page

09 Schneider Electric 4 11/09 Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs HA HAWK HDS HN EIK01 EIK01 EK61 EIK01 EIK0 EIK0 EIK6 EK0 RFK0L RFK0L HRK RFK0L SN0 SN0 HSN SN0C SN0C HSNC SN0C GTK0 GTK0 PKGTA1 GTK0 GTK0C GTK0C PKO6GTC1 FPK0 HNRB HA HAWK HDS EIK01 EK1 EIK0 0 RFK0L RFK RFK HRK SN06 SN06 HSN SN0C HSNC GTK0 GTK0C FPK0 HN HNRB H4A H4AWK EK1 EK1 0 0 RFK RFK HRK HRK H0SN H0SN H0SNC H0SNC FPK06 FPK06 H4DS H4N H4NRB H EK1 EK1 EK1 0 0 0 HRK HRK HRK H0SN H0SNC H0SNC H0SNC HAWK HDS HN HNAWK HNDS HNR HR H6 E1 H6AWK H6DS H6N H6NAWK E E H6NDS H6NR H6R H7 H800SN H7AWK H7N H7NAWK H7NR H800SN H7R H8 H8AWK H8N H800SN HSN HSN PKOGTA8 PKOGTA8 PKOGTA8 H8NAWK H8NR H8R H61 EIK01 EIK0 RFK0 HSN SN0 SN0C PKOGTA8 PKOGTA8 PKOGTA8 GTK0 GTK0C FPK0 H61-A H61-AWK H61A H61AWA EIK01 EIK0 RFK06 RFK06 RFK0H RFK06 SN06 SN06 SN0. SN0C GTK0 GTK0C ACP4BC H61AWC H61AWK H61DF H61DS F1 EIK01 9999TC EK01 EIK0 9999TC EIK0 RFK06 RFK0H RKF06 HRKH SN0 HSN HSN H0C HSNC HSNC GTK0 PKGTA1 GTK0C PKOGTC1 APJ48 H61DSWC H61DSWA H61DX H61N F1 EK01 K01 9999TC EIK01 EIK0 EIK0 HRKH HRKH RFK06 RFK0H HSN HSNC SN0C GTK0 GTK0C FPK0 APJ48 ACP4BC H61NRB H61RB H61WA H61WC EIK01 EIK01 EIK0 EIK0 RFK0H RFK0H RFK06 RFK06 SN0 SN06 SN0C SN0C GTK0 GTK0 GTK0C GTK0C FPK0 FPK0 FPK06 FPK06 ACP4BC APJ48 H6 H6A H6AWA H6AWC RFK06H RFK06H RFK06H RFK06H SN06 SN06 SN06 SN06 FPK06 ACP4BC APJ648 H6AWH H6AWK H6DF H6DS F1 9999TC EK61 9999TC EK6 RFK06H RFK06H RFK06H HRKH SN06 SN06 HSN HSN HSNC HSNC PKGTA1 PKOGTC1 SD1781 H6DSWA H6DSWK H6DS H6N F1 EK61 EK61 9999TC EK6 EK6 9999TC EK0 HRKH HRKH RFK06H RFK06H HSN HSNC FPK06 ACP4BC APJ648 Continued on next page

11/09 09 Schneider Electric Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs H6NRB H6RB H6WA H6WC RFK06H RFK06H RFK06H RFK06H SN06 SN06 SN06 FPK06 FPK06 FPK06 FPK06 ACP4BC APJ648 H6WH H6 H6A H6AWA RFK06H RFK RFK RFK SN06 SN06 SN06 FPK06 FPK06 SD1781 ACP4CD H6AWC H6AWK H6DF H6DS F1 9999TC EK1 9999TC 0 RFK RFK RFK HRK SN06 SN06 HSN HSNC H6DSWA H6DSWC H6DX H6N F1 EK1 EK1 9999TC 0 0 9999TC HRK HRK RFK RFK SN06 FPK06 ACP4CD APJ487 H6NRB H6RB H6WA H6WC RFK RFK RFK RFK SN06 FPK06 FPK06 FPK06 FPK06 ACP4CD APJ487 H64 H64A H64AWK H64DF E1 01 01 01 9999R8 0 0 0 9999R9 HRK HRK HRK HRK H64DS H64N H64NA H64NAWK EK1 EK1 EK1 EK1 EK EK EK EK HRK HRK HRK HRK H0SN H0SN H0SNC H64NDS H64NRB H64RB H6 EK1 EK1 EK1 EK EK EK HRK HRK HRK H0SN H0SNC H6AWK H6DS H6N H6NAWK H6NDS H6NR H6R H66 H66AWK H66DS H66N H66NAWK H66NDS H66NR H66R H67 H800SN H67AWK H67N H67NAWK H67NR H800SN H67R H68 H68AWK H68N H800SN HSN HSN PKOGTA8 PKOGTA8 PKOGTA8 H68NAWK H68NR H68R H461 RFK06 HSN PKOGTA8 PKOGTA8 PKOGTA8 FPK06 H461AWK H46 H46AWK H46DS EK61 EK6 RFK06 RFK06H RFK06H HRKH PKGTA1 PKOGTC1 FPK06 H46 H46AWK H46DS H464 EK1 EK1 EK EK RFK RFK HRK HRK SN06 FPK06 H464AWK H464DS H46 H46AWK EK1 EK1 EK EK HRK HRK Continued on next page

09 Schneider Electric 6 11/09 Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs H466 HXFA H66AWK H66DS F1 EK1 0 RFK HRK SNA H664DS H664AWK HU6 HU6AWK EK1 EK1 0 0 HRK HRK HU6DS HU6R HU66 HU66AWK HU66DS HU66R HU HUAWK HUR HU68 HU68AWK HU68R H800SN H800SN HSN HSN PKOGTA8 PKOGTA8 HU61 HU61A HU61AWA HU61AWC EIK01 EIK01 EIK0 EIK0 SN0 SN0 SN0C SN0C GTK0 GTK0 GTK0C GTK0C ACP4BC APJ48 HU61AWK HU61DF HU61DS HU61DSWA F1 EIK01 9999TC EK01 EK01 EIK0 9999TC EK0 EK0 SN0 HSN HSN SN0C HSNC HSNC GTK0 PKGTA1 GTK0C PKOGTC1 ACP4BC HU61DSWC HU61DX HU61RB HU61WA F1 EK61 9999TC EIK01 EK6 9999TC EIK0 HSN SN0 HSNC SN0C GTK0 GTK0C APJ48 ACP4BC HU61WC HU6 HU6A HU6AWA SN06 SN06 SN06 SN06 APJ48 ACP4BC HU6AWC HU6AWH HU6AWK HU6DF F1 9999TC 9999TC SN06 SN06 SN06 HSN HSNC APJ648 SD1781 HU6DS HU6DSWA HU6DSWC HU6DX F1 EK61 EK61 EK61 9999TC EK6 EK6 EK6 9999TC HSN HSN HSNC HSNC PKGTA1 PKOGTC1 ACP4BC APJ648 HU6RB HU6WA HU6WC HU6WH SN06 SN06 ACP4BC APJ648 SD1781 HU6 HU6A HU6AWA HU6AWC SN06 SN06 ACP4CD APJ487 HU6AWK HU6DF HU6DS HU6DSWA 9999TC 01 01 9999TC 0 0 SN06 SN06 HSN HSNC ACP4CD HU6DSWC HU6DX HU6RB HU6WA F1 01 9999TC 0 9999TC SN06 SN06 APJ487 ACP4CD HU6WC HU64 HU64A HU64AWK EK1 EK1 EK1 EK EK EK H0SN H0SN H0SN H0SNC H0SNC H0SNC APJ487 HU64DF HU64DS HU64RB HU6 E1 9999R8 EK1 EK1 9999R9 EK EK H0SN H0SN H0SNC H0SNC Continued on next page

7 11/09 09 Schneider Electric Table 14: Accessories for Current Series Heavy Duty Safety Switches Catalog Number Series Electrical Interlock (1 Contact) Electrical Interlocks ( Contacts) Class R Kits Solid Neutral (Al/Cu) Solid Neutral (Cu Only) Grounding Kit (Al) Grounding Kit (Cu) Fuse Puller Receptacle Plugs HU6AWK HU6DS HU6R HU66 HU66AWK HU66DS HU66R HU67 H800SN HU67AWK HU67R HU68 HU68AWK H800SN H800SN HSN HSN PKOGTA8 PKOGTA8 HU68R HU461 HU461AWK HU461DS E1 EK61 EK61 EK6 EK6 HSN PKOGTA8 PKGTA1 PKGTA1 PKOGTC1 PKOGTC1 HU46 HU46AWK HU46DS HU46 EK61 EK6 PKGTA1 PKOGTC1 HU46AWK HU46DS HU464 HU464AWK EK1 EK1 EK1 EK EK EK HU464DS HU46 HU46AWK HU466 EK1 EK HU661AWK HU661DS HU66AWK HU66DS EK01 EK61 EK0 EK6 PKGTA1 PKGTA1 PKOGTC1 PKOGTC1 HU66AWK HU66DS HU664DS HU664RWK EK1 EK1 EK1 EK EK EK

General Information General Information 8 11/09 UL Listed Maximum Short Circuit Current RatingsAC Only NOTE: Consult the wiring diagram of the switch to verify the UL Listed short circuit current rating. Table : Fusible Short Circuit Current Ratings Heavy Duty Safety Switch UL Listed Short Circuit UL Listed Fuse Class Type Current Ratings H, K ka Fusible R, J, L 0 ka 1 1 On 0 V 0 A switches,,000 A max. on corner grounded delta when protected by Class J or R fuses. Table 16: Non-Fusible Safety Switches Heavy Duty Switch Rating Fuse or Circuit Safety Switch (A) 1 Breaker Type Type -Phase Vac 480 Vac 0 Vac Any brand circuit breaker All H, K Up to ka R,T,J.L 0 ka 0 ka 0 ka H 6 ka ka ka FA 14 ka 14 ka 14 ka Non-Fusible FH 18 ka 18 ka 18 ka Switches 0 H, J 6 ka ka ka 0 KA 0 LA ka ka ka 0 MA 0 KH 0 LH ka ka ka 0 MH 1 Applies to NEMA Types 1, R, 4X stainless, 1 switches. Ampere rating of fuse or circuit breaker not to exceed switch ampere rating. All H and J circuit breakers are acceptable, but will only support the noted Short Circuit Current Rating. Table 17: Terminal Lug Data (NEMA Types 1, R, 4, 4X,, 7, 9, 1) 1 Rating (A) Conductors Per Phase and Neutral Wire Range Wire Bending Space Per NEC Table 1.6 AWG/kcmil Lug Wire Range AWG/kcmil Optional Versa-Crimp Compression Lug Field-Installed 1 1 6 (Al) or 14 6 (Cu) 1 (Al) 14 (Cu) solid or or 14 (Cu) 14 (Cu) stranded 4 14 (Al) or 1 14 (Cu) 1 (Al) or 14 (Cu) 1 1 1/0 (Al) or 14 1/0 (Cu) 1 1/0 (Al) or 14 1/0 (Cu) VCEL0114S1 0 1 6 (Al/Cu) 6 0 (Al/Cu) VCEL016H1 VCEL01H1 1 1/0 7 (Al/Cu) 6 1/0 7 (Al/Cu) or 0 or or and VCEL016H1 7 1/0 0 (Al/Cu) 1/0 0 (Al/Cu) and VCEL01H1 0 /0 0 (Al/Cu) /0 0 (Al/Cu) VCEL01H1 800 /0 7 (Al/Cu) /0 7 (Al/Cu) H8LKE 8 4 /0 7 (Al/Cu) /0 7 (Al/Cu) H1LKE 8 1 A switches suitable for C or C conductors. 0 A switches suitable for o C conductors. For NEMA Types 1 and R only. HU461AWK 14 6 AWG (Cu). 4 HXFA 14 6 AWG (Cu). HXKA 4 AWG 0 kcmil (Cu). 6 Maximum wire range is (1) 0 kcmil or () 0 kcmil Al/Cu on NEMA Type 4X Stainless and NEMA Type 1. 7 Order two PK16KN mounting kits when installing VCEL016H1 lugs. Only one kit is required on two-pole switches. 8 See Digest 1 page 1, 800 and A compression lug kits for additional information. 09 Schneider Electric

General Information Table 18: A Heavy Duty Rating Catalog Number H1DS H1A H1AWK H1N H1NRB H1DS H1A H1AWK H1N H1NRB H61 H61RB H61DS H61A H61AWK H61A H61AWK H61N H61NRB H461 H461DS H461AWK HU61 HU61RB HU61DS HU61A HU61AWK HU461 HU461DS HU461AWK 1 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Series Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. E1 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø 1/ 1/ 1/ 1/ 1/ 1/ 1/ 1-1/ 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1-1/ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Use both outer switching poles. For corner grounded only, install neutral and use switching poles for ungrounded conductors. Standard hp rating. 1 1 1 1 1 09 Schneider Electric 11/09 9

General Information Table 19: A Heavy Duty Ratings Catalog Number HDS HA HAWK HN HNRB HDS HA HAWK HN HNRB H6 H6RB H6DS H6A H6AWK H6N H6NRB H46 H46DS H46AWK HU6 HU6RB HU6DS HU6A HU6AWK HU46 HU46DS HU46AWK HU66DS HU66AWK 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Series Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø 1-1/ 1-1/ 1-1/ 1-1/ 1-1/ 1-1/ 1-1/ 1-1/ 1 1 1 1 1 1 1 1 1 1 4 4 4 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 6 1 Use both outer switching poles. For corner grounded delta only, install neutral and use switching poles for ungrounded conductors. Standard hp rating. 4 hp maximum on a corner grounded delta system. hp maximum on a corner grounded delta system. 6 Use C N.O. 4 Cu or N.O. Al conductors. 1 1 1 1 1 6 6 6 6 6 11/09 09 Schneider Electric

General Information Table : A Heavy Duty Ratings Catalog Number HDS HAWK HA HN HNRB HDS HA HAWK HN HNRB H6 H6RB H6DS H6A H6AWK H6N H6NRB H46 H46DS H46AWK H66DS H66AWK HU6 HU6RB HU6DS HU6A HU6AWK HU46 HU46DS HU46AWK HU66DS HU66AWK Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 6 4 6 6 1 1 1 1 1 1 1 1 1 1 1 6 6 6 6 1 1 1 1 1 6 6 4 6 6 1 Use both outer switching poles. For corner grounded delta only, install neutral and use switching poles for ungrounded conductors. Standard hp rating. 4 Use C No. 1 copper conductor only. hp maximum on corner grounded delta. 6 Use C N.O. 4 Cu or N.O. Al conductors. 09 Schneider Electric 11/09 1

General Information 09 Schneider Electric 11/09 Table 1: 0 A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H4DS H4A H4AWK H4N H4NRB 1 1 H4DS H4A H4AWK H4N H4NRB H64 H64RB H64DS H64A H64AWK 1 1 1 1 1 1 1 1 1 1 H64N H64NRB 1 1 1 1 H464 H464DS H464AWK H664DS H664AWK HU64 HU64RB HU64DS HU64A HU64AWK 1 1 1 1 1 1 1 1 1 1 HU464 HU464DS HU46AWK HU664DS HU664AWK 1 1 1 1

General Information 11/09 09 Schneider Electric Table : 0 A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H HR HDS HAWK HN HNR HNDS HNAWK 1 1 1 1 1 1 1 1 1 1 1 1 H HR HDS HAWK 1 1 1 1 HN HNR HNDS HNAWK 1 1 1 1 H6 H6R H6DS H6AWK 1 1 1 1 1 1 1 1 H6 H6R H6DS H6AWK 1 1 1 1 H6N H6NR H6NDS H6NAWK 1 1 H46 H46AWK HU6 HU6R HU6DS HU6AWK HU6 HU6R HU6DS HU6AWK 1 1 HU46 HU46AWK 1 For corner grounded only, install neutral and use switching poles for ungrounded conductors. Not suitable for use as service equipment.

General Information 09 Schneider Electric 4 11/09 Table : 0 A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H6 H6R H6DS H6AWK 1 1 1 1 0 1 0 1 0 1 0 1 H6N H6NR H6NDS H6NAWK 1 1 1 1 0 1 0 1 0 1 0 1 H6 H6R H6DS H6AWK 0 0 0 0 H6N H6NR H6NDS H6NAWK 0 0 0 0 H66 H66R H66DS H66AWK 1 1 1 1 1 1 1 1 0 1 0 1 0 1 0 1 H66 H66R H66DS H66AWK 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 H66N H66NR H66NDS H66NAWK 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 H466 HU66 HU66R HU66DS HU66AWK HU66 HU66R HU66DS HU66AWK 0 0 0 0 0 0 0 0 0 0 0 0 HU466 1 For corner grounded only, install neutral and use switching poles for ungrounded conductors. Not suitable for use as service equipment.

General Information 11/09 09 Schneider Electric Table 4: 800 A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H7 H7R H6AWK H7N H7NR H7NAWK H7 H7R H7AWK H7N H7NR H7NAWK HN HR HAWK H67 H67R H67AWK 0 0 0 0 0 0 0 0 0 H67N H67NR H67NAWK 0 0 0 0 0 0 0 0 0 HU HUR HUAWK HU67 HU67R HU67AWK 0 0 0 0 0 0 Table : A Heavy Duty Ratings Catalog Number Series 1 Vac Vac 480 Vac 0 Vac Vdc Vac 480 Vac 0 Vac Max. Max. Max. Max. Max. hp Ratings Max. Max. Max. 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Ø Ø Ø Ø Ø Ø H8 H8R H8AWK H8N H8NR H8NAWK H8 H8R H8AWK H8N H8NR H8NAWK H68N H68R H68AWK H68 H68R H68AWK 0 0 0 0 0 0 0 0 0 H68N H68NR H68NAWK 0 0 0 0 0 0 0 0 0 HU68 HU68R HU68AWK HU68 HU68R HU68AWK 0 0 0 0 0 0

General Information Table 6: Catalog Number Specialty Switches 1 Vac Vac 480 Vac 0 Vac Vdc Series Max. Max. Max. Max. Max. hp Ratings 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 Fiberglass Reinforced Polyester EnclosuresNEMA Type 4X H61DF H6DF H6DF H64DF HU61DF HU6DF HU6DF HU64DF F1 F1 F1 E1 F1 F1 E1 E1 Krydon Enclosures H61DX H6DX H6DX HU61DX HU6DX HU6DX F1 F1 F1 F1 F1 F1 1 1 1 NEMA Types 7 and 9 Enclosures HXFA HXFA11 HXFA HXFA11 E1 E1 E1 E1 1-1/ 1 1 1 1 1-1/ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 HXKA C 1 1 1 Use outer switching poles. For corner grounded only, install neutral and use switching poles for ungrounded conductors. hp rating on corner grounded delta system. 4 hp rating on corner grounded delta system. Standard hp rating. 6 Standard hp rating: hp. 7 Standard hp rating: hp. 8 Standard hp rating: hp. 9 hp rating on corner grounded delta system. 1 1 1 1 1 1 1 1 1 1 1 4 1 9 4 1 1 6 7 8 6 11/09 09 Schneider Electric

General Information Table 7: Receptacle Switches Catalog Number H61WA H61DSWA H61AWA HU61WA HU61DSWA HU61AWA H61WC H61DSWC H61AWC HU61WC HU61DSWC HU61AWC H6WA H6DSWA H6AWA HU6WA HU6DSWA HU6AWA H6WC H6DSWC H6AWC HU6WC HU6DSWC HU6AWC H6WH H6AWH HU6WH HU6AWH H6WA H6DSWA H6AWA HU6WA HU6DSWA HU6AWA H6WC H6DSWC H6AWC HU6WC HU6DSWC HU6AWC 1 Vac Vac 480 Vac 0 Vac Vdc Series Max. Max. Max. Max. Max. hp Ratings 1Ø 1Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1Ø Ø 1 0 1-1/ 1 1 1 Use both outer switching poles. Two standard hp rating. Standard hp rating. 4 Fifteen hp maximum on a corner grounded delta system. Not applicable for corner grounded delta. 6 Thirty hp maximum on a corner grounded delta system. 7 Use C N.O. 4 Cu or N.O. Al conductors. 1 1 1 4 1 1 7 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 09 Schneider Electric 11/09 7

General Information 09 Schneider Electric 8 11/09 W W W/H H H W/H D D Typical NEMA Type 1 Typical NEMA Type R Table 8: Dimensions Catalog Number Series Approximate Dimensions H W W/H D in. mm in. mm in. mm in. mm H1N H1NRB HN HNRB 14. 14.88 14. 14.88 71 78 71 78 6. 6.6 6. 6.6 16 168 16 168 7. 7. 7. 7. 19 19 19 19 4.88 4.88 4.88 4.88 14 14 14 14 HN HNRB H4N H4NRB 1. 1. 9. 77 74 8. 8. 17.1 17. 16 16 4 48.. 18. 18.6 470 47 6.8 6.8 8. 8. 16 16 16 H, N HNR, R H6, N H6NR, R..1..1 176 178 176 178 7.6 7.6 7.6 7.6 7 7 7 7 H7, N H7NR, R H8, N H8NR, R 69.1 69.1 69.1 69.1 16 16 16 16 H6 H6R H66 H66R..1..1 176 178 176 178 7.6 7.6 7.6 7.6 7 7 7 7 H HR H68 H68R 69.1 69.1 69.1 69.1 16 16 16 16 H1N H1NRB HN HNRB 14. 14.88 14. 14.88 71 78 71 78 6. 6.6 6. 6.6 16 168 16 168 7. 7. 7. 7. 19 19 19 19 4.88 4.88 4.88 4.88 14 14 14 14 HN HNRB H4N H4NRB 1. 1. 9. 77 74 8. 8. 17.1 17. 16 16 4 48.. 18. 18.6 470 47 6.8 6.8 8. 8. 16 16 16 H, N HR, NR H6, N H6R, NR..1..1 176 178 176 178 7.6 7.6 7.6 7.6 7 7 7 7 H7, N H7R, NR H8, N H8R, NR 69.1 69.1 69.1 69.1 16 16 16 16 H61, N H61- H61NRB, RB 14. 17. 14.88 71 44 78 6. 6.6 16 168 7.. 7. 19 19 4.88 6.8 4.88 14 16 14 H61WA H61WC 18.19 18.19 46 46.. 6.81 6.81 17 17 H6, N H6NRB, RB 17. 17. 44 44.. 6.8 6.8 16 16 H6WA H6WC 18.19 16. 46 4.. 6.81 7.00 17 178 H6WH H6, N H6NRB, RB 18.19 1. 1. 46 8. 8. 16 16... 6.81 6.8 6.8 17 16 16 H6WA H6WC 1.8 1.8 46.. 6.81 6.81 17 17

General Information 9 11/09 09 Schneider Electric W W W/H H H W/H D D Typical NEMA Type 1 Typical NEMA Type R Table 9: Dimensions Catalog Number Series Approximate Dimensions H W W/H D in. mm in. mm in. mm in. mm H64 H64N H64NRB H64RB 9. 9. 77 77 74 74 17.1 17.1 17. 17. 4 4 48 48 18. 18. 18.6 18.6 470 470 47 47 8. 8. 8. 8. 16 16 H6, N H6R, NR H66, N H66NR, R..1..1 176 178 176 178 7.6 7.6 7.6 7.6 7 7 7 7 H67, N H67NR, R H68, N H68NR, R 69.1 69.1 69.1 69.1 16 16 16 16 H461 H46 H46 H464... 1 1 1 77 14. 14. 14.. 91 16.1 16.1 16.1 4.88 4 4 4 6 8. H46 H466 HU6 HU6R..1..1 176 178 176 178.88 7.6 861.88 7.6 861 7 7 7 7 HU66 HU66R HU HUR..1 69.1 69.1 176 178 16 16 7.6 7.6 7 7 HU68 HU68R HU61 H61RB 69.1 69.1 16 16 14. 14.88 71 78 6. 6.6 16 168 7. 7. 19 19 4.88 4.88 14 14 HU6 HU6RB HU6WH HU6 1. 1. 1. 44 8. 8. 8. 16 16 16.... 6.8 6.8 6.8 6.8 16 16 16 16 HU6RB HU64 HU64RB 1. 9. 77 74 8. 17.1 17. 16 4 48. 18. 18.6 470 47 6.8 8. 8. 16 16 HU6 HU6R HU66 HU66R HU67..1..1 69.1 176 178 176 178 16 7.6 7.6 76 7.6 7 7 7 7 HU67R HU68 HU68R 69.1 69.1 69.1 16 16 16 HU461 HU46.. 1 1 14. 14. 16.1 16.1 4 4 6.8 6.8 174 174 HU46 HU464. 1 77 14.. 91 16.1 4.88 4 6 6.8 8. 174 HU46 HU466.. 176 176.88.88 861 861.88.88 861 861 7 7

General Information Table : Dimensions Catalog Number Series Approximate Dimensions H W W/H D W W/H Typical NEMA Types 4, 4X,, 1, and 1K W H Typical NEMA Type 4X Fiberglass Reinforced Polyester and Krydon W H H D D D Typical NEMA Types 7 and 9 H461AWK H461DS H46AWK H46DS H1AWK, A H1DS H1-AWK HAWK, A HDS HAWK, A HDS H4AWK, A H4DS HAWK, DS HNAWK, NDS in. mm in. mm in. mm in. mm..8..8 14. 14.9 16. 14. 14.9..8 46. 46. 1 9 1 9 71 79 419 71 79 1 9 77 77 11 11 14..08 14..08 6.6 7. 6.6 7. 9.6 17. 8 8 168 18 168 18 8 48 6.80 6.80 6.1 6.80 7. 8.67. 7. 8.67. 11. 18.6 19. 17 17 6 17 19 19 86 47 489 6.96 6.96 4.96.11 7.00 4.96.11 7.00 6.97 8. 8.88 177 177 1 1 178 1 1 178 177 16 6 9 9 HXKA C.6 7.88 76.88 76 7. 197 H6AWK, DS H6NAWK, NDS H7AWK, NAWK H8AWK, NAWK H6AWK, DS H66AWK, A, DS HAWK, NAWK H68AWK, NAWK H1AWK, A H1DS HAWK, A HDS HAWK, A HDS H4AWK, A, DS HAWK, DS HNAWK, NDS H6AWK, DS H6NAWK, NDS H7AWK, NAWK H8AWK, NAWK H61AWA H61AWC 46. 46. 69.1 69.1 46. 46. 69.1 69.1 14. 14.9 14. 14.9..8 46. 46. 46. 46. 69.1 69.1 16. 16. 11 11 16 16 11 11 16 16 16 79 71 79 1 9 77 11 11 11 11 16 16 419 419 6.6 7. 6.6 7. 9.6 17. 168 18 168 18 8 48 7. 8.67 7. 8.67. 11. 18.6.. 19 19 86 47 4.96.11 4.96.11 7.00 6.97 8. 7.00 7.00 9 9 9 9 1 1 1 1 178 177 16 9 9 9 9 178 178 H61AWK, A, DS 14. 71 6.6 168 7. 19 4.96 1 H61DF H61DX F1 16. 19. 419 49 11.00 11. 79 90 11.00 11. 79 90 8.80 8. H61-AWK, A 16. 419. 7.00 178 H6AWK, A H6DS H6AWA H6AWC 16. 16.87 16. 16. 419 48 419 419 8.9 7..81.. 7.00 6.97 7.00 7.00 H6AWH 16. 419. 7.00 178 H64, N H64RB, NRB H6, N H6R, NR H66, N H66NR, R H67, N H67NR, R H68, N H68NR, R 9...1..1 69.1 69.1 69.1 69.1 77 74 176 178 176 178 16 16 16 16 17.1 17. 7.6 7.6 46 48 18. 18.6 7.6 7.6 470 47 8. 4 18 178 177 178 178 7 16 7 7 7 7 11/09 09 Schneider Electric

General Information Table 1: Dimensions Catalog Number Series Approximate Dimensions H W W/H D W W/H Typical NEMA Types 4, 4X,, 1, and 1K W H Typical NEMA Type 4X Fiberglass Reinforced Polyester and Krydon W H H D D D Typical NEMA Types 7 and 9 HXFA HXFA H1AWK, A H1DS H1-AWK HAWK, A HDS HAWK, A HDS H4AWK, A H4DS HAWK, DS HNAWK, NDS E1 in. mm in. mm in. mm in. mm.9.9 14. 14.9 16. 14. 14.9..8 46. 46. 71 79 419 71 79 1 9 77 77 11 11 9.87 9.87 6.6 7. 6.6 7. 9.6 17. 1 1 168 18 168 18 8 48 9.87 9.87 7. 8.67. 7. 8.67. 11. 18.6 19. 1 1 19 19 86 47 489 6.96 6.96 4.96.11 7.00 4.96.11 7.00 6.97 8. 8.88 177 177 1 1 178 1 1 178 177 16 6 9 9 HXKA C.6 7.88 76.88 76 7. 197 H6AWK, DS H6NAWK, NDS H7AWK, NAWK H8AWK, NAWK H6AWK, DS H66AWK, A, DS HAWK, NAWK H68AWK, NAWK H1AWK, A H1DS HAWK, A HDS HAWK, A HDS H4AWK, A, DS HAWK, DS HNAWK, NDS H6AWK, DS H6NAWK, NDS H7AWK, NAWK H8AWK, NAWK H61AWA H61AWC H61AWK, A H61DS H61DF H61DX H61-AWK, A H6AWK, A H6DS H6AWA H6AWC H6AWH H64, N H64RB, NRB H6, N H6R, NR H66, N H66R, NR H67AWK, NAWK H68AWK, NAWK F1 46. 46. 69.1 69.1 46. 46. 69.1 69.1 14. 14.9 14. 14.9..8 46. 46. 46. 46. 69.1 69.1 16. 16. 14. 14.9 16. 19. 16. 16. 16.87 16. 16. 16. 9...1..1 69.1 69.1 11 11 16 16 11 11 16 16 16 79 71 79 1 9 77 11 11 11 11 16 16 419 419 71 79 419 49 419 419 48 419 419 419 77 74 176 178 176 178 16 16 6.6 7. 6.6 7. 9.6 17. 6.6 7. 11.00 11. 8.9 17.1 17. 7.6 7.6 168 18 168 18 8 48 168 18 79 90 7 46 48 7. 8.67 7. 8.67. 11. 18.6.. 7. 8.67 11.00 11....81... 18. 18.6 7.6 7.6 19 19 86 47 19 79 90 470 47 4.96.11 4.96.11 7.00 6.97 8. 7.00 7.00 4.96.11 8.80 8. 7.00 7.00 6.97 7.00 7.00 7.00 8. 9 9 9 9 1 1 1 1 178 177 16 9 9 9 9 178 178 1 1 4 18 178 178 177 178 178 178 7 16 7 7 7 7 09 Schneider Electric 11/09 41

General Information Table : Dimensions Catalog Number Series Approximate Dimensions H W W/H D W W/H Typical NEMA Types 4, 4X,, 1, and 1K W H Typical NEMA Type 4X Fiberglass Reinforced Polyester and Krydon W H H D D D Typical NEMA Types 7 and 9 H461AWK H46AWK H46DS H46AWK H46DS H464AWK H464DS in. mm in. mm in. mm in. mm...8..8 1 1 9 1 9 77 77 14. 14..08 14..08.. 8 8 91 16.1 16.1 16.8 16.1 16.8 4.88. 4 4 48 4 48 6 641 6.80 6.80 6.97 6.80 6.97 8. 8.88 17 17 177 17 177 6 H46AWK 46. 11. 86. 86 9 H66AWK H66DS H664AWK H664DS HU6AWK,DS HU66AWK, DS HUAWK HU68AWK HU61AWK, A HU61DS HU61DSWA HU61DSWC HU61DF HU61DX HU6AWH HU6AWK, A HU6DS HU6DSWA HU6DSWC HU6DF HU6DX HU6AWA HU6AWC HU6AWK, A HU6DS HU6DF HU6DX F1 F1 F1..8 46. 46. 69.1 69.1 14. 14.9 16.87 16.87 16. 19. 16. 16. 16.87 16.87 16.87 16. 19.....8 4.80. 1 9 77 77 11 11 16 16 71 79 48 48 419 49 419 419 48 48 48 419 49 1 1 1 9 6 641 14..08.. 6.6 7. 8.9 8.9 11.00 11. 8.9 8.9 8.9 11.00 11. 9.6 1.70 11. 8 91 168 18 7 7 79 90 7 7 7 79 90 8 48 90 16.1 16.8 4.88. 7. 8.67.81.79 11.00 11....81.81.79 11.00 11.... 11. 1.70 11. 4 48 6 641 19 74 79 90 6 74 79 90 86 48 90 6.80 6.97 8. 8.88 4.96.11.11.11 8.80 8. 7.00 7.00 6.97.11.11 8.80 8. 7.00 7.00 7.00 6.97 1.00 8. 17 177 6 9 9 1 1 1 1 4 18 178 178 177 1 1 4 18 178 178 178 177 18 HU64DF E1 1. 79 6. 668 6. 668 11.80 0 HU64AWK, A HU64DS, SS HU6AWK, DS HU66AWK, DS HU67AWK HU68AWK HU461AWK HU461DS HU46AWK HU46DS HU46AWK HU46DS HU464AWK HU464DS 46. 46. 69.1 69.1..8..8..8 77 77 11 11 16 16 1 9 1 9 1 9 77 77 17. 14..08 14..08 14..08 17. 48 8 8 8 48 18.6 19. 16.1 16.8 16.1 16.8 16.1 16.8 18.6 19. 47 489 4 48 4 48 4 48 47 489 8. 8.88 6.80 6.97 6.80 6.97 6.80 6.97 8. 8.88 16 6 9 9 17 177 17 177 17 177 16 6 HU46AWK 46. 11. 86. 86 9 H66AWK H66DS H664AWK H664DS, RWK..8 1 9 77 77 14..08.. 8 91 16.1 16.8 4.88. 4 48 6 641 6.80 6.97 8. 8.88 17 177 6 4 11/09 09 Schneider Electric

Double Throw Safety Switches DOUBLE THROW SAFETY SWITCHES CONTENTS Product Description... 44 Construction... 44 Enclosures... 44 Accessories... 4 Application... 4 Standards... 46 Technical Data... 46 Service Grounding Kit... 49 Solid Neutral Assembly... 49 Electrical Interlocks... 49 Class R Fuse Kits... Lock-On Provision... Rain-Proof Bolt-On Hubs... Watertight Hubs... Dimensions... 1 09 Schneider Electric 11/09 4

Double Throw Safety Switches Product Description Double throw safety switches are designed to transfer a load from one power source to another power source. A F Series switches can be field-converted to transfer a power source from one load to another. Construction A DT, DTU (Series F) NEMA Type 1 Modular-design switch handle, lock -plate, and switch mechanism; line and load bases are available for field replacement Meets NEMA hp ratings UL Listed short circuit current ratings up to 0 ka (using Class R, J, or T fuses see UL Listed Short Circuit Current Ratings table on page 4) UL Listed as suitable for use as service equipment Fusible and non-fusible switches available May be padlocked in the ON or OFF position Padlock provisions in the center OFF position on 8,000, 9,000, DT, and DTU lines Padlock provisions in both ON positions on 9,000 line Visible blades for positive indication that the switch is OFF Electrical interlock and neutral assembly (for two- and three-pole switches) kit is available for field-installation Quick-make, quick-break operating mechanism on F Series, 8,000, DT, and DTU lines. Load make/break Slow-make, slow-break operating mechanism on 9,000 line. Non-load make/break Lugs suitable for aluminum or copper conductors. See page 46 for additional lug data Dual cover interlock on DT and DTU F Series and NEMA Type 1 8,000 line E Series devices, with defeat mechanism NEMA Type R top endwalls on 0 A switches have bolt-on hub provisions Tangential knockouts alleviate the need for conduit offsets or bends Type 4 Stainless Steel (NEMA Types 4, 4X, and ) Enclosures Indoor general purpose (NEMA Type 1) Outdoor general purpose (NEMA Type R) Indoor dusttight, driptight (NEMA Type 1) Indoor, outdoor watertight, dusttight (NEMA Types 4, 4X, and ) Gray baked enamel finish electrodeposited on clean, phosphatized steel (NEMA Types 1, R, and 1) 8,000 Line NEMA Type 1 44 11/09 09 Schneider Electric