Commercial Products. Pumps Controls Pressure Boosting BRGLCAR R1

Similar documents
Commercial Products PUMPS CONTROLS PRESSURE BOOSTING BRGLCAR R4

ITT. Goulds Pumps G&L Series Commercial Products. Engineered for life. Commercial Water. Goulds Pumps is a brand of ITT Corporation.

Variable Speed Product Line

Hydrovar and Packaged Hydrovar

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

Aquavar ABII TECHNICAL BROCHURE BAQUABII R2 VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

BSPDDRIVE ITT. Goulds Pumps. Aquavar SPD (Single Pump Drive) Simplex Variable Speed Pump Controller

AquaBoost. Variable Speed Constant Pressure Systems MODEL ABS

AQUAVAR AQUAVAR 56 AQUAVAR CPC

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications.

TECHNICAL BROCHURE BSPMSPH R1 SOLD SEPARATELY OR BUILT IN. PrimeLine SP SPM & SPH SERIES

AquaBoost Packaged Systems

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

TECHNICAL BROCHURE B5-33GB R4 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

General Catalog. A New Vision for Quality Pumps. General Catalog

e-hm REPAIR PARTS REPAIR PARTS ReHM R1

5GB, 7GB, 10GB, 18GB, 25GB, 33GB

DPS. The SSV Dual Pump System

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

ITT. Goulds Pumps. G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps. Engineered for life. Commercial Water.

ITT. Goulds Pumps G&L Series NPO. Engineered for life. Commercial Water. Open Impeller All Stainless Steel End Suction Pumps.

ITT. Goulds Pumps. 5GB, 7GB, 10GB, 18GB, 25GB, 33GB High Pressure Multi-Stage Booster Pump. Engineered for life. Residential Water Systems FEATURES

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

TECHNICAL BROCHURE B45-70HB R2 45HB, 70HB HIGH PRESSURE CENTRIFUGAL BOOSTER PUMP

33GS, 40GS, 55GS, 60GS, 75GS & 80GS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

5LS, 7LS, 10LS, 13LS, 18LS & 25LS 5-25 GPM, ½ 1½ HP, 60 HZ, SUBMERSIBLE PUMPS

100H, 150H, 225H, 275H

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

VERTICAL MULTI-STAGE PUMPS

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

Hydropak Booster Systems. Series motralec

5CS, 7CS, 10CS, 13CS, 18CS & 25CS 5-25 GPM, ½ 3 HP, 60 HZ, SUBMERSIBLE PUMPS

Axial and Mixed Flow Pumps for Large Volume Pumping

Peerless Pump FULL PRODUCT LINE. Brochure B Sterling Fluid Systems (USA), Inc.

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

J1000. Compact Inverter Series.

BOOSTER PUMPS PRODUCT FAMILY APPLICATIONS FAMILY COMPARISON CHART

Description 1/8-7.5HP

5GS, 7GS, 10GS, 13GS, 18GS & 25GS 5-25 GPM, ½ 5 HP, 60 HZ, SUBMERSIBLE PUMPS

High Capacity Centrifugal & Sprinkler Pumps

TECHNICAL BROCHURE B5-18SB R1 5SB, 7SB, 10SB & 18SB 5-18 GPM, ½ 1½ HP, 60 HZ SUBMERSIBLE PUMPS

HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

VERTICAL MULTI-STAGE PUMPS

AQUAVARTM 56 HYDROVIEW. Pumping System Controllers FILL VENT MAX. MAX. 3 4 NPT

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

INSTRUCTION MANUAL ADDEN600V R1 AQUAVAR CPC. (Centrifugal Pump Control) 600 VOLT ADDENDUM

TECHNICAL BROCHURE B5-75GSX. GS-CBM GS Xtreme 60 HZ, 4" SUBMERSIBLE PUMPS

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

TW G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

AQUAVAR AQUAVAR VARIABLE SPEED SYSTEM CONTROLLER. Applications. Specifications. Benefits of using Aquavar

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

4" Motors and Controls

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

GRUNDFOS PRODUCT GUIDE. Hydro Solo-E. Grundfos Hydro Solo-E booster sets 60 Hz

Wilo Price Book. Pumps and systems for Building Services and Groundwater. Pioneering for You USA 60 Hz.

700 KVA / 550 KW POWERED by

GB REPAIR PARTS REPAIR PARTS RGB R2

HVAC Products. Introducing the SED2 Variable Frequency Drives

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

GS Series. with new controller SM30

Series. NV Vertical Multistage Booster Pump

INDUSTRIAL PRODUCTS 2010 CATALOG

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Wilo CO-Helix Pressure Boosting Systems. Engineering Specification

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Regenerative Turbine Pumps

Webtrol s Family of Pumps

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

TECHNICAL BROCHURE BAC2000. Series 2000 Closed Coupled. Series 2000 Frame Mounted. Series A-C 2000 SINGLE STAGE END SUCTION

3x3x7B Series 80 In-Line Mounted Centrifugal Pumps

RVS-DN Digital Reduced Voltage Motor Starter

UD SERIES COMPRESSORS

SUBMITTAL SAVCPC AQUAVAR CPC. (Centrifugal Pump Control)

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

DuraMACTM Booster Pumps

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Regenerative Turbine Pumps

GB REPAIR PARTS REPAIR PARTS RGB R3

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

RVS-DX Digital Reduced Voltage Motor Starter

RS Series Multi-stage, Ring Section Pump For Pressures to 1,500 PSI

TW1000E-20W-70-DCA In Enclosure w/ Double Check Assembly VARIABLE SPEED BOOSTER SYSTEM

PRODUCT CATALOG SOLAR PRODUCTS. franklinwater.com

EZ SERIES BOOSTER PUMPS

INLINE 1100 STAGED PALLET SYSTEM. franklinwater.com

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

PumpSmart. Control Solutions

640 KW / 800 KVA POWERED by

1800 KW / 2250 KVA POWERED by

Transcription:

Commercial Products Pumps Controls Pressure Boosting BRGLCAR R1

Proven Performance Through The Power Of Experience. combines over 155 years of pump experience with the most modern design and manufacturing systems deep drawn metal fabrication, laser cutting, laser welding, precision casting, and worldwide design systems plus a total commitment to quality based on full performance testing of every pump we make. Whether you need stainless steel, bronze, or cast iron, multi-stage verticals or horizontals, end suction centrifugals or submersibles, there s a Goulds Water Technology design that s proven itself through years of dependable service. For booster service, liquid transfer, spray systems, water circulation, dewatering, light chemical and industrial applications, there s a pump that s done long time duty. Horizontal and vertical multi-stage capacities from 5 gpm to 35 gpm. Submersible capacities from 5 gpm to 5 gpm. And end suction centrifugal capacities from 4 gpm to 5 gpm. a brand offering the power of experience to more than 1 nations of the world. In addition to the standard pump designs shown here, we offer specialized O.E.M. pumps designed to meet the specifications of your particular needs. TABLE OF CONTENTS End Suction, Stainless Steel: NPE...3 NPO...3 MCS...3 SSH...4 ICS/ICS-F...4 3657/3757...4 LB...5 End Suction, Cast Iron: 3642/3742...5 MCC...5 3656LH/3756LH...5 3656/3756 S-Group...6 3656/3756 M&L-Group...6 Self Priming, Clear Liquids: PrimeLine SP...7 GT IRRI-GATOR...8 PrimeLine...8 2AUW, 3AUW...9 High Pressure, Stainless Steel: e-sv...9 LC... 1 HMS... 1 High Pressure, Cast Iron: GB... 1 HSC... 1 Vertically Immersed: NPV... 11 Multi-Stage: MPVN... 12 SMVT... 13 Variable Speed Control: Hydrovar and Aquavar CPC... 14 Aquavar ABII... 14 Packaged Pump Systems: AquaForce... 15 Controls: Hydrovar... 16 Aquavar CPC... 17 Aquavar S-Drive... 18 Aquavar ABII... 19 PAGE 2

End Suction Stainless Steel A full range of end suction centrifugal pumps. Cast iron, bronze, investment cast 316 stainless steel and 34 stainless steel pump-end materials of construction. 1 x 1 1 4-5 through 8 x 1-13 sizes. Close coupled, frame mounted or engine drive configuration. Capacities to 45 US- GPM (1 m 3 /hr.). Heads to 5 ft. TDH (152 m). Working pressure to 25 PSI. Temperatures to 25º F. (12º C.). ANSI Flanged and NPT Connections. Motors 1 & 3 phase. 5 or 6 hertz ODP, TEFC or explosion proof enclosures 35 & 175 RPM. Standard John Crane mechanical seals with high temperature and chemical duty options. NPE 316L Stainless Steel Enclosed Impeller NPO 316L Stainless Steel Open Impeller METER 5 4 3 2 1 16 14 12 1 8 6 4 3 25 2 15 1 5 12 1 8 6 4 1ST 1" x 1 1 4" 6 1 2 3 HP 35 RPM 1ST 2 175 RPM 2ST 175 RPM 2ST 1 1 4" x 1 1 2" 6 3 4 5 HP 35 RPM 3ST 175 RPM 3ST 1 1 2" x 2" 6 1 5 HP 35 RPM 2 4 6 8 1 12 14 16 U.S. GPM 5 1 15 2 25 3 35 m 3 /hr 1" x 1 1 /4" 6 35 RPM 1 1 /4" x 1 1 /2" 6 35 RPM 1 1 /2" x 2" 6 35 RPM 2 1 1 /2" x 2" 6 175 RPM 1" x 1 1 /4" 6 175 RPM 1 1 /4" x 1 1 /2" 6 175 RPM 25 5 75 1 125 15 175 2 225 U.S. GPM 25 5 1 15 2 25 3 35 4 45 5 m 3 /hr MCS 34L Stainless Steel Enclosed Impeller 5 16 4 14 H 3 2 12 1 8 6 1MS 1" x 1 1 4" 6 1 2 3 HP 35 RPM 2MS 1 1 4" x 1 1 2" 6 3 4 5 HP 35 RPM 3MS 1 1 2" x 2" 6 1 5 HP 35 RPM 1 4 2 2 4 6 8 1 12 14 16 U.S. GPM 5 1 15 2 25 3 35 m 3 /hr Q PAGE 3

End Suction Stainless Steel ICS/ICS-F Investment Cast 316 Stainless Steel Open Impeller 3657/3757 Investment Cast 316 Stainless Steel Enclosed Impeller 3757 ICS-F ICS METERS 3 3657 35 RPM 8 125 24 (H) 3 2 1 1 75 5 1 x 1 1 4 5 35 RPM 1 SS 1 1 4 x 1 1 2 5 35 RPM 2 SS 25 1 x 1 1 4 5 175 RPM 1 SS 1 1 4 x 1 1 4 5 175 RPM 2 SS 2 4 6 8 1 12 U.S. GPM (H) 6 4 2 18 12 6 1 1 2 x 2 6 3 SS 1 1 2 x 2 8 5 SS 2 x 3 7 4 SS 1 2 3 4 5 U.S. GPM 1 2 (Q) 3 m 3 /h 2 4 6 8 1 (Q) 12 m 3/h SSH 316L Stainless Steel Enclosed Impeller 175 6 35 RPM 15 175 RPM 15 5 4 125 125 1 75 5 25 4 24SH 3 11ASH 2 1ASH 7SH 9ASH 1 4SH 8SH 5SH 25SH 27SH 22SH 6SH 23SH 28SH 3 2 1 1 75 24SH 11ASH 5 1ASH 7SH 25 9ASH 25SH 8SH 5SH 4SH 6SH 27SH 22SH 23SH 28SH 1 2 3 4 5 6 7 8 9 1 11 12 U.S. GPM 2 4 6 8 1 12 14 16 18 2 22 24 26 m 3 /hr 1 2 3 4 5 6 7 U.S. GPM 8 2 4 6 8 1 12 14 16 m 3 /hr 18 PAGE 4

End Suction Stainless Steel and Cast Iron LB 34 Stainless Steel Enclosed Impeller 3642/3742 Cast Iron Enclosed Impeller, Iron, Bronze or Bronze Fitted, Cast Iron Pump METERS PSI (H) 5 4 3 2 1 8 7 6 5 4 3 2 1 18 16 14 12 1 8 6 4 2 2 4 8 16 6 1 12 14 18 2 22 U.S. GPM 1. HP.75 HP.5 HP 5 NPSH 2% EFF 25% 1 3% 1 2 3 4 5 (Q) 32% 2 33% 34% MODEL: LB SIZE: 1 x 1 1 4 RPM: 35 m 3 hr 6 5 4 3 2 1 2 18 16 14 12 1 8 6 4 2 1 x 1 1 4-5 1 1 4 x 1 1 2-5 35 RPM U.S. 2 4 6 8 1 12 GPM 5 1 15 2 25 m 3 /hr FLOW RATE MCC Enclosed Impeller Iron Casing Stainless-Fitted 3656LH/3756LH Enclosed Impeller Low Head, Bronze Fitted 6 5 16 5 H 4 3 2 1 14 12 1 8 6 4 2 1MC 1" x 1 1 4" 6 1 2 3 HP 35 RPM 2MC 1 1 4" x 1 1 2" 6 3 4 5 HP 35 RPM 3MC 1 1 2" x 2" 6 1 5 HP 35 RPM 2 4 6 8 1 12 14 16 18 2 22 U.S. GPM 4 45 5 5 1 15 2 25 3 35 m 3 /hr Q 4 3 2 2 x 2 5 35 RPM 2 1 2 x 2 1 2 5 35 RPM 3 x 3 5 35 RPM 4 x 4 5 35 RPM 5 x 5 6 35 RPM 4 x 4 5 175 RPM 1 5 x 5 6 175 RPM 3 x 3 5 175 RPM 2 x 2 5 175 RPM 2 1 2 x 2 1 2 5 175 RPM 1 2 3 4 5 6 7 8 9 1 U.S. GPM PAGE 5

End Suction Cast Iron 3656/3756 S-Group Enclosed Impeller Iron, Bronze or Bronze Fitted Mechanical Seal or Packing METERS 15 9 75 6 45 3 15 35 3 25 2 15 1 1 /2 x 2-8 1 x 2-8 1 2 2 x 2 1 /2-7 2 1 /2 x 3-7 1 3 x 4-7 1 1 /2 x 2-6 1 x 2-7 2 x 2 1 /2-7 5 2 x 2-5 3 x 3-5 2 1 /2 x 2 1 /2-5 3 4 4 x 4-5 5 6 5 x 5-6 7 1 x 2-7 (35) 1 x 2-8 (35) 1 1 /2 x 2-6 (35) 1 1 /2 x 2-8 (35) 2 x 2-5 (35) 2 1 /2 x 2 1 /2-5 (35) 2 1 /2 x 3-7 (35) 3 x 3-5 (35) 3 x 4-7 (35) 4 x 4-5 (35) 5 x 5-6 (35) 2 x 2 1 /2-7 (175) 2 x 2 1 /2-7 (35) 8 9 U.S. 1 GPM 25 5 75 1 125 15 175 2 225 m 3 /hr 8 175 RPM 3656 1 6 4 1x2 8 1x2 7 1 1 2x2 8 2 2 1 2x3 7 3x4 7 3756 1 1 2x2 6 / 1 1 2x2 6H 5 1 15 2 25 3 U.S. 35 GPM 1 2 3 4 5 6 7 m 3 /hr 8 3656/3756 M & L-Group Enclosed Impeller Cast Iron or Bronze Fitted Mechanical Seal or Packing METERS 14 12 1 8 6 4 2 5 4 3 2 1 1 1 /2 x 2-1 35 RPM 1 1 /4 x 1 1 /2-9 1 /2 35 RPM 3 x 4-8 35 RPM 25 2 1 /2 x 3-1 35 RPM 2 1 /2 x 3-9 35 RPM 5 x 6-7 175 RPM 5 3 x 4-1 35 RPM 4 x 6-13 175 RPM 75 4 x 5-8 35 RPM 4 x 6-1 175 RPM 6 x 8-9 1 /2 175 RPM 1 4 x 6-16 175 RPM 5 x 6-7 35 RPM 6 x 8-13 175 RPM 5 1 15 2 25 3 4 5 75 1 125 1 1 /2 x 2-1 (35) 2 1 /2 x 3-9 (35) 2 1 /2 x 3-1 (35) 3 x 4-8 (35) 3 x 4-1 (35) 4 x 5-8 (35) 4 x 6-1 (175) 4 x 6-13 (175) 4 x 6-16 (175) 6 x 8-13 (175) 8 x 1-13 (175) 1 1 /4 x 1 1 /2-8 1 /2 (35) 5 x 5-7 (175) 5 x 6-7 (35) 6 x 8-9 1 /2 (175) 15 8 x 1-13 175 RPM 3 U.S. 45 GPM m 3 /hr METERS 9 8 7 6 5 4 3 2 1 3 25 2 15 1 5 3756 SAE 1 1 /2 x 2-1 2 1 /2 1 1 x 3-9 /4 x 1 1 /2-9 1 /2 2 1 /2 x 3-7 2 x 2 1 /2-7 3 x 4-8 2 1 /2 x 3-8 2 1 /2 x 3-13 2 1 /2 x 3-1 3 x 4-1 3756 1 1 /2 x 2-1 (175) 2 1 /2 x 3-8 (175) 2 1 /2 x 3-9 (175) 2 1 /2 x 3-1 (175) 2 1 /2 x 3-13 (175) 3 x 4-8 (175) 3 x 4-1 (175) 2 x 2 1 /2-7 (175) 1 1 /4 x 1 1 /2-9 1 /2 (175) PAGE 6 3656 Close Coupled 1 2 3 4 5 2 4 6 8 1 12 U.S. 6 GPM m 3 /hr

Self Priming Clear Liquids General information on Self-Priming pumps. PrimeLine SP Enclosed Impeller, Bronze Fitted General water handling in applications where the liquid level is below the pump. Models are available with electric motor, or bearing frame depending on installation requirements. Ideal for irrigation, emergency cellar draining and farm water supply. 16 PRIMELINE SP 3 HP HIGH HEAD CURVE No. CN681R1 4 14 12 PRIMELINE SP 3 HP MEDIUM HEAD CURVE No. CN683R 3 1 12 8 3 1 2 TDH 8 TDH 6 2 6 4 4 1 1 2 2 15 1 5 2 25 2 15 1 5 2 4 6 8 1 12 14 US GPM 2 4 6 8 1 12 14 16 18 2 US GPM 5 1 15 2 25 3 m 3 /hr 25 35 5 1 15 2 3 4 m 3 /hr METERS 5 4 18 PRIMELINE SP 5 HP HIGH HEAD CURVE No. CN682R1 16 14 16 PRIMELINE SP 5 HP MEDIUM HEAD CURVE No. CN684R 4 14 12 12 3 1 3 1 TDH 8 TDH 2 8 2 6 6 1 4 25 2 15 1 5 1 4 2 2 25 2 15 1 5 US GPM 14 16 2 4 6 8 1 12 18 US GPM 14 16 1 18 22 2 4 6 8 12 2 24 1 2 3 4 m 3 /hr 3 35 4 45 5 1 15 2 25 5 m 3 /hr PAGE 7

Self Priming Clear Liquids GT Irrigator Enclosed Impeller Irrigation Duty METERS 4 12 (H) 3 2 1 1 8 6 4 2 25' 2' 25' 15' 25' 25' 2' 15' 2' 25' 2' 2' 1' 15' 15' 1' 1' 1' 1' 5' GT1 5' 5' 5' 5' GT7 GT15 GT2 GT3 15' 1 2 3 4 5 6 7 8 9 1 11 U.S. GPM 5 1 15 2 25 (Q) m 3 /hr PrimeLine Self-Priming Centrifugal Pumps 1 METERS 8 3 NEW PRIMELINE HYDRAULICS COVERAGE M 5 FT. 15 TOTAL HEAD 6 4 2 1 2P4 3P3 3P4 4P1 & 4P2 TOTAL HEAD 4 3 2 1 4E1 6E2 2 2P3 2P2 2P1 3P1 3P2 1 5 6E1 PAGE 8 1 2 3 4 5 6 7 8 IN U.S. GPM 2 4 6 8 1 12 14 16 18 IN CUBIC METERS PER HOUR GPM m 3/h 5 1 15 2 1 2 3 4 5 Frame-Mounted Only

Self Priming Solids 2AUW, 3AUW Portable Contractor Pumps 2AUW 3AUW 12 12 1 1 HEAD TDH () 8 6 HEAD TDH () 8 6 4 4 2 2 4 8 12 16 17 FLOW (GPM) 25 5 75 1 125 145 FLOW (GPM) High Pressure Stainless Steel General information on high pressure multi-stage pumps. Stainless steel or cast iron pumps for pressure boosting. Applications: potable water, boiler feed, filtration, RO and Pure Water Increased range coverage with new e-sv sizes Increased efficiency Improved serviceability - fast easy seal replacement without removing the motor Compatible with the Hydrovar or Aquavar CPC Variable Speed Pump Controllers Flows to 75 GPM, Heads to 115 e-sv Vertical Multi-Stage Pumps 3 75 5 25 12 35 3 1 25 2 15 1 5 25 2 15 1 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 GPM 8 6 4 2 1SV 3SV 1 2 4 6 8 1 15 2 3 4 6 8 1 14 m 3/h 1SV 5SV 3SV 1SV 15SV 5SV 22SV 33 SV 46 SV 1SV 15SV 66 92 SV SV 22SV 125SV 175 RPM 35 RPM 33SV 46 SV 66 SV 92 SV 125SV 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 GPM 1 2 4 6 8 1 15 2 3 4 6 8 1 14 m 3/h PAGE 9

High Pressure Cast Iron / Stainless Steel LC 34 Stainless Steel HMS 316L Stainless Steel METERS 7 6 5 4 3 2 1 EFF. % 2 15 1 5 5 4 3 2 1 5 3 16" DIA. (ALL MODELS) LCA EFF. 1 2 LCA LCA NPSH 3 LCB EFF. 4 LCB NPSH 5 LCB 6 MODEL LC CURVE CN466R 355 RPM 7 LCC EFF. LCC NPSH 8 LCC NPSHr (ft) 25 2 15 1 5 9 US GPM 35 1 9 3 8 7 6 5 4 3 2 1 25 2 15 1 5 1HMS5 1HMS4 1HMS3 1HMS2 1HMS 2HMS5 2HMS4 2HMS3 2HMS2 1HMS 5 1 15 2 25 3 35 MODEL HMS SIZE: AS SHOWN RPM 35 CURVE: CF375R 2HMS 2HMS 4 US GPM 6 4 2 1 8 6 4 2 EFF. % NPSH (ft) 5 1 15 2 m 3 /hr 1 2 3 4 5 6 7 8 9 m 3 /hr 1 GB Cast Iron or 34 Stainless Steel HSC Cast Iron METERS PSI 25 15 5 2 4 15 1 3 1 2 5 5 1 5GB 7GB 1GB 18GB RECOMMENDED RANGE 1 43 GPM 33GB 25GB MODEL: GB RPM: 35 BASED ON ZERO INLET PRESSURE CURVE NO. CN434R2 NPSH R 25 2 15 1 5 24 HSC3 7 22 HSC2 2 6 18 HSC15 5 16 HSC1 14 4 HSC7 12 3 1 8 2 6 4 1 2 6' NPSH R 7' 12' 15' MODEL HSC SIZE 3 /4 3 HP RPM 35 5 1 15 2 25 3 35 4 45 5 U.S. GPM 1 2 3 4 5 6 U.S. GPM 1 2 3 4 5 6 7 8 9 FLOW RATE 1 11 12 M 3 /Hr. 2 4 6 8 1 12 14 16 m 3 /hr PAGE 1

Vertically Immersed NPV General information on Vertical Immersed pumps. Vertically Immersed End-Suction Pump 34 and 316 stainless steel pumps for machine tool, wash system and tank mount applications. Pump head is immersed in pumped liquid. May be set at various depths depending on tank. Single stage and high pressure multistage versions are available. 5 16 (H) 4 3 2 1 14 12 1 8 6 4 1 x 1 1 /4 6 1 /2-2 HP 35 RPM 1SL 1 1 /4 x 1 1 /2 6 3 /4-5 HP 35 RPM 2SL 1 1 /2 x 2 6 1-5 HP 35 RPM 3SL 2 1SL 175 RPM 2SL 175 RPM 3SL 175 RPM 2 4 6 8 1 12 14 16 U.S. GPM 5 1 15 2 25 3 35 m 3 /hr (Q) PAGE 11

Vertical High Pressure MPVN Rugged vertical segmented ring construction. Available in all iron, stainless fitted or all stainless for fluid compatibility. Recommended for a wide variety of industrial, commercial, municipal and building trades pressure boosting applications. Vertical High Pressure Multi-Stage Pump TOTAL HEAD H (ft.) Q [m3/h] 3 4 5 6 7 8 9 1 15 2 3 4 5 1 15 2 3 4 5 16 52 355 RPM 15 14 13 48 44 4.2 125.2 4 12 36 11 4.3 1.1 1 125.1 32 9 65.1 65.2 28 8 24 7 6 5 4 3 1.2 2 16 12 8 2 1 4 15 2 3 4 5 1 15 2 3 4 5 1 [I.G.P.M.] 15 2 3 4 5 1 15 2 3 4 5 1 [US.G.P.M.] Q H [m] Q [m3/h] 2 3 4 5 1 2 3 4 5 1 2 3 5 1 15 5 15 1 175 RPM 4 3 TOTAL HEAD H (ft.) 5 4 3 2 4.2 4.3 65.1 65.2 1.1 125.1 1.2 125.2 2 1 5 H [m] 4 1 3 1 15 2 3 4 5 1 2 5 1 2 2 3 [I.G.P.M.] 1 15 2 3 4 5 1 2 5 1 Q 2 3 [US.G.P.M.] PAGE 12

Vertical High Pressure SMVT Surface mounted, multi-stage vertical turbine pumps. Turbine hydraulics, in-line configuration. Surface Mount Vertical Turbine High efficiency, high pressure design. Heavy duty cast iron stainless steel fitted bowl assembly. Motor coupling is precision balanced for vibration-free operation. Ideal for limited space environments, packaging, and water booster applications. Flows from 5 to 85 GPM. TDH up to 88 feet. Pre-engineered product with construction options such as stainless steel flanged casing, 5Hz or Premium efficiency motors, and horizontal configurations. Unit can be serviced without disturbing system piping arrangement. Mechanical cartridgetype seal can be replaced without removing motor. METERS 3 25 2 15 1 5 1 9 8 7 6 5 4 3 2 SM1 SM2 SM3 SM4 SM5 35 RPM SM6 1 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 GPM 2 4 6 8 1 12 14 16 18 2 m3/hr PAGE 13

Variable Speed Control General information on Variable Speed Control systems. Aquavar pump control for constant pressure, constant flow, or system curve performance. Versions from 1 HP to 55 HP. Pump or wall mounted. Any three phase centrifugal pump motor (23/46 V). Eliminate large pressure tanks, separate control panels, bypass lines, automatic valves, etc. Up to four pumps can be linked for automatic alternation. Aquavar ABII constant pressure system provides constant water pressure for homes and commercial properties, up to 1 GPM systems. Automatically changes pump speed based on water demand. Complete with all needed components for installation. 1 to 5 HP available. Hydrovar and Aquavar CPC Centrifugal Pump Controller, PLC and Variable Frequency Drive Adjustable to match system curve (ft.) Automatic pump shut off at zero consumption Up to 7% energy saving at partial load KILOWATTS 6 5 4 3 2 1 35 RPM PUMP CURVE 12 1 8 6 4 2 25% 5% 75% 1% (gpm) 125% Automatic start of 2-4 pumps at peak demand Constant speed pump power requirement AQUAVAR PAGE 14

Engineered Pump Stations AquaForce Features and Specifications All systems are CUL Listed. NSF61 approved for potable water. Maximum footprint, on most sizes, allow systems to fit through standard doorways. 2 23 Volt single phase, 2 23 Volt three phase, 46 Volt. Each system is fabricated with stainless steel or cast iron centrifugal pumps with a variety of electrical and mechanical options to choose from. Standard off the shelf motors by Baldor or USEM Motors. Significant reduction in energy consumption over fixed speed systems. System protection from overvoltage, under-voltage, blocked suction, cavitation, NPSHa, phase loss, short circuit, transducer failure and motor overload. Liquid temperatures up to 212º F. Ambient temperatures up to 14º F. Maximum operating pressures up to 36 psi. Pump run-out protection. Dry running protection. Programmable lead/ lag alternation. Programmable system curve/ friction loss compensation. Programmable system pressure starting. Fault detection and alarms relay. Motor run relay. Programmable soft start. Stainless steel or optional carbon steel piping. Isolation valves. Optional suction / low pressure switch. Optional pressure relief valves and temperature relief valves. Optional lightning protection. Optional flexible discharge hose. Engineered Pump Stations PAGE 15

Commercial Water Variable Speed Control Hydrovar Available Configurations Horsepower Range Electrical Requirement 2 and 3 1 phase, 23 V 3, 5, 7½, 1, 15 3 phase, 46 V Pump Mounted Variable Speed Controller Packaged Hydrovar NOTE: Pressure Transducer, fused disconnect, complete wiring and conduit included. PAGE 16 Technical Data Single Phase Version: 2 and 3 HP Motor Rating: 3 phase, TEFC, 28 23 volt, 6 HZ, Class F insulation Power Supply: single phase input, 22 24 volt, ±1%, 4 7 HZ Three Phase Version: 3 HP to 15 HP Motor Requirements: 3 phase, TEFC, 46 volt, ±1%, 6 HZ, Class F insulation Power Supply: 3 phase, 38 46 volt, ±1%, 4 7 HZ Pressure Transducer: 316 SS, 17-4 PH stainless steel, 1 4 NPT connection, shielded two wire cable, operating temperature 13º F to 25º F, supply voltage 7-35 Vdc, 4 2mA output. Accuracy is.5% of full scale, proof pressure is 4 x full scale. Display: Two line, 16 characters per line, LCD display. Easy to read pump language, pump on, system pressure, fault codes and system conditions are displayed. Motor Speed: Variable between 7 HZ, or maximum RPM at 6 HZ depending on speed rating of standard AC induction motor. Ambient Temperatures (operating): 32 14º F ( 4º C) Humidity: 5% relative at 14º F (non-condensing) 9% relative at 68º F (non-condensing) Inverter design: IGBT, output frequency is a sinus valuated Pulse Width Modulated (PWM) Enclosure: NEMA 4, IP 55. Avoid excessive dust, corrosives or salts. Safety Agency Listings: Packaged Hydrovar U, C L US Hydrovar only (UL Recognized Component) C US Protection: Over/Under voltage, motor overload, short circuit, ground fault, motor overheat (with thermistor), programmable no/low flow shut-down, low suction pressure, pump run-out. Control: Analog input control (4 2mA) two point control based on pressure, flow or differential pressure. Control up to 8 pumps in parallel. Terminals: Dry relay contacts are available for pump run, pump error, low pressure switch, remote ON/OFF control, analog output 1 Vdc (system pressure) and full opened slave pump starter. Multi-Pumps: RS485 communication SIO (local only) up to four pumps. Alternate Input: Up to two transducers may be used with each controller. These may be pressure, flow, differential pressure, temperature or other 4 2mA signals. Hydrovar Variable Speed Pump Controller The HYDROVAR Pump controller is a combination of a variable frequency motor drive (VFD) and a programmable logic controller (PLC) in one compact package. It mounts on the fan cover of the TEFC pump motor. Each controller is pre-programmed with patented pump specific software. Controllers are specifically designed to work with all configurations of centrifugal pumps, matching pump output to varying system conditions while protecting the pump, the motor and the pumping system.

Variable Speed Control Aquavar CPC Introduction Wall Mounted Version The Aquavar CPC (Centrifugal Pump Controller) from CentriPro incorporates the latest state-of-the-art Aquavar technology. The Aquavar CPC is a variable frequency drive and pump specific PLC in one compact unit, that will vary the speed of the motor to maintain a consistent pressure, flow, temperature or level. Here are just a few of the features and benefits of this innovative product: Start-up wizards expedite the programming process. Removable control panel/display. Fully backlit display with large text makes the control pad easy to read. Transducer assembly (-3 psi) included for constant pressure. Protect the pump from cavitation, dead head and blocked suction. Protect the motor from short circuit, phase loss, overload, undervoltage, overvoltage. Input choke reduces harmonics and provides 3-5% impedence line reactor. EMC/RFI filters reduce drive noise emissions and interference. MODBUS compatible. MODBUS is standard protocol with SCADA networks. Capable of controlling up to 3 fixed speed pumps, with one drive. Multipump control for up to 4 pumps, without additional PLC s or control panels. Auto lead/lag and switching control built in. Ratings and Enclosures NEMA 1 (indoor use) standard. Other enclosures available upon request. 1 2 HP (frame R1 R6) wall mounted. 25 55 HP (frame R7 and R8) floor mounted. Ambient temperature 5º F 14º F. Higher temperatures can be achieved using optional enclosure upgrades and derating factor for up to 122º F. At altitudes from to 33 feet rated current is available, for every 328 feet above 33 feet the current must be derated 1%. Maximum 66 feet (consult factory above 66 feet). Relative humidity lower than 95% without condensation. UL 58C compliant. UL, cul, CE approved. Electrical Characteristics Input Power 3 phase 38 V to 48 V +1%/-15% Frequency 48 to 63 Hz 1 phase 28 V to 24 V +1%/-15%.98 power factor 3 phase 28 V to 24 V +1%/-15% Output Power 3 phase from to Vsupply (All motors must be 3 phase.) to 6 Hz frequency PAGE 17

Variable Speed Controls Aquavar SPD Aquavar SPD Features Easy Set-up Pre-set for submersible or surface motor characteristics. Pre-wired and tested transducer. Touch button pressure setting. No complicated menus or electrical programming to cope with. Total set up time including wiring is less than 3 minutes. NEMA 3R Outdoor rated enclosure eliminates the need for separate cover panels required by competitive standard NEMA 1 enclosures. Operating temperature -22º F to 122º F! Dual Phase Input UL Listed for either three phase or single phase input (de-rated). Filter Pack Aquavar SPD models with an F suffix come complete with output filter rated to 1 feet of motor lead. It is ready to go without having to source and install components from other sources. Programming is also pre-set to 3 Hz minimum to protect motor bearing lubrication required by some motor manufacturers. True Motor Match The Aquavar SPD is already rated for the higher amps typical of higher HP submersible pump start-up. There is no need to oversize the drive as with other units. A 1 HP Aquavar SPD will run a 1 HP submersible pump! Transducer As with all Goulds drives, the pressure transducer is included with the drive so there is no need for separate sourcing and compatibility checks. The transducer is pre-wired and tested, with internal case grounding! Full Diagnostics In addition to typical electrical protection and diagnostics, the Aquavar SPD has a full range of pump protection features such as bound pump or motor shut down, low water or loss of prime shut down. These added features require no added input devices. Remote on/off Permits external control by timers (irrigation), float or pressure switches (tank draining) or manual control. Dry contact closure required. Hand/Auto Option Allows the drive to be run at full speed without a pressure transducer for longer periods of time as in the case of new well development or system start up. Turning the control back to auto resumes the automatic pressure tracking and control. Remote Monitoring External monitors may be connected to the drive for monitoring pump running speed (4-2 ma output based on speed), pump on, and system fault. The fault indicator can also be connected to devices like an auto-dialer. This enables control of pumps and drives in un-manned locations. The 4-2 ma output can be utilized for functions such as an external dosing system, chlorine injection. Pressure Drop The reaction time of the drive to pressure drops can be adjusted from the typical 5 PSI drop to as much as 2 PSI. This allows for fewer starts. Dual Set Point The Aquavar SPD has the capability to be programmed with two pressure set points. An external contact such as a timer can be used to change between them, so that a booster pump serving both a building and an irrigation system can do both jobs without manual resets. No Water Restart The Aquavar SPD has the capability to adjust the time delay in between each dry well fault. Adjustable from 1 minutes to 2 hours between each restart. Ideal for low yielding wells. Simplex Variable Speed Pump Controller Aquavar SPD models with an F suffix are configured for submersible pumps. Models without the F suffix are configured for centrifugal pumps. PAGE 18

Variable Speed Controls Aquavar ABII 1151AB2, 1AB2 and 2AB2 Aquavar ABII Controller Features Variable Speed Constant Pressure Systems Input Power* 1151AB2 115V +/- 15%, 5/6Hz 1AB2, 2AB2 23V +/- 15% 5/6Hz (controller only) Output Power Up to 23V three phase (based on input voltage). Motor rated for 28-23V, ±1%. Maximum Output Current 4.2 amps 1151AB2 and 1AB2; 6.9 amps 2AB2 Input Controls Up and down buttons to set pressure. Signal Lights Power on, pump running, inverter stopped, pump stopped, standby, faults/errors. Electrical Efficiency Over 95% Protection Against Short circuit, under voltage, overload, motor temperature, dead heading, run out, suction loss, sensor fault, bound pump, over voltage, static discharge. Ambient Temperature 34º F to 14º F Maximum Humidity 95% at 14º F, non-condensing Air Pollution Avoid mounting in areas with excessive dust, acids, corrosives and salts. Approvals C U L US Controller Enclosure NEMA 3R, IP 43 (Rain-tight) Mounting Wall mount with mounting hardware. Cooling Convection with heat sink. 1151AB2, 1AB2 and 2AB2 Transducer.5-4.5 VDC with 5 VDC power supply, 1 psi range, 8-inch 3-core cable. Input Wire 5 feet of 14 gauge cable. Cable is pre-wired to controller and junction box. Output Wire 1 feet of 14 gauge cable. Cable is pre-wired to controller and pump motor (when provided). * Low input voltage may affect motor operation. Pressure Range Nominal Range Field adjustable from 2-85 psi, total system pressure. WARNING DO NOT SET REQUIRED SYSTEM PRESSURE ABOVE 85 PSI. SEVERE DAMAGE TO PLUMBING COULD RESULT. HMS Pump Available as a complete booster system with several pump options. See BAQUABII bulletin. Model HMS shown. PAGE 19

Distributor Information Xylem Inc. manufactures professional grade pumps, controls and accessories for commercial and residential sump, effluent and wastewater applications. Our nationwide distribution and U.S.-based manufacturing facilities can get you the products you need quickly. Backed by over 16 years in the pump business and the Goulds Water Technology customer support and service that is second to none. Xylem Inc. is a global leader in the water technologies market. The product portfolio includes submersible and line shaft turbine, 4 submersible, jet, wastewater and centrifugal pumps for residential, agriculture and irrigation, sewage and drainage, building services, commercial and light industrial use. For more information visit www.gouldswatertechnology.com or www.centripro.com. Xylem Inc. 2881 East Bayard Street Ext. Seneca Falls, NY 13148 Phone: (8) 453-6777 Fax: (888) 322-5877 www.gouldswatertechnology.com Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. CentriPro, Aquavar, Aquavar ABII, Aquavar SPD, AquaForce, CentriGuard, GT Irri-Gator and PrimeLine are trademarks of Xylem Inc. or one of its subsidiaries. Modbus Protocol is a registered trademark of Modicon Inc. 212 Xylem Inc. BRGLCAR R1 March 213