ADE5F. Inspectable Armour Cable Gland NEW! 2012 Eaton Corporation. All rights reserved.

Similar documents
ADE 6F ADE 6F. page 46

The safety you rely on.

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

ABG Cable Glands Installation Procedure

Capri ADE 6F - for Armoured Cable

Cable Glands - American Series - NEC/IEC

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

TWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY.

Number Size Gasket A1 Gasket A2 Gasket A3 Gasket A4 Gasket A5 Metric B - C

Installation Guidelines For BW Gland

Valve. Monitoring Systems. Limit Switch Box. VMS range For handwheel operated valves

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

Compact temperature switch Model TCS

Eaton Aeroquip Core Hydraulic Hose Products Brochure. Success made simple. The new standard for hydraulic hose and fittings.

Kopex-Ex cable glands offer superior protection in hazardous environments

Global Cable Gland Solutions

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Global Cable Gland Solutions

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

New products Ex Equipment 2015

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

General characteristics and technical data Series MCS

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Solutions Ex d IIB+H2, Stainless Steel EJBX*

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVDL LED fitting - zones 21, & 22

Compact pressure switch Model PCS

Floodlight Series 6121

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

EXEL-L. Detail of the internal side. Transparent polycarbonate

Assembly. Trunk IN + - S U, I U, I. Spur 1

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Specification and Application

Platinum Warranty Program. Exclusively Designed for Top Quality Fleets

Amphenol Cable Glands and Cord Grips Amphenol

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

7000 Series Buccaneer

E A E xe ENCLOSURES. For Harsh & Hazardous Environments.

6000 Series Buccaneer. Secure, quick connector mating and release. 30 twist locking Tamperproof lock prevents accidental un-mating

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

Limit Switch Type 4747

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

POINT CIRCLE-H LIGHTS PTPS LED TOUCHDOWN & POSITIONING SYSTEM LIGHTED TD/PM CIRCLE & H MARKINGS

LED Linear Luminaire Series EXLUX 6402

Compact differential pressure switch Models DC, DCC

NEW. MAGNASPHERE L2C HSS Technology. Only concealed contact to meet UL 634 Level 2 High Security Standard

Armoured / Un-armoured Cable Gland

Brass Compression Fitting Range

Thermocouple For additional thermowell Model TC10-B

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

APPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Thermocouple Model TC10-H without thermowell

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number

GLOBAL CABLE GLANDS and accessories solutions. Global Cable Glands and Accessories Solutions

IECEx Certificate of Conformity

Tubeskin thermocouple assembly Model TC59-V

Spec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Compression Fittings. Brass Compression Fittings. Stainless Steel Compression Fittings. PL Nickel-Plated Brass Spigot Fittings

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

7000 Series Buccaneer

PRODUCT CATALOG. Cable glands for Global Applications

Tubeskin thermocouple assembly Model TC59-W

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Temposonics ATEX. Magnetostrictive Linear Position Sensors. DATA SHEET High Pressure Housing (HPH) The Measurable Difference

Type Z & Ex pz purge and pressurization system

Modular Flameproof Brakes

Tubeskin thermocouple assembly Model TC59-V

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

LEDEEN HS Series. Compact actuators

AI352 ATEX INLINE CONNECTOR TERMINATION PROCEDURE

Having the widest range of cable glands products to meet every kind of requirement for use in marine, Industrial and Non(Industrial)Areas.

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

The Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.

Control Buttons Series 8082

Terminal Boxes in Stainless Steel SLS**.T

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Techcrane International, LLC

2-channel analog input module; Pt100 / RTD; for resistance sensors

HTSB system System overview

Cable Glands for Hazardous Areas

IECEx Certificate of Conformity

I Ex-e/Ex-i terminal box I

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Hydraulic Oil & Gas Solutions

Linear Valve Electric Actuator

Pneumatic actuator. Inspired By Challenge

Cable Connectors GET CONNECTED

Product manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Transcription:

ADE5F Inspectable Armour Cable Gland NEW! 2012 Eaton Corporation. All rights reserved.

Common ADE Features - Reminder 2

ADE Gland Product Range Continuing to fill product gaps to match competition 3

Positioning - ADE 5F * Positioned Above 4F But Not All Features Of 6F * UL to follow in Q4 4

ADE 5F Specific Features For use with all armoured cable types in IEC, Marine and Offshore 5 Function Gland Outer seal Inner Seal Armour clamp Armour earth Inspection of cable clamping Available in: M16 to M110 3/8 to 4 NPT Nickel plated brass and Stainless Maintains the established ADE range features 5

ADE 5F Specific Features 1. Larger Flats 2. Enhanced Marking 3. Inspection Cage 4. Anti-Rotation Cage 5. External Clamp 6. Universal Armour System 7. Empty Ingress Protection 8. Factory Nickel Plated 3 4 6 7 8 1 2 5 6

ADE 5F - Design Approach Leverage the positives of the ADE4F 1. Add better clamping using a 6F derivative to give inspection 2. Improved anti rotation system 3. Improve assembly and identification 4. Specifically target braided cable 7

Universal Armour System ADE5F Universal Armour Clamping The patented Cage System a unique design allowing the use of a wide range of armour types and thickness without the need to select the correct internal components or orientation. Before clamping the cage spline are not fully engaged Clamping the splines provide a Semipermanent locking of the clamping components onto the armour 8

Design Approach - ADE 5F Improvement 1: Armor clamping 1. Extractable from the cable gland ( hand ) Inspectable ( visual ) 2. Demountable ( with a tool such as a screw driver ) 3. Reusable ( in case inspection is not good ) «Cage system» PATENTED since ADE6F 9

Design Approach - ADE 5F Improvement 1: Armor clamping Put the armor into the Impression ring Put clamping ring in front of the compression ring Tighten the internal cap-nut 10

Inspectable ADE5 Improvement 2: Innovative Anti-Rotation System Patented Cage System Innovative Design Protects Thin Armour And Allows Inspection 11

Design Approach - ADE 5F Improvement 2: Innovative Anti-Rotation System The Compression ring is limited in rotation in the body (slots & ribs). No damage on thin braided cable when cabling 12

Design Approach - ADE 5F Improvement 3: Clear identification of the product Product identification Improvement 4: Increase the size of the 6 flats According to NFE 74 302 Spanner dimensions 13

External Clamp ADE5F Provision For External Additional Clamp Cost Effective Way To Comply To Standard For Cable Support 14

Empty Ingress Seal & Ni Plating Ingress Seal In Place When No Cable The Empty Ingress Seal protects from any ingress into the enclosure before cables installed without the need to plug. The design of the seal incorporates a tear out bead. The use of a screw driver pushed into the bead starts the tear. The entire membrane removes along the bead cleanly ready to accept cable. All Nickel Plated Brass components, both external and internal, are designed specifically to allow for a nickel plated coating between 5 to 7 microns that ensures the critical tolerances can be maintained. 15

ADE Series Kit Options Standardized on three kit options K1, K2 and K3 kits are available for all of the ADE range. K1 kits are also suitable for the NEWCAP range Any other accessory requirements will be handled as loose items 16

Certification - ADE 5F Hazardous location certificates 1. ATEX / INERIS: INERIS12ATEX0032X 2. IECEx / INERIS: IECEx INE12.0025X 3. CEPEL: 05.0559X for 4F, 5F, 6F, 6FC 4. NANIO CCV: TC RUC-FR.ГЬ05.B.00093 5. NEPSI: GYj13.1082X Marine applications 1. DNV: E-12360 2. ABS: 10-HS577243-2-PDA 3. Lloyds: 11/00072(E1) Product Well Covered in Terms Of Approvals Pending. Q4 2014 17

Support Tools ADE5F Selling Tool Sheets Installation Videos New pictorial installation sheets 18

Specification Comparison 1. Larger Wrench Flats 2. Enhanced Marking 3. Inspection Cage 4. Antirotation 5. External Clamping 6. Universal Armour 7. Ingress Protection 8. Nickel Plated ADE5F T3CDS 501/453 19

Pricing ADE5F Positioned to achieve a small premium over the 4F Significantly lower than the 6F at better margin Included in 2014 Global List Price Same discount levels as other ADE range 20

21