Deutz Cummins Kohler IVECO Detroit Diesel MTU Volvo/Penta Perkins John Deere Mitsubishi

Similar documents
White Paper Load Banks for Power System Testing

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Diesel generator set QSX15 series engine

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

130 KW / 165 KVA POWERED by

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

Diesel generator set QSK23 series engine

70 KW / 90 KVA POWERED by

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

23 KW / 29 KVA POWERED by

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

60 KW / 75 KVA POWERED by

45 KW / 55 KVA POWERED by

300 KW / 375 KVA POWERED by

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

57 KW / 71 KVA POWERED by

DIESEL GENERATOR SET MTU 16V2000 DS1100

700 KVA / 550 KW POWERED by

28 KW / 28 KVA POWERED by

600 KW / 750 KVA POWERED by

105 KW / 130 KVA. POWERED by TP-I100-T2-60. kva 130 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 125 Prime Power Factor 0.

power made simple kva RANGE Performance I Durability I Serviceability

20 KW / 25 KVA LIQUID COOLED POWERED by

APD-ULJ250. Standby Power

80 KW / 100 KVA POWERED by

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

640 KW / 800 KVA POWERED by

1800 KW / 2250 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

400 KW / 500 KVA. POWERED by TP-JD400-T3-60-UL. kva 500 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

500 KW / 625 KVA POWERED by

1000 KW / 1250 KVA POWERED by

Diesel generator set QSX15 series engine

Spark-ignited generator set

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TECHNICAL DATA SHEET KVA UPS Systemss

Diesel Generator Set S3.8 Series Engine

Diesel generator set QSK23 series engine

Technical specification

130 KW / 165 KVA POWERED by

PGDLS352KW 380/ / / / / / / / /

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGDLS / / / / / / / / /

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

55 KW / 70 KVA POWERED by

60 Hz FEATURES. Exclusively from your Caterpillar dealer

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

55 KW / 69 KVA POWERED by

18 KW / 18 KVA POWERED by

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

KM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

16 KW / 20 KVA POWERED by

DIESEL GENERATOR SET MTU 16V2000 DS KVA

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

204 KW / 254 KVA POWERED by

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Rental Power QSB7 series engine

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

KM33. Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

CGT Stamford UCI 274 E1

Innovative Circuit Technology Ltd.

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rental Power QSL9 series engine

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

BID SPECIFICATIONS FOR (1) 300kW STANDBY GENERATOR

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

PGDLS / / / / / / / / /

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Illuminator Series CR NEMA 3R

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

VIRTUS Diesel Gensets

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

2000 KW / 2500 KVA POWERED by

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Diesel generator set QSB7 series engine

PGKT / / / / / / / / / / / /

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Diesel generator set QSL9 series engine

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Transcription:

Generator Maintenance Services Deutz Cummins Kohler IVECO Detroit Diesel MTU Volvo/Penta Perkins John Deere Mitsubishi Is your building generator s manufacture in this list? Your generator needs regular servicing to maintain it for those critical times when there is a power interruption. Our factory-trained service technicians will keep your system in peak condition under our maintenance contract so you do not have to worry about it. During our regular maintenance calls, we: Inspect and test the batteries, Check and top-up the lube oil if necessary, Run the engine to assure it is in peak condition. Inspect all of the service parts and maintain a supply of originalequipment and factory-authorized service and replacement parts. You receive a comprehensive maintenance report with our professional maintenance guidelines. Our service plan can include standby and emergency service, diagnostic service, lube oil and filter change, radiator coolant check and change, engine oil testing., resistive load bank testing.. We can provide standby for annual FSB inspections with PE endorsement Please contact us to discuss your requirements and for details of our standard service plans

We specialize in expert service for your facility generator set. Regular Servicing Monthly/Quarterly servicing of your engine using our 56-point checklist and service guidelines assure your equipment is ready should it be needed in an emergency. Annual Servicing Every engine manufacturer recommends a lube oil change every 250 running hours or at least once per year. We dispose of the used oil through NEA approved vendor at no cost to you. We use only manufacturer-approved grade lube oil and genuine service parts for all of our servicing needs which include the lub oil filters, by-pass filters, fuel filters, water filters, etc. Load Bank Testing for Generator All engine manufacturer s recommend regular testing under load to keep your engine performing well. We use our own load banks to test your diesel generator set at its rated load. This removes built-up carbon, prevents buildup of acids in the lube oil, and buildup of detrimental carbon particles in the exhaust valves and help maintenance of the piston ring seals. Your engine will run better, more efficiently, and you are assured you are doing everything necessary to prevent an inconvenient power outage from becoming a disaster.

OUR LOAD BANK available. Load Bank Control Most of our load banks are from the UK to test power supplies from 1 kw to several MW. The Intelligent Hand Held Terminal (IHT) provides full load control and three-phase instrumentation on any equipped load bank. All electrical enclosures are to IP54. An emergency stop/disconnect switch gives full isolation of the fan and control supply. As well as the MS66 and MSI 10 described here, an extensive range of resistive, inductive or capacitive load banks is also All instrumentation measurements are made using high accuracy voltage and current transformers located within the load bank. This information is processed. Digitally, using high-speed sampling of the raw data; this provides full threephase true rms measurements with high update rates. Three instrumentation display 'pages' show all the main electrical parameters. The displays are designed to simplify the setup and adjustment of Generator and UPS supplies. A large display of Voltage and Frequency to assist in initial setup. When full-load testing, one page shows all the true rms three-phase measurements of Voltage (V), Frequency (Hz), Current (A), Power (both kw & kva) & Power Factor (Cos F). For transient-response testing, the voltage and frequency of the last load change are captured and displayed on the dynamic graph including maximum and minimum data. Alternative to the Intelligent Hand-held Terminal (IHT), our load bank do have PC software, It provides further enhanced load control along with Transient speed instrumentation, Full data acquisition reporting with graphical displays. Real time data such as crest factor recovery times and % errors necessary for testing to ISO8528.

Why test your generator to full capacity Engine manufacturers all recommend running your engine at a partial load on a regular basis to prevent carbon fouling (buildup of carbon on cylinder heads, pistons and valves) and wet-stacking (unburned diesel fuel accumulation in the cylinder) which rob power from your generator and reduce the lifespan of the engine. Running the engine at idle and without a load are the cause of these maintenance faults. Singapore Standard CP 31:1996 defines a series of tests and records required for standby generator sets. Our standard maintenance schedule assures that your generator maintenance program meets or exceeds this standard. The NFPA 110:1999 requires all standby generators run at full load at least once a year to assure they come up to speed and settle in at the proper power to support the emergency equipment that they are in place to run. Linear Power Systems engineers and technicians provide the necessary equipment to run the full series of tests under load required under the above codes and in compliance with Singapore and international standards and procedures.

Others Service All of your Generator and critical systems maintenance and repair in one set of hands, one invoice, one payment. We can customize one of our standard service plans to fit your needs and budget. We provide standard and customized service plans to fit your needs and budget. Preventative maintenance. One time inspection and servicing Predictive maintenance Emergency and critical service response available Stand-by system support for your annual shut-down exercises. Full load functional testing with resistive load banks (to 6000KW) with our own equipment. Rental generators from 20KVA to 1250KVA We can provide stand-by system support for your annual FSB inspection and shut-down exercises as well as electrical systems maintenance and service by certified professionals. We are able to provide Professional Engineer endorsement for our testing services. Uninterrupted Power Supply (UPS) Load Bank testing. RENTAL OF LOAD BANK AND POWER CABLES We have a wide range of load bank and power cables for rental. Appendix A. Renewal of Storage tank licensing To assist you in your On-line electronic renewal of Flammable Materials Storage License for the above premise, which would include the following scope of services: To liaise with FSSD, SCDF on the matter of License Application, To advise you the amount of License payable. To submit the Emergency Response Plan as required by FSSD, To provide Visual Inspection and issue Certificates of Fitness with QP endorsement. V1.1b 2 June 2003

MAINTENANCE CHECKLIST FOR STANDBY GENERATOR A. BEFORE STARTING 1. ENGINE SYSTEM: - i) LUBRICATING SYSTEM: - PIPE & CONNECTION FOR LEAKAGE OIL FILTER RECORD OIL LEVEL (TOP-UP IF NECESSARY). ii) COOLING SYSTEM: - PIPES & HOSES FOR LEAKAGE COOLANT LEVEL (TOP-UP IF NECESSARY) AIR RESTRICTIONS FAN BELTS (ADJUST/TIGHTEN IF NECESSARY) PULLY, WATER PUMP ETC. (GREASE IF NECESSARY) iii) AIR SYSTEM: - PIPE & CONNECTION FOR LEAKAGE AIR FILTER (CLEAN IF NECESSARY) iv) FUEL SYSTEM PIPE & CONNECTION FOR LEAKAGE FUEL TANK LEVEL LINKS & FUEL PUMPS (GREASE IF NECESSARY DRAIN SEDIMENT IN DAY TANK. (IF NECESSARY) FOR WATER IN DIESEL TANK (DRIAN IF NECESSARY) STORAGE TANK LEVEL v) EXHAUST SYSTEM PIPE & CONNECTION FOR LEAKAGE EXHAUST MANIFOLD EXHAUST SILENCER TURBOCHARGER EXHAUST COLOUR vi) HEAT EXCHANGER LEAKAGE vii) OTHERS: - VIBRATION ISOLATORS HOLDING DOWN BOLTS COUPLING BOLTS

2. ELECTRICAL SYSTEMS i) CONTROL PANEL: - WIRING CONNECTIONS MOUNTING SCREWS METERS LAMPS ii) ALTERNATOR POWER CABLE CONNECTION CLEANLINESS IN TERMINATION 3. BATTERY CHARGER SYSTEMS i) BATTERY BATTERY CONDITION ELECTROLYTE LEVEL SPECIFIC GRAVITY LUGS AND TERMINALS ii) BATTERY CHARGER CHARGING VOLTAGE CHARGING CURRENT CHARGER ON BOOST, FLOAT OR AUTOMATIC B. ENGINE RUNNING RECORD 1. ENGINE PANEL: - ENIGNE SPEED OIL PRESSURE ENGINE TEMPERATURE. OIL TEMPERATURE. EXHAUST TEMPERATURE 2. GENERATOR CONTROL PANEL GENERATOR OUTPUT VOLTAGE. (ADJUST IF NECESSARY) GENERATOR FREQUENCY. (ADJUST IF NECESSARY) GENERATOR OUTPUT CURRENT. GENERATOR OUTPUT KILOWATT. C. RECOMMENDATION / OTHERS

Appendix A 400V (50Hz) KW Size (mm) Weight 480V Length Width Height (Kg) (60Hz) Discharge Controller 903 1300 3545 2060 2525 1500 Side Loader 903 1300 3545 2060 2525 1500 Side Loader 903 1300 2340 1540 2070 1500 Up Loader 903 1300 2340 1540 2070 1500 Up Loader 600 1830 1240 1520 668 Side Loader 600 1830 1240 1520 664 Side Toggle Sw Aux Supply Main Breaker 600 1240 1300 1560 510 Up MCCB Internal Yes 400 1800 1420 1740 888 Side MCCB Internal Yes 400 1800 1420 1740 886 Side MCCB Internal Yes 300 825 875 1350 280 Side Loader 300 825 875 1350 280 Side Loader 200 1000 810 1580 242 Side Loader 150 1530 1150 1260 328 Side Contactor Internal 100 980 740 1065 150 Up Loader Internal 100 980 740 1065 150 Up Loader Internal 100 980 740 1065 150 Up Loader Internal 100 980 740 1065 150 Up Loader Internal 80 110 70 150 214 Side MCCB 50 1240 1040 1200 254 Side Contactor Internal