User Manual Digital Water Level Indicator for rain water storage tanks

Similar documents
INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

KEWTECH. KT56 digital multi function tester. Instruction manual

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Operating manual UPS - System

Level Measuring Sensor for Diesel Fuel Tanks

Autoranging Industrial Multimeter

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

Service information. How to avoid equipment failures with preventive maintenance measures. 1. General information 08/2017

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

Operating instruction and technical description

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

c-go 24V/6A 24V/8A 24V/12A

SP6. Automatic Battery Charger. Model

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

i n s t r u c t i o n m a n u a l

User Manual WT Combi-S Pure Sinus Wave Inverter

Operating manual. ba55321de LRD Conductivity measuring cell to be installed in pipelines. ba55321de01 12/00

TRAIL-Control - Manufacturer -

Installation manual portable distributors

zelsius Installation and operating manual All that counts EnergyMetering

Installation manual wall-mounted distributor

Fuse state indicator MEg72. User manual

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

7007 Loop Mate 2 Loop / Voltage / Current Simulator

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

User s Manual. Automatic Switch-Mode Battery Charger

Operating Instructions K Always on the safe side.

Installation Manual CS9100-LED. Professional Series Landscape Lighting System

HIGH TECH SECURES YOUR FUTURE SBA 1200 GB SUN BRAKE ANALYSER. Operating Manual

Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Models: SP3, SPSS3 Automatic Battery Charger

1.Safe testing IMPORTANT:

MBM8 / MBM11- Barriers. Installer and User s manual

FREQUENCY INVERTER INSTALLATION & USER GUIDE

WATERFLUX 3070 Quick Start

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

G72x Series Direct Spark Ignition Controls

pond and garden 3 x 1 watt / 5 x 1 watt

STONESTAR AUSTRALIA PTY LTD

ASSEMBLY INSTRUCTIONS

Installation and Operating Instructions

True RMS Autoranging Multimeter

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions

Table of Contents General Information Safety Message Classifi cation...2 Safety Notes...3 Terminology...4 Coupler Lifting Lug...

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

G76x Direct Spark Ignition Controls

C3 Operating Instructions

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Operating instructions 1 4 Mode d emploi 5 8 Instrucciones de uso 9 13 Manual de instruções 15 18

Measurements are expressed in millimeters.

TC1000 Service Manual SALES: CUSTOMER SERVICE:

CHUBBSAFES EVOLVE INSTRUCTION MANUAL

CTEK XC 800 Battery charger

Installation and maintenance instructions for the GRAF Universal External and internal Filter 3

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents.

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Operating instructions

KSZ 10B Current Probe Calibrator. Instruction Manual

INSTRUCTION & INSTALLATION

Operating instructions Flow monitor SI / / 2013

Throttle Body Instruction Sheet

NOVELTY. Platin flat rainwater tank. GRAF s version of the flat tank. Integrated filter. Attractive tank. installation depth Suitable for.

Assembly and Operating Instructions

Functions and Displays

Installing Power Components

zelsius Installation and operating manual All that counts. EnergyMetering

.3 Section Waste Management and Disposal.

GL1200T Cut & Seal. (GL1200 Seal only)

SAFE & SECURE ACTUATOR PRODUCT MANUAL

INSTALLATION INSTRUCTIONS AM rev. A

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

SAVER DSP SERIES. 3-10kVA USER MANUAL

BATTERY CHARGER Instruction Manual

KA - DODGE NITRO - 4.0L V6 SOHC

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Autoranging Multimeter

Marin Control Digital

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

Chapter 9 Basic meters

Operating manual POWER TINY USA. a Look Solutions 1 product

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Operation Manual for Torque Sensors

TN299. Universal Hybrid Battery Charger IMPORTANT SAFETY WARNING. READ MANUAL in its entirely before use. INSTRUCTION MANUAL

CONTENT 1 PICTURE GENERAL... 3

! CAUTION! Damages on the machine possible.

StarEye. 350 ma version. No control electronics on board

MANUAL. Single charger

4000 SYSTEM OPERATING MANUAL

Installation and Operating Instructions

Transcription:

User Manual Digital Water Level Indicator for rain water storage tanks We congratulate you on the purchase of Digital Water Level measuring device. You have purchased a high-quality product built to the highest standards of modern technology. Before you start to assemble or operate the equipment, please read the user manual with care and verify the parts supply for completeness. List of parts supplied: 1. The Digital Water Level Indicator. 2. The stainless steel measurement probe (red and white connection cables approx. 10 feet long). 3. The Measurement Sensor Box. 4. Installation material, a spare fuse and spacers. Important notes on safety: Please, read and follow safety instructions carefully before assembly or using the device! Equipment using a 120V AC supply may only be installed and commissioned by a qualified tradesman. The assembly place must allow all possible safety precautions when laying the attached cables. Power supply cables and data cables may not be damaged or squeezed for any reasons. Plan the assembly place so that you can reach the transformer easily and unplug it from the electrical outlet in dangerous situations. Choose the assembly place so that children cannot play or be near the device or its connections without supervision. Before opening the device disconnect it from the main supply (unplug) otherwise there is a serious danger of an electrical shock. Fuses may only be replaced with standard-compliant parts with the same nominal value. All liability is excluded for damages which result from non-compliance of these instructions or from improper handling of the device. At chosen intervals in this hand book we will give directions for safety precautions. These safety precautions have been specially marked. Otto Graf GmbH Carl- Zeiss Str. 2-6 Tel.: 07641 5890 Kunststofferzeugnisse D 79 331 Teningen Fax: 07641 58950 1

1. Description of the equipment The Digital Level Indicator has been developed especially for rain water usage. Synthetic material tanks are used. Cement and metal tanks are only conditionally usable. With the calibration function the system is coordinated to the different tank heights. The fill level in the tank is shown in 1% steps by a 3-digit LCD-display. The sensor electronics work with 12 volts of low current and is reverse polarity protected; it is attached to the main device with a 65 foot data cable. As soon as the calibration and the assembly are completed no further setting up is necessary. The reference value for a 100% fill level remains stored in the case of a power failure. Performance features: - Fill level indication in 1% steps - Status LED which shows the operation in progress - Self calibrating routine - Permanent supervision of sensor electronics - Error code message display The following picture shows your newly acquired device: 1: Fastening holes 2: LCD- Display 3: Button for setting the max. filling level 4: LED- On Figure 1: Overall equipment list 2

Technical data: Digital Water Level Indicator Sensor electronics Operating voltage : 24V/60Hz Measuring current : 12 volts = Power consumption : 3 watts Measuring frequency : 200 Hz-20 khz Output voltage : 12 volts Data cable length : 165 feet maximum Tank depth : 10 feet Measurements (LxWxD): 4.75 x3.1 x2.3 with protection : IP54 Measurements (LxWxD): 3.6 x3.2 x2 with protection : IP54 Fuse in the device : T 50mA 2. Assembly 2.1 Digital Water Level Indicator housing installation Power must be disconnected during installation and service. For the connection to the 120V line please use a plug-in transformer. Should it necessary to open the housing, take care that the device has been disconnected from the main power supply (unplugged). Mark out the hole positions on the wall and drill accordingly. After having fixed the housing using the supplied screws and plugs, attach the data cables and the 24V AC output of the plug-in transformer to the terminal block. The device fuses are found inside the cover. Before changing the fuse it is important to disconnect the device from the main power supply (pull out the plug)! Loosen the four screws holding the cover and lift carefully open. Replace the faulty fuse with the same rated (T50mA) and recluse the cover. Refasten the cover with the four screws. Figure 2: Position of the fuse 3

2.2 Sensors and data cable connection: The sensor electronics comprise of a stainless steel probe [22] with a red and a white connecting cable [27] and the sensor control box [28]. Figure 3: Sensor technology 1. Now the sensor control box [28] (cover removed) should be installed on the tank wall (preferably in the man hole shaft of the Graf synthetic tank). The location of the mounted sensor control box should be at least 6 inches above the overflow [25]. The enclosed screws should be used to secure the device. After fully tightening the screws, the points that are showing themselves on the outside of the tank must be blunted to avoid injury [24]. 2. Measure the height from the bottom of the tank [23] to the end of the terminals [15] and [16] on the sensor control box [28]. 3. Shorten the connection cable to suit the measured height. 4. After shortening the cable, the distance between the cable fastening spacers [21] should be set equally along the entire length. The cable fastening spacers prevent the red and white cables of the sensor from crossing over and thereby causing a slight distortion of the measurement readings. If for any reason the cable fastening spacers cannot be mounted, an additional distortion of the measurement reading of approximately 1% may result. 5. Connect the sensor cable to the sensor as described in the following instructions: Remove approximately 1/4 of the insulation from both of the wires. Next, pass the red wire through the screw mounting 1 [19] and tighten this lightly, then connect the red wire to the terminal [16]. The free white wire is now passed through the screw mounting 2 [18] and tightened lightly, then connect the white wire to the terminal [15]. 6. Now pass the end of the data cable [12] through the screw mounting 3 [13]. Lightly tighten the screw mounting and connect the cable wire cores of the data cable [12] to the double terminal [14]. The connection of the data cable is reverse polarity protected. Attention! The screws should be tightened with care to ensure that they are not damaged through over tightening. 7. Now recheck that all the screwed items and the sensor components have been fitted 4

correctly. Replace the cover of the sensor control box and secure this with the appropriate fastening screws. Note: The red and the white wires going down to the probe should be straight and smooth to be drawn taught by the weight of the stainless steel probe. The stainless steel probe must hang just above the tank floor. When setting the spacers please be sure to distribute them equally over the complete length as shown in Figure 4. The following illustration clarifies the context: 5

12: Data cable 13: screw cap 3 14: Connection of the data cable is reverse protected. 15: connect white wire here 16: connect red wire here 17: data cable terminal 18: screw cap 2 19: screw cap 1 20: active measuring length 21: When assembling be sure, that the cable spacers are equally distributed over the cable length. 22: Stainless steel probe 23: Tank floor 24: Screws must be blunted! (danger of injury) 25: overflow 26: Tank side in dome 27: Sensor 28: Sensor control box Figure 4: Sensor assembly 3. Activation and calibration process Before energizing the equipment, check and be sure that all electrical connections are correctly insulated and all covers are properly closed! Now plug the plug-in transformer into the mains socket particular to the equipment. The green LED "Power" must light up. The LCD display will run through range of number combinations shown. These are used in the initialization of the equipment. The initialization is completed as soon as the value stops and stays still, i.e. the display shows no further fluctuation. The device now runs with the factory standard settings (measuring cable length of 6.5 feet). Should you have a different measuring cable length then the device must be calibrated. To do this proceed as follows: 6

Calibration procedure: 1. Fill the tank up to the maximum height. If this is not possible then you should proceed with the alternative as follows: - Fill a bucket with water. - Put in the stainless steel probe with the red and white wires attached in the required measuring lengths completely submersed in the water then continue as from point 2. 2. Press the calibration button. The code "901" is shown in the LCD display. 3. Release the calibration button and wait until the code "902" is shown in the LCD display. 4. Now press the calibration button again, quickly, to save the determined value. The code "903" is shown briefly in the LCD display. 5. After this wait for a few moments until the display shows 100%. Remark: After the code "902" appears the calibration button must be immediately pressed, if this is not done then the value will not be saved. If this happens then wait a moment and repeat the process. After the completion of the calibration, the fill level indicator is shown in %, in this case 100% shows. (Slight variations may be caused by disturbance of the waters surface). Note: It is possible to re-set the fill level indicator to the factory settings at any time. To do this, pull the plug-in transformer from the mains and wait for a few seconds. After this press the calibration button and hold it pressed and re-plug the plug-in transformer into the power outlet. Hold the button pressed until the LCD code "601" is shown in the display. 4. Error messages and fault elimination Directly following switching on and during the operation mode the digital fill level indicator checks the complete system equipment. If an error is diagnosed it will be shown on the LCD display. 7

The following messages are possible: 602 The calibration process has not been carried out correctly. This error code 602 occurs when the calibration button has been held too long. In this case repeat the calibration process. 701 Sensor error (the sensor control box sends no signal) Start with a check of all the connections of the data cable in the display device and on the sensor control box. Control also for faulty cables (check for current) Check also the terminals of the sensor control box electrodes. If all the cables have been correctly attached and there are no short circuits then the digital fill level indicator must function properly. When the "701" code is still in the display then remove the sensor completely from the tank (the sensor control box remains attached) Attention: make sure the cover of the digital display device is in place and secured with 4 screws. Now reconnect the mains current! The device must now show a value of 0 %. If this is not the case then the sensor is not functioning properly. Should the green LED not light up then the device show no function. Check once again all the connections and of course the fuse. Don t forget to also check the mains fuse. Should all attempts be without success please get in touch with a professional. Purchase date :... Device number :... Tank height :... Design and specifications are subject to change without notice Dated: August 2011 8