EVO AT SERIES BATTERY CHARGER

Similar documents
AT SERIES EVO BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER

AT30 Series (3-Phase) Microprocessor Controlled SCR Battery Charger

Microprocessor Controlled Float Battery Charger

Microprocessor Controlled Float Battery Charger

AT10.1 SERIES FLOAT BATTERY CHARGERS. Advanced technology microprocessor control

Automatic DC Power Supply/Battery Charger

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

SUBSTATION EQUIPMENT - Page 1 of 8

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Industrial Chargers and

Sola/Hevi-Duty S3K Series Mini-Tower UPS

User Manual. Solar Charge Controller 3KW

Liebert PowerSure PSI UPS

SECTION DC POWER SUPPLY/BATTERY CHARGER

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

TECHNICAL DATA SHEET KVA UPS Systemss

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

La Marche Product Catalog Table of Contents

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

3 Uninterruptible Power Systems

User Manual Solar Charge Controller 3KW

ROBICON W120 enclosed drive

3 Uninterruptible Power Systems

Illuminator Series CR NEMA 3R

A36D CONTROLLED FERRORESONANT RECTIFIER / POWER SUPPLY BATTERY CHARGER / POWER SUPPLY. Standard Features

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

DIESEL Engine Fire Pump Controllers Features

Technical Data Sheets

Sola 3000 Guide Specifications

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99


Technical Data Sheets

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

EATON 9315 UPS 200 TO 300 KVA Specifications

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Diesel generator set QSK23 series engine

QUANTUM LX CONTROL PANEL

Spark-ignited generator set

Technical Data Sheets

Diesel generator set QSB7 series engine

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Aurora Single Phase Emergency Lighting Inverters

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

TLE Series UPS 750/1000 kw With eboost Technology

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

AIR COOLED RECTIFIER SPECIFICATION S-50-A

RVS-DN Digital Reduced Voltage Motor Starter

A6Z OPERATING MANUAL

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Technical Data Sheets

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Diesel generator set QSK95 series engine

TRANSFORMADORES DE POTENCIA TRANSFORMANDO EL MUNDO ELECTRICO. Servicios CASA MATRIZ UBICADA EN: ALIADOS ESTRATÉGICOS:

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Technical Data Sheets

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

INVERTER/CHARGERS Off-Grid Power Solutions

Technical Data Sheets

Magellan Utility Scale Energy Storage

Diesel generator set QSX15 series engine

EMEX. Central Battery Systems Emergency Lighting

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Product Specifications

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

AME. Rectifier - Battery charger. Industrial applications: Key features:

A3Z OPERATING MANUAL

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Diesel generator set QSK60 series engine

RVS-DX Digital Reduced Voltage Motor Starter

TLE Series UPS 400/500 kw With eboost Technology

SecureUPS On-Line 120V AC Output, 1300VA

ASCO SERIES 185 Power Transfer Switches

Transcription:

EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000

Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation and made to exceed your expectations. Evo AT Series battery charger was conceived, designed and manufactured with three uncompromising goals in mind: A battery charger that makes your job easier 3GOALS DRIVING THE DESIGN To retain the quality and integrity of the original AT series battery charger design To satisfy your NERC and utility industry requirements in an ever-changing world Driven by these goals and keeping in mind the simplicity and intuitive nature of the original AT series has resulted in an intelligent design that is still the world s easiest to use. The Evo AT Series battery charger's open architecture design offers you flexible operation to meet your ever evolving DC power requirements. These new features are paired with the Hindle Health System to make your job quicker and easier than ever before. 2

Why purchase EVO? Standard Feature Single Phase Three Phase Indicator LEDs For Common Alarms Soft Start Feature Universal Main Control Board 5 Year Product Warranty High DC Voltage Shutdown AT10.1/ AT30 coming soon Data/Event Logging - - Hindle Health Monitor - Hindle Health Button - Hindle Health Diagnostics - Interactive LCD Display - DC circuit breaker status via LCD display AC Ripple Alarm - Field Upgradable Firmware - User Configured Alarm Relays - Adjustable Time-Delay On Alarm Contacts Generic Binary Inputs - Generic Analog Inputs - - - 3

The Hindle Health System offers you peace of mind via real-time status notification that your charger is healthy and operating properly. Continuous self-diagnostics ensure trouble-free operation. In the event an issue is detected, the Hindle Health System alerts you of the problem. The Hindle Health Button initiates a systematic diagnosis of all parameters and internal components to confirm your charger is operating properly. PEACE OF MIND... Hindle Health Status Lights: An indicator light to let you know your charger is functioning correctly. See green? You know all is well. Hindle Health Button: A simple, step by step system check that easily allows the user to verify the internal components are working and operating per the user s set points.... IN REAL TIME Hindle Health Diagnostics: A powerful diagnostic program alerting you of potential issues as they occur. 4

EVO AT SERIES FEATURES & OPTIONS EVO AT SERIES STANDARD FEATURES: Universal main control board operates in any AT Series evo charger Standard Alarm Suite with LED Indicators (AC Failure, Low DC Voltage, High DC Voltage, DC Output Failure, Positive Ground Fault, Negative Ground Fault) Common Alarm LED Indicator (for all alarms including: Low AC Voltage, High AC Voltage, End of Discharge, Low DC Current) Programmable summary relay contact that can be configured to indicate any or all alarm conditions Redundant analog circuit for High DC voltage detection independent of microprocessor control Microprocessor and analog High DC voltage detection methods can be enabled to shutdown charger Float and multiple equalize charging modes with LCD display indication Manual equalize timer (0-999 hr.) AC line automatic failure equalize timer (0-255 hr.) AC On indicator 0.5% Digital metering for Vdc and Adc measurements Graphical LCD Display with LED backlight AC input and DC output circuit breakers Password protection for security A redundant analog circuit for Low Level Detect alarm, independent of the microprocessor Multiple processor design for exceptional reliability Local or remote voltage sense with redundancy in the event of remote sense failure Input & output MOV surge suppressors Battery Open Alarm Reverse polarity protection diode Switchboard wire, UL VW-1 Enclosure pre-treated using a 5-stage iron phosphate process with baked epoxy powder coating in ANSI 61 gray Plug-in socket for removable memory card used for event logging and firmware upgrades Battery backed up real time clock for date and time stamping events Hindle Health System, intelligent self diagnostics Standard output filter per NEMA PE5 EVO AT SERIES SUMMARY OF OPTIONS: Battery Eliminator DC output filtering: per NEMA PE5 Medium & High AIC Breakers Auxiliary alarm relay board Copper ground bus AC lightning arrestor Fungus proofing (tropicalization) Static proofing Serial communications modules (RS-232/RS-485) Ethernet communications module Modbus and DNP3.0 Communication protocols Battery temperature compensation Fan control contactor Custom paint NEMA 4/12 type enclosure w/fan Rack mounting Floor mounting stand NEMA Type 2 drip shield Barrier type alarm terminal block Forced load share Zero-center ground detection meter AC voltmeter AC ammeter Cabinet heater assembly ABS certification upon request Custom drawing package w/ optional CAD and PDF files Remote shutdown Remote battery shunt Generic binary inputs Generic analog inputs Battery discharge alarm 5

EVO AT SERIES SPECIFICATIONS AC INPUT Safety & Acceptance Input Voltage: 120, 208, 240, 480 120/208/240, 550/600 (multi-tap) @ 60Hz 220, 380/416 @ 50-60Hz Input Voltage Tolerance: +10%, -12% Input Frequency Tolerance: ±5% Efficiency: 85-90% typical for 130Vdc at 50-100% load Meets NEMA PE5 Third party agency approvals: Seismic qualified IEEE 693/IBC CBC ABS or CE certification available upon request. DC OUTPUT Voltage Ratings: 24, 48, 130 or 260 * Vdc nominal Current Ratings: 6, 12, 16, 20, 25Adc *260Vdc - 6,12 Adc only Continuous Rating: 110% rated current at maximum equalize voltage at -10 to +50ºC Transient Rating: Per NEMA PE-5 Current Limit Adjustment Range: 50% to 110% rated output Voltage Regulation: ±0.25% for line, load and temp. variations *Regulation at max. extended equalize voltages may not meet ±0.25% Electrical Noise: 32dBrnc Ripple: 24/48Vdc Filtered on battery 30mVrms Filtered off battery 1% Vrms Battery Eliminator 30mVrms 130Vdc Filtered on battery 100mVrms Filtered off battery 2% Vrms Battery Eliminator 100mVrms Super Eliminator 30mVrms 260Vdc Filtered on battery 200mVrms Filtered off battery 2% Vrms Battery Eliminator 200mVrms Surge Withstand Capability: Designed to meet IEEE-472, ANSI C37.90a Environmental Operating Ambient Temperature 5 F to 122 F (-10 C to 50 C) w/o derating Operating Altitude 3300 feet (1000 meters) above sea level without derating Relative Humidity 0% to 95% (without condensation) Audible Noise Less than 65 dba at any point 5ft (1.5m) from any vertical surface of enclosure MADE IN EASTON PROUDLY ENGINEERED & BUILT BY HINDLEPOWER EASTON, PA, USA MADE IN THE U.S.A. 6

EVO AT SERIES SPECIFICATION CHART HOW TO SIZE YOUR BATTERY CHARGER (SIMPLIFIED FORMULA) 22.39 [569] 18.25 [463] 19.00 [483] 5.00 [127] ( Ah x 1.R ) t +L = Continuous Charger Output Rating Ah=Ampere hours removed R= Recharge factor (1 = Pb) or (3 = NiCd) L= Additional standing load t= Recharge time in hours 10.00 [254] 12.98 [330] Float DC Output Rating Volts Amps 120 Battery Charger AC Circuit Breaker Ampere Rating (standard AIC breakers) 208 220 240 380 416 480 600 DC Circuit Breaker Rating Approx. Shipping Weight lbs.(kg) Heat Loss Watts (BTU/hr) 6 16 15 15 15 15 15 15 15 10 99 (45) 40 (136) 22.0-29.5Vdc 12 16 15 15 15 15 15 15 15 20 109 (50) 75 (255) Equalize 16 16 15 15 15 15 15 15 15 25 115 (53) 98 (334) 24Vdc 23.4-31Vdc 20 20 15 15 15 15 15 15 15 30 119 (54) 121 (413) Ext. Equalize 25 20 15 15 15 15 15 15 15 40 136 (62) 150 (512) to 32Vdc Float 6 16 15 15 15 15 15 15 15 10 105 (48) 60 (203) 44 58Vdc 12 20 15 15 15 15 15 15 15 20 120 (55) 107 (365) Equalize 16 25 16 16 16 16 16 15 15 25 155 (71) 139 (473) 48Vdc 46.8 59Vdc 20 40 20 20 20 16 16 15 15 30 170 (78) 170 (581) Ext. Equalize 25 40 20 20 20 16 16 15 15 40 180 (82) 210 (717) to 61Vdc Float 6 25 15 15 15 15 15 15 15 10 130 (59) 99 (337) 110 140Vdc 12 50 25 25 25 15 15 15 15 20 155 (71) 167 (571) Equalize 16 50 25 25 25 16 16 15 15 25 215 (98) 213 (727) 130Vdc 117 143Vdc 20 63 32 32 32 20 20 20 15 30 225 (103) 259 (883) Ext. Equalize 25 63 40 40 40 25 25 20 15 40 265 (120) 316 (1078) to 149Vdc Float KNOCKOUTS ON BOTH SIDES 1.375 [34] 6 50 25 25 25 20 20 15 15 10 155 (71) 167 (571) 248.4 282Vdc 12 63 32 32 32 20 20 20 15 20 265 (120) 316 (1078) Equalize 260Vdc 264-287.6Vdc All specifications subject to change. *Regulation at max. equalize voltages may not meet ±0.25% 7

... JUST PART OF THE NEW FACE OF HINDLEPOWER DC DISTRIBUTION PANEL TRAILER CONNECTION PANEL WE ARE NOW... YOUR DC ENGINEERING POWERHOUSE! MORE THAN JUST GREAT BATTERY CHARGERS, WE NOW OFFER FULLY INTEGRATED DESIGNS THAT WORK TOGETHER TO MAKE YOUR JOB EASIER. FOR MORE INFORMATION: Call HindlePower at 610-330-9000 to speak with our professional and knowledgeable team. Our staff is available Monday-Friday from 8:30am-4:30 pm ET for phone assistance or online chat. Seismic Qualified ABS CE certification available upon request All specifications subject to change. hindlepowerinc.com 610-330-9000