Description. functions including single duct pressure dependent or pressure independent systems.

Similar documents
INSTALLATION INSTRUCTION

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

INSTALLATION INSTRUCTION

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

Form: Rev. A (0802) Supersedes: Nothing. Zoning Tec. echnical Guide

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

Laboratory Room Controller

OE326-23I-OR VAV/Zone Controller

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51)

BAPI-Stat 3 Room Sensor

RVS-DN Digital Reduced Voltage Motor Starter

MATRIX LLC LEVEL CONTROL PANEL

Metasys Zoning Package

Power Switching Devices

LF Series Spring Return Direct Coupled Actuator

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

SMT-AZC INSTALLATION / OPERATION MANUAL

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Metasys Zoning Package Installation

SE8300 Series Installation Guide 24 Vac Low Voltage

MicroTech II Applied Rooftop Unit Controller

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

MicroTech II Applied Rooftop Unit Controller

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Installation, Service, and Troubleshooting Instructions

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

SetPoint 150 Controller Installation Manual

FOR USE IN SOLUTION AIR HANDLING UNITS


PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

SINAMICS GM150 IGCT version

Features and Benefits. Control Features

SLIMZONE CLASSIC /

RC-DO. Room controllers with display and manual forced ventilation function

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

LF Series At A Glance

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

Metasys Zoning Package Overview

Digital Room Thermostats with Touch Screen LCD

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

ECCII to ECCIII Upgrade Kit

RVS-DX Digital Reduced Voltage Motor Starter

ULTRA-ZONE FORCED AIR ZONE CONTROLS EWC

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

MicroTech Applied Rooftop Unit Controller

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

QUANTUM LX CONTROL PANEL

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

Digital High Volume Ambient Air Monitoring Systems 110 Volt

Designed for ease of integration with automation systems

BROCHURE. ABB drives for HVAC applications ACH550, 1 to 550 Hp

Minimum 27 in-lb Torque

SetPoint 501 and 501s Controllers Installation and Operation Manual

Modbus Integration Integration for Modbus Functionality for VT8600 Series

Acid Resistant AVC6000

Application Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No.

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

YCCS Zone/Bypass Damper Assembly

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

BAS Construction Checklist

USERS MANUAL MCD REMOTE OPERATOR

Product information. ORION-PB Poultry computer for floor keeping

Predator Model Number Nomenclature

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Versatile and Powerful

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

AuCom - Soft Starters

HVAC Products. Introducing the SED2 Variable Frequency Drives

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

ECON-ZIP-DETF; ZIP PACK

PIM Pressure Independence Module

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

BACnet MS/TP Networking Flow Balancing Control Valves

YCCS Zone/Bypass Damper Assembly

How to Select the RE Industrial Actuator Part Number

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Precision-I Laboratory System Universal Digital Monitor

TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES

HERZ Electronic room thermostat analog and digital

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

TrueDRY DR65/DR90/DR120

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL

Transcription:

Description The Meridian Basic control system converts a single zone HVAC unit into a variable air volume/variable air temperature multiple zone system. The microprocessor based Zone Manager calculates the heating and cooling requirements for each zone based on real time information received from each Zone Controller. The Zone Manager then directs the HVAC unit to provide the appropriate amount of heating, cooling, and ventilation to satisfy each zone's requirements. A static pressure sensor, which modulates a bypass damper, maintains a constant system duct pressure. Substantial savings can be realized using the Meridian Basic system instead of installing multiple HVAC units to accommodate multiple zones. The Meridian Basic system is versatile and can be used with any 3-40 ton HVAC unit. It controls a variety of terminal unit functions including single duct pressure dependent or pressure independent systems. User friendly, menu driven, fill in the blank programming, makes the Meridian Basic easy to set up and operate without the need for specialized training. ZoneView AZ, a Windows based color graphic software package is available at no additional charge. The optional CommLink II must be ordered and connected to a PC in order to use the software for on-site control and monitoring. If remote monitoring and control is required, an optional modem must be ordered or supplied. 036-33060-001 Rev. A (0301)

Table of Contents TYPICAL APPLICATION...3 TYPICAL SYSTEM...4 SYSTEM OVERVIEW...5 TECHNICAL DATA...6 ORDERING INFORMATION...7 NOTES...8 What Is Meridian? Meridian is a new approach to providing simple, cost effective, control solutions to many standard unitary HVAC systems. Meridian provides a very competitive controls solution for buildings that require more control than a programmable room thermostat will provide yet are not budgeted for full building automation systems. These systems come pre-engineered, pre-programmed, and fully documented. This provides two main benefits for the contractor, engineer, and end user: 1. Advanced direct digital control technology for comfort and energy savings at up to 50% lower cost than traditional direct digital control systems. 2. A system that is simple to use allowing almost any HVAC technician to install and start-up the system without the need for specialized training. The following pages are designed to give you a perspective of what Meridian can do for your HVAC control applications. Please contact us for more information or a list of distributors in your area. 2 York Heating and Air Conditioning Controls ~ Meridian Basic

Typical Application Meridian Basic Application York Heating and Air Conditioning Controls ~ Meridian Basic 3

Typical Installation Meridian Basic System 4 York Heating and Air Conditioning Controls ~ Meridian Basic

System Overview System Features Multizone comfort from a single zone AHU Controls up to 16 individual zones User friendly, menu driven programming Backlighted LCD display provides complete system status LED s on Zone Manager show status for fan, cooling, heating, bypass, communications and alarms. Seven day scheduling program 365 day holiday program Programmable local or global zone overrides Pressure dependent or independent zone operation Password protection prevents unauthorized access Use of gas or electric heat Selectable, continuous or cycling fan operation Change filter alarm Energy saving economizer control available Trend Logging to PC (requires optional communications interface and software) Windows based color graphic software for on-site or remote monitoring when using optional communications interface User Parameters Seven day scheduling Holiday scheduling Static pressure setpoint Mechanical heating & cooling lockouts Minimum heating/cooling run time Minimum heating/cooling off time Heating/cooling change over delay Supply air setpoint for economizer control Economizer enable setpoint Minimum economizer damper position Occupied/unoccupied - heating/cooling setpoints MIN/MAX zone damper position (pressure dependent only) MIN/MAX zone CFM (pressure independent only) Zone sensor setpoint adjustment offset limit Zone sensor setpoint adjustment Range Function The Zone Manager monitors each zone and in turn controls the HVAC unit to satisfy the requirements for each individual zone while maintaining efficient operation and comfort. Data entry is accomplished through a keypad and backlighted 4 line by 20 character Liquid Crystal Display. User friendly, menu driven programming makes the Meridian system easy to set up and operate without the need for specialized training. The Zone Controller monitors the space temperature and allocates the proper airflow into its assigned space to achieve the desired comfort and ventilation levels. If the supply air temperature is near the zone temperature setpoint, the zone damper modulates to reduce or increase airflow as needed. If supply air will not benefit the local zone, the controller will direct the damper actuator to a minimum position and wait for a change in supply air temperature. For pressure independent applications, an optional airflow sensor can be added. The airflow sensor is easily installed by plugging into a jack located on the controller board. The controller automatically recognizes the presence of the sensor on system power up and configures for pressure independent operation. Drybulb economizer control is available via an analog 0-10 VDC output from the Zone Manager. An optional Wetbulb Module (OE782) is available to provide wetbulb calculations for maximum economizer efficiency. An optional auxiliary relay board is available for control of auxiliary heat, series fan and parallel fan control. The relay board connects to the zone controller via a plug-in modular connector. The Zone Sensor is a patented design, flush wall mounted sensor. A special plate on the face of the sensor accurately samples space conditions, yet rejects the influence of internal wall temperatures. The sensor comes in four models: Sensor only Sensor w/ push button override Sensor w setpoint adjustment Sensor w/ override and setpoint adjustment Each Zone Sensor setpoint adjustment is programmable from 0 to ±5 via the Zone Manager. York Heating and Air Conditioning Controls ~ Meridian Basic 5

Technical Data ZONE MANAGER Power... 24 VAC 25 VA Maximum Dimensions...7.75"W x 9 H x 2.5"D Operating Temp.... 10ºF - 149º F Operating Humidity...Max 90% RH non-condensing Display...Backlighted 4Lineby20Character Keypad....16 Keys I/O Configuration: Inputs-Thermistor (Type III) Outside Air Sensor... -30º F - 180º F Supply Air Sensor... -30º F - 180º F Return Air Sensor... -30º F - 180º F Inputs-Analog Pressure Sensor... 0 to 5 WC Bypass Actuator Feedback Range...500 to 7300 Ω Inputs-Digital Economizer Disable...Dry Contact Change Filter Alarm...Dry Contact Forced Occupied Mode...Dry Contact Outputs-Digital (2 amp @ 24 VAC)* Fan... N.O. Relay Cooling Stage #1... N.O. Relay Cooling Stage #2... N.O. Relay Heating Stage #1... N.O. Relay Heating Stage #2... N.O. Relay Bypass Actuator... Tri-state Exhaust Fan... N.O. Relay Output-Analog (1kΩ min. load) Economizer Actuator...0-10 VDC Communication... RS-485 9600 Baud Weight... Approx. 4 lb. ZONE CONTROLLER Power... 24 VAC 10 VA Max. Including Actuator Dimensions...7"W x 4 H x 1.5" D Operating Temp... 10º F to 149º F Operating Humidity... Max 90% RH non-condensing I/O Configuration: Inputs Room Sensor... 40º F to 120º F Air Flow Sensor*...Range 0-5000 CFM * For Pressure Independent operation only Outputs Damper Actuator...Tri-State Relay Modular Jack Connection Expansion Port...Relay Board -Optional- Modular Jack Connection ACTUATOR Power...24VAC 50/60HZ or 24VDC 3.0 VA Maximum Dimensions...4.53H x 2.56"W x 2.32"D Operating Temp... -22º F - 122º F Mounting...Direct Coupled Rotation... 0º to 95º Adjustable Wiring...RJ11 - Modular Jack Running Torque...35 in-lb. Run Time... 80 to 110 Sec 0to35in-lb Feedback Resistance... 0 to 10KΩ/95º Weight...1.2 lb. BYPASS PRESSURE SENSOR Power...5 VDC Powered from Zone Manager Range...0 to 5 WC Accuracy.... ±0.5% Operating Temp... 57ºF to 284ºF Dimensions...Approx. 2.25 x 3 Weight...2.5 oz. SENSORS Sensor Element... Type III Thermistor 10kΩ @ 77º F Accuracy.... ±0.4º F between 30º F to 150º F Dimensions Room Sensor... Std. Single Gang Flush Mount - White Plastic Tamper Resistant 2.75 W x 4.5 H x 1.25 D Sensor Options... Override Button Setpoint Adjust Slide Duct Sensor... 6 Length Outside Air Sensor...Weather Protective Box 2.75 W x 4.5 H x 1.25 D COMM LINK II (Optional) Power... 24 VAC 14 VA Maximum Dimensions...1-5/8 H x 5.25"W x 7"D Operating Temp... 10º F - 140º F Communications: Computer...RS-232/9600 Baud Network...RS-485/19,200 Baud Protocol... HSI Open Protocol Token Passing Connections: Power... Quick Disconnect Terminals RS-485... Quick Disconnect Terminals Computer... 9 Pin/DB9 Male Modem... 9 Pin/DB9 Male 6 York Heating and Air Conditioning Controls ~ Meridian Basic

Notes: York Heating and Air Conditioning Controls ~ Meridian Basic 7

Subject to change without notice. Printed in U.S.A. 036-33060-001 Rev. A (0301) Copyright by Unitary Products Group 2001. All rights reserved. Supersedes: Nothing Unitary 5005 Norman Product York OK Group Drive 73069