The precise step to take

Similar documents
Technical brochure Electrically operated expansion valves, type ETS 6

Electric expansion valves Type ETS 6

Electrically operated expansion valves, type ETS

Electronic suction modulating valves type KVS

Reliable season change

Electric expansion valve Type ETS ETS 400

Electric Expansion Valve Type AKVO 10

Crankcase pressure regulator Type KVL

Electric expansion valve Type ETS ETS 400

Crankcase pressure regulator Type KVL

Solenoid valves Type EVU

CCMT - Electrically operated valves for transcritical and subcritical CO2

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves Type EVU for fluorinated refrigerants

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Assisted lift operated 2/2-way solenoid valves Type EV251B

Electrical Control Valves

Reliable season change

EX3: stepper motor valve with safety embedded solenoid ON/OFF valve

Solenoid valve for R410A and R744 Types EVR 2 - EVR 6 and EVRH 10 - EVRH 40

EX4 / EX5 / EX6 / EX7 / EX8 Electrical Control Valves

Thermostatic expansion valves type TGE 10, TGE 20 and TGE 40

Danfoss Saginomiya 4 - Way Reversing Valves

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

Thermostatic expansion valves type TGE 10, TGE 20 and TGE 40

Maneurop reciprocating compressors MT - MTZ - NTZ

Technical leaflet Thermostatic expansion valves with fixed orifice

Thermostatic expansion valves PHT

Advanced efficiency, precision cooling Design an HVAC system like no other

Advanced efficiency, precision cooling Design an HVAC system like no other

NLE12.6MF.2 Energy-optimized MBP Compressor R134a V 50/60Hz

Electric operated valves Type CCM for R744 / CO2

MAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors R407C - R22 - R410A 60 HZ QUICK REFERENCE

Advanced efficiency, precision cooling Design an HVAC system like no other

SonoSensor 30 Ultrasonic flow sensor

Thermo -Expansion Valves Series TX7

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

HANDBOOK EXPANSION VALVES. Ed EXPANSION VALVES VE-ED 01/ ENG 1

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

Electric expansion valve Type AKV 10P, AKV 10PS

Injection valve, type TXI 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

XV7.2KX Variable Speed Drive Compressor R600a V 50/60Hz

Electric expansion valves Types AKVA 10, 15 & 20

Optyma TM Slim Pack Just mount, braze and plug

50% Raise your efficiency to a higher level. Equipped for silence and top performance. Optyma Plus TM New Generation

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

Solenoid valves type EVR 2 40 NC / NO

Injection valve Type TXI 2

Thermostatic Expansion Valve

Performer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz QUICK REFERENCE MAKING MODERN LIVING POSSIBLE

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

Solenoid valves. Solenoid valves, type PKVD Solenoid valves, type EVR NC / NO

MAKING MODERN LIVING POSSIBLE. Performer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz. Quick reference

Electronically operated expansion valve for CO 2 Type AKVH

A full line of field-tested CO 2 controls, stocked for your convenience

Solenoid valve Types EVR 2 EVR 40 NC/NO

ON/OFF zone valves AMZ 112, AMZ 113

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Valve bodies type RA-N with integrated presetting

R134a R134a R13. 4a R134a R134a R134

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Stainless steel - the strong solution

Colibri Electric expansion valves Type ETS 12C, ETS 24C, ETS 25C, ETS 50C, ETS 100C

EMERSON CLIMATE TECHNOLOGIES-EX

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Thermostatic Expansion

Starting Torque Limiter Type TCI (Soft Start)

Electric expansion valve for R744 (CO 2 ) Type AKVH

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

Solenoid valves type EVSA 25 50

Colibri Electric expansion valves Type ETS 12C, ETS 24C, ETS 25C, ETS 50C, ETS 100C

One. The performance of your wind turbine relies on the quality of its small components. ia.danfoss.com. Brochure Mobile Hydraulic

Solenoid valves EVRA and EVRAT

5-Phase Stepper Motor

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Expansion valves - 2 of 2

Electric Expansion Valves

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

ELIMINATOR Hermetic filter drier Types DML and DCL

Modulating liquid level regulators, direct-controlled SV 1 and SV 3

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Selection & Application Guidelines Performer scroll compressors in parallel installation

PRECISION MOTION CONTROL

Thermostatic Expansion Valve

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Alco Controls. Components for the Refrigeration Industry. Product Selection Catalogue

Automatic controls catalogue E.N. 4

Hybrid Stepper Motors

Capacity regulators (hot gas bypass) PMC and CVC

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

5-Phase Stepper motor

50Hz ZB76KCE-TFD R404A Dew Point

ELIMINATOR Hermetic filter drier Types DCL and DML

SonoMeter 30 Energy Meters

Variable speed application guidelines

Transcription:

New perspectives with Danfoss Saginomiya Electronic Expansion Valves The precise step to take Type KV Electronic Expansion Valves Energy efficiency Precision flow control with high resolution Compact and lightweight Power saving design Proven know-how and high reliability Wide range for all common refrigerants (R41A, R7C, R4A, R134A, R22) as well as CO 2 Bi-flow for heat pump applications REFRIGERATION AND AIR CONDITIONING

General description & background In response to the market shift in the early 8 s, to variable speed compressors and an increased consciousness for energy efficiency, Saginomiya introduced the KV range of stepper motor electronic expansion valves. With over years of experience and know-how the current range of Danfoss Saginomiya valves offer high reliability and precise solutions for expansion and flow control in a wide range of refrigeration and air conditioning systems. Compact and lightweight, the current range are available with different capacities, and can be used with all common refrigerants (R41A, R7C, R4A, R134A, R22) Bi-flow operation is also possible for heat pump systems. A special high temperature range is also available, especially for applications such as hot gas by-pass. In addition to this, a new range of KV valves is also available for trans-critical CO 2 applications. The valve design uses uni-polar drives, and different control solutions exist that are compatible with uni-polar drives. Please, contact Danfoss Saginomiya for more details. Construction & principles of operation The KV electronic expansion valves open and close to regulate refrigerant flow by means of a screw structure which has linear motion. This occurs by the rotation of a magnet-needle valve assembly which moves when electrical signals are applied to the surrouding coil. Within the coil structure, there are different winding configurations, and the polarities are changed by the electrical signals applied. By application of the appropriate combination of signals, in the form of pulses, the coil forces the rotor of the valve to move in a stepwise fashion. Application of multiple pulses will make the valve mechanism move through a series of steps in the direction of choice, in order for the valve to adopt the required position. Permanent magnet motor Coil Needle valve Body Outlet (A*) Inlet (B*) Cross section diagram of KV series * Refers to refrigerant flow in cooling mode Danfoss A/S (pw/mks), 9-28 PLRCA.PB.V1.A1.2 / 52H55 2

Technical data Standard models Maximum working pressure: 42 bar (1 bar for CO 2 models) Compatible refrigerants: R22, R134A, R4A, R7C, R41A and R744 for CO 2 models Ambient temperature: - C to 6 C (- C to 7 C for CO 2 models) Fluid Temperature: UKV *: - C to 7 C UKV-J: - C to 7 C JKV: - C to 7 C VKV: - C to 12 C (- C to 7 C for VKV-D61) AKV: - C to 1 C * models for special high temperature applications (up to 12 C) available upon request Durability: Million total pulses supplied to the valve during operation. (for example this is comparable to 1, operations if the valve is operated between 1 to pulses) Ambient humidity: 95% RH or less Modulation: Permanent magnet type direct operating stepper motor Excitation method: 1-2 phase Electrical connection: JST XHP-6 Excitation speed: min. pps (pulses per second) to max. 8 pps, recommended 31,3 pps ( pps for VKV-D61) Operating range: to pulses, no holding power required (NOTE: do not apply more than 52 pulses) Full motion transit time: e.g. 16 sec @ pps, 6 sec @ 8 pps Installation position: with coil on the upper side and the valve/ coil assembly within +/- 15 of the vertical axis Max. coil temperature: 115 C Valve Specifications Model No. Code No. Orifice [mm] Nominal Capacity [kw] R22 R134a R4A R7C R41A R744 Connection (solder) A [mm] B [mm] Max. MWP MOPD Reverse [bar] [bar] Pressure [bar] Flow direction charecteristic UKV-1D85 61L4176 1, 2,6 2, 1,8 2,7 3,1-7,94 7,94 42 bi-flow [page 5] 1 UKV-14D69 61L4177 1,4 5,8 4,5 4,1 5,9 6,8-7,94 7,94 42 2 bi-flow [page 5] 1 UKV-18D2 61L4121 1,8 1,3 8,1 7,3 1,6 12,1-6, 6, 42 28 bi-flow [page 5] 1 UKV-18D51 61L4165 1,8 1,3 8,1 7,3 1,6 12,1-6, 6, 42 28 bi-flow [page 5] 1 VKV-2D32 61L4122 2, 12,4 9,7 8,7 12,7 14,5-7,94 7,94 42 24 bi-flow [page 5] 1 UKV-25D57 61L41 2,5 19,6 15,3 13,8 2,1 23, - 7,94 42 22 bi-flow [page 6] 1 UKV-D59 61L4166 3, 26,8 2,9 18,9 27,5 31,5-7,94 42 28 15 bi-flow [page 6] 1 UKV-32D61 61L4167 3,2 28,8 22,5 2,3 29,6 33,9-7,94 7,94 42 28 12 bi-flow [page 6] 1 VKV-D61 61L4168 4, 46,4 36,2 32,7 47,6 54,5-12,7 12,7 42 25 3 bi-flow [page 6] AKV-55D3 61L4117 5,5 83,4 65,2 58,8 85,6 98,1-15,88 15,88 42 25 7 bi-flow [page 6] 2 UKV-J14D4 61L4155 1,4 - - - - - 11,2 6, 6, 1 1 - single (B A) [page 7] 1 JKV-2D29 61L4169 2, - - - - - 2,5 7,94 7,94 1 1 - single (B A) [page 7] 8 JKV-24D27 61L417 2,4 - - - - - 28,9 7,94 7,94 1 1 - single (B A) [page 7] 8 Nominal Capacity based on: R41A: CT=38 degc, ET=5 degc, SC= degc, SH= degc, R744: CT=38 degc, CP=1 bar, ET= degc Qty per box Coil Specifications Model No. Code No. Relevant valve model Voltage (current) Cable length [m] Protective tube length [m] Enclosure Insulation class VKV-MOZS3E 61L4114 Coil for VKV-2D and JKV-2D valves 12 VDC (,26A/phase).7.5 IP 66 Class E VKV-MOZS243B 61L4171 Coil for VKV-D and JKV-24D valves 12 VDC (,38A/phase).7.5 IP 66 Class E UKV-A12 61L4142 Coil for UKV valves 12 VDC (,26A/phase).7.6 IP 66 Class E 1 AKV-MOZS816B 61L4119 Coil for AKV valves 12 VDC (,38A/phase).7.5 IP 66 Class E 2 UKV-A111 61L4178 Coil for UKV-J valves 12 VDC (,26A/phase).7.6 IP 66 Class E 1 Qty per box 3 PLRCA.PB.V1.A1.2 / 52H55 Danfoss A/S (pw/mks), 9-28

Application example Heat pump unit Selection method If the operating conditions of the unit are known, a KV valve can be selected easily according to the required capacity. To select the correct electronic expansion valve, it is recommended to define the maximum and minimum refrigeration capacity of the unit. It could be assumed that maximum capacity is required just after starting and the minimum just after stopping operation. In order to calculate the required maximum and minimum capacity, please refer to the tables (pages 5 or 6) for a correction factor corresponding to actual evaporating, condensing and subcool temperatures. Then divide the unit's minimum and maximum capacity by the correction factor, to obtain the required capacities of the valve. Choose the valve for which the number of steps between maximum and minimum capacity is the widest to ensure a sufficient resolution and precision in controlling the capacity. For more details with respect to CO 2 models, please, contact Danfoss Saginomiya. Danfoss A/S (pw/mks), 9-28 PLRCA.PB.V1.A1.2 / 52H55 4

Capacity for R41A Evaporating temp.: -25 C Condensing temp.: C Sub cool: C Superheat: 5 C [kw] 2 Correction factor table Evaporating Condensing temp. temp. [ C] -6 - - - -25-2 -15-1 -5 5 [ C] Superheat=5 C Superheat: 5 C Sub cool[ C] 1 2 6.87 1.6 1.23 1. 1.57 1.73 1.89.91 1.8 1.24 1. 1.56 1.71 1.86.94 1.9 1.24 1.39 1.54 1.68 1.82.95 1.1 1.24 1.37 1.51 1.64 1.77.96 1.9 1.22 1. 1. 1.6 1.72.91 1.9 1.27 1.44 1.6 1.77 1.93.94 1.11 1.27 1.43 1.59 1.74 1.89.97 1.12 1.27 1.42 1.56 1.7 1.84.98 1.12 1.26 1. 1.53 1.66 1.79.98 1.11 1.24 1.37 1.49 1.62 1.74.93 1.12 1.29 1.46 1.63 1.79 1.95.97 1.14 1. 1. 1.61 1.76 1.91.99 1.14 1.29 1.44 1.58 1.72 1.86 1. 1.14 1.28 1.41 1.54 1.67 1.8 1. 1.13 1.25 1.38 1. 1.62 1.74.96 1.14 1.31 1. 1.64 1.8 1.96.98 1.15 1.31 1.46 1.61 1.76 1.91 1. 1.15 1. 1.44 1.58 1.72 1.85 1. 1.14 1.28 1.41 1.54 1.67 1.79 1. 1.12 1.25 1.37 1.49 1.61 -.96 1.14 1.31 1. 1.64 1.8 1.95.99 1.15 1.31 1.46 1.61 1.76 1.9 1. 1.15 1.29 1.44 1.57 1.71 1.84 1. 1.14 1.27 1. 1.53 1.65 -.99 1.12 1.24 1.36 1. 1.59 -.96 1.14 1.31 1. 1.64 1.79 1.95.99 1.15 1.31 1.46 1.6 1.75 1.89 1. 1.15 1.29 1.43 1.56 1.7-1. 1.13 1.26 1.39 1.51 1.64 -.98 1.1 1.22 1.34 1.46 - -.96 1.14 1.31 1.47 1.63 1.78 1.93.98 1.14 1. 1. 1.59 1.73 -.99 1.14 1.28 1.41 1.55 1.68 -.98 1.12 1.24 1.37 1.49 - -.97 1.9 1.2 1.32 1.43 - -.96 1.14 1. 1.46 1.61 1.77 -.98 1.13 1.28 1.43 1.57 1.71 -.98 1.12 1.26 1.39 1.52 - -.97 1.1 1.22 1.34 1.46 - -.94 1.6 1.17 1.28 - - -.95 1.12 1.29 1.44 1.59 1.74 -.96 1.12 1.26 1.41 1.55 - -.96 1.1 1.23 1.36 1.49 - -.94 1.7 1.19 1.31 - - -.92 1.3 1.13 1.24 - - -.94 1.11 1.27 1.42 1.57 - -.95 1.1 1.24 1.38 1.51 - -.94 1.7 1.2 1.32 - - -.91 1.3 1.15 1.26 - - -.88.98 1.9 - - - -.92 1.8 1.24 1.38 1.53 - -.92 1.7 1.2 1.34 - - -.91 1.3 1.16 1.28 - - -.87.99 1.1 - - - -.83.93 1.2 - - - - 15 1 5 VKV-2D32 UKV-18D2 UKV-18D51 UKV-14D69 UKV-1D85 1 2 [Pulse] 5 PLRCA.PB.V1.A1.2 / 52H55 Danfoss A/S (pw/mks), 9-28

Capacity for R41A Evaporating temp.: -25 C Condensing temp.: C Sub cool: C Superheat: 5 C C [kw] 12 Correction factor table Evaporating Condensing temp. temp. [ C] -6 - - - -25-2 -15-1 -5 5 [ C] Superheat=5 C Superheat: 5 C Sub cool[ C] 1 2 6.87 1.6 1.23 1. 1.57 1.73 1.89.91 1.8 1.24 1. 1.56 1.71 1.86.94 1.9 1.24 1.39 1.54 1.68 1.82.95 1.1 1.24 1.37 1.51 1.64 1.77.96 1.9 1.22 1. 1. 1.6 1.72.91 1.9 1.27 1.44 1.6 1.77 1.93.94 1.11 1.27 1.43 1.59 1.74 1.89.97 1.12 1.27 1.42 1.56 1.7 1.84.98 1.12 1.26 1. 1.53 1.66 1.79.98 1.11 1.24 1.37 1.49 1.62 1.74.93 1.12 1.29 1.46 1.63 1.79 1.95.97 1.14 1. 1. 1.61 1.76 1.91.99 1.14 1.29 1.44 1.58 1.72 1.86 1. 1.14 1.28 1.41 1.54 1.67 1.8 1. 1.13 1.25 1.38 1. 1.62 1.74.96 1.14 1.31 1. 1.64 1.8 1.96.98 1.15 1.31 1.46 1.61 1.76 1.91 1. 1.15 1. 1.44 1.58 1.72 1.85 1. 1.14 1.28 1.41 1.54 1.67 1.79 1. 1.12 1.25 1.37 1.49 1.61 -.96 1.14 1.31 1. 1.64 1.8 1.95.99 1.15 1.31 1.46 1.61 1.76 1.9 1. 1.15 1.29 1.44 1.57 1.71 1.84 1. 1.14 1.27 1. 1.53 1.65 -.99 1.12 1.24 1.36 1. 1.59 -.96 1.14 1.31 1. 1.64 1.79 1.95.99 1.15 1.31 1.46 1.6 1.75 1.89 1. 1.15 1.29 1.43 1.56 1.7-1. 1.13 1.26 1.39 1.51 1.64 -.98 1.1 1.22 1.34 1.46 - -.96 1.14 1.31 1.47 1.63 1.78 1.93.98 1.14 1. 1. 1.59 1.73 -.99 1.14 1.28 1.41 1.55 1.68 -.98 1.12 1.24 1.37 1.49 - -.97 1.9 1.2 1.32 1.43 - -.96 1.14 1. 1.46 1.61 1.77 -.98 1.13 1.28 1.43 1.57 1.71 -.98 1.12 1.26 1.39 1.52 - -.97 1.1 1.22 1.34 1.46 - -.94 1.6 1.17 1.28 - - -.95 1.12 1.29 1.44 1.59 1.74 -.96 1.12 1.26 1.41 1.55 - -.96 1.1 1.23 1.36 1.49 - -.94 1.7 1.19 1.31 - - -.92 1.3 1.13 1.24 - - -.94 1.11 1.27 1.42 1.57 - -.95 1.1 1.24 1.38 1.51 - -.94 1.7 1.2 1.32 - - -.91 1.3 1.15 1.26 - - -.88.98 1.9 - - - -.92 1.8 1.24 1.38 1.53 - -.92 1.7 1.2 1.34 - - -.91 1.3 1.16 1.28 - - -.87.99 1.1 - - - -.83.93 1.2 - - - - 1 8 6 2 AKV-55D3 VKV-D61 UKV-32D61 UKV-D59 UKV-25D57 1 2 [Pulse] 6 PLRCA.PB.V1.A1.2 / 52H55 Danfoss A/S (pw/mks), 9-28

Capacity for R744 (CO 2 ) Evaporating temp.: 5 C Condensing temp.: 38 C Condensing pressure: 1 bar [kw] JKV-24D27 25 JKV-2D29 2 15 1 5 UKV-J14D4 1 2 [Pulse] 7 PLRCA.PB.V1.A1.2 / 52H55 Danfoss A/S (pw/mks), 9-28

Dimensions UKV (47) Model No. C D (43) (99) UKV 1D85 UKV 14D69 UKV 18D51 6. D UKV 25D57 NSIONS C 47 UKV D59 UKV 32D61 ype UKV UKV-18D2 VKV-2D UKV 18D2 37 (47) (47) (43) (43) 64 VKV-D AKV-55D ( 67) 12.7 (136) 15.88 (1) (68) (65.5) UKV-J (47) 12.7 (65) JKV-2D (37) 15.88 (64.5) (43) (1) 6. (119) D (99) (99) (112) 44 49 C 6. 6. 47 Catalog No. C D UKV 1D85 UKV 14D69 UKV 18D51 6. UKV 25D57 UKV D59 UKV 32D61 ype VKV-2D 37 Type VKV-D 12.7 49 (112) (68) (136) 64 12.7 (65) ype AKV-55D 56 ( 67) 6. 47 JKV-24D 54 15.88 (1) 15.88 (64.5) (65.5) 54 56 unit mm (119) 28.9.17 Danfoss / Danfoss Saginomiya can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss / Danfoss Saginomiya reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being neccesary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss / Danfoss Saginomiya and Saginomiya and the logotypes are trademarks of Danfoss A/S and Saginomiya. All rights reserved. PLRCA.PB.V1.A1.2 / 52H55 Produced by Danfoss RA Marketing, SW. 9-28