GAS INSULATED VOLTAGE TRANSFORMERS.

Similar documents
Distribution transformers Efficiency over life-cycle

Power Voltage Transformers for Air Insulated Substations

Power and Distribution Transformers

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

3AP1 DTC for 145 and 245 kv

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

PASS M0. Innovative solutions for distribution substations up to 170 kv

Combined instrument transformers

B kv T&D GAS INSULATED SWITCHGEAR

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Gas Insulated Metal-clad Switchgear, HMGS!

Inductive voltage transformers

Inductive voltage transformers

2. INDUCTIVE VOLTAGE TRANSFORMERS Dry and oil-paper insulation

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

Inductive voltage transformers

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

kv А

Gas Insulated Switchgear

EMPAC Metal enclosed capacitor bank for wind applications

Gas Insulated Switchgear

High voltage in motion Environmentally friendly circuit breakers and economic long-rod insulators

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Power Systems PU. HYOSUNG MV Gas Insulated Switchgear. ProGIS[MV GIS]

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Combined instrument transformers

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Our Global Solutions CAPABILITIES

NXPLUS C Single busbar. Maintenance-free for lifetime

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

Metal Clad Air Insulated Switchgear

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Independent Testing Laboratory for High Voltage Equipment

High Voltage Products. COMPASS Compact Prefabricated Air Insulated Substation

B kv Gas-insulated Substations

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Metal Clad Switchgears

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Inductive voltage transformers

132/11 kv, 25 MVA MOBILE SUBSTATION

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Inductive voltage transformers

Inductive voltage transformers

MEDIUM VOLTAGE SWITCHGEAR

8DJ. Maintenance-free for lifetime

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Medium Voltage Metal-Enclosed Switches

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

Inductive voltage transformers

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

Unitole UP kv Primary substations Motor control centres

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

Air-insulated switchgear UniGear type ZS1

To Our Business Partners

Cable current transformers for indoor applications. Product overview. Cable current transformers. for indoor applications.

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

Microgrid solutions Delivering resilient power anywhere at any time

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Substation Concepts for the Future

High Voltage Technology & Testing

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

Nissin s Products for Electric Railway System

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

A of 3. Edition : Date : Page : Document No. Amendments :

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

Key features. DESIGNS: - Conservator type - Hermetically sealed

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

XIRIA Green, Smart, Compact solution

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

IEC Standard Compliant Vacuum Circuit-Breaker (12 kv, 24 kv) for Southeast Asian Markets

This small footprint makes a BIG impact

Transcription:

GAS INSULATED VOLTAGE TRANSFORMERS.

This document may be subject to changes. Contact ARTECHE NISSIN to confirm the characteristics and availability of the products described here.

CONTENTS 1. Presentation 5 2. Manufacturing 6 3. Features 8 4. Accessories 8 5. Range y diagrams 9 6. Quality and Environment 11 7. Service 11 Gas insulated transformers 3

800 kv Single phase transformers (Korea). 170 kv Single phase transformers. We have installed transformers in over 150 countries. 4 Gas insulated transformers

1. PRESENTATION ARTECHE NISSIN borns with the aim to become the reference as independent manufacturer in SF 6 gas insulated transformers market, for Gas Insulated Switchgears. The production plant is located in Vitoria- Gasteiz, in northern Spain with good logistics communications to provide close support and ensuring short delivery times, improving the competitiveness of our customers. ARTECHE NISSIN is a joint-venture between the ARTECHE GROUP and NISSIN ELECTRIC CO., LTD., both companies have extensive worldwide experience in the instrument transformers field and have joined their efforts through ARTECHE NISSIN to become a trustworthy partner for all European GIS substation manufacturers. In ARTECHE NISSIN we share a vision of future for our projects. Innovation is our key to find more efficient solutions through most advanced technologies and resources, which will strengthen further our position in the market, being able to successfully face the challenges set by a transforming sector. 220 kv single phase transformer with isolating device. 420 kv single phase transformer. 145 kv transformer for AIS. Production plant and technical office at Vitoria-Gasteiz (Spain). Gas insulated transformers 5

2. MANUFACTURING Gas insulated VTs are divided into two types. One is single-phase type, the other is three phase type. A three-phase Gas-VT consists of three units of single-phase VT which are enclosed in a tank. Both type Gas-VTs are connected to GIS through an insulator. TERMINAL BOX A terminal box is provided on a side of the tank. A low terminal of primary windings and secondary terminals of secondary windings are brought out in this terminal box through SF 6 gas seal tightness bushings. WINDING Heat-resisting electric wires with synthetic resin coating and plastic film with high dielectric strength, superior heat-resisting, strong mechanical strength and no need to be troubled by moisture are used. Insulation medium among winding layers is SF 6 gas and plastic film. Iron cores are oriented silicon steel plates. FILLING VALVE FOR SF 6 GAS A filling valve for SF 6 gas is provided on a side of the tank. Gas runs between Gas-VT and GIS through this valve in operation. Therefore, monitoring devices for gas leakage and gas pressure are not provided generally on a Gas-VT itself. Through its production plant based in Spain, ARTECHE NISSIN offers in Europe the leading technology in the asian market. Drying and vacuum ovens. Core assembly. 6 Gas insulated transformers

High and steady accuracy, combined with safe design and maximum reliability. Gas insulated transformers 7

3. FEATURES 4. ACCESSORIES Convenient and easy for GIS designing. Gas insulated transformers (Gas- VTs) are designed to be light and compact and furthermore can be connected to GIS in horizontal, vertical or inverted position. Safety. No oil is used as an insulation medium. Therefore, our Gas-VTs are appropriate for indoor use in safety conditions. High-reliability of insulation. A superior distribution of electric field in primary windings ensures high-reliability against incoming surge. Line trapped charge discharging. Line charge, which is trapped after opening the line circuit breaker of a long transmission line or power cable, is discharged through VTs, if either is connected to the power line or cable. Easy for maintenance. SF 6 gas is used as insulation medium like GIS. Thus, its maintenance is easy. Main components are enclosed in SF 6 gas and hermetically sealed. Thus no maintenance is required for them. Voltage transformers include usually the following accessories: Terminal box (1 piece) Secondary (Tertiary) terminal block (1 set) Earth terminal (1 piece) Nameplate (1 piece) Inlet valve for gas (1 piece) Lifting lugs (1 set) Gas Test Unit (GTU). 8 Gas insulated transformers

5. RANGE AND DIAGRAMS ARTECHE NISSIN can manufacture to comply with any national or international standard. All kinds of burdens and accuracy classes can be met. VOLTAGE TRANSFORMERS FOR GIS SINGLE PHASE Connexion typical diagram Single phase Model Highest system Rated primary Power frequency withstand Lightning impulse withstand Switching impulse withstand SVR-6 72,5 66/ 3 140 325 SVR-10 123 110/ 3 230 550 SVR-12 145 132/ 3 275 650 SVR-14 170 154/ 3 325 750 SVR-20 245 220/ 3 460 1.050 SVR-25 300 275/ 3 460 1.050 850 SVR-34 362 345/ 3 510 1.175 950 SVR-38 420 380/ 3 630 1.425 1.050 SVR-50 550 500/ 3 680 1.550 1.175 SVR-80 800 735/ 3 975 2.100 1.550 THREE PHASE Connexion typical diagram Data subject to change without notice. Three phase Model Highest system Rated primary Power frequency withstand Lightning impulse withstand SVTR-6 72,5 66/ 3 140 325 SVTR-10 123 110/ 3 230 550 SVTR-12 145 132/ 3 275 650 SVTR-14 170 154/ 3 325 750 Data subject to change without notice. VOLTAGE TRANSFORMERS FOR AIS Gas insulation > Model UG Model Highest Power frequency Rated insulation level Lightning impulse (BIL) (kvp) Switching impulse (kvp) Thermal burden (VA) Standard creepage distance (mm) UG-123 123 230 550-1.000 3.813 UG-145 145 275 650-1.000 4.495 UG-170 170 325 750-1.000 5.270 UG-245 245 460 1.050-1.000 7.595 UG-300 300 460 1.050 850 1.000 9.300 UG-362 362 510 1.175 950 1.000 11.222 UG-420 420 630 1.425 1.050 1.000 13.020 UG-550 550 680 1.550 1.175 1.000 17.050 Approximate dimensions and weights. For special requirements, please consult. Gas insulated transformers 9

POWER VOLTAGE TRANSFORMERS This type of transformer can supply several kva low power directly from a high transmission line. It offers all the benefits of a potential transformer with the applications of a distribution transformer. APPLICATIONS: 1. Substations auxiliary services power supply: Power supply in conventional substations where low power is needed as a primary or back-up supply; or in remote areas where building distribution lines is unsafe and with unreliable supply that requires frequent maintenance and high costs. It can also be used as a primary power source in switching substations without power transformers to supply the substation and SCADA control systems. 2. Power supply for telecommunication and monitoring systems: High quality electrical supply for booster antennas in remote locations using a transformer connected to a nearby transmission line. 3. Rural electrification of isolated populations: As a power source for supplying reliable power to rural populations in isolated areas where there are no distribution lines nearby, but there are transmission lines. This particular application supplies low power directly from HV line in an economical and practical way. 4. Temporary power supply when building substations, wind farms, etc., and emergency supply during natural disasters. ADVANTAGES: The conventional solution used for the previously mentioned applications is a dedicated medium line. ARTECHE s transformer for auxiliary services has the following advantages: Social benefits. Electrification of isolated rural areas, emergency power after natural disasters... Independent power supply, more flexible as the user does not have to depend on third parties. Cost effective. Quick and flexible solution compared to building new lines, since there is no need to apply for license, conduct environmental studies, use eminent domain, etc.). Highly reliable power source within the substation. Safety for the most critical equipment in the substation (power transformer). Low and auxiliary services are the most unreliable uses. With this solution there is no need for a tertiary winding that could put the power transformer in risk. Dual function, it can be used as a power source and as an instrument transformer in a single unit, since it can also be used for metering and/or protection. PT100 temperature sensor available. Power transformers are designed following both Instrument transformers and power transformers standards: Instrument transformers as per IEC 61869-3, IEEE C57.13. Power transformers as per IEC 60076, IEEE C57.12.00. Model UG > PVT Model Highest Power frequency Rated insulation level Lightning impulse (BIL) (kvp) Switching Impulse (kvp) Burden (kva) Standard creepage distance (mm) UG-72 72.5 140 325-50 2,248 UG-145 123 230 550-100 3,813 145 275 650-100 4,495 170 325 750-100 5,270 UG-245 245 460 1,050-100 7,595 300 460 1,050 850 100 9,300 UG-420 362 510 1,175 950 100 11,222 420 630 1,425 1,050 100 13,020 UG-550 550 680 1,550 1,175 100 17,050 Approximate dimensions and weights. For special requirements, please consult. Model UG 10 Gas insulated transformers

6. QUALITY & ENVIRONMENT Everyone in ARTECHE NISSIN works under the criteria set out in our environmental and quality policy. A sum of regulated procedures based on communication, teamwork, prevention analysis and continuous improvement, common to the whole organization. Advanced sustainability criteria in production and in the creation and development of new products. Compact designs, manufactured with minimal energy consumption and enviromental-friendly materials. Internal and external skill motivation programs. Advanced development of knowledge management. Quality agreements with utilities. Electrical laboratories for testing of products and components according to international standards. Type test reports issued by independent laboratories. Final testing according to specific customer requirements. ISO 9001:2008. ISO 14001:2004. OHSAS 18001:2007. 7. SERVICE Our service is based on a close relationship with the customers, reflected in the integrated post-sale assistance plan and structured client opinion system. In addition to ensuring rapid response, ARTECHE NISSIN developed a continuous service improvement plan, which sustains an extensive training program with courses, publications, conferences, etc. As a part of the ARTECHE Group and NISSIN ELECTRIC, we are an active participant in the electrical organizations such as: IEC, IEEE, CIGRE, CIRED, ASINEL, etc. From its leadership in the asian market, ARTECHE NISSIN has technical offices throughout Europe. To provide effective responses to the requirements of any customer and situation, based on the global knowledge acquired. Exceeding environmental regulations, ARTECHE NISSIN has been able to minimize the use off hazardous materials, energy consumption and waste generation. Routine test at ARTECHE NISSIN s laboratory. Independent laboratory tests. The solutions ARTECHE NISSIN has developed and expanded have made us an active participant in the most important electrical events and organizations. Gas insulated transformers 11

Gerezpea 15 Polígono Industrial Júndiz 01015 Vitoria-Gasteiz SPAIN T. +34 945 069 500 info@artechenissin.com www.artechenissin.com ARTECHENISSIN_CT_2014_EN ARTECHE NISSIN