System 350 S350P Proportional Plus Integral Temperature Stage Module

Similar documents
System 350 S350C Temperature Slave Stage Module

System 350 P352AB Electronic Pressure Control Series

VA-715x Electric Valve Actuator

System 350 A350E Electronic Cooling Control

Damper Actuator Installation

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

A25 Series Warm Air Control with Manual Reset

A419ABG-3C Electronic Temperature Control

M9216 Series Electric Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

AV-8020 Series Floating Control Actuated Valve

VA-715x Electric Valve Actuator

VA-8020 Floating Valve Actuator

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

P66 Series Electronic Fan Speed Controls

System 350 A350R Electronic Temperature Reset Control (with Relay)

VA-720x Electric Valve Actuator

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

EP-8000 Series Electro-Pneumatic Transducers

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

VA-4233-GGx Series Electric Valve Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications

P70, P72, and P170 Controls for Low Pressure Applications

TM-9100 Series Room Command Module

P445 Series Electronic Lube Oil Control

R81EAA-2 Economizer Circuit Board

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

VA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design

VA-7450 Series. Electric Valve Actuators

M100F Incremental Motor Actuator R81F Interface Board

SEN and SEN Outdoor Air Temperature Sensors

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

Series Y63, Y64, Y65, Y66, and Y69 Transformers

F61 Series Standard Flow Switches

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

M9109 Series Electric Non-spring Return Actuators

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

Flare Valves 1/2 inch 2-Way and 3-Way

M9106-xGx-2 Series Electric Non-Spring Return Actuators

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

MS Application. Features. Proportional Valve Actuator General Instructions

M9208-xxx-x Series Electric Spring Return Actuators

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

G72x Series Direct Spark Ignition Controls

CP (Vdc) CP (Milliamp) CP (Slidewire)

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

ATP-2040 Electric Damper Actuator/Transmitter

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

M9300 Series Electric Non-Spring Return Actuators

D-4070 Two Stage Pneumatic Actuator

G76x Direct Spark Ignition Controls

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Metasys Zoning Package Installation

Metasys Zoning Package

ESD5500E Series Speed Control Unit

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

M9220-xxx-3 Electric Spring Return Actuators

MF4E MF4E

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

VA-4233-GGx Series Electric Valve Actuators

A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing

Direct-Coupled ControlSet Actuators (120/180/320 in-lbs.) Installation Guide 2-7/16"

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

MF /MS Series

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

M9210-xxx-3 Electric Spring Return Actuators

I ntroduction. VA-7450 Electronic Terminal Unit Valve Actuator. Features and Benefits

YCCS TE-6800 Series Temperature Sensors

G861 Series Integrated Function. Direct Spark Ignition Control

General Information... 2

RESISTIVITY MONITOR/CONTROLLERS

5001TCP SPEED CONTROLLER

The Temperature Control Company SERIES 2000 / 3020 ANALOG TEMPERATURE CONTROLLERS. Instruction Manual

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

MA-5200 Series MA-5300 Series

TM-11x1 Series Room Temperature Module

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

RUS-L24-MOD Electric 24 Volt Modulating Control Damper Actuator

Installation, Operation and Maintenance. VA(M)S24-27 (T)-T Series Actuator

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Q35 Series Automatic Vent Damper System

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

TC62D Installation Instructions

Transcription:

FANs 930, 930.5 Add-On Modules Section Product/Technical Bulletin S350P Issue Date 0997 System 350 S350P Proportional Plus Integral Temperature Stage Module The S350P is used in conjunction with the A350 Temperature Control to add proportional or proportional plus integral staging capability. The S350P is an electronic control with analog 0 to 10 VDC and 0 to 20 ma outputs. As with all System 350 products, the S350P is housed in a NEMA 1, high-impact plastic enclosure. The modular design provides easy, plug-in connections for quick installation and future expandability. Plug-in Connectors and 35 mm DIN Rail Mountability Features and Benefits Figure 1: S350P Electronic Proportional Plus Integral Temperature Stage Module Eliminates wiring between modules and reduces installation costs Proportional or Proportional Plus Integral Output Minimum Output Adjustable from 0 to 60% Adjustable Throttling Range of 2 to 30F (1 to 17C ) Field-selectable Reverse or Direct Acting Mode Three User-selectable Integration Constants Light-Emitting Diode (LED) Bar Graph Display of Output Adds proportional or proportional plus integral staging capability to all A350 Temperature Controls Tailors the output to the requirements of the controlled device; can also be used to set minimum valve or damper position Enables the user to tune the system for optimum performance Works in heating or cooling applications Provides selection of the integration constant for applications requiring proportional and integral control Aids in adjustment, tuning, and troubleshooting 1997 Johnson Controls, Inc. 1 Part No. 24-7664-1202, Rev. Code No. LIT-930086

A pplication Overview The S350P Proportional Stage Module must be used in conjunction with an A350 Temperature Control. The S350P receives its power, setpoint, and sensor inputs from the A350. The S350P adds a proportional or proportional plus integral output to the A350 control. The maximum number of stages that can be used in a system varies with the type of control module (on-off, proportional, or reset), type of stage module (on-off, slave, or proportional), and type of power supply (external transformer or Y350R). Use the following table to determine the maximum number of stages that may be used with each control module. O peration IMPORTANT: All System 350 controls are designed for use only as operating controls. Where an operating control failure would result in personal injury and/or loss of property, it is the responsibility of the installer to add devices (safety, limit controls) or systems (alarm, supervisory systems) that protect against, or warn of, control failure. Table 1: Maximum S350 Stage Modules per Control Module Control A350A, A350B, A350E, A350R, A350S (using Y350R) A350P (using Y350R) Any A350 (using external 40 VA transformer) Maximum S350A or S350C Stage Modules Maximum S350A or S350C (with 1 S350P) Maximum S350A or S350C (with 2 S350P) 9 6 4 4 2 N/A 9 8 7 The S350P is powered by the A350, and provides two simultaneous analog outputs: 0 to 10 VDC and 0 to 20 milliamperes (ma). A cover-mounted, ten segment LED bar graph indicates the percentage of output currently in use. S350P features include: adjustable offset selectable Reverse Acting (RA) or Direct Acting (DA) mode of operation adjustable throttling range (proportional band) adjustable minimum output selectable integration constant Cover Screws (Quantity = 4) Integration DIP Switch Slow Off Medium Fast TH R OT R AN GE MIN OUTP UT OF F SET Module Connector 1 2 3 4 O N LD Indicator (Percent of Output) V C I Reverse Acting Direct Acting Operation Mode Jumper Positions Figure 2: Interior View Illustrating S350P Features 2 Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin

Offset The offset can be adjusted from 0 to 30F (0 to 17C ). The offset adjustment determines the amount of offset between the A350 s setpoint and where the S350P s throttling range begins (refer to Figure 5). This adjustment is made using the potentiometer marked OFFSET located at the upper portion of the circuit board (refer to Figure 2). Mode of Operation (Direct Acting or Reverse Acting) When configured for Reverse Acting (RA) operation, the analog output increases as the temperature drops below the value of the A350 s setpoint minus the S350P s offset (refer to Figure 3). When configured for Direct Acting (DA) operation, the analog output increases as the temperature rises above the value of the A350 s setpoint plus the S350P s offset (refer to Figure 3). Select the RA/DA mode by positioning the operation mode jumpers either vertically or horizontally (refer to Figure 2). Position the operation mode jumpers vertically for Reverse Action (RA) or horizontally for Direct Action (DA). As shipped from the factory, the RA/DA operation mode jumpers are installed in the RA mode. 30 25 20 15 Throttling Range RA 10 5 A350 Setpoint Minus S350P Offset 10 VDC 5 5 0 10 0 DA 5 10 15 20 25 30 Throttling Range A350 Setpoint Plus S350P Offset Figure 3: Direct or Reverse Acting Proportional Bands Shown in Proportional Only Mode (Shaded Area Shows Throttling Range Possibilities from Minimum to Maximum) Throttling Range (Proportional Band) The throttling range can be adjusted from 2 to 30F (1 to 17C ). Make the adjustment at the throttling range potentiometer marked THROT RANGE (refer to Figure 2 ). Included with the S350P is a Celsius scale throttling range decal. If the Celsius scale is desired: 1. Use a small screwdriver to pry underneath the existing decal and remove it along with the throttling range, minimum output, and offset potentiometer knobs. 2. Apply the Celsius scale decal where the original decal was located. 3. Rotate all knob stems completely counterclockwise. 4. Reinstall the potentiometer knobs so the arrows are at the furthest counterclockwise scale position (refer to Figure 2). Minimum Output Adjustment The minimum output adjustment sets the minimum voltage or milliampere output provided by the S350P. It can be adjusted from 0 to 60% (0 to 6 VDC or 0 to 12 ma) of the output range. Example: A controlled device responding to a 4 to 20 ma output would require the minimum output to be adjusted to 20% or 4 ma (refer to Figure 4). The minimum output adjustment may also be used to set valves or dampers to minimum position. Make the adjustment at the minimum output potentiometer marked as MIN OUTPUT (Figure 2). For each 10% increase in range, one bar on the LED indicator appears. Note: Before setting the minimum output potentiometer, be sure the control is not generating an analog output signal. Output (ma) 20 10 4 0 0 50% 20% 2 4 6 0% 8 10 12 14 16 18 20 Deviation Above Setpoint Figure 4: Output vs. Deviation from Setpoint for: Minimum Output = 0, 20, and 50%, Throttling Range = 20 F Direct Acting Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin 3

100% Throttling Range = 6 o F 80% % Output 60% 40% 20% Offset = 4 o F Minimum Output =20% Direct Acting 72 74 76 78 80 82 84 A350 S350P Calculated Temperature o F Setpoint = 72 o F Setpoint = 76 Figure 5: Example of S350P Adjustments o F Integration Constant Proportional only controls cannot hold a process at the exact setpoint. A proportional offset is always present because the control output is 0% at setpoint. Any load on the system causes the control point to be offset from the setpoint. The greater the load on the system, the further the control point offsets from the setpoint (this is commonly referred to as proportional offset) and under maximum load this error approaches the throttling range. Some proportional only controls are designed with their setpoint located midway through the proportional band to help compensate for the offset. This results in a plus/minus error from the setpoint rather than a single-ended error. The S350P has an integration feature that forces the control point to match the S350P calculated setpoint. Over time, the S350P controls the heating/cooling equipment to balance the system load at the calculated setpoint (refer to Figure 6). On traditional proportional plus integral controls, the amount of correction becomes too large if the system load exceeds the capacity of the equipment. When the actuated device (valve or damper) is fully open or closed and the setpoint still cannot be reached, the integration error continues to grow. The result is called integral windup. The S350P avoids integral windup with a patented circuit that puts a dynamic ceiling on the integrator. This circuit resets the integration error when the sensor goes just above the calculated setpoint plus the throttling range (in DA mode) or just below the calculated setpoint minus the throttling range (in RA mode). This allows the process to recover from an out-of-range condition without a large overshoot. The S350P has three field-selectable integration constants and an off position. The integration DIP switch selects the integration constant. (Refer to Figure 2 for location.) The field-selectable integration constants include: Off (Switch 1 to On position, all others Off) Provides proportional only operation. Slow (C3) (Switch 2 to On position, all others Off) This is the slowest integration constant (equal to 26 minutes) and is suitable for most proportional plus integral applications. Slow is the recommended initial setting. Medium (C2) (Switch 3 to On position, all others Off) Selects a 13-minute integration constant. If the rate of system recovery to setpoint is sluggish with the control set to slow, and if the system has enough capacity to drive the process to setpoint at a faster rate, the medium setting may be used. Fast (C1) (Switch 4 to On position, all others Off) This is the fastest integration constant (equal to 6.5 minutes). Use the fast setting only in instances where the rate of change at the sensor is extremely rapid and system capacity can compensate for that rapid change. 4 Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin

Proportional Only Control Proportional Offset Temperature S350P Calculated Setpoint Error Load Change Time System Load Control Point Follows the Load Throttling Range Proportional Plus Integral Control Proportional Offset = 0 Temperature S350P Calculated Setpoint Error Load Change Time System Load Integration adjusts the proportional output to bring the process to setpoint regardless of load. Figure 6: Operation of Proportional Only vs. Proportional Plus Integral Control Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin 5

D imensions 0.145 3.68 Mounting Slot for No. 6 Screws 0.5 13 2.94 75 5.00 127 S350P 1.56 40 0.42 11 DIN Rail Mount 2.40 61 2.40 61 0.85 22 0.875 22 Conduit Hole Figure 7: S350P Dimensions, in./mm 6 Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin

Installation and Wiring The S350P Temperature Control is housed in a compact NEMA 1 plastic enclosure designed for standard 35 mm DIN rail mounting. The S350P is not position sensitive but should be mounted for convenient wiring and adjustment. Four key-slot mounting holes on the back of the control case are provided should surface mounting be required. Note: When mounting the S350P (or any System 350 module) to rigid conduit, attach the hub to the conduit before securing the hub to the control enclosure.! WARNING: Shock hazard. Disconnect power supply before wiring connections are made to avoid possible electrical shock or damage to equipment. Install all wiring to conform to the National Electrical Code and local regulations. For maximum electrical rating of control, refer to the label inside the control cover. Only use copper conductors. The S350P can produce a variable signal from 0 to 10 VDC or 0 to 20 ma. (Both outputs can be used simultaneously.) Connections are made to the terminal block located in the wiring compartment at the bottom of the case. Connections can be made to both the voltage and milliampere outputs, allowing the S350P to drive two outputs off the same RA or DA ramp simultaneously. This feature can be used to drive motor actuators of several different types in a single application. Table 2: Terminal Designations Terminal Designation V COM I 0 to 10 VDC output Common 0 to 20 ma output Terminal Description A djustments Follow these procedures to set up the S350P for the types of operation desired. 1. Remove S350P cover by loosening the four cover screws (Figure 2). 2. Set the RA/DA operation mode jumpers to the desired mode of operation. Position the operation mode jumpers vertically for RA (Reverse Acting) or horizontally for DA (Direct Acting) (Figure 2). 3. Adjust the offset potentiometer to the number of degrees from the A350 control s setpoint that the S350P begins throttling. Clockwise rotation increases offset. 4. Adjust the throttling range potentiometer to desired setting. Rotate clockwise to increase the throttling range. Note: Included with the S350P is a Celsius scale throttling range decal. Refer to the Throttling Range (Proportional Band) section of this bulletin for decal installation instructions. If the S350P is to be used in proportional plus integral mode, the initial throttling range adjustment is seldom set below 6F (3C ). A narrow proportional band used in conjunction with the integration may result in unstable control. 5. If minimum output is required, set the minimum output potentiometer (labeled MIN OUT) to the desired position (Figure 2). Output can be read with a voltmeter or can be adjusted using the ten segment, front panel LED. Note: Before setting the minimum output potentiometer, be sure the control is not generating an analog output signal. For each 10% increase in range, one bar lights on the LED bar graph. In a milliampere application, each bar equals 2 ma. In a voltage application, each bar equals 1V. (Refer to Figure 4 for an example.) Example: To set the S350P for a minimum output of 4 ma, turn the minimum output potentiometer clockwise until the second LED segment lights. Slowly rotate the potentiometer counterclockwise just until the second segment disappears. Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin 7

6. Make sure the system is stable in the proportional mode before selecting integration. Refer to Checkout Procedure. 7. Reinstall the cover and secure in place with the four cover screws. C heckout Procedure Follow this procedure to ensure the S350P is connected and functioning properly. 1. Before applying power, make sure that the installation and wiring connections comply with job specifications. 2. Set the system for the proportional mode and tune it for stable operation. 3. After making adjustments and electrical connections, put the system into operation and observe at least three complete operating cycles to determine that the system is stable. 4. If integration is required, select the Fast (C1), Medium (C2), or Slow (C3) integration constant. Slow is the recommended initial setting. (Refer to the Integration Constant section of this bulletin.) 5. Observe operation and make additional adjustments as necessary to obtain stable control. T roubleshooting If the control system does not function properly, verify the proper operation mode is selected on each module (e.g., RA/DA) and perform the following: 1. Check for proper voltage applied to the A350 control. a. Connect a Digital Voltmeter (DVM) between the 24V (+) and C (-) terminals located on the A350 s left side terminal block. If an external transformer is used, select AC volts on the DVM and verify that the voltage is between 20 and 30 VAC. If a Y350R Power Module is used, select DC volts on the DVM and verify that the voltage is between 16 and 38 VDC. If an external DC power supply is used, select DC volts on the DVM and verify that the voltage is between 22 and 29 VDC. b. If the DVM voltage is within the indicated voltage range, proceed to Step 2. c. If the DVM voltage is not within the indicated voltage range, check wiring, and then replace the Y350R or the external transformer. 2. Check temperature sensor for proper resistance. a. Take an independent temperature reading at the sensor location (T s ). Allow the thermometer to stabilize before taking the reading. b. Disconnect the sensor from the control. Using an ohmmeter, measure the resistance across the two sensor leads. Consult the Temperature vs. Resistance Chart (Figure 8) to verify sensor conformity. c. Replace the sensor if its actual performance deviates substantially from that represented on the chart. Temperature Note: F C 260 121 240 110 220 98.8 200 87.7 180 76.6 160 65.5 140 54.4 120 43.3 100 32.2 80 21.1 60 10 40-1.1 20-12.2 0-23.3-20 -34.4-40 600 800 1000 1200 1400 1600 1800 2000 Resistance in Ohms Figure 8: Temperature vs. Resistance Chart for the SET189A Series Sensor The sensor reading indicated by the D350 may differ somewhat from thermometer readings due to sensor tolerances, time constants, thermometer accuracy, and other factors. 8 Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin

3. Check the S350P for proper operation. Note: Steps 1 and 2 must be performed first. a. Reconnect the sensor to the A350 and re-apply power. b. Turn the A350 s setpoint to minimum. c. On the S350P, turn the throttling range and the minimum output to the minimum position by turning both potentiometers counterclockwise. Switch the integration off and select the RA mode. d. Adjust the minimum output to the maximum position by turning the potentiometer clockwise. As the potentiometer is turned clockwise, the LEDs in the bar graph should turn on from left to right until the fifth or sixth bar is on. If they do not, replace the S350P. Note: e. Adjust the minimum output to zero again and select the DA mode. The V output voltage should be greater than or equal to 10 VDC, the I current output should be greater than or equal to 20 ma, and the rightmost LED should be on. If not, replace the S350P. f. Slowly increase the setpoint on the A350. The LEDs should turn off from the right side to the left side of the bar graph, until all are off (indicating that the A350 setpoint dial has reached a value equal to the sensor temperature minus the S350P s offset). If they do not, then replace the S350P. Although unlikely, it is possible that a defect in one S350 could cause defective symptoms in all modules. Plug each stage module into the A350 and individually check its performance as outlined in Steps 3a to 3f. Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin 9

R epairs and Replacement Do not make field repairs or perform calibration. SET189A Temperature Sensors and replacement controls are available through local Johnson Controls representatives. O rdering Information Table 3: Ordering information Product Code Number S350PQ-1C Description Electronic Proportional Plus Integral Temperature Stage Module 10 Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin

Notes Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin 11

Specifications Product Input Voltage S350P Proportional Plus Integral Temperature Stage Module 5 VDC Reference Provided by the A350; 24V Power Supply Ambient Temperatures Operating: -30 to 150 F (-34 to 66 C) Shipping: -40 to 185 F (-40 to 85 C) Humidity Analog Outputs Minimum Output Output Indication Mode of Operation Offset Range Throttling Range Integration Constant Material Agency Listing 0 to 95% RH Non-condensing; Maximum Dew Point: 85 F (29 C) 0 to 10 VDC (550 ohm Load Minimum) and 0 to 20 ma (600 ohm Load Maximum) Adjustable from 0 to 60% of the Output A ten segment LED bar graph indicates percentage of output. Direct or reverse action is jumper selectable. 0 to 30F (0 to 17C ) 2 to 30F (1 to 17C ) Four Selectable Rates: Fast, Medium, Slow, and Off Case, Cover: NEMA 1 High-impact Thermoplastic UL Guide No. XAPX and cul Guide No. XAPX7, File E27734 The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 Printed in U.S.A. 12 Add-On Modules S350P Proportional Plus Integral Temperature Stage Module Product/Technical Bulletin