Highline Super-Hi High Gallonage Model No. Description. Load Table. Operating Environment. Performance Requirements

Similar documents
Highline Standard Gallonage Dispenser. Load Table. Operating Environment. Performance Requirements

Dimension Series One, Two, Three and Four Grade Dispensers

Load Table See attached wiring diagrams:

Related Manuals Pump and Dispenser Start-Up/Installation Manual Flow Restrictor Installation Manual

The Advantage and Optimum Dual and Quad Pumps and The Advantage Super-Hi Dual Pumps

Available Models and Weights

Salesmaker Series Pumps And Dispensers Illustrated Parts Manual

PT Optimum Series Illustrated Parts Manual

GASBOY FLEET & COMMERCIAL

The Advantage Series. Pump & Dispenser Specifications MDE-3807A

4Fiilbarco. Illustrated Parts Manual. Salesmaker 4. Pumps & Dispensers PT1554 I DEC85

Nozzles Lane-oriented and High-hose Attachment Downloadable Software. Endress & Hauser LPG Mass DN15 Diesel Exhaust Fluid (DEF)

Electronic Assemblies, Dials & Schematics. Electronic Enclosure Assembly (1 and 2 lamp system) , 3-3 (3 and 6 lamp system)...

MDE-2833D. Pumps and Dispensers. Site Preparation For Use With: All Gilbarco pumps and dispensers

SELECT TM SERIES ELECTRONIC FLEET FUEL DISPENSERS

GREASE CONTROL GUNS GREASE CONTROL GUNS Grease control gun Grease control gun with rigid stem and 3 jaw connector ( ).

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

RELIANCE G6200 MECHANICAL FLEET DISPENSER

PRODUCING TRUST IN FIRE AND SAFETY FIRE PUMP SYSTEMS A PRODUCT OF COMPLIANT.

NETSIAN TECHNOLOGY VALVE SCHEDULE

Display Installation. page 1 of 9 pages. Engineering Standards. Engineering Standard Number C A. Name Identifier

12-VOLT PUMPS CHOOSING A GPI ELECTRIC GEAR PUMP

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

Purpose Of This Document This manual provides the information to assemble and install Lighted Canopy Conduit Kits on The Advantage Series.

Parts List GoPump C-series & R-series, Spec 2000 or Higher

Accu-Guard Compact + Ideal for Industrial / Manufacturing Applications or Shop Environments. Take complete CONTROL of your fluid inventory.

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM

High. performance. Encore

Standard Features and Options M07300A001*1, M07300A002*1, M07300A003*1, M07300A004*1, M07300A005*1, M07300A006*1

Portable Fuel Dispensing Equipment

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

12 Volt DC Diaphragm Pumps Series 400

Control Valves/Meters Grease

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.

NEW AUTOJET PRECISION SPRAY CONTROL SYSTEM WITH ZONING

Nozzles Lane-oriented and High-hose Attachment Back-lighted Liquid Crystal Displays (LCD)

WAYNE OVATION HS ULTRA-HIGH-CAPACITY FUEL & DEF DISPENSERS. The art of speed

fusion RF Control Handle

OBSOLETE DESIGN DATA. 3", 4", 6" and 8" CONCENTRATE CONTROLLERS

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

MA-5200 Series MA-5300 Series

DEF DISPENSING AND STORAGE

AC-DC POWER SUPPLY SINGLE OUTPUT, DESK TOP, 130 WATTS MEDICAL APPLICATIONS MUIG130 SERIES

Fuel Dispensing & Accessory Packages

Page 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location

W-300-AST Specifications

Belt Scales Table of Contents

Model 1210C Battery Powered Pump Shown

500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION

Pressure Independent Control Series

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

WAYNE HELIX TM FUEL DISPENSER ALTERNATIVE ENERGY SOLUTIONS. Designed for you. world

590G Series Golf Spray Head. 590G Series Golf Spray Head. Variable Arc 4, 6, 12 Pop-up X-Flow and Check-O-Matic Standard.

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Reliance G6200 Mechanical Fleet Dispenser

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

2062 ½ NPTM x ¼ NPTF bushing ½ NPTM x 3/8 NPTF bushing ½ NPTM x 3/8 NPTF bushing

OPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

2 Fluid Level Management

Who we are, what we do

TECHNICAL BROCHURE BHSJ. Basic Convertible Pump HSJ MULTI-STAGE CONVERTIBLE JET PUMPS - 60 HZ

MS Application. Features. Proportional Valve Actuator General Instructions

PROFESSIONAL GRADE FUEL TRANSFER PUMPS CATALOG

MF4E MF4E

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

BRUTE II 4-VALVE Manifold

FR600G Series AC Transfer Pumps

Committee Chair, National Type Evaluation Program Committee Issued: December 27, M Street, Suite 110 / Lincoln, Nebraska 68508

Pressure Independent Control Series

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

MDE-2381A SERVICE MANUAL. PA0242 Distribution Box GILBARCO INC., 7300 W. FRIENDLY AVENUE, P.O. BOX 22087, GREENSBORO, N.C /90/.

Vapor Recovery Assist System

SOLURA BLUE DEF DISPENSING SOLUTIONS. SOLURAbLUE

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

Self-Operating Temperature Regulators


A-dec 200 P RE-INSTALLATION GUIDE

Model FVP General Specification. Flanged Vortex Plate. Product Features

Dresser Wayne Reliance S1 Mechanical Registration AST Fleet Model G6101D Remote Dispenser

SERIES WC & WCS. Watchman Series & WCS Condensate Units. Replacement Parts for. Hoffman PARTS LIST DN0436. Hoffman Pump

Centurytm Series Fuel Dispenser

3" Steel Model E3. We put you first. And keep you ahead.

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

PRODUCT OF FIRE PUMPS SYSTEMS

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

SANKI is a leading refueling equipment manufacturer in China and leads the industrial technical progress with science and technology.

Belanger Tunnel Equipment Quick Reference Guide REV 02

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

STANDARD FOR TESTING AND RATING PERFORMANCE OF PRESSURE WASHERS: DETERMINATION OF PRESSURE AND WATER FLOW

IST INTELLIGENT SUBMERSIBLE TURBINE

2 PETROLEUM AND LP-GAS TANK TRUCK METERS

Vortex Plate. Model VP General Specification. Product Features

DT34 and DT54 Series Rotary Sprinklers

CHAPTER 4 PARTS PARTS BY PICTORIAL. This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation.

RAZOR. RAZOR HVLP Spray Guns

Flowrite 599 Series Two-Way Valves 1/2 to 2-inch Bronze Body

Transcription:

Specifications Highline Super-Hi High Gallonage Model No. Description AC4982A-MS1 Super-Hi Single One-Product Master Dispenser AC7942A-MS1 Super-Hi Master/Satellite Combo Dispenser Load Table See attached wiring diagrams. Domestic FE-238A Highline High Gallonage Master Satellite System 110/115/120 VAC FE-240A Highline High Gallonage Combo Master Satellite System 110/115/120 VAC Export FE-252A Highline High Gallonage Master Satellite System 220/230/240VAC FE-253A Highline High Gallonage Combo Master Satellite System 220/230/240VAC Operating Environment Relative Humidity... 20% to 95% non-condensing Minimum Outside Ambient Temperature...-22 F (-30 C) Maximum Outside Ambient Temperature...113 F (45 C) Performance Requirements Minimum Delivery Rate...30 gpm @ 35 psi inlet pressure...(114 lpm @ 102 kg/cm 2 inlet pressure) or when teamed with a satellite...40 gpm @ 26 psi inlet pressure...(152 lpm @ 76 kg/cm 2 inlet pressure) Meter Accuracy...±.25% from 1.5 to 15 gpm (5.7 to 57 lpm) Weights Super-Hi Single One-Product Dispenser Weight...335 pounds/151 kilograms Super-Hi Master/Satellite Combo Dispenser Weight...390 pounds/176 kilograms MDE-2530-25 Pump and Dispenser Installation Manual 07/92 Page i

$ $ THIS SALE GALLONS PRICE/GALLON PUMP ON TAXES INCLUDED PUMP OFF Model Number Breakdown Hydraulics AC X X X X X X XXXXX A. U.S. C. Electronic Pump or Dispenser B. Highline Series F. International Highline Series A. Dispenser, Standard Gallonage B. Pump, Standard Gallonage C. Dispenser, Conventional High Gallonage D. Pump, Conventional High Gallonage E. Dispenser, Conventional High Gallonage Master (for satellite) F. Dispenser, Satellite (less CD module) G. Pump, PUS High Gallonage (with 1 piping) J. Pump, PUS Intermediate Gallonage (with 3/4 piping) K. Dispenser, Super-Hi High Gallonage Master (for satellite) L. Dispenser, Ultra-Hi High Gallonage Master (for satellite) M. Dispenser, Ultra-Hi Satellite (less CD module) N. Dispenser, Ultra-Hi High Gallonage Combo (with satellite) P. Pump, Standard Gallonage (with sump flow control) R. Pump, Conventional High Gallonage (with sump flow control) S. Dispenser, Conventional High Gallonage Combo (with satellite) T. Dispenser, Super-Hi High Gallonage Combo (with satellite) 2. Pump, PUS Intermediate Gallonage (with 3/4 piping and sump flow control valve) A. Single Product B. Dual One-Product C. Dual Two-Product D. Dual One-Product (rotated nozzle putdowns) G. Single Product (rotated nozzle putdowns) B. U.S. Gallons Totalizers, Vapor Recovery Nozzle Hook and Boot K. Metric Totalizers, Vapor Recovery Nozzle Hook and Standard Boot G. Metric Totalizers, Standard Nozzle Hook and Vapor Recovery Nozzle Boot N. Imperial Gallons Totalizers, Vapor Recovery Nozzle Hook and Standard Boot A. Fillup B. Preset A. First Major Revision M. Universal Hydraulics (value analyzed) Reference MFG. BY GILBARCO INC. GREENSBORO N.C. U.S.A. MODEL AM2222A DIESEL SERIAL HX BA053865 HYDRAULIC MODEL ACZPDKBOAJ001 TRANSAC U L 12 UNDERWRITERS LABORATORIES INC POWER OPERATED DISPENSING DEVICE FOR FLAMMABLE LIQUIDS FOR USE ONLY WITH UL LISTED INTERCHANGEABLE SERVICE STATION TYPE HOSE NOZZLE VALVE H SERIAL MODEL ACZPDKBOAJ001 MFG. BY GILBARCO INC. GREENSBORO N.C. U.S.A. Page ii MDE-2530-25 Pump and Dispenser Installation Manual 07/92

Model Number Breakdown Electronics CP1 XX X X X X X X X X Basic Model Number Modular Electronics Minor Options 0 - Standard 1 - Corrosion Resistant 2 - Special Liter Software Series Mounting Post 01 - Highline 0 - Single Post Dispenser 02 - Highline Salesmaker-1 2 - Dual Post Pump 03 - Highline Salesmaker-2 3 - Single Post Pump 12 - Salesmaker-1 High Gallonage 4 - Dual Post Dispenser Hose Configuration Customer Option Location 1 - One Hose 1 - None 2 - Two Hose 2 - Bezel Mounted 3 - External Source Voltage Customer Options 0-115VAC 60Hz 0 - Standard 1-220VAC 50/60Hz 1 - Pump Preset 2-230VAC 50/60Hz 2 - Cash/Credit 3 - Variable Voltage 3 - Cash/Credit and Pump Preset Main Display Configuration Display System 0 - Standard 5 - Liquid Crystal - Comma/Decimal 1 - Single Sided 0 - SID - Comma 3 - SID - Decimal Thirteen digit electronics model number is stamped on plate attached to bottom of electronics module. 1 2 3 F1 4 5 6 F2 7 8 9 0 SERIAL MODEL CP10920001000 MFG. BY GILBARCO INC. GREENSBORO N.C. U.S.A. MDE-2530-25 Pump and Dispenser Installation Manual 07/92 Page iii

Elevation Highline Super-Hi High Gallonage Dispenser Single One-Product Master or Master/Satellite Combo 24-1/2" 8" Single does not have this putdown. 35-1/2" 51-3/4" 61-1/2" 46-13/16" 36" 1-29/32" 27" 4" 12" 16-1/16" Screening Specifications Lower Doors Overall: 40.8 H x 28.34" W (Total Blank Area) Flat Surface: 32.28" H x 18.67" W (Maximum Viewing Area) Brand Panels Overall: 2.24" H x 21.5" W Screening Area: 1.86" H x 20.88" W Page iv MDE-2530-25 Pump and Dispenser Installation Manual 07/92

Footprint Highline Super-Hi High Gallonage Dispenser Single One-Product Master 1" Discharge Sending Product To Satellite (2) 13/16" x 1-13/16" Long Slots For Anchor Bolts (4) 13/16" x 1-13/16" Long Slots For Alternate Anchoring (4) 9/16" Dia. Holes 16-1/16" 15-11/16" 1-3/4" 10-3/8" 4 1/4" 1-3/4" 6-1/2" 7-27/32" 1 27" 1" Discharge Receiving Product From Master - Combo Units Only (3) Openings For 1" Conduit C L (2) 1" Discharge Unions "A" Side Junction Box 9-1/2" 7-1/2" 1-29/32" 1-3/8" 1-1/2" Supply Union MDE-2530-25 Pump and Dispenser Installation Manual 07/92 Page v

Footprint Highline Super-Hi High Gallonage Dispenser Master/Satellite Combo 1" Discharge Sending Product To Satellite (2) 13/16" x 1-13/16" Long Slots For Anchor Bolts (4) 13/16" x 1-13/16" Long Slots For Alternate Anchoring (4) 9/16" Dia. Holes 16-1/16" 15-11/16" 1-3/4" 10-3/8" 4-1/4" 6-1/2" 7-27/32" 1 27" C L (3) Openings For 1" Conduit "A" Side Junction Box 9-1/2" 7-1/2" 1-29/32" 1-3/8" 1-1/2" Supply Union Page vi MDE-2530-25 Pump and Dispenser Installation Manual 07/92