Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

Similar documents
Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac 3-Position (Floating) Control

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Flowrite EA 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Flowrite 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

SKD62UA Series Electronic Valve Actuator, Advanced Features

SAX Electronic Valve Actuator

SKD U Electronic Valve Actuator

SKD U Electronic Valve Actuator

SAX Electronic Valve Actuator

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Proportional Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Floating Control

Technical Data 1 /2 3 / /4 1 1 /2 2. Cv TABLE

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

SAV Electronic Valve Actuator

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam

Powers TM Controls EA 338 Electronic Actuator

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

Technical Instructions Document No P25 EA GMA January 19, OpenAir. GMA Series Spring Return Rotary Electronic Damper Actuators

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Technical Instructions Document No P25 EA GMA May 19, OpenAir. GMA Series, Spring Return, 62 lb-in, Rotary, Electronic Damper Actuators

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

VE VVG Series Electronic Two-way Valves Normally Closed

OpenAir GCA Series Spring Return 142 lb-in Electronic Damper Actuators

Flowrite AP 599 Series

599 Series Zone Valves

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Flowrite TM AP 599 Series 8-inch Pneumatic Valve Actuator

Electro-hydraulic actuators for valves

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

Flowrite 599 Series High Pressure Close-Off 2-Way Valves, 2-1/2 to 6-Inch, Flanged Iron Body, ANSI Classes 125 & 250

MF /MS Series

OpenAir. Technical Instructions. GCA Series Spring Return 160 lb-in Electronic Damper Actuators. Document No P25 EA GCA-1.

Packing Replacement Kit for Flowrite VF 599 Series Valves

Rebuild/Repack Kits for Flowrite VF 599 Series 2-1/2 to 6-inch Valves

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Electro-hydraulic actuators for valves

MF Series MS Series

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Commercial Actuator Selection Chart Non-Spring Return

Electrohydraulic actuators for valves

Electro-hydraulic actuators for valves

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Electrohydraulic actuators for valves

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Pressure Independent Control Series 2-Way Valves and Electronic Valve Actuators

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

599 Series 6-Way Ball Valves

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

VA-715x Electric Valve Actuator

Flowrite VF 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

VA-4233-GGx Series Electric Valve Actuators

Pressure Independent Control Series

Flowrite 599 Series Two-Way Valves 1/2 to 2-inch Bronze Body

SED2-BT300-XX-C09 Migration Kits. Product Numbers

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

MXF461 U Series Modulating Control Valves with Magnetic Actuators

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

Pressure Independent Control Series

Powers TM Controls RL 243 SW Switching Relay

DC-132 Non Spring Return Electronic Actuator Series

SQM5 Reversing Actuator with Analog Input Signal

SmartX MF and MS

Flowrite 599 Series. Technical Bulletin. 1/2 to 2-Inch Valve (2-Way & 3-Way) and Actuator Assembly Selection. Document No.

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

Accessories/Kits Ball Valve Bracket Kit (includes bracket, mounting screws, shaft and handle)

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

Type A - PICV Actuator Series

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

Powers Controls RL 147 Positioning Relay

MS Application. Features. Proportional Valve Actuator General Instructions

CP (Vdc) CP (Milliamp) CP (Slidewire)

I ntroduction. VA-7450 Electronic Terminal Unit Valve Actuator. Features and Benefits

599 Series 2-Way Ball Valves

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

NV Direct Coupled Globe Valve Actuator

Transcription:

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control Document No. 55-8P25 EA 599-4 EA379R Description The Flowrite EA 599 Series SKD Electronic Valve Actuator requires a 24 Vac supply and receives a to Vdc or a 4 to 2 ma control signal to proportionally control a valve. This actuator is designed to work with Flowrite VF 599 Series valve and Siemens Building Technologies, Inc. standard valves with a 3/4-inch (2 mm) stroke. Features Direct-coupled installation requires no special tools or adjustments Visual and electronic stroke indication Application Die-cast aluminum housing anual override Spring return to fail safe position Automatic stroke calibration aintenance-free These electronic actuators are designed to be used with Flowrite VF 599 Series valves and Siemens Building Technologies standard valves with a 3/4-inch (2 mm) stroke in liquid service and steam service applications. Product Number SKD62U (Actuator Prefix Code 274)

Document Number 55-8P25 SKD Electronic Valve Actuator 24 Vac Proportional Control Warning/Caution Notations WARNING CAUTION Personal injury/loss of life may occur if a procedure is not performed as specified. Equipment damage, or loss of data may occur if the user does not follow procedure as specified. Specifications Power supply Operating voltage 24 Vac ± 2% Frequency 5/6 Hz Power consumption 7 VA Control signals Control input () Voltage aximum Impedance to Vdc or 4 to 2 ma (DIP switch selectable) to Vdc K ohms 4 to 2 ma; 24 ohm Control input (Z) Resistance to ohms Voltage to.6v Control output (U) Voltage to Vdc Load Impedance >5 ohm Current 4 to 2 ma Load impedance < 5 ohms Function Nominal stroke 3/4-inch (2 mm) Run time with control operation (full stroke) Power stroke, to %; % to % 3 seconds Spring return stroke, to % 5 seconds Nominal Force Stroke Force NC and 3-way upper % 225 lbs. ( N) NO and 3-way by-pass % 258 lbs. (5 N) Agency Certification UL approval UL873 C-UL Certified to Canadian standard C22.2 No. 24-93 CE conformity per the EC directive 89/336/EEC Low voltage directive 73/23/EEC Ambient conditions Ambient temperature 5 F to 22 F (-5 C to 5 C) edia temperature 4 F to 284 F (- C to 4 C) Housing NEA Rating NEA (interior only) See Accessories. iscellaneous Dimensions See Figure 9 Conduit opening /2-inch NPS Weight 7.5 lbs. (3.4 kg) Page 2

SKD Electronic Valve Actuator 24 Vac Proportional Control Document Number 55-8P25 Accessories NOTE: Installation instructions are included with each accessory. ASC.6 Auxiliary switch. EA7R 5 4 3 Figure. Auxiliary Switch. Sends a signal to indicate the valve is in the % stroke position. Switching point is fixed at the % stroke position. Switching capacity Lowest recommended current 24 Vac 4A resistive 2A inductive ma 599-47 Packing heating element. EA393R Figure 2. Packing Heating Element. EA87R 2 4 6 8 % Figure 3. Remote Setting Unit. Allows stem to move freely in valves controlling fluids at temperatures below 32 F ( C). Reduces ice crystal formation on the stem which may damage the packing. Operating Voltage Heating Output 2 W 24 Vac FZA2. Remote setting unit. Potentiometer for manual control or remote setting of minimum positions of controlled devices. Suitable for flush panel mounting only. Control Input to Ohms 599-7 Weather Shield. See Service Kits for replacement UV resistant cable ties. EA853R Figure 4. Weather Shield. Page 3

Document Number 55-8P25 SKD Electronic Valve Actuator 24 Vac Proportional Control Service Kits The only field serviceable part is the circuit board. Circuit board replacement 4-668-5748-8 Plastic wiring compartment cover 4-4 5634-8 anual Override Kit for SKD 4-268 554-8 Ultraviolet (UV) resistant cable ties (pkg. of ) 538-996 WARNING: This product contains a spring under high compression. Do not attempt to disassemble the actuator. SKD Details ;EA389R ;Figure 5. SKD Details. Legend Pressure cylinder 2 Piston 3 Oscillating pump 4 Return spring 5 Bypass valve 6 Valve stem retainer 7 anual override knob 8 Position indicator Page 4

SKD Electronic Valve Actuator 24 Vac Proportional Control Document Number 55-8P25 Operation The actuator accepts a to Vdc or a 4 to 2 ma control signal. The actuator mounted on a valve, produces a stroke proportional to the input signal. When power is turned off or in the event of a power failure, the actuator spring returns the valve to its normal position. Vdc 4 2 ma STROKE EA86R A B EA439R Figure 7. Figure 6. 3/4 in. (2mm) EA387R Figure 8. Valve Stem Travel Indication. ounting and Installation Not allowed with the Weather Shield EA92R Not allowed in any circumstance Figure 9. Acceptable ounting Positions. The vertical position is the recommended position for mounting. Other positions are allowed. When using the Weather Shield for NEA 3R rating, the vertical position is required. See Weather Shield installation instructions and Figure 9. Allow four inches ( mm) around the sides and back of the actuator and eight inches (2 mm) above and to the front of the actuator. See dimensions in Figure 9. Detailed installation instructions for field mounting are shipped with the actuator. Page 5

Document Number 55-8P25 SKD Electronic Valve Actuator 24 Vac Proportional Control Start-up Stroke Calibration Check the wiring for proper connections. NOTE: The valve body assembly determines the complete assembly action. To determine the stroke positions % and % in the valve, calibration is required when the valve/actuator are commissioned for the first time. The actuator must be mechanically connected to a valve and must have a 24 Vac power supply. The calibration procedure can be repeated as often as necessary. CAUTION: Before starting calibration, be sure the manual adjuster is set to Automatic to register the actual values. There is a slot on the printed circuit boards of the the actuators. To initiate the calibration procedure, the contacts inside this slot must be short-circuited, for example, with a screwdriver (See Figure ). Automatic calibration proceeds as follows (See Figure ): Actuator runs to the stroke position (), green LED flashes. Actuator then runs to the stroke position (2), green LED flashes. easured values are stored in the EPRO. The actuator now moves to the position defined by control signal or Z (3), and the green LED now glows steadily (normal operation). Throughout this procedure, output U is inactive; meaning, the values only represent actual positions when the green LED stops flashing and remains on continuously. EA66R EA65R Figure. Stroke % 2 3 % Figure. y Table. LED Status. LED Display Function Action ON Normal Operation Automatic operation Green Wait for calibration to be Flashing Stroke calibration In Progress completed (LED stops flashing) Faulty stroke calibration - Check mounting ON - Restart stroke calibration (by short-circuiting calibration slot) Red Internal Error - Replace electronics Flashing Inner valve jammed Check the valve OFF No power supply -Check mains Faulty electronics -Replace electronics Page 6

SKD Electronic Valve Actuator 24 Vac Proportional Control Document Number 55-8P25 Start-up continued Override Control The override control input (Z) has three modes of operation: No Function G Stroke G % Hmax Override with... G Stroke G % U Z Hmin Z-Contact not Wired Valve Stroke Follows Control Signal Actuator Fully Extended U Z R % 5 9 R [] Z-Contact Connected to Via Resistor R Linear or Equal-Percentage Characteristic Starting Position at 5 / End Position at 9 -Input has No Effect Actuator Fully Retracted G Stroke G Stroke G % Vmax G % Vmax EA64R U Z % Z-Contact Connected Directly to G -Input has No Effect U Z % Z-Contact Connected Directly to G -Input has No Effect The Z-modes have a "direct acting" factory setting. Page 7

Document Number 55-8P25 SKD Electronic Valve Actuator 24 Vac Proportional Control Start-up continued Connection Terminals Stroke Calibration G G U Z AC 24V G 5/6Hz... V G 4... 2mA Chm Status Calib. Calib. Status Green Red OK Calib. Error Valve Jam LED Status Indication DIP Switches Functions See Below EA68R 2 Figure 2. SKD Electronic Features. DIP Switches (Left to right) Selection of Control Signal 2 Selection of Flow Characteristic ON 4 to 2 ma odified* OFF Factory Setting to Vdc Default *Changing the default setting will modify an equal percentage valve to a linear flow characteristic. When set to default, the flow characteristic is determined by the valve body. Page 8

SKD Electronic Valve Actuator 24 Vac Proportional Control Document Number 55-8P25 Start-up, continued Normally Closed Valve Normally Open Valve Three Way Valve Actuator pressure cylinder moves: Outward ( to ): Valve opens. Inward ( to ): Valve closes. Actuator pressure cylinder moves: Outward ( to ): Valve closes. Inward ( to ): Valve opens. Actuator pressure cylinder moves Outward ( to ): Valve opens between port NC and C. Inward ( to ): Valve opens between ports NO and C. The measuring voltage at terminal U provides valve stem position feedback to an indicating instrument or building automation system. anual Operation >3x36 << AUTO >> EA8R << AN >> << AUTO >> Figure 3. The anual Setting Knob in anual and Automatic Position. - Turn the manual setting knob clockwise for manual operation. - A red indicator becomes visible as you begin to crank. Each complete revolution (36 ) is equal to 3/32-inch (2.5 mm) stroke. - If a signal is sent to the actuator while it is in manual operation, the actuator will move but the control will not be accurate. - The valve cannot be commanded to its % position while in manual operation. Automatic operation For automatic operation the manual override knob must be in the fully closed position. Turn the manual override knob counterclockwise until the red indicator disappears. Page 9

AC 24 V Document Number 55-8P25 SKD Electronic Valve Actuator 24 Vac Proportional Control Wiring Wiring Diagram Do not use autotransformers. Use earth ground isolating step-down Class 2 power supplies. Determine supply transformer rating by summing total VA of all actuators used. The maximum rating for Class 2 step-down transformer is VA. Since SKD62U actuator requires 2 VA, a maximum of four actuators can be powered by one transformer (8% of transformer VA). Operating more than four SKD62U actuators requires additional transformers or separate VA power supplies. The position output signal U will switch from to Vdc to 4 to 2 ma when a 4 to 2 ma input signal is selected and used on the terminal. B G (SP) F B 2 3 G B N G G U Z EA74R G G (SN) B Sensor F Temperature Limiter N Controller Actuator Figure 4. Connecting Terminals. 24 Vac G System Potential (SP) G System Neutral (SN) Control input to Vdc or 4 to 2 ma (DIP switch selectable) easuring neutral U Position indication to Vdc or 4 to 2 ma, See Table 2. Z Override control Table 2. Receiving Impedance Actuator input signal low (<5 Ohm) high (>k Ohm) to Vdc to 2 ma to Vdc 4 to 2 ma 4 to 2 ma 2 to Vdc Page

SKD Electronic Valve Actuator 24 Vac Proportional Control Document Number 55-8P25 Wiring Diagrams, continued 3 G (SP) EA85R 4 C 5 24V~ 2W GO (SN) 2 EA84R EA83R2 Z Figure 5. Auxiliary Switch ASC.6. Figure 6. Packing Heating Element 599-47. Figure 7. Remote Setting Unit FZA2.. Troubleshooting Check that the wires are connected correctly and attached securely. Check for adequate power supply. Check that the actuator is set for automatic operation. See the Start-Up section. Dimensions -/4 (285) 8-3/6 (224) 4-3/6 (22) 4-3/6 (22) 2-9/6 (65) 9-3/8 (232) 4-/2 (4) -5/6 (49) 2-7/8 (327) 3/4 (9) EA854R 5 (26) Figure 8. Dimensions of 599-7 Weather Shield in Inches (illimeters). Page

Document Number 55-8P25 SKD Electronic Valve Actuator 24 Vac Proportional Control Dimensions, Continued NOTE: The top knockout position should be used when installing the Weather Shield. 4-3/4 (2) 2-/2 (64) 4-/8 (5) KNOCKOUT FOR STANDARD /2" CONDUIT CONNECTOR Ø5 (27) 5-5/8 (43) -3/6 (3) 4-7/8 (23) EA385R 2-5/8 (66) Ø-3/4 (44) Ø2-9/6 (65) Figure 9. Dimensions of SKD Actuator. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Flowrite is a trademark of Other product or company names mentioned herein may be the trademarks of their respective owners. 23 Deerfield Parkway Buffalo Grove, IL 689-453 U.S.A. our feedback is important to us. If you have comments about this document, please send them to technical.editor@siemens.com Document No. 55-8P25 Printed in the U.S.A. Page 2