Q-TRIX R50 & Q-HEX MINI INSTLLTION INSTRUCTION Q-TRIX R50 Q-HEX Mini Cautions The Main Secondary wiring is intended for shallow burial - Less than 6 inches (152mm) unless Q-Tran direct burial Q-Wire and Q-Clik are used " To purchase additional Q-Wire and CUTION Q-Clik Connectors visit our website (q-tran.com) or contact your local Q-Tran representative. The Power Unit is not to be used within 10 Feet (3.05 m) of a pool or spa. *ssemble part Q-TRIX only with part Q-HEX 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.ll rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com
Q-TRIX (R) Remote ox Details C D E F G H I J : : C: D: E: F: G: 1/2 NPT Threaded Cap 1/4-20 olts (3x) 1/2 NPT THREDED POST (For mounting a path light or ccent light fixture) FIELD WRITING TRCK (For unit locating) Housing GSKET HIGH IMPCT Door 1/4-20 Nuts K H: I: Nut Holder HIGH IMPCT Housing J: K: DRILL GUIDE - Drill and attach fittings (Q-Click 1/2 & 3/4 fittings permitted) Planting Stakes (Secures unit to the ground 3x) Q-HEX mini (Power Supply) Details C D E F G : : C: D: E: F: G: HIGH IMPCT Top Cap Resetable secondary CIRCUIT REKER with water tight boot Secondary wires Label Sec. WIRE COMPRTMENT (wire leads held in an individual Secure Tube) HIGH IMPCT OTTOM COVER Primary wires 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.ll rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com 1
Q-TRIX R50 - MTRIX Q-TRIX-R50 with Q-HEX-MINI 1 2 1 1 KO 1x x x x x Do not use KO (Knock Outs)marked with X when installing the Q-HEX MINI with the Q-TRIX R50. Q-HEX Mini installation (Q-Hex Mini & Q-Trix R50 combination) 1/2 KO 3x 3/4 KO 3x ottom 2 Q-TRIX R50 WITHOUT Q-HEX MINI 2 3 This unit can be used as a splice box 3 WLL MOUNT PLTE Q-TRIX WLL Installation (Optional wall plate sold seperately) Q-TRIX R-50 (LOD DISTRIUTION REMOTE SPLICE OX) SPLICE J-OX (Use water tight connectors Ex: Q-Clik MST/NPT connectors. Connectors sold seperately) Q-TRIX Direct urial Design configuration (1) Feed from Q-TRIX 160 unit to Q-TRIX R50 (2) Feed from Q-TRIX 160 unit to Q-TRIX R50 (3) Q-TRIX 160 to 160 to R-50 remote boxes Pathway example: 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.ll rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com 2
Q-TRIX R50, Q-HEX mini 1 EXCVTE (DIG HOLE) Dig x x 12" hole that Q-Trix R50 housing will fit inside as shown. 2 KNOCKOUT OR DRILL HOLES Drill knock out holes for Wire Connectors.Example: Q-Clik connectors. X X X X 12" 3/4" NPT Connector Optional 1/2" MST KO TOP VIEW (Hole Length & Width) SIDE VIEW (Hole Depth) *Use only these Drill sizes for side Holes: 7/8 for 1/2 KO and 1 1/8 for 3/4 KO NOTE: Drill only TOP KO holes of Q-Trix R50 housing,or useonly outer Knockouts on the bottom when installing Q-HEX mini power supply unit. Maximum 3x Q-Clik connectors can be installed at the bottom or 3x on either side or the Housing. 3xconnectors of 1/2 or 3/4 on each side. Use 3/4 connector on bottom. (Q-CLIK SOLD SEPRTELY) 3 INSTLL CONNECTORS & STKES 4 Install SStakes (3X) NOTE: Use Q-wire & Q-Clik for water tight installation (Q-Wire & Q-Clik sold seperately) CLIK RING MCHINE SCREW THRED (MST) SE Install connectors Q-Clik NPT ottom or Q-Clik MST Sides NUT White Green 6" lack Yellow 6" RUN FIELD WIRES TO HOUSING lue CUTION See Front Page Field wires *Pull maximum of 6 of primary and Secondary wires into Q-Trix R50 housing. WING NUT RUER INSERT WSHER 1 WSHER 2 HOUSING WLL 5 LOWER Q-HEX mini INTO Q-TRIX R50 Q-Hex Mini install orientation: lue Yellow 6 PREPRE Q-HEX mini WIRE Understand the following highlighted wires NOTE: Strip ends for wire nut connection 6" Wire Corner White lack Green 6" Primary wiring side C INPUT Transformer Primary wires Green - Ground White - Neutral lack - Tap 1 OUTPUT Transformer Secondary wires 12 v / 24v common *Circuit breaker reaker head corner Field wires DC LED DRIVER INPUT Primary wires Vac IN Vac IN LED DRIVER DC OUT PUT Secondary wires Positive + Negative - *Secondary Circuit breaker factory installed is optional requested when placeing order 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.ll rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com 3
Q-TRIX R50, Q-HEX mini 7 CONNECT WIRES Use Water tight silicone filled wire nuts to connect all wires in the Q-Trix Unit ( wire nuts not provided ). Use Q-Trix R-50 remote box for additional wire splicing or power distribution. ( dditional Q-Trix R-50 remote box sold seperately ). C DC Connect INPUT load to Primary white / black and green wire Connect INPUT load to Primary lue wires VC Connect OUTPUT load to secondary 12v or 24v wire and common wire. Connect OUTPUT load to secondary +Yellow / - lack wire *Some of connected Luminaire load shall not exeed output load of Q-HEX 8 PREPRE UNIT TO E URIED C Installation Displayed CUTION See Front Page Cover Housing and tightened (3x) 1/4-20 stainless steel Door olts by alternating bolt turns. Tighten bolts at a Maximum torque of 25 lbs. WireTies (10x) Use provided wire ties to manage excess Tuck connected wire nuts in the corner as shown C Installation displayed 9 URY Q-TRIX WITH 2 TOP EXPOSED 12" SIDE VIEW (Hole Depth) TOP VIEW (Hole Length & Width) 10 OPTIONS Q-TRIX WLL Plate (Wall plate sold separately) Remove cap and expose 1/2 NPT threads and knockout center K.O to install Path light, or accent light. Important; squeeze silicone into threads before mounting fixture. (See Diagram C) Q-TRIX R50 SPLICE OX Q-TRIX FIXTURE MOUNT 1/2 NPT threaded Door allows fixture to be mounted on Q-Trix unit. Q-Trix R50 Housing can be used for wire splicing and power distribution(q-clik 1/2 & 3/4 NPT or MST connectors can be used) llows unit to be surface mounted. Indoor or Outdoor. Install wall plate with Stainless Steel Pan Phillips Machine Screw (4x) 1/4-20 x 3/8" and Hex Lag olt Screw (2x) 1/4 x 1.5" ( Screws are included ) Diagram OPTIONL FIXTURE INSTLLTION ON Q-TRIX UNIT Diagram Diagram C 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.ll rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com 4
Q-TRIX R-50 DIRECT URIL SPLICE OX Q-Trix R-50 junction box allows for multiple load distribution from Q-Trix 160 or 200 unit and can stand alone as a Direct urial junction box. ury Q-Trix R-50with 2 top exposed OPTIONL FIXTURE INSTLLTION ON Q-TRIX R-50 JUNCTION OX TOP VIEW (Hole Length & Width) ury Q-TrixR-50 in a 10x10x12 inch dugged up hole. 4 SIDE VIEW (Hole Depth) 12" Remove cap and expose 1/2 NPT threads and knockoutcenter K.O to install Path Light,or ccent Light. Important; squeeze silicone into threads before mounting fixture. (See Diagram & ) Diagram Diagram Q-Trix R-50 FIXTURE MOUNT 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.ll rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com 5
Q-TRIX-R50-WP Wall Mount Plate Installation INSTRUCTIONS 1 Cut diagram on the left to trace the location of the Lag olt for wall mounting. PRTS INCLUDED (4X) 1/4-20 x 3/8" Pan Phillips Machine Screw (2X) 1/4 x 1.5" Hex Lag olt *Lag olts must be mounted to wall studs. LRGE PLTE SMLL PLTE Full Scale Template: Cut Template to use on wall 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.ll rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com 6
2 Screw large and small plates to the bottom of the Q-Trix-R50 with Machine Screws. Pan Phillips Machine Screw (4X) 1/4-20 x 3/8" LRGE PLTE SMLL PLTE 3 Install Lag olt screw into wall where the unit will reside. Then slide the key hole unit onto the screw. Lastly install final Lag olt at the bottom of the plate Hex Lag olt (2X) 1/4 x 1.5" WLL WLL 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.ll rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com 7