Sensors & Accessories for Automatic Doors

Similar documents
NET-DS System. Automatic Sliding Door Operator. NABCO's Advanced Technology to enhance comfort and safe operations of automatic doors.

SLIDER AUTOMATIC DOOR TECHNICAL DATA THE ENERGY SAVING TECHNOLOGY OF SLIDER ENERGY SAVING

SLIDING DOOR OPERATOR INSTRUCTION MANUAL

TOWA SEIDEN INDUSTRIAL CO., LTD.

REVOLVING DOOR AUTOMATIC TWO-WING REVOLVING DOOR

Direct Coupled Damper Actuator Model MY6050A1001

Setup and Programming Manual

HIGH SPEED DOORS roll-up folding

access

Turn OFF all power to the Automatic Door if a Safety System is not working.

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Pressure Transmitters

Direct Coupled Damper Actuator Model MY9050A1001

record STA 21 record system 20 technologies for light to medium-heavy applications

GT 710. Surface-Mounted, Low Energy, ADA*, Fire-Rated Swing Door Operator PRODUCT FEATURES

EntreMatic EMSL USER S MANUAL

Safety Control HR1S-AC. Safety Relay HR1S-AC

More than lifts worldwide with GMV technology HOME LIFTY MRL.

Tourniket. The all round revolving door. Door Systems

Light grids and light curtains LCA

Differential Pressure Transmitter

PAS(PARKING AID SYSTEM)

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

NF-Series Operation Instructions

record STA 21 record system 20 technologies for light to medium-heavy applications

EvoDrive AUTOMATIC INTERNAL DOOR

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

EvoDrive AUTOMATIC INTERNAL DOOR

Inductive Proximity Sensor

PY600AC Sliding Gate Opener User Manual

HATO 120 / 200 SECTIONAL DOOR OPERATOR USER S MANUAL HATO 120/200 SECTIONAL DOOR OPERATOR USER S MANUAL

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

BARRY BARRIER GATE AUTOMATION

Pneumatic & Cushion Tire/ Electric-powered Models

Inverter Resistance Welder/Horizontal Pressure Head NRW-IN8400A/NA-184 Now Available

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

BODYGUARD III-C USER S GUIDE

International hotel project references

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

More than lifts worldwide with GMV technology GOODS LIFT PASSENGER & VEHICLE LIFT GLP-VLT.

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

PANcharge1k Battery Charger User's Manual

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Selection Guide Automotive Relays

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Sectional and Tilting Door Opener

LED Reference for Circuit Board

MODEL 422 Submersible Pump Controller

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

Remote Engine Starter System I User s Information Manual

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

Gate & Door Controller with LCD and Intelligent Technology

Max. Lifting Capacity : 55t 3.0m

19mm Thickness. Phone: Fax: Web:

BEA Pedestrian. Sensor solutions for revolving doors

Gilgen FD 20 swing door drive unit

Rapid doors.

DX50 PNEUMATIC TIRE FORKLIFT. The Forklift With Proven Ability. 15,400 18,000 LBS. CAPACITY DIESEL

USER MANUAL MPS 1-5KW SERIES

HD 200. Automatic Sliding Door Operator

EX Series. Electric Actuators for Ball and Butterfly Valves

Photoelectric Sensors 55 Series

RS ACTUATO RS ACTUATO

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

LINCE 300/400/600. User s and Intaller s manual

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

tons Class 1 - sit-down type

MINI EXCAVATOR RANGE BROCHURE

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET

Lumitester PD-20 Control Kit

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

SA1W: Water Detection Sensors

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

RP Instruction Manual

CAUTION-ELECTRICALLY OPERATED PRODUCT:

Examination tables lamps chairs cabinets trolleys accessories. Examination room furniture

home lift Italian Excellence and Design

SRT1000 Series THERMAL FLOWMETER

EOS4. Safety level: Type 4 SIL 3 SILCL 3 PL e Cat. 4

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

EX Series. Electric Actuators for Ball and Butterfly Valves

! Contact our sales office regarding a delivery date or a price since this is a special model. Auto switch D-M9 series mountable

EOS 2. Safety level: Type 2 SIL 2 SILCL 2 PL d Cat. 2

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Pneumatic Drive Type Drill Bit Breakage Detection Sensor. DFM3 Series. The World's First!! Pneumatic-Drive Type. Catalog / Instruction Manual US.PAT.

U17-3 KUBOTA ZERO TAIL SWING COMPACT EXCAVATOR

2-Color Display High-Precision Digital Pressure Switch

Comfort. Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

QUADSCAN User s Guide Door Mounted Presence sensor

PARKING AID SYSTEM GENERAL 1. SPECIFICATIONS

R3 Roller Garage Door Opener

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

X3-45 commuter coach. the choice is yours

EVS RP6020. Instruction Manual

Transcription:

NABCO Automatic Doors Sensors & Accessories for Automatic Doors SENSOR 06 Vol.

For comfort and safe pedestrian flow solutions, NABCO's sensors enhance the performance of automatic doors. Importance of sensors Sensors are the important elements of automatic doors. Sensors are called the eyes and ears of automatic doors, as they constantly examine the conditions of surrounding areas and send them to the brain of automatic doors. The performance of the sensor significantly enhances the function of automatic doors. Even in the high-performance automatic doors, improper sensors may hamper the performance of the entire system. Therefore, the selection of the sensor is important in achieving the full performance of automatic doors. NABCO sensors NABCO is the automatic door brand produced by Nabtesco Corporation, which produced the first automatic door in Japan, and has Japan's largest market share. We have been striving to manufacture the superior products by continuous R & D activities. Our extensive experience ensures the supply of high-quality and high-performance sensors for automatic doors. With a wide range of high-quality products, our sensors are receiving the reputation as the best solution for automatic doors around the world.

NET System Automatic door units with this logotype support the network system using CAN communication. NABCO is the first door brand that adopted the internationally standardized network technology using CAN communication into automatic door systems. Information networking among not only automatic door units but also optional devices, such as sensors and electric locks, has improved security and reliability, and we propose the best maintenance plan using the maintenance data that we have accumulated and managed. Eco Due to shorter opening time of the door that pedestrians pass through, this function reduces the influx of wind and dust and enhances air conditioning efficiency. Eco Mode Door opens normally for approaching pedestrians and closes earlier in response to pedestrians moving away. Door opens Door closes earlier Symbols The sensor should be selected in consideration of the type of the automatic door and the site condition. Please select the best sensor for the site to enhance the safety and performance. Near-infrared sensor Detects persons and objects by the reflection of active infrared sensor with new technology. Ultrasonic sensor Detects persons and objects by the reflection of ultrasonic wave and can be used as a support sensor. Photoelectric beam sensor Is applicable to wide range of usage from an activation sensor to a support sensor. Program switch Allows easy selection of the most suitable door operation. Touch sensor Operates by placing the hand or object near the sticker. Electric lock Secures an entrance with low operation sound. Sensor for unique door design Can cover doorway area of circular and folding door by memorizing doors movement. Emergency operating system Operates the door at a power failure or when it receives an emergency signal. Colors The standard of each color depends on the product. CL W DG BK SUS Clear White Dark gray Black Stainless Steel HL M S BZ Hairline finishing Mirror Silver Bronze Actual colors may be different from this brochure. types Exposed Sensors are mounted on the transom. Body of sensor is observable. Embedded Sensors are embedded in the ceiling, wall, or mullion. Body of sensor is partly observable.

Best suited NABCO sensor can be selected by function, Products for each mounting place 3 Others 4 Transom mount Ceiling mount MS-(N)0 M Search is-n4000 isearch 7 3 Transom embedded / Transom bottom- mount MS-(N)0 M Search 6 MS-(N)03 M Search 6 NZ- ULTRASONIC SENSOR 8 Suitable for circular and folding doors as support sensor 4 Mullion / Jamb Accessories NH-0 Side Beam Sensor 8 PL-U Pulley Lock 9 EOS Emergency Operating System 9 Locking mechanism functions as a belt pulley To operate door in emergency condition NP-0B / NP-0LB Photoelectric Beam Sensor 8 SKD- Electric Lock 9 Adcanced Program Switch 0 Compact electric deadbolt lock APS-N0 APS-N 3

PageExposed Embedded Motion mounting type, and design from a wide variety of products. Sensor list of NABCO automatic door Type Object height (reference only) position Presence Height(m) Width(m) Depth(m) 3 4 mmax. 3 4 mmax. 3 mmax. at mounting hight of Transom mount MS-(N)0 M Search 4.0.9.8. Transom embedded Transom bottommount Transom bottommount MS-(N)0 M Search 4.0.9.8 MS-(N)03 M Search 4.0.9.8. 6. 6 Ceiling mount is-n4000 isearch 4.0..3.4 7 NH-0 Side Beam Sensor 0.. φ0.04 8 Support Sensor NP-0B Beam Sensor NP-0LB Beam Sensor.0 8.0 8 8 NZ- Ultrasonic Sensor. φ. φ. 8 Notes concerning sensor detection area for NABCO automatic door The detection areas referenced in this brochure are measured by Nabtesco, and their charts are expressed only as an image. They are not the actual value of the detection areas because the measurements may vary by the installation environment, the detected objects and the adjustment. Clothes, floor material as well as sensitivity adjustment may affect the detection area. Please measure and confirm the actual detection area after the adjustment.

Transom mount MS-(N)0 M Search Advanced automatic door sensor to enhance safety and comfort Exposed Eco MS-N0 MS-0 Motion / Presence Detection (Near Infrared reflection method) height.0m4.0m W.9m D.8m ( height.m) S BZ W BK M SUS Power supply / Power consumption Output rating Features 0mA or less at VDC NET-DS connector (CAN Communication) 4VAC to 00VAC (0 / 60Hz) VA or less (at 00VAC) VDC to 00VDC 0mA or less (at VDC) No-voltage relay contact, Semiconductor relay output Full color LED display, Replacement time display Self-diagnosis function, Eco mode Anti-snow / insects mode, Anti-vibration mode Independent 7 spots, Doorway area monitoring for unique door design, Contact-free touch sensor function, Measure against insertion mode 6 6 40 Mass : 60g (MS-N0) 80g (MS-0) (mm) height shows the height of where sensor is mounted. height 3 4 6 G H I A B C D E F height.0m.m.m 3.0m 3.m A 00 0 0 0 70 B 390 430 480 80 670 C 60 70 80 980,0 D 960 00 00 440,680 E 300 430 60 90,70 F 600 80 070 490,90 G 0 30 30 840,0 H 00 30 630 360 3,690 I 640 900 3300 3960 4,60 (mm) 4.0m 00 770 30 90 90 330 40 40 80 The above values are obtained when the area adjuster is set at zero degree. Old types (an example) Doorway area monitoring for unique door design No detection area on door way M Search covers doorway by memorizing door's movement. e.g. Circular sliding door Contact-free touch sensor function : How to work When door is closed, When a passenger places his / the detection area is limited. her hand near the touch-area, the door starts to open. 3 Once the door opens, the detection area is extended as wide as standard mode. For MS-N0 / N0 / N03iS-N4000 4 After the passenger goes out of the wider detection area, the door starts to close and the detection area returns to be limited again. As contact-free touch sensor by near-infrared reflection method, unlike a mechanical touch switch, it may detect an object at other positions than near touch sticker. For MS-N0 / N0 / N03

Transom embedded / Transom bottom- mount MS-(N)0 M Search Embedded Transom embedded type which keeps transom flat and its aesthetic Eco BK 4 40. Mass : 7g (MS-N0) 300g (MS-0) height Power supply / Power consumption Output rating Features (mm) height shows the height of where sensor is mounted. height 3 4 6 G H I MS-N0 Motion / Presence Detection (Near Infrared reflection method) 0mA or less at VDC NET-DS connector (CAN Communication) A B C D E F.0m4.0m W.9m D.8m ( height.m) MS-0 4VAC to 00VAC (0 / 60Hz) VA or less (at 00VAC) VDC to 00VDC 0mA or less (at VDC) No-voltage relay contact, Semiconductor relay output Full color LED display, Replacement time display Self-diagnosis function, Eco mode Anti-snow / insects mode, Anti-vibration mode Independent 7 spots, Doorway area monitoring for unique door design, Contact-free touch sensor function, Measure against insertion mode height.0m.m.m 3.0m 3.m A 00 0 0 0 70 B 390 430 480 80 670 C 60 70 80 980,0 D 960 00 00 440,680 E 300 430 60 90,70 F 600 80 070 490,90 G 0 30 30 840,0 H 00 30 630 360 3,690 I 640 900 3300 3960 4,60 (mm) 4.0m 00 770 30 90 90 330 40 40 80 The above values are obtained when the area adjuster is set at zero degree. MS-(N)03 M Search Exposed Transom bottom-mount type which is applicable to the limited space Eco MS-N03 MS-03 Motion / Presence Detection (Near Infrared reflection method) height.0m4.0m W.9m D.8m ( height.m) S BZ W BK M SUS Power supply / Power consumption Output rating Features 0mA or less at VDC NET-DS connector (CAN Communication) 4VAC to 00VAC (0 / 60Hz) VA or less (at 00VAC) VDC to 00VDC 0mA or less (at VDC) No-voltage relay contact, Semiconductor relay output Full color LED display, Replacement time display Self-diagnosis function, Eco mode Anti-snow / insects mode, Anti-vibration mode Independent 7 spots, Doorway area monitoring for unique door design, Contact-free touch sensor function, Measure against insertion mode 3 96 44 Mass : 80g (MS-N03) 300g (MS-03) (mm) height shows the height of where sensor is mounted. height 3 4 6 G H I A B C D E F height.0m.m.m 3.0m 3.m A 00 0 0 0 70 B 390 430 480 80 670 C 60 70 80 980,0 D 960 00 00 440,680 E 300 430 60 90,70 F 600 80 070 490,90 G 0 30 30 840,0 H 00 30 630 360 3,690 I 640 900 3300 3960 4,60 (mm) 4.0m 00 770 30 90 90 330 40 40 80 The above values are obtained when the area adjuster is set at zero degree.

Ceiling mount is-n4000 isearch Embedded Advanced ceiling mount sensor equipped with doorway monitoring function Eco S hole 8-30mm Ceiling thickness-mm Mass : 330g is-n4000 isearch (mm) height Power voltage Current consumption Output ratings Motion / Presence Detection (Near Infrared reflection method) Max. 4.0m Max. W.m x D.3m [ height.4m] VDC 0% 0mA or less NET-DS connector height 3 4 6 G H I A B C D E F height (m) Depth (m) Width (m) A B C D E F G H I.0 9 7 460 660 870,090 860,630,080.4 0 330 0 790,040,30,040,90,00 3.0 3. 4.0 40 40 690 98,300,63,80,430 3,090 60 47 800,4,,90,490,840 3,60 8 4 90,30,730,80,700 3,40 4,0 7

Support Sensor (Beam and Ultrasonic Sensor) NH-0 Side Beam Sensor A mullion-mount sensor, utilizing a Near-Infrared ray Exposed Useful for a narrow passage or an entrance where a store curtain is hanged, preventing unnecessary doors activation. 3 9 70 Mass : 0g Detection distance Power voltage Current consumption Output ratings BK Presence / Motion Detection (Near Infrared method) 0. to.m VDC 0% 0mA or less NH-0 Side Beam Sensor Open collector, 0VDC 0.A (resistance load) NP-0B / NP-0LB Beam Sensor Simple and reliable Embedded The doors open when a photoelectric beam between a transmitter and a receiver in mullions or fixed frames is interrupted by pedestrians or objects. The door remains open as long as interrupted. Detection range NP-0B Motion / Presence Detection (Near Infrared reflection method) Between photocells 0.9m to.0m To be used with Beam Sensor controller 4 NP-0LB Between photocells.0m to 8.0m.6 CL Mass : 0g (NP-0B) 30g (NP-0LB) (mm) 090 0000 NZ- Ultrasonic Sensor NZ-R NZ-R NZ-U (A=4) NZ-H (A=40) 0000 Support sensor monitoring doorway with three dimensional detection area height Power voltage Current consumption Output ratings 0 8 3 M6 Installed in the transom NZ-U A 4 (mm) Model NZ-R NZ-U NZ-H Exposed Embedded Ultrasonic reflection still object detection method NZ-R, NZ-U : Max..m NZ-H : Max. 3.0m NZ-R, NZ-U : Max..mNZ-H : Max..3m 00VAC 0% 4.0VA or less NZ-H NZ-R S BZ NZ- Ultrasonic Sensor No-voltage relay contact a, 0VDC/0.A (resistance load) -M4 0 40 Mass : 0g / 60g / 6g 900 Detection area 400 (mm) D=00 D=00 D=300 NZ-U NZ-H S BZ HL M D at FL+.0m

Accessories SKD- Electric Lock Compact electric deadbolt lock Low noise and low vibration Fail-safe type and Fail-secure type Answer-back function (SKD-US / UES, SKD-LS) Lock / unlock signal and full close signal are output. Manual release function (SKD-UE / UES, SKD-L / LS) Available in case of emergency (Wire / handle is necessary.) Locking condition Manual release Hold-locking force Operating time Durability SKD-U SKD-US Fail safe (Unlock at power off) SKD-UE SKD-UES 000N or more Available Lock:.0s or less / 0.7s or less, Unlock: 0.6s or less / 0.3s or less Lock: 3.0 to 0.7s, Unlock: 0.7s to 0.3s (for NET-DS Lock controller) Over,000,000 times SKD-L SKD-LS Fail secure (Lock at power off) (.7) 6 SDK-U / US Lead wire 67 38 MassSKD-U / SKD-US,000g SKD-L / SKD-LS,00g Lock controller is exclusively required. PL-U Pulley Lock Locking mechanism functions as a belt pulley EOS Emergency Operating System Operates door in emergency condition R-N0 EOS Controller Battery Unit The electrical locking and unlocking devices with the built-in electromagnetic lock within the idler pulley, which seizes the driving belt secured to door panel Simple replacement : The installation dimensions are nearly same as those of standard idler pulley. Locking condition Hold-locking force Fail safe (Unlock at power off) Approx. 800N Replaced with idler pulley PL-U Pulley Lock 6 Operates sliding door at power failure or in an emergency condition with EOS controller and battery unit. Power voltage Emergency power voltage Ambient tempereature Operation at emergency Emergency input Battery capacity Battery charging time R-N0 EOS Controller 7.4 EOS Emergency Operating System 00V AC0V, 0 / 60Hz, A Ni-Cd rechargeable battery -0 to 0 Panic-open or panic-close No-voltage contact input / 4VDC input 30 times or 30 minutes operation Approx. hours 370 33. 64 6.3 43. 33. Clearance for tension adjustment is about 4 9 48.6 Mass : 00g Battery Unit 30 73. 37 8.6 6.3 43. 33. Mass,300g To be used with Pulley Lock controller. 48. Mass : 600g 9

APS-N0 Advanced Program Switch User-friendly advanced program switch for automatic sliding door Color LCD offers excellent visibility for switching the automatic door mode and changing the parameter set values. Installer can check information related to malfunctioning parts and operation history, which makes maintenance and troubleshooting easier. Two types of access codes are programmable to provide different levels of pass to different users. 88 6. 3 Operation Mode Parameter Change Error and Operation History 88 8 Mass : 0g Applicable controller Power voltage Current consumption Security method NET-DS controller VDC0 Max 80mAVDC Passcode APS-N0 APS-N Advanced Program Switch Allows selection of the optimal door operation DS Transformer Ideal for NABCO operators The operation mode of automatic sliding door can be changed easily. Two types of access codes are programmable to provide different levels of pass to different users. Applicable controller Power voltage Current consumption Security method NET-DS controller VDC0 Max 7mAVDC Passcode APS-N Compact and reliable Perfectly suitable for NABCO automatic door Input Output 66 0VAC, 0 / 60Hz 00VAC,.0A DS Down Transformer 8 67 6 03 80.8 980.8 8 0. 00 8 64 0 480.8 3 Mass70g Mass :,00g

Cautions for safe operation when using automatic doors. Don't halt!. Don't run in! Do not stop on the door way. Do not rush through the door. Do not cross the door diagonally. 3. Don't play near automatic door! 4. Don't lean on the automatic door! Do not stand talking near the door. Do not let children play near the door. Do not lean on the door, the screen or the wall nearby nor step on them.. Accompany your children! 6. Pay attention to the door! For small children, grownups should take their hands when passing through the door. Extra care should be taken for the handicapped and blind persons in going through the door. Be careful so that fingers will not be caught in the leading or rear edge of the door. Accessibility Innovations Company For further details, please contact: Address Phone Fax : JA Kyosai Bldg., 7-9, Hirakawacho -chome, Chiyoda-ku, Tokyo, 0-0093, Japan : +8(0)3-3-7 : +8(0)3-3-73 https://nabco.nabtesco.com/en/ ISO900 / ISO400 Certified All specifications herein are subject to change without notice