Allfluid pressure switches 20D to ATEX

Similar documents
Hydraulic pressure switch 20D Acc. to ATEX

18D according to ATEX

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

Weight (kg) Dimension No. G1/4 Exhausting None 0,2 1 T F2BG *1) Interface Exhausting None 0,4 3 T10-N10-D2BN

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

97105 Inline. Ordering information. Technical data. Accessories See page 5

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

97100 NAMUR. Technical data

Operating pressure (bar) kv factor (m 3 /h) *3)

High pressure valves. 80 to 350 bar

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Our policy is one of continued research and development. We therefore reserve the right

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

C D J K N N/UK /02. Our policy is one of continued research and development. We therefore reserve the right

24010, 3/2 Direct solenoid actuated poppet valve

LAP4, LAP8. Pneumatic linear drive sizes 4 and 8

Our policy is one of continued research and development. We therefore reserve the right

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

HERION SERIES Indirect solenoid actuated soft seal

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Compact pressure switch Model PCS

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

Compact differential pressure switch Models DC, DCC

SBM TECHNOLOGY Cooling / Air Recovery Valve

M/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted

Compact temperature switch Model TCS

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

Mini pressure switch Stainless steel switch enclosure Model PXS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Mini temperature switch Stainless steel switch enclosure Model TXS

M/44000/M. LINTRA Rodless cylinders Magnetic piston Double acting Ø 25 to 40 mm

LRA/8000/M/EX, LRA/8000/EX, ISO cylinder Magnetic & Non-magnetic piston, double acting

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

N/** поставка оборудования для подготовки воздуха

Pressure switch and Thermostat Type CAS

25000, 4/2 Direct solenoid actuated poppet valves

Solenoid Valve Island Type 3965

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

2/2 Pressure operated valves

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

PRESSURE SENSING AND CONTROL PRESSURE SENSING AND CONTROL

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Differential-Pressure Flow Meter

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

short name: 3WL.IG* technical product sheet created :57 1/6 3-way ball valve F/F PN 63 with pneumatic actuator hard anodized aluminum

Ex Pressostat EXPK 944/947/953. Applications. Features

store.norgren.com 18D Pneumatic Rapid delivery order today Models Accessories 1 30 bar For further information

Pressure and temperature controls, Type CAS

VP23. 3-way proportional pressure control valve Directly-controlled seat valve with μp-driven pressure control G 1/4 to G 3/4 Nominal diameter 8/16

PSC-B. Pressure sensing and control. Herion 18D Pneumatic pressure switches (diaphragm type), - PSC-2

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Rod thermostats (without immersion tube)

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

PSC-2. Herion 18D Pneumatic pressure switches (diaphragm type) Vac psi. Pressure sensing and control

Nugget 40, V08 series

Limit Switch Type 4747

LPRA/182000/M Double acting profile cylinders Ø mm

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

RPPN3 - RPPN7 Industrial pressure switch

Explosion-protected surface-mounting Thermostat ATH-Ex Series

MAKING MODERN LIVING POSSIBLE. Pressure switch BCP. Technical brochure

Description. Positive safety relays

Pressure Control, Differential Pressure Control, Type RT

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

SBM TECHNOLOGY PET Blow Valve Block

RDN4 - RDN8 Differential pressure switch

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

LPRA/182000/M, ISO cylinder Magnetic piston, double acting

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

Load disconnect switch Series 8146/5-V11

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

PHOENIX CONTACT - 01/2008

Pressostats and thermostats CAS

Our policy is one of continued research and development. We therefore reserve the right to amend,

V03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

Control Buttons / Switches for Panel Mounting Series 8003

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

Chapter 2: Directional Control Valves

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Room thermostats type series TRM

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

T84T - Excelon Plus Modular System 3/2 shut-off valve

RM/900/M Heavy duty cylinders Ø 1 1/4... 4

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Flap-Type Flow Meter Prall

RM/57200/M, RT/57200/M

Sensor boxes SRBE Key features and product range overview

Transcription:

-1... 63 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector M20 x 1,5 Robust metal housing in weather-resisting version Technical data Medium: For neutral, non-inflammable gases and fluids Operation: Softseal piston Stainless steel bellow Fluid connection: G1/2 Operating pressure range: -1... 63 bar Temperature: Fluid Ambient -10*... +75 C -10*... +75 C *Please contact our technical service for use below +2 C Repeatability: ±1% of final value (depending on regulating pressure) Microswitch With gold plated contacts Degree of protection (acc. to DIN 40050): IP65 Mounting position: Optional Shock-/vibrations (to avoid if possible): 4 g max. (sinusoidal) / 5 Hz max. Sealing: < 10-7 mbar l s -1 Pulsations: Not permitted Switching cycles: 20/min. max. Materials: Housing: aluminium diecast : stainless steel Sealing: stainless steel-bellows Ordering information See page 2 Alternative variants Examination test acc. to pressure equipment directive 79/23/EC (DIN 3394-3/DIN EN 1854) on request p 2 3 1 Switching function: Microswitch SPDT (commutator) Terminals 1-3: Contacts close on rising pressure Terminals 1-2: Contacts open on rising pressure N/UK 5.11.231.01

Operating pressure range for 184 (fixed switching pressure difference) Type Operating pressure range *1) Over pressure *2) typical value Pressure sensor material Fluid port Dimensions see page pvu min. to pvo max. lower range upper range bar (VDI 3283 ) bar bar bar bar 184 01 15-1...0 10 0,20 0,23 1,4404 B 4 184 02 15-1...1 10 0,20 0,25 1,4404 B 4 184 04 15-1...2,5 10 0, 0,26 1,4404 B 4 184 11 15 0,05...1 10 0,16 0,18 1,4404 B 4 184 15 0...1,6 10 0,16 0,20 1,4404 B 4 184 14 15 0,5...4 20 0,50 0,55 1,4404 B 4 184 15 15 0,5...6 20 0,60 0,70 1,4404 B 4 184 16 15 0,5...10 20 0,70 0,90 1,4404 B 4 184 17 15 1...16 50 1,00 1,40 1,4404 F 4 184 18 15 1...25 50 1,30 1,80 1,4404 F 4 184 19 15 5...63 150 2,00 5,00 1,4404 H 4 Operating pressure range for 185 (adjustable switching pressure difference) Type Operating pressure range *1) pvu min. to pvo max. (VDI 3283 ) bar Over pressure *2) typical value lower range upper range minimum maximum Pressure sensor material Fluid port bar 185 01 15-1... 0 10 0,19 0,25 0,80 1.4404 B G1/2 4 185 02 15-1... 1 10 0,20 0,30 1,00 1.4404 B G1/2 4 185 04 15-1... 2,5 10 0,20 0,28 2,50 1.4404 B G1/2 4 185 11 15 0,05...1 10 0,16 0,18 0,80 1.4404 B G1/2 4 185 15 0...1,6 10 0,10 0,16 1,00 1.4404 B G1/2 4 185 13 15 0,1...2,5 10 0,18 0, 2,00 1.4404 B G1/2 4 185 14 15 0,5...4 20 0,50 0,60 2,50 1.4404 B G1/2 4 185 15 15 0,5...6 20 0,60 0,70 5,00 1.4404 B G1/2 4 185 16 15 0,5...10 20 0,70 0,90 8,00 1.4404 B G1/2 4 185 17 15 1...16 50 1,60 1,90,00 1.4404 F G1/2 4 185 18 15 1...25 50 1,60 2,20 20,00 1.4404 F G1/2 4 185 19 15 5...63 150 2,00 5,00 20,00 1.4404 H G1/2 4 *1) Bezugsdruck ist der atmosphärische Luftdruck *2) Auch kurzzeitige Druckspitzen während des Betriebes dürfen diesen Wert nicht überschreiten. Eine betriebsmäßige Ausnutzung des Grenzwertes ist nicht zulässig. Der Grenzwert entspricht dem max. Prüfdruck. F = Faltenbalg pvu = Schaltpunkt bei fallendem Druck pvo = Schaltpunkt bei steigendem Druck Dimensions see page Options selector 18 15 Substitute fixed 4 adjustable 5 Ordering information ATEX pressure switch with fixed switching pressure difference, switching point at 4 bar, connection, Electrical connection M20 x 1,5, medium: water, Quote: 1841515 Operating pressure range (bar) Substitute -1... 0 01-1... 1 02-1... 2,5 04 0,05... 1 11 0... 1,6 0,1... 2,5 13 0,5... 4 14 0,5... 6 15 0,5... 10 16 1... 16 17 1... 25 18 5... 63 19 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. The system designer is warned to consider the failure modes of all N/UK 5.11.231.02 Konstruktionsänderungen vorbehalten Our policy is one of continued research and development. We therefore reserve the right to amend, 7/06

Accessories Brackets Surge damper Pressure port reducing nipplel Page 5 Page 5 Page 5 0574772 (steel) 0553258 (stainless steel G1/4) 0553831 (G1/2 1//2 NPT) 0553908 (stainless steel) 0574773 (brass/steel) G1/4) 0550083 (G1/4 G1/2) 0551894 (stainless steel G1/2 ) 0574764 (G1/4 G3/8) 0574765 (G1/4 1/4 NPT) Switching capacity Commutator with gold plated contacts Load level Current Load type Umin Max. permanent current Imax [A] at U [V] Contact life type [V] 30 48 60 5 250 M x1 Standard *3) AC ohmic 5 5 5 5 5 10 7 switching cycles (z.b. contractors, AC inductive, solenoids) cos ϕ 0,7 3 3 3 3 3 DC ohmic 5 1,2 0,8 0,4 DC inductive, 3 0,5 0,35 0,05 L/R 10 ms Minor *4) AC ohmic 5 *6) 0,34 0,2 0,17 0,08 0,04 10 7 switching cycles (z.b. electronic DC inductive, circuits) L/R 10 ms 5 *6) 0,1 0,01 Reference number: 30/min, Reference temperature: +30 C Spark quenching with diode with DC and inductive load: I max = 1,5 x I max of table I min = 1 (ma) Creepage and air paths correspond to insulation group B according to VDE Reg. 0110 (except contact clearance of microswitch). *3) Gold-plating not required as it would decay. Max. perm. in-rush current (appr. 30 ms) I AC = max. 15 A *4) Gold-plating required (will not decay). *6) Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions. Spark quenching with DC voltage 1. Diode D in parallel to inductive load. Observance of correct polarity (positive pole to cathode). Dimensioning specifications for quenching diode: Rated voltage at diode: UD 1,4 x Us Rated current at diode: I N ILast Selection of a quick switching diode (recovery time trr 200 [ms]). 2. RC link in parallel to load in parallel to switching contact. Suited for DC and AC voltage. Dimensioning principles: R in 0,2 x RLoad in C in [µf] ILoad in [A] + (AC) p U S - (AC) R Last I Last D R C N/UK 5.11.231.03

25 20 H Allfluid pressure switches 20D Dimensions (mm) 115,5 19 5,8 104 25 20 H 81 70 5 1 44 19 1 M4 x 10 deep Connector M20 x 1,5 acc. to EEx e (ATEX), Nickel plated brass for cabel Ø 5 to 8 mm (Type: 0588819) ca. 27 M 20 x 1,5 6 ø 5-8 combinations Operating pressure range code type Substitute 15 01 B 02 B 04 B 11 B B 13 B 14 B 15 B 16 B 17 F 18 F 19 H Style F+H H B type B 75 42 32 F 37 32 41 H 53 37 32 Style B ø B ø B N/UK 5.11.231.04 Our policy is one of continued research and development. We therefore reserve the right to amend, 7/06

Brackets (2 brackets and 4 screws) Steel Type: 0574772 Stainl. steel 1.4301 (AISI 304) Type: 0553908 141 9 104 14 3 5,8 118 Surge damper Stainless steel 1.4301 (AISI 304) Type: 0553258 Brass/steel Type: 0574773 Stainless steel 1.4301 (AISI 304) Type: 0551894 46 27 45 ø 21,5 34 5 20 Pressure port/reducing nipple G1/2 I to G1/2 NPT A G1/4 A to G1/2 A Stainless steel 1.4305 Stainless steel 1.4305 (AISI 303/304 S) (AISI 303/304 S) Type: 0553831 Type: 0550083 G1/4 A to G3/8 Steel Type: 0574764 G1/4 A to 1/4 NPT Brass Type: 0574765 G1/4 27 1/2 NPT,5,5 G 3/8 ø21,5 13 36 1/4 NPT ø 20 6,5 30 N/UK 5.11.231.05