FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions

Similar documents
INSTALLATION AND OPERATION MANUAL MOUNTING ELECTRICAL

Installation Manual for the SHURflo LCB - G Pump Controller

INDUSTRIAL PUMP 8000 SERIES

INDUSTRIAL PUMP 8000 SERIES

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Rev: Flow Max 115V AC Fluid Pump

RV PRODUCT DATA SHEET

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

SHURFLO AQUA KING II STANDARD 3.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

Flojet Rewrites the Book on Small Pump Control

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

Model &

Operator s Safety and Service Manual

SHURflo Close-Coupled Centrifugal Pumps

M-3025CB-AV Fuel Pump

REPAIR SEALS AND OPTIONS

8000 / 10,000 / 12,000

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Installation, Operation, Repair and Parts Manual

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

M-1115S Series Fuel Pump

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Instruction Manual. Johnson Ultra Ballast Pump. Johnson Pumps

Troubleshooting WARNING

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

The table below shows brix pump ratios currently available. The brix pump is shipped with the 3-way sanitizing valve.

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Close-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models

SUBMERSIBLE SUMP PUMPS

SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

SHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

P-200 Plastic Utility Pump for Petroleum Products

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL

GARDEN HOSE UTILITY PUMP

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

SUBMERSIBLE SUMP PUMPS

Self-Priming Centrifugal Pumps Refer to pump manual for General Operating and Safety Instructions.

G8 Portable Fuel Transfer Pump Owner s Manual

08 general Purpose Pumps

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

1600 PSI ELECTRIC PRESSURE WASHER

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Marine Pumps & Accessories

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

PowerFLO 5800/5900 Series

MODEL 900 IMPELLER-TYPE FLOW METER

IMPORTANT SAFETY INSTRUCTIONS

07 Oil Change & Diesel Transfer Pumps

MODEL 200 MULTI-JET FLOW METER

# and # FAST Fuel System Kits

Hydraulic Immediate Need Power Pack

OWNER S MANUAL. Model: FS-ATV-15 ( ) (15 Gallon Lawn & Garden/ATV Sprayer) Technical Specifications. Assembly Instructions. General Information

Model 6275RC 50% Duty Cycle Compressor

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

100 Gallon Skid Sprayer

Specifications Information and Repair Parts Manual , , , &

Oil Pump Models L 5016, L 5116 & L 5132

MODEL 200 MULTI-JET FLOW METER

ProFlo FatBoy

12V PORTABLE PRESSURE PUMP

07 Oil Change & Diesel Transfer Pumps

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

PARTS AND INSTALLATION MANUAL

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

QUALITY MISTING PUMPS

Users Manual Certified Series Direct Drive Pump 1-7 LPM

SUNC3000 / Item #40885

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

SHURflo Pedestal-Mount Centrifugal Pumps

"Engineered to Ride, Built to Last "

SUPER PUMP OUT SYSTEM

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

Installation & Operating Manual

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

OWNER S MANUAL. Model: PLATINUM55 ( ) (55 Gallon Deluxe Lawn & Garden Spot Sprayer)

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

QUALITY MISTING PUMPS

MODEL CJ-200E CoilJet Portable HVAC Coil Cleaning System

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

SERVICE MANUAL. PVR15-Manifold Series Pump. J Design Series INSTALLATION. Ordering Code PVR15 - _ RM - _ - - J

B14 AAA FINE FINISH SERIES PUMP OUTFIT

B14 AAA FINE FINISH SERIES PUMP OUTFIT

Installation & Operating Manual

Pump Specifications 250 Series Submersible Sump / Effluent Pump

AEROMOTIVE Part # & Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Transcription:

FLEX VANE IMPELLER MODEL 3000-XXX Replacement Parts Kit Instructions WARNING:Do not pump flammable liquids! Model 3000 pumps (Buna impeller) are suitable for non-potable water, automotive oil, automatic transmission fluid, and low-viscosity gear lubricants. CAUTION: Always disconnect electrical power and relieve outlet pressure prior to initiating any repairs. Wear proper clothing, gloves, and eye wear when working on pumps used with chemical solutions. Pump should be thoroughly flushed in a responsible manner prior to disassembly. 1. Remove the four # 8 ¾" screws retaining the cover. Remove cover, front wear plate, and o-ring. 2. Pull impeller out of pump housing and remove rear wear plate. Clean the impeller cavity. 3. If the shaft seal is not leaking, replacement may not be necessary, continue at step: 8. For seal replacement, remove the two 10 32 1¾" screws and pull pump housing off the motor shaft. Leave the slinger on the motor shaft. 4. Using a small screw driver remove the retainer clip and shaft seal from the back of pump housing. 5. Clean seal contact area on the motor shaft. If the motor shaft has excessive wear (from seal) do not repair. 6. Install new shaft seal with seal lip inserted into the pump housing and the flat of the seal facing out. Press in retainer clip so the tangs bottom out on shoulder within housing. 7. Grease motor shaft/seal area. Reinstall the pump housing onto motor shaft and align to the threaded holes. Install # 10 screws (2) and hand-tighten. Max. torque 25 in./lb. 8. Install rear wear plate into impeller cavity, and generously grease wear plate and cavity walls. 9. Align the impeller/shaft flats. Push in impeller with a twist so the blades are bent over in the same direction. 10. Apply grease to top of the impeller. Place o-ring into groove. Install wear plate and front cover. Install # 8 screws (4) and tighten until snug. Max. torque 15 in./lb. NOTE:Do not run pump dry! Pre-prime pump if necessary. Dry running for more than 20 seconds will damage pump. 911-485 Rev. A 1/98 Page: 1 of 2

RETURN POLICY SHURflo Flex Vane impeller replacement kits are non-warrantable items. Kits are only returnable when the original factory packaging has not been opened, and not more than one year has elapsed since its date of manufacture. R ISO Certified Facility SHURflo 12650 Westminster Ave. Santa Ana, CA 92706-2100 (800) 854-3218 (714) 554-7709 FAX (714) 554-4721 Shipping/UPS: 12650 Westminster Ave. Garden Grove, CA 92843 a WICOR Company SHURflo reserves the right to update specifications, prices, or make substitutions. SHURflo East 52748 Park Six Court Elkhart, IN 46514-5427 ((800) 762-8094 (219) 262-0478 FAX (219) 264-2169 1998 Printed in USA SHURflo Ltd. Unit 5 Sterling Park Gatwick Road, Crawley West Sussex, RH10 2QT United Kingdom +44 1293 424000 FAX +44 1293 421880 911-485 Rev. A 1/98 Page: 2 of 2

WATER WOLF FLEX VANE IMPELLER PUMP INSTALLATION AND OPERATION MANUAL CAUTION: Do not pump flammable liquids with Flex Vane Impeller Pumps! MOUNTING The pump can be positioned above the liquid tank if needed, as it is capable of a 7.5 ft. [2.3M] vertical prime (with water). Consider a location that allows easy access if maintenance is required. The pump should not be located in an area less than one cubic foot unless adequate ventilation is provided. Excessive heat may trigger the integral thermal breaker and interrupt operation. When the motor temperature drops, the breaker will automatically reset and the pump will start. NOTE: Protect motor from rain or washdown; it is enclosed but not waterproof. The pump may be mounted in any position. If mounting the pump vertically, the pump head should be in the down position so that in the unlikely event of a leak, water will not enter the motor. Use # 8 hardware to fasten the pump. Choose a solid surface that will not amplify pump operation. The mounting feet are intended to isolate the pump from the mounting surface; over-tightening, flattening, or use of oversized screws will reduce the ability to isolate vibration/noise. ELECTRICAL The pump should be on a dedicated (individual) circuit, protected by the specified fuse indicated on the motor label. An "ON/OFF" switch rated at or above 15 amps is recommended (3000-000 & 3000-010 only). The switch must interrupt current flow on the positive (+ red) lead. Marine applications should use U/L approved marine duty (ignition protected) switches and wiring standards. The black lead (-) must be grounded to a "known ground." The ground wire must be the same size (gauge/mm 2 ) as the positive wire. Wire size (gauge/mm 2 ) is based on the distance from the power source to the pump. The minimum recommended size wire is # 14 gauge [2.5 Mm 2 ]. Lengths of 20-50 ft. [6-15M] use # 12 gauge [4 M m2 ]. The total current draw on the circuit must not exceed 15 amps. If the pump is used in conjunction with other components, overload current protection (fuse or circuit breaker) and wire size must be for the total amp requirement of all devices on the circuit. PLUMBING SHURflo recommends 1/2" [13mm] I.D. flexible high pressure tubing to both ports. Ideally, the pump ports/strainer should not be connected to plastic or rigid pipe. The pump's normal oscillation may transmit through rigid plumbing causing noise, and possibly loosen or crack components. Make sure washer in inlet fitting is clean and in good condition. Vacuum leaks on the inlet side will cause a "no prime" condition. Installation of the SHURflo Raw Water Strainer (P/N 252-3300) (50 mesh) on the inlet side is recommended to prevent foreign debris from entering the pump. Failure due to debris is not covered under the SHURflo limited warranty. OPERATION NOTE: DO NOT RUN PUMP DRY. Pump depends on liquid being pumped for lubrication. If pump does not prime within 20 seconds, recheck installation and plumbing. Failure due to dry running is not covered under the SHURflo limited warranty. To help priming, pour one ounce [30 ml] of liquid in inlet port. On older pumps that do not prime, replace the impeller with SHURflo P/N 94-120-00 impeller/seal kit. 911-479 Rev. C 10/98 Page: 1 of 2

Pump should prime within 20 seconds. If not, turn off the pump and do the following: a) Disconnect inlet hose at pump. Pour one ounce [30 ml] of liquid into inlet port. b) Check washers in inlet hose and make sure inlet is airtight. c) Make sure inlet and discharge line are free of kinks and restrictions. d) Make sure pump is less than 7.5 feet [2.3 M] above the liquid source. Pump may deliver 3¾ G.P.M. [14 L.P.M] when discharge is not restricted. As discharge is restricted, pressure increases, and flow decreases. CAUTION: Do Not operate pump at a discharge pressure of more than 12 psi [.8 bar] or discharge lift of more than 28 ft [8.5M]. Motor will exceed the normal safe operating temperature and can heat to 180 o 190 o F [82 o 88 o C]. Motor is rated for intermittent duty only. WINTERIZING If water is allowed to freeze in the system, serious damage to the plumbing and the pump may occur. The best guarantee against damage is to drain the water system. Failures of this type will void the warranty. SPECIFICATIONS Model Number: Application/Design: Duty Cycle: Open Flow Rate: Maximum Pressure: Maximum Liquid Temps: Current Draw: Motor Design: Fuse: Approvals: Impeller Material: Self-Prime: Ports: Weight: 3000-000 Std.... 3000-010 (C ) 3000-300 Premium... 3000-310 (C ) (w/ ON\OFF sw., 8 leads w/ clips, fittings, and ¼" oil probe) General purpose, transfer pump Intermittent Duty (20 min. per hour) 3.75 G.P.M. [14 L.P.M.] 12 psi [.8 bar] 33 120 F [1 48 C] 5.5 Amps max. at 12 psi [.8 bar] 12 VDC Permanent Magnet; Thermally Protected, Automatic Reset Refer to motor label for recommended fuse 3000-000 Std: U/L Marine & C-U/L.... 3000-010 (C ) 3000-300 Premium: N/A.... 3000-310 (C ) Buna 7.5 ft. [2.3 M] vertical lift with water 3 / 4 " garden hose thread (O.D.) 3 / 8 NPT ports (I.D.) 3.3 lb. [1.5 Kg] Std.... 3.8 lb. [1.7 Kg] Premium. LIMITED WARRANTY SHURflo warrants its Water Wolf Flex Vane impeller pump to be free from material and workmanship defects under normal use and service for a period of one (1) year from the date of manufacture or one (1) year of use with proof of purchase, not to exceed two (2) years in any event. The limited warranty will not apply to pumps that were run dry, misapplied, or are incompatible with components not manufactured by SHURflo. Pump failure due to foreign debris or chemical incompatibility is not covered under the terms of this limited warranty. Water Wolf pumps are not intended for commercial use. SHURflo will not warrant any pump that is physically damaged or altered outside the SHURflo factory. Warranty claims may be resolved by an authorized dealer service center or by a SHURflo service center. Returns are to be shipped with charges pre-paid. Package all returns carefully. SHURflo will not be responsible for freight damage incurred during shipping to a service center. For complete limited warranty information consult Service Bulletin # 1050. R ISO Certified Facility SHURflo 12650 Westminster Ave. Santa Ana, CA 92706-2100 (800) 854-3218 (714) 554-7709 FAX (714) 554-4721 Shipping/UPS: 12650 Westminster Ave. Garden Grove, CA 92843 a WICOR Company SHURflo reserves the right to update specifications, prices, or make substitutions. SHURflo East 52748 Park Six Court Elkhart, IN 46514-5427 ((800) 762-8094 (219) 262-0478 FAX (219) 264-2169 1998 Printed in USA SHURflo Ltd. Unit 5 Sterling Park Gatwick Road, Crawley West Sussex, RH10 2QT United Kingdom +44 1293 424000 FAX +44 1293 421880 911-479 Rev. C 10/98 Page: 2 of 2

3000 Series Replacement Kits Model Number Complete Pump Assembly Drive / Impeller Assembly Motor 3000-050 94-122-00 94-120-00 11-214-01 3000-350 94-122-00 94-120-00 11-214-01 SHURflo reserves the right to update specifications, prices, or make substitutions 2009 SHURflo, LLC All Rights Reserved