DOUBLE CHECK VALVES SERIES PRODUCT CODES OPERATION MEDIUM HAZARD RATING. 20mm - 50mm FEATURES APPLICATION SPECIFICATION STATEMENT DESCRIPTION

Similar documents
4P-300 4V-500 CONTINUOUS PRESSURE THERMOPLASTIC DUAL. PRINCIPLE (U & Z Flow) DUAL CHECK VALVE. PRINCIPLE (Stn.Steel) REDUCED PRESSURE

MADE IN THE USA BACKFLOW PREVENTERS

Installed on the pump suction, CRISPIN Foot Valves prevent the

THE DEFENDER 4D-200 SERIES

Backflow Preventers TABLE OF CONTENTS

Installation Operation Maintenance

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

MAG- Backflow Preventers. MAG-BEECO Backflow Preventers deliver the highest level of performance, reliability, ease of use and save time and money.

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

Cash-Flo. Operation & Maintenance Manual. BackFLOW PREVENTERS. A Division of the Reliance Worldwide Corporation

BACKFLOW PREVENTION CATALOG

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

Description. Functions. Technical data. Applications. Tests. Level control float valve, enabling the control of the filling level.

HD Series. Pilot-Operated Regulating Valves. HD Series features & benefits

AMERICAN FLOW CONTROL 3-16 SERIES 2100 RESILIENT SEATED CHECK VALVE

PRESSURE REDUCING VALVES

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

NON RETURN BRASS FLANGED AGA GAS APPROVED

w w w. w a t t s. c o m

PRESSURE REDUCING CONTROL VALVE

Valve Selection. 1. Function and service considerations

FM 3. FM 3 with Bypass. Materials and Specifications. Fire Service Meter with Bypass Sizes 3, 4, 6, 8, 10. Features

Ref ALL POSITIONS CAST IRON CHECK VALVE PN16. Model/Ref:

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

PRESSURE CONTROL VALVES SABS 198

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

VALFONTA PRESSURE REGULATOR WITHOUT AUXILIARY ENERGY EXCESS PRESSURE VALVE (PRESSURE RELIEF VALVE) MODEL S1 MAIN CHARACTERISTICS

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

Swing Check Valves - Series 41

Backflow Preventers & Accessories

INSTALLATION & MAINTENANCE MODEL mm

BACKFLOW PREVENTION CATALOG

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

Introduction. Resilient Seat Butterfly Valves. Valves D-207.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

We Accept the Following Truths to be Self- Evident. 1. A Backflow Incident Is Foreseeable, Not A Question Of If, But Rather When

DIMENSIONS (approximate)

G lobe Style Check Valves are designed to close before the

flowit by Fig. FTBGW-20 Bronze Gate Valve, Non-Rising Stem BS 5154 PN20 Material Specifications Dimensions (mm)

Cast Iron Valves. Product Information. It s all at Albion

VALFONTA SELF-ACTING PRESSURE REDUCING VALVE M1

ZONE CONTROLE / 2-WAY

AVFI Float Valves (A805)

HYDRAULIC CONTROL VALVES

Wafer Silent Check Valves

Backflow Prevention. Quick Reference Guide

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

Crane. UNI-CHEK High Performance Check Valves

F low L ine 72/73 Wafer & Lug Style Sizes 2-24

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

Deep Well Pump Control Valve

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

J & S Valve GATE VALVE AWWA C509. Resilient Seated Solid Wedge Size: 2-12

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

PRESSURE REDUCING VALVE

Grooved Butterfly Valves

PRESSURE REDUCING VALVE

Section - L. Antipollution devices

346 REF. 346 NO POLLUTION CHECK VALVE EA 577 NOREPOL PN16 NO POLLUTION CHECK VALVE EA 577 NOREPOL PN16

RESILIENT SEATED BUTTERFLY VALVES. Howell Valve & Automation. Toll Free: Howellvalve.com

PRESSURE REDUCING VALVE

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

Irrigation Series. Backflow Preventers, Water Pressure Regulators, and Water Control Products for Irrigation Applications

TEL: Version: KW2

CHAMPION WAFER CHECK VALVES SIZE RANGE 2" 72" ASME CLASS MATERIALS: IRON CARBON STEEL STAINLESS STEEL ALUMINUM BRONZE ALLOY 20 MONEL NICKEL

Dura Gas Butterfly Valve

DN 50 to 300 Flanges GN10/16-10 C C Max Pressure : 16 Bars Specifications : Cast iron disc All positions Low head loss

SEries 41 check valve installation, operation & maintenance manual

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section.

2-20 (50mm-500mm) SERIES 30/31 Wafer/Lug RESILIENT SEATED BUTTERFLY VALVES. The High Performance Company

APCO CVS-250/250A SWING CHECK VALVES

Suction Guide & Flo-Trex Valve Series

Concentric butterfly valves

GRUNDFOS DATA BOOKLET TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D. In-line circulator pumps. 50 Hz. Lenntech

G lobe Style Check Valves are designed to close before the

PDC Elastomer Lined Series 27 Butterfly Valve 2" thru 36" for 125/150 lb. Flanging

Series 77S-M1 ( 1 4" 3") Cast Iron Wye-pattern Strainers

BEECO FLOW CONTROL

Irrigation Solutions. Backflow Preventers, Water Pressure Regulators, and Water Control Products for Irrigation Applications.

HELYON PRESSURE REDUCING VALVE MODEL M1

Valves & Flow Control Components Valves & Flow Control Components

Cover Page - Butterfly Valves Ordering Information Design Features, 2 to 12 Design Features, 2 to 12 (continued)

Lead-free valves for potable water systems. Rev 02/17

Non Return Valves.

AIR/VACUUM VALVE AND OPTIONAL ANTI-SLAM DEVICE SPECIFICATION

Transportation Valves

Product Data Sheet. Recordall Fire Series Assemblies (FSAA) Cold Water Meter & Strainer with Disc Bypass DESCRIPTION

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

SECTION MISCELLANEOUS VALVES

SECTION VALVES PART 1 -GENERAL

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

Fabri-Valve. C67 Bi-Directional Knife Gate Valve

AMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016


Transcription:

PRODUCT CODES DCV20DO DCV25DO DCV32DO DCV40DO DCV50DO DCV20 DCV25 DCV32 DCV40 DCV50 20mm Double Check Valve - Device Only 25mm Double Check Valve - Device Only 32mm Double Check Valve - Device Only 40mm Double Check Valve - Device Only 50mm Double Check Valve - Device Only 20mm Double Check Valve Complete with Fittings Kit 25mm Double Check Valve Complete with Fittings Kit 32mm Double Check Valve Complete with Fittings Kit 40mm Double Check Valve Complete with Fittings Kit 50mm Double Check Valve Complete with Fittings Kit 20mm - 50mm FEATURES Corrosion resistant Designed for easy and quick in line maintenance and testing Replaceable seats Low head loss Interchangeable poppet and spring Maximum working pressure of 1200 kpa Operating temperature range of 1 C to 80 C Approved to AS 2845-1 DESCRIPTION situations. OPERATION During normal flow conditions, the two check valves are held open, supplying water downstream. Each check valve is designed to maintain a minimum of 7 kpa across the valve during normal operation. Should the downstream pressure increase to within 7 kpa of supply pressure, both check valves will close as double protection against a backflow condition. APPLICATION The AVG 40-100 Series Double Check Valve provides protection to the potable water supply from contamination in medium hazard applications such as industrial, commercial and medical equipment. SPECIFICATION STATEMENT AVG 40-100 Series Double Check Valves shall be installed as per Australian Standards AS 3500-1, including resilient seated isolation valves and strainer The backflow prevention device shall be manufactured to AS 2845-1 and be annually tested and maintained as recommended in AS 3500-1. The valve shall be adequately supported with approved supports and clipping as required. The device features two independent spring-loaded check valves. These are housed in a single bronze body. They may be installed horizontally or vertically. 16 Tel: 1800 AVG AUS (284 287) www.avg.net.au

FLOWCHARTS 20mm - 50mm MATERIALS Body and covers Springs Poppets Seat Discs Fasteners Check Seats Bronze Glass-filled Celcon Silicone rubber Glass-filled Noryl TECHNICAL DATA Threaded inlet & outlet Female BSP Min. working pressure 220 kpa Max. working pressure 1200 kpa Max. temperature 60 C DIMENSIONS AND WEIGHT www.avg.net.au Tel: 1800 AVG AUS (284 287) 17

PRODUCT CODES DCV65FLGDO DCV80FLGDO DCV100FLGDO DCV65FLG DCV80FLG DCV100FLG 65mm Double Check Valve - Device Only FLG Table E 80mm Double Check Valve - Device Only FLG Table E 100mm Double Check Valve - Device Only FLG Table E 65mm Double Check Valve Flanged Complete Table E 80mm Double Check Valve Flanged Complete Table E 100mm Double Check Valve Flanged Complete Table E 65mm - 100mm FEATURES Corrosion resistant Designed for easy and quick in line maintenance and testing Replaceable seats Low head loss Interchangeable poppet and spring Maximum working pressure of 1200 kpa Operating temperature range of 1 C to 60 C Approved to AS 2845-1 DESCRIPTION situations. OPERATION During normal flow conditions, the two check valves are held open, supplying water downstream. Each check valve is designed to maintain a minimum of 7 kpa across the valve during normal operation. Should the downstream pressure increase to within 7 kpa of supply pressure, both check valves will close as double protection against a backflow condition. APPLICATION The AVG 40-100 Series Double Check Valve provides protection to the potable water supply from contamination in medium hazard applications such as industrial, commercial and medical equipment. SPECIFICATION STATEMENT situations. The device features two independent spring-loaded check valves. These are housed in a corrosion resistant coated ductile iron body. They may be installed horizontally or vertically. The device features two independent spring-loaded check valves. These are housed in a corrosion resistant coated ductile iron body. They may be installed horizontally or vertically. 18 Tel: 1800 AVG AUS (284 287) www.avg.net.au

FLOWCHARTS 65mm - 100mm MATERIALS Body and covers Springs C.V. Seat Discs Fasteners Check Seats External finish Ductile iron EPDM Bronze Epoxy Coat TECHNICAL DATA Flanged inlet and outlet Table E Min. working pressure 220 kpa Max. working pressure 1200 kpa Max. temperature 60 C DIMENSIONS AND WEIGHT www.avg.net.au Tel: 1800 AVG AUS (284 287) 19

PRODUCT CODES DCV150FLGDO DCV150FLG 150mm Double Check Valve - Device Only FLG Table E 150mm Double Check Valve Flanged Complete Table E 150mm - 250mm FEATURES Corrosion resistant Designed for easy and quick in line maintenance and testing Replaceable seats Low head loss Interchangeable poppet and spring Maximum working pressure of 1200 kpa Operating temperature range of 1 C to 60 C Approved to AS 2845-1 DESCRIPTION situations. OPERATION During normal flow conditions, the two check valves are held open, supplying water downstream. Each check valve is designed to maintain a minimum of 7 kpa across the valve during normal operation. Should the downstream pressure increase to within 7 kpa of supply pressure, both check valves will close as double protection against a backflow condition. APPLICATION The AVG 40-100 Series Double Check Valve provides protection to the potable water supply from contamination in medium hazard applications such as industrial, commercial and medical equipment. SPECIFICATION STATEMENT situations. The device features two independent spring-loaded check valves. These are housed in a corrosion resistant coated ductile iron body. They may be installed horizontally or vertically. The device features two independent spring-loaded check valves. These are housed in a corrosion resistant coated ductile iron body. They may be installed horizontally or vertically. 20 Tel: 1800 AVG AUS (284 287) www.avg.net.au

FLOWCHARTS 150mm - 250mm MATERIALS Body and covers Springs C.V. Seat Discs Fasteners Check Seats External finish Ductile iron EPDM Bronze Epoxy Coat TECHNICAL DATA Flanged inlet and outlet Table E Min. working pressure 220 kpa Max. working pressure 1200 kpa Max. temperature 60 C DIMENSIONS AND WEIGHT www.avg.net.au Tel: 1800 AVG AUS (284 287) 21