SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

Similar documents
SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

Solenoid Actuated Diesel Engine Air Shut Down Valves

MVX-Series Diesel Engine Air Shut Down Valves

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

Diesel Engine Shutdown Valves

Diesel Engine Shutdown Valve

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Diesel Engine Shutdown System

Automatic Fuel Shut Down Valves

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Flameproof Alternator

Flameproof Alternator

SELECTION, APPLICATION AND MAINTENANCE

E Series. Automatic Engine Overspeed Shut Down Valves

SELECTION, APPLICATION AND MAINTENANCE

Flameproof Alternator

E-M Series. Combined Manual and Automatic Engine Overspeed Shut Down Valves

Self-Exciting Flameproof Alternator

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

System Selection Guide

SELECTION, APPLICATION AND MAINTENANCE

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

Diesel Engine Air Intake Shutoff Valves

by AMOT World class diesel engine safety solutions Product Selection Guide

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50203 AIR INTAKE SHUT-OFF VALVES APPLICATION DODGE 5.9L CUMMINS.

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

Intake Air Shut-off Valve

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

PH2 AIR INTAKE EMERGENCY SHUT-OFF VALVES. APPLICATION C ½ DODGE 6.7L CUMMINS C DODGE 6.

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50207 AIR INTAKE SHUT-OFF VALVES APPLICATION FORD 6.7L POWERSTROKE.

E1186X Breather Kit. For Yanmar L48N Engines

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Pilot Operated 2-Way Gas Valves

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

Pressure and Temperature Switches

Pneumatic Indicating Relay

P0441-EVAP PURGE SYSTEM PERFO... P0441-EVAP PURGE SYSTEM PERFORMANCE

2-Way Temperature Sensing Valves

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Metal Particle Detector

Flameproof Alternators

ATB Series - Integral Throttle Body Actuators

Optimise your temperature control

3 Edition Product brochure GB AGA

Installation, Operation. IOM 1540 Rev. 1. Page 1 of

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY

Series 500. Liquid Level Transmitters. Instruction Manual

Is the heart of your engine protected?

ENGINE AND EMISSION CONTROL

Intake Manifold Replacement

C40008 & C40009 EXHAUST BRAKES

The enginewithintegrated water cooling

1 of 7 12/18/2016 9:15 PM

Quarter turn actuators Index

Metal Particle Detector

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Crankcase Ventilation Manager (CVM) Installation Instructions

DirectMount EXHAUST BRAKES

Installation Instructions. Standard Gate Valves

512 HO M285 Engine (FrechW) Maybach Engine M285

Thermostatic Control Valve

I-BFV.KIT Butterfly Valve Gear Operator Replacement

KIT CONTENTS

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER C (Gun Metal Grey Finish) 2015 Ford Mustang 2.

2011 Transit Connect Workshop Manual

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Tightness control TC. Product brochure GB Edition 12.10

2. Turbocharger System

SERIES 2000 GAS SAFETY SHUT OFF VALVE

2009 PCED Gasoline Engines SECTION 1: Description and Operation. Intake Air System

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

Model: ACP-12 AUTO COMPRESSOR PUMP SYSTEM 12 VDC INSTALLATION & OPERATION MANUAL. Phone:

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Inspection, Testing, and Maintenance Fire Pumps NFPA 25, Chapter 8 as amended by CCR, Title 19 Page 1 of 8


3-Way Temperature Control Valve

MultiPort II Lubricator

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

ARGONITE Fire Protection Systems

Evaporative Emissions

Thermostatic Control Valve

EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) H4DOTC

Part III : Technical Specification POS C)

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

Transcription:

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas) Selection, Application and Maintenance Valve Numbers SVX-300 to SVX-303 SVX-305 to SVX-308 SVX-500 to SVX-503 SVX-505 to SVX-508 SVX-800 to SVX-801 SVX-807 to SVX-808 CE0 (8) 0909 SVX_2

DESCRIPTION A range of and volt dc solenoid operated diesel engine air intake closure valves based on the standard Chalwyn slimfit 3, 5 and 8 butterfly valves. These products are available in basic flange mounted form but can also be supplied fitted with hose adaptors. These valves are designed to fail safe in that if electrical power is lost for any reason, the valve will always revert to the closed condition. All valves in this range are also available with fitted internal microswitch to enable status indication. B Typical Valve Arrangement for Types SVX-300 SVX-307 SVX-500 SVX-507 SVX-800 SVX-807 SVX-301 SVX-308 SVX-501 SVX-508 SVX-801 SVX-808 Important Note: The above listed valve types all require an external timer circuit to switch from pull to hold coils. - See Page 5. Optional Hose Adaptor Range C1 C2 (Min) C2 (Max) D A Main Dimensions (mm) and Features Without Microswitch Valve Type With Microswitch Voltage Nominal A B C 1 C 2 Bore Dia. (min & max) D SVX-300 SVX-301 SVX-500 SVX-501 SVX-800 SVX-801 SVX-308 SVX-307 SVX-508 SVX-507 SVX-808 SVX-807 76 (3 ) 76 (3 ) 7 (5 ) 7 (5 ) 203 (8 ) 203 (8 ) 161.0 161.0 217.0 217.0 317.5 317.5 111.5 111.5 167.5 167.5 257.0 257.0 37.5 37.5 45.5 45.5 56.0 56.0 82.5 to 1.5 82.5 to 1.5 102 to 157.5 102 to 157.5 136.5 to 185.5 136.5 to 185.5 95.5 95.5 99.5 99.5 104.5 104.5 2

Typical Valve Arrangement for Types B SVX-302 SVX-305 SVX-502 SVX-505 SVX-303 SVX-306 SVX-503 SVX-506 Important Note: The above listed valves are internally switched types and DO NOT require an external timer circuit to switch from pull to hold coils. Optional Hose Adaptor C1 C2 (Min) C2 (Max) D A Main Dimensions (mm) and Features Without Microswitch Valve Type With Microswitch Voltage Nominal A B C 1 C 2 Bore Dia. (min & max) D SVX-302 SVX-303 SVX-502 SVX-503 SVX-306 SVX-305 SVX-506 SVX-505 76 (3 ) 76 (3 ) 7 (5 ) 7 (5 ) 161.0 161.0 217.0 217.0 111.5 111.5 167.5 167.5 37.5 37.5 45.5 45.5 82.5 to 1.5 82.5 to 1.5 102 to 157.5 102 to 157.5 118 118 2 2 Notes: Maximum temperature of the engine intake air at the SVX valve not to exceed 150 C. (See also Installation (Mechanical) - page 5) For equivalent SVX valves for hazardous area applications - see Chalwyn Brochure CE239. 3 ValvesCE0 (8)

SELECTION Determine the size and position of the SVX valve to be installed. Within the various constraints imposed by the application, the valve should be as generously sized as possible. Check that the valve can be installed such that the electrical cable can be routed away without risk of damage. Determine voltage of valve required and whether a two wire (internally switched) or three wire solenoid is required with external switching operated by a customer supplied timer circuit. If a valve status indicator is required, select a valve with an internal micro switch. Chalwyn X valves are designed for flange mounting. Alternatively these valves can be supplied with fitted hose adaptors selected from the table below. Hose Adaptor Options 76mm (3 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-320 38 ( 1 1 / 2 ) HAX-322 44.5 (1 3 / 4 ) HAX-301 51 (2) HAX-302 54 (2 1 / 8 ) HAX-303 57 (2 1 / 4 ) HAX-304 60 (2 3 / 8 ) HAX-305 63.5 (2 1 / 2 ) HAX-306 67 (2 5 / 8 ) HAX-307 70 (2 3 / 4 ) HAX-308 73 (2 7 / 8 ) HAX-309 76 (3) HAX-3 82.5 (3 1 / 4 ) HAX-314 89 (3 1 / 2 ) HAX-319 102 (4) 7mm (5 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-501 89 (3 1 / 2 ) HAX-502 92 (3 5 / 8 ) HAX-503 95 (3 3 / 4 ) HAX-504 98 (3 7 / 8 ) HAX-505 102 (4) HAX-506 105 (4 1 / 8 ) HAX-507 108 (4 1 / 4 ) HAX-508 111 (4 3 / 8 ) HAX-509 114 (4 1 / 2 ) HAX-510 117.5 (4 5 / 8 ) HAX-511 1 (4 3 / 4 ) HAX-5 4 (4 7 / 8 ) HAX-513 7 (5) HAX-518 140 (5 1 / 2 ) HAX-523 152 (6) 203mm (8 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-807 178 (7) HAX-808 203 (8) 4

INSTALLATION (MECHANICAL) 1. In the case of a naturally aspirated engine, the Chalwyn SVX shut down valve should generally be fitted as close to the engine air intake manifold as possible. If an air intake flame trap is also fitted, the SVX valve must be installed upstream (air cleaner side) of the flame trap. 2. To avoid excessively high intake air temperature at the SVX valve when fitted to a turbocharged engine, it may be necessary to fit the valve either upstream of the turbocharger or downstream of the intercooler (if fitted). Again, if an air intake flametrap is also fitted, the valve must be installed upstream of the flametrap. 3. Where more than one SVX valve is installed on an engine, as in the case of an engine with multiple intake pipes, the shut down valve control system must be arranged to ensure all valves close simultaneously. 4. This valve may be installed either horizontally or vertically. 5. If hose adaptors are used, the mating hose should be of a reinforced type, provide adequate support for the valve and prevent excessive vibration. If necessary, additional support brackets mounted from the engine should be considered. 6. Particular care must be taken to ensure the integrity of the intake pipework between the Chalwyn valve and intake manifold. Ideally metal pipework should be used and any gaps kept as short as possible, (taking into account any relative movement) and closed by reinforced hose. 7. Any engine crankcase breather connections into the intake system between the SVX valve and engine, or any internal crankcase breather arrangement venting directly into the engine intake ports must be sealed and replaced by an external breather system venting either to atmosphere or to the intake system upstream of the shut down valve. External breather system kits for various engine types are available from Chalwyn. INSTALLATION (ELECTRICAL) Valve Types SVX-300, SVX-301, SVX-307, SVX-308 SVX-500, SVX-501, SVX-507, SVX-508 SVX-800, SVX-801, SVX-807, SVX-808 The solenoids fitted to these non-hazardous area shut down valves are three wire (external switching) types. A timer device must be fitted in the solenoid supply circuit to rapidly switch from pull to hold connections after powering the solenoid (typically less than 1 second). The control circuit for these devices must also incorporate an overload protection device and the supply cables must not exceed the following maximum lengths. 2.5mm 2 wire gauge : 2.7m ( volt types) or 10m ( volt types). 4.0mm 2 wire gauge : 4.2m ( volt types) or 16m ( volt types). Supply voltage: vdc (SVX-300, SVX-308, SVX-500, SVX-508, SVX-800, SVX-808) vdc (SVX-301, SVX-307, SVX-501, SVX-507, SVX-801, SVX-807) Pull current at 23 C : 46 amps ( volt types) or 25 amps ( volt types). Hold current at 23 C : 1.1 amps ( volt types) or 0.5 amps ( volt types). Pull coil: Must not be powered for more than three 30 second periods with 2 minutes to cool between each period. The solenoid must be allowed to cool to ambient before further energising of the pull coil. The black wire is the common return and must be connected to the negative terminal of the supply. The white wire is the pull coil supply. The red wire is the hold coil supply. For models with an internal microswitch, the microswitch connections are made as follows: Brown : Supply - common. Blue : Makes circuit when valve is open Black : Makes circuit when valve is closed. (Was yellow/green on early models). Maximum rating of microswitch at or volts = 2 amp. 5

Valve Types SVX-302, SVX-303, SVX-305, SVX-306 SVX-502, SVX-503, SVX-505, SVX-506 The solenoids fitted to these non-hazardous area shut down valves are two wire (internal switching) types. The control circuit for these devices must incorporate an overload protection device and the supply cables must not exceed the following maximum lengths. 2.5mm 2 wire gauge : 2.7m ( volt types) or 10m ( volt types). 4.0mm 2 wire gauge : 4.2m ( volt types) or 16m ( volt types). Supply voltage: vdc (SVX-302, SVX-306, SVX-502, SVX-506) vdc (SVX-303, SVX-305, SVX-503, SVX-505) Pull current at 23 C : 46 amps ( volt types) or 25 amps ( volt types). Hold current at 23 C : 1.1 amps ( volt types) or 0.5 amps ( volt types). For models with an internal microswitch, the microswitch connections are made as follows: Brown : Neutral Blue : Makes circuit when valve is open Yellow/ Green : Makes circuit when valve is closed Maximum rating of microswitch at or volts = 2 amperes OPERATION When powered the solenoid holds the air intake shut down valve in the open (engine run) condition. On loss of power the spring within the shut down valve assembly moves the valve to the closed (engine stop) position, i.e. failure of power supply gives a fail safe (engine stopped) condition. MAINTENANCE WEEKLY: MONTHLY: Visually check the valve, solenoid and cable for damage or deterioration. Withdraw from service if significant damage or deterioration is observed. Check that the fasteners locating the shut down valve and any associated intake system or support bracket fasteners are securely tightened. Check that any flexible hoses in the engine intake between the SVX valve and engine are free from damage and suitable for further service. Run engine, preferably at low idle. Use shut down control system emergency stop to close the intake shut down valve. The engine should stop within a few seconds. If not, check there are no leaks in the engine air intake system between the SVX valve and engine. If this does not resolve the problem remove the SVX valve to return to Chalwyn for investigation. 6

NOTES: 7

Chalwyn by AMOT www.chalwyn.com A division of Roper Industries Limited UK Western Way Bury St Edmunds Suffolk, IP33 3SZ Tel: +44 (0)84 715739 Fax: +44 (0)84 715747 USA 88 Fallbrook Drive Houston TX 77064 Tel: +1 (281) 940 1800 Fax: +1 (713) 559 9419 Canada 3230-97 Street Edmonton, Alberta, T6N 1K4 Tel: +1 (780) 465 4429 Fax: +1 (780) 469 6275 Chalwyn reserves the right to update this PRODUCT specification without prior notice.