R.A.D. Remote Activated Diffuser WIRELESS DIFFUSER CONTROL. 448 South Main Street / Verona, WI / (608)

Similar documents
SMT-AZC INSTALLATION / OPERATION MANUAL

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

FHT 8V Wireless Actuator

WPT Installation Manual. Wireless Pneumatic Thermostat- WPT-800 Series. 1. Overview. 1.1 Parts Included. 1.2 Prerequisites for Installation

COMPONENTS AND ACCESSORIES FOR THE AIR DIFFUSION, DISTRIBUTION AND REGULATION

QUICKSTART ESSENTIALS

VAV TERMINAL UNITS. VVD VAV Diffusers

PIM Pressure Independent Module

ACS LED SIGNALLING UNIT LINEAR SENSOR CALIBRATION. AS-i module / multi-voltage modules version

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72

BATTERY CHARGER Instruction Manual

Installation, Service, and Troubleshooting Instructions

ZoneTouch V2 Zone Control System Installation Manual

Discharge Air Control

CA 170 Owner's Manual

Front panel valves SV

Metasys Zoning Package Installation

BATTERY CHARGER RS-1000 Instruction Manual

Room Controller LS 990 / LS plus Stainless Steel / Aluminium

IntelliTrac X Series Hardware Installation Guide

RDG160TU Commercial Thermostat

Electro Controls. Temperature Controllers WattsIndustries.co.uk

HERZ Electronic room thermostat analog and digital

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 OPERATE 1

PIM Pressure Independence Module

DE EN FR FMR 800-M/C MASCHINENEMPFÄNGER MACHINE CONTROL RECEIVER CELLULE GUIDAGE D ENGIN.

Front panel valves SV

Door Lock System Controls

Remote control your Mercedes. climate KeylessGo Installation Manual

WITH. This Owner s Manual and the owner s manual for the Honda generator should be kept accessible so that they may be referred to at any time.

Wireless Thermometer model 00782W

Jupio Intelli Charger JBC0051 INSTRUCTION MANUAL. Thank you for purchasing this outstanding Jupio quality product!

Modulating Furnace Information. Warning on Meter Setting - Read First!

CA 650 Owner's Manual

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI

Installation and User Manual. with RAIN SENSOR.

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

Garden Thermometer with Solar Lighting

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Description. functions including single duct pressure dependent or pressure independent systems.

Virtual Measurements & Control. VC210 Operators Manual

BATTERY CHARGER Instruction Manual

With Integrated AC Unit Control. Installation and User Manual

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Automatic Swing Door Operator DFA 127 IN (Inverse) Operating instructions E

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

THEFT DETERRENT SYSTEM

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Model DS7060 Handrail Scale. User Manual

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

Metasys Zoning Package

FT AA Diesel Locomotives Owner s Manual

CA 6550 Owner s Guide

RA-2000 Airflow Measuring System

CA 180 Owner's Manual

Grain Moisture Meter. Operators manual

Thermometer models 02023/02028/02053/02054

Keyless Go (KG) 218 HO Keyless Go (GC_JL_JM)

Ventilation in balance

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Regulation HRmural. Installation and user s manual

Thermometer models 02023, 02028, 02029

1 Overview. 2 WPT Installation. WPT Installation Manual Document No , Rev 17. Wireless Pneumatic Thermostat- WPT-800 Series

INSTALLER MANUAL USER MANUAL. Contents

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

Touch Sensor 2 plus Installation Instructions

Air-conditioning. split ducted systems

BLBd

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

SE8300 Series Installation Guide 24 Vac Low Voltage

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

Deadband Wireless Pneumatic Thermostat- WPT-800-DB Series

ca 1553 Owner s Guide

Technical Bulletin AA 304. Central Locking System. m.y. 97

Ventilation in balance

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

ATA 49 AUXILIARY POWER UNIT

Owner s Guide CARS & CA2LCD5

DASSAULT AVIATION Proprietary Data

R81EAA-2 Economizer Circuit Board

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

ATM SERIES THREE PHASE MULTI - TURN

Intelligent NiMH/NiCd/Li-ion Charger TN456

GETTING TO KNOW YOUR 2019

STR Circular VAV Terminal Units

Table of Contents. Owner s Guide

ALPHA ALTERNATOR 12/90, 12/130, 24/75, 24/110 & 24/150

All-steel construction For installation of #16 diffuser when not using a damper. Golden Sand enamel finish. 12 Butterfly Damper

Installation and Start-Up Instructions

FN Fan-Coil Units High-Performance, Horizontal

RX 350 Lexus Personalized Settings

Operating instructions Flow monitor SI / / 2013

Owner s Guide. ca6553 ca6553sst

Metasys Zoning Package Overview

Weather Thermometer models 00754/00771W/00772W/00773W/00774W

IMPORTANT! Remote Control Instructions

SoilStik ph Meter PRODUCT MANUAL. Item # 2105

Transcription:

U S E R M A N U A L R.A.D. Remote Activated Diffuser WIRELESS DIFFUSER CONTROL 448 South Main Street / Verona, WI 53593-1499 / (608) 845-6411

2 Introduction The R.A.D. consists of the Actuator on the bottom of the diffuser that controls the butterfly damper and the Wireless Remote control used to directly adjust the airflow from the diffuser or adjust the airflow based on space temperature. A wall mounting bracket is also included. Wall Bracket SELECT LOCK Damper Actuator Remote Control

Introduction 3 Actuator The Actuator has been installed on the bottom of the diffuser. The small pushbutton switch allows you to program the address of the Actuator using the Remote. Each Actuator can be set to any one of 16 groups and any one of 32 zones within each group. Multiple Actuators can be set to the same group and zone so they respond together. The LED will indicate the status of the damper (red for fully closed and green for fully open) or will blink red or green when the Actuator has received a valid command and is opening or closing. Temperature sensor Programming Switch LED Indicator

4 Remote The Remote is battery powered and is used to control the Actuator by direct control of the butterfly damper (from fully closed to 100 open) or by controlling the damper based on setpoint temperature, space temperature and supply air temperature. The LCD displays the status of any diffuser and the keys allow you to set the addresses of the Actuators and operate the R.A.D. in Airflow or Thermostat mode. Temperature Sensor LCD Display SELECT LOCK Soft Touch keyboard

LCD Display 5 Airflow Mode Indicator. Thermostat Mode Indicator. Zone number (1 to 32) Indicates of in Thermostat mode. BAT o F SET Keyboard Lock indicator. Keyboard Locked. Keyboard Unlocked. Low battery indicator. Indicates SET when setting airflow percentage or setpoint temperature. Indicates when setting airflow percentage. Displays the Airflow percentage, setpoint temperature or the Area number when setting Area number. Damper is 80 open. SET While airflow is being set. o F Space temperature is 72.0oF. o F SET Setpoint temperature. Selecting Area number (1 to 16)

6 Installing Batteries Back of Remote To open battery compartment, press here and slide open. AA BATTERY AA BATTERY Install two AA alkaline batteries as shown and replace battery cover. WARNING: Reversing batteries can damage control.

Setting the Diffuser Zone and Area Number. The Area number or group allows you to separate your diffusers into up to 16 Areas or groups. The Area number can respond to different floors or departments. Within each Area you can have up to 32 Zones. Each diffuser can have a different Zone number. Multiple diffusers can have the same Zone number so they respond together. First select the Zone number (see page 10) and then the Area number (see page 10). Press the small program switch on the diffuser Actuator (see page 3) and the Green LED will turn On. For 30 seconds the Actuator will accept a new Zone and Area number. Press and hold the SELECT key for about 8 seconds until the PRO appears in the LCD. Press to clear the LCD. 7 SELECT Press and hold the SELECT key until PRO appears in the LCD. Then press. SET

8 Selecting Airflow or Thermostat Mode In Airflow mode you have direct control over the damper opening. You can set the damper from completely closed (0) to fully open (100). A single Remote can control any number of diffusers. In Thermostat mode the diffuser is controlled by the temperature set on the remote, the space temperature and the supply air temperature. In Thermostat mode the Remote must remain in the space being supplied by the diffuser. The Remote can sit on a desk or be mounted on a wall using the bracket provided. The Remote will monitor and display the space temperature and periodically and automatically adjust the diffuser for best comfort. To select a mode, first select the Zone number (see page 10). Momentarily press the SELECT key twice and use the or keys to toggle between Airflow and Thermostat mode. Press to save the mode. SELECT SELECT o F

Setting the Airflow In Airflow mode you can set the Airflow or damper position from from 0 to 100 open. First select the Zone (see page 10) and Area numbers (see page 10). 9 SET Setting the Comfort Temperature In Thermostat mode you can set the comfort or setpoint temperature from 50 to 80.5 of. First select the Zone and Area numbers (see page 10). o F SET

10 Selecting the Zone Number Momentarily press the SELECT key once and use the and Down keys to select the Zone number. Press the key when finished. SELECT Selecting the Area Number Momentarily press the SELECT key three times and use the and Down keys to select the Area number. Press the key when finished. SELECT SELECT SELECT

Setting the Lock Code In Thermostat mode it may be desirable to lock the keys so that the Remote can only be changed by an authorized person. First, you must select a lock code (number from 1 to 21). momentarily press SELECT and then LOCK and use the and Down keys to select the lock number. 11 SELECT LOCK Locking and Unlocking the Keys Momentarily press LOCK and use the and Down keys to select the lock number. Press to lock or unlock the keys. The lock symbol will indicate whether the keys are locked or unlocked. LOCK

12 Low Battery Indictor The battery symbol will turn On to indicate the batteries should be changed. The symbol will blink to indicate the batteries should be changed immediately. BAT Battery symbol