Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION

Similar documents
Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

Feed Pumps Direct Drive Series 1.1.

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Feed Pumps Direct Drive Series 1.1.

Oil/Air Cooler Units

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048

HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm

up to size 381 up to PN 0.5 bar up to T = 80 C Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TSE

Feed Pumps VP / VPB / VPBM

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

3- and 4-Way Ball Valves KH3/KH4

Clamping and drive module

Pressure Compensated Flow Control Valves SRVR/SRVRP

HYDAC (Three-Phase Current) Compact Power Units CO1

Centrifugal pumps. Main catalogue.

Asynchronous motors. 7/2 Main spindle motors for SIMODRIVE 611 7/2 Introduction

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives Technical Data Sheet

IPVS High-pressure Internal Gear Pumps Technical Data Sheet

MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

Flow Control Valves and Flow Control Valves with reverse flow check DV/DRV

2/2-Way Pressure Relief Valve CX DBV (Right-Angle Design)

Proportional Pressure Reducing Valve PDM08130

PAB Atex-certified centrifugal pumps

Axial Piston Variable Pump A2VK

Vane pumps, direct controlled Type PV7...A

IPV catalog High-pressure internal gear pumps

Coolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications

HYDAC DC Compact Power Units DC1

Technical Data Sheets

IPCA Medium-pressure Internal Gear Pumps Technical Data Sheet

GMP-Type. Key Features: Integrated Motor-Pump Units

IPC Medium-Pressure Internal Gear Pumps Technical Data Sheet

Table of contents. Three-phase asynchronous motors DA

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

High-pressure compressor for breathing air Type MX 250 open and MX 300 open. Maximum Pressure. A power package with allrounder qualities

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Pilot-Operated Directional Control Valves Series D3 - D11

Directional Control Valve Series 4D01 (DENISON)

Axial Piston Variable Pump A2VK

HYDAC Fluidtechnik: Industrial Valves FLOW CNTROL VALVE COMPENSATED PRESSURE VP-SR X.XXX.0/01.09 E / D E /08.

Change-Over Pressure Filter DFDK

1106A-70TAG4. Series kwm 1500 rpm ElectropaK. Basic technical data. General installation

EIPS2 INTERNAL GEAR PUMPS

SINGLE STAGE TWO STAGES

Company name: GSI Created by: SLK Phone: (65) Date: 13/03/2017 Client: Client Number: Contact:

8 Technical Reference

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

Pressure control for air and water Type CS

NCF fans 60Hz. Protection class IP 55

Proportional Pressure Relief Valve Series RE*T

IPV Catalog High-pressure Internal Gear Pumps

3/2 Way Ball Valves KHB3K

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

Pressure Relief Valve DB12 CE

Series description: Wilo-Drain STS 40

MODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Electric machine, permanent magnet internal

MODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

MTB /183 A-F-A-BQQV 400D-2 11kW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

Change-Over Inline Filter RFLD Welded Version

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

DBC-1 DEIF Battery Charger

Technical Data 2506A-E15TAG3 2506A-E15TAG Series. Diesel Engine - ElectropaK

PS/PSL Centrifugal pumps

Variable Displacement Plug-In Motor A6VE

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

Electronic Pressure Switch EDS 3000

UD and UC Gear pump unit

Heat Exchangers. Evaporator Catalogue

Electric machine, permanent magnet internal

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

ASM. Asynchronous Spindle. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

Sectional Directional Control Valve RSQ 240

Technical Data Sheets

Bell Housing. RC series bell housing. Transmission Engineering. Hydraulic-Components. Oil-coolers

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

Technical Data Sheets

BEARINGS The lower bearing assemble is constructed to allow continuous operation when fully submerged in wastewater.

Immersion Pumps PMS and PMS-T sealless

Change-Over Inline Filter AFLD to API 614

ay Manifold Mounted KHP3K

Company name: Created by: Phone:

Internet For latest information, PDF catalogs and operation manuals

W Datasheet: DIN Rail Contactors, series AMPARO

Electronic Temperature Sensor ETS 300

GLOBAL STANDARD COOLER

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

Transcription:

Cooling Systems FLKS - S/1.0/W... FLKS - L/1.0/W... 1. DESCRIPTION 1.1. APPLICATIONS Cooling circuits: Cooling of AC main drives Cooling of motor spindles on machining centres Cooling of transmission and braking systems Cooling of servo and linear motors 1.2. CONSTRUCTION The HYDAC FLKS fluid air cooling system consists of an axial fan, a tank, a submersible pump and a heat exchanger. The submersible pump built into the plastic tank pumps the coolant through the heat exchanger. The axial fan provides the necessary cooling air through the heat exchanger.

2. TECHNICAL SPECIFICATIONS 2.1. COOLING CAPACITY AND FLOW RATE OF PUMP (see graphs 2.12 and 2.1) 2.2. PERMISSIBLE FLUID 2.2.1 Preferred fluid: Mains water with 0-40% GLYSANTIN G48 PROTECT PLUS (BASF) 2.2.2 Other permissible cooling fluids: Mains water with 0-40% -PARAFLU 11 Mains water with 5-10% -MOTOREX COOLANT-F Other coolants on request! 2.. PERMISSIBLE TEMPERATURES 2..1 Fluid temperature max. 60 C 2..2 Ambient temperature 0 C to +40 C 2.4. MOUNTING POSITION: VERTICAL (TANK AT THE BOTTOM) 2.5. NOISE LEVEL MEASURED TO DIN4565 PART 1 FLKS-S: 74 db(a) 4pole 50Hz 79 db(a) 4pole 60Hz FLKS-L: 64 db(a) 4pole 50Hz 68 db(a) 4pole 60Hz 2.6. DIRECTION OF ROTATION Pump: when looking at motor fan, clockwise Cooling fan: when looking at motor fan, clockwise 2.7 TANK SIZE: Max. 21 l, Min. 11 l 2.8. WEIGHT 4.5 kg 2.9. ELECTRICAL CONNECTION Terminal box of electric motor 2.10. HYDRAULIC CONNECTION Pump: P = G /4 Heat exchanger: K = G 1 Tank drain: T = G /4 Do not reduce pipe cross-section pre-determined by the threaded connections (see 2.12). 2.11. ELECTRICAL SPECIFICATIONS Design voltage range: 80-420 V star / 220-240 V delta - 50Hz 440-480 V star / 254-277 V delta - 60Hz (motor rating x 1.15) Voltage tolerances to EN 6004-1 ±5% Motor rating at 50 Hz: Model: FLKS-S Cooling fan 4 pole 0.7 KW Pump 2 pole 0.5 KW FLKS-L Cooling fan 6 pole 0.25 KW Pump 2 pole 0.5 KW 2.12. PUMP FLOW RATE GRAPH The flow rate of the pump depends on the system characteristics (pipe cross-sections, pipe lengths, threaded connections). Generally, the following applies: The smaller the pressure losses in the system, the greater the flow rate and therefore the greater the cooling capacity. Flow rate tolerance ±10% 5 4.5 4.5 2.5 2 0 5 10 15 20 25 Q [l/min] 2.1. COOLING CAPACITY GRAPH Cooling capacity tolerance ±5% 0.400 0.50 0.00 0.250 0.200 Operating range 0.150 0 5 10 15 20 25 Q [l/min] 4-pole 60 Hz (S) 4-pole 50 Hz (S) and 6-pole 60Hz (L) 6-pole 50 Hz (L) 2

. MODEL CODE FLKS S / 1. 0 / W / TP / 400 50 / 1 / 0 (also order example) www.comoso.com Fluid Air Cooling System FLKS Nominal size Fan speed S = 4 pole (1500 rpm ) L = 6 pole (1000 rpm ) Type code Modification number Fluid W (see 2.2.) Submersible pump 2 pole (2800 rpm ) 0.5KW for flow rate, see graph 2.12 Motor voltage (standard) 80-420 V star / 220-240 V delta - 50Hz 440-480 V star / 254-277 V delta - 60Hz (motor rating x 1.15) Other voltages on request Paint 1=RAL 704 (standard) Accessories (see Point 6.) 0 = Standard (without accessories) 1 = Electrical fluid level and temperature monitoring 2 = Pressure gauge = Electrical fluid level and temperature monitoring + pressure gauge 7 = Electrical fluid level monitoring 11 = Flow indicator 15 = Flow indicator and electrical fluid level monitoring

4. DIMENSIONS approx. View of heat exchanger 1 Heat exchanger K = G 1 2 Cooling fan motor Pump P = G /4 4 Plastic tank T = G /4 T1 = M20x1.5 5 Filler breather cap Earthing screw 4.1. CIRCUIT DIAGRAM 5. ELECTRICAL PIN CONNECTIONS The motor is connected electrically via the terminal box. The appropriate circuit must be selected according to the available mains voltage. The circuit diagram is displayed in the terminal box. Standard circuit 4

6. ACCESSORIES 1. ELECTRICAL FLUID LEVEL AND TEMPERATURE MONITORING: Fluid level and temperature switch 6 C (N/C); Monitors the level of coolant and the temperature in the tank. 7. NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 2. PRESSURE GAUGE: Visual pressure indication of the coolant at the pump.. ELECTRICAL FLUID LEVEL AND TEMPERATURE MONITORING + PRESSURE GAUGE: Fluid level and temperature switch 6 C (N/C); Monitors the level of coolant and the temperature in the tank. Also provides visual pressure indication of the coolant at the pump. 7. ELECTRICAL FLUID LEVEL MONITORING: Fluid level switch (N/C) to monitor the coolant level in the tank. 11. ELECTRICAL FLOW INDICATOR Flow rate monitoring of the coolant (switch-off point set to 5 l/min). 15. FLOW INDICATOR AND ELECTRICAL FLUID LEVEL MONITORING Flow rate monitoring of the coolant (switch-off point set to 5 l/min) and fluid level switch (N/C) to monitor the coolant level in the tank. Other accessories on request. 5