Automatic (Air Release) Air Valve

Similar documents
CUSTOM COMBINATION AIR VALVE

Wastewater Air Release Valve Models 48A, 49A

Crispin Valves Operating Guide. Crispin

1451 Control Valve. General Instructions. Table of Contents

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

BERMAD Irrigation. High Performance Plastic Valves. 100 Series - Water Control Solutions

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

Instructions for Installation, Operation, Care and Maintenance

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

IOM Manual. IOM Manual. Series 76/77.

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation, Operation and Maintenance Instructions

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

OPERATING AND MAINTENANCE MANUAL

METERING VALVE 2" STEM GUIDED

Installation, Operation, and Maintenance Manual

IOM IR-110-X. Solenoid Control Valve

627 Series Pressure Reducing Regulators

Check List for Optimal Filter Performance

BERMAD BERMAD BERMAD WW M

Operation and Maintenance Manual

To ensure proper installation, digital pictures with contact information to before startup.

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

SERIES PC INSTRUCTION AND OPERATION MANUAL

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8

Val-Matic 4-20 Air/Vacuum Valve

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Inverted High Pressure Fluid Filters

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

Flow Control Valve IOM 770-U

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE MOUNTED LIQUID ELIMINATOR

627 Series Pressure Reducing Regulators

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

Y690A Series Pressure Reducing Regulators

Pressure Independent Flow Controller. SkoFlo Valve Model SF10000DRS OPERATION AND MAINTENANCE INSTRUCTIONS

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

CIRCLE SEAL CONTROLS

METERS Data Collection CONTROL. Installation Guide. Residential Water Meters

Y690A Series Pressure Reducing Regulators

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

Type MR108 Direct-Operated Backpressure Regulator

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

Series A Floating Ball Valve Installation, Operation & Maintenance XXXX - X X X X X X X. Base Part Numbers. Trim Option Suffix Code

TYPE E Main Valve Sizes 3 /8 through 12

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M

Type EZR Relief Valve or Backpressure Regulator

Technical Data PRESSURE (PSI) DIMENSIONS inches AND WEIGHTS pounds

INSTALLATION & MAINTENANCE MANUAL

Air Operated Grease Ratio Pumps 50:1 BGRP

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR

Installation and Service Instructions

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL DATA 1-1/2 (dn40)

SWING CHECK VALVES SERIES 52-SC SERIES 600

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Table of Contents D. Fluid/Air Modules...2 F34, FA2...2

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

1/2" AIR DRIVEN DIAPHRAGM PUMP

TECHNICAL DATA. Q= C v P S

INSTALLATION & MAINTENANCE MODEL mm

RAIN BIRD - AQUAGATOR AQUAGATOR INSTALLATION & TROUBLESHOOTING MANUAL

SB UNDERGROUND AIR VALVE ASSEMBLY INTRODUCTION FEATURES INSTALLATION

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

Welker Automatic Insertion Diffusing Probe Model AIP-3DP

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

Installation Notes for Caterpillar 3516 Gen Set Package (Up to 255 Gallon Sump Capacity)

IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

105 Commerce Way Westminster, SC Tel: (864) Fax: (864)

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

NEW. BERMAD Irrigation 100 Series - High Performance Valves. Water Control Solutions

Type MR105 Direct-Operated Pressure Reducing Regulators

House Hydrant Installation Instructions

STEP-BY-STEP INSTALLATION GUIDE

161 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Type 289P Pilot-Operated Relief Valve

SERIES 270A HIGH SIDE FLOAT VALVES BULLETIN 270A-SB11-02 SERVICE BULLETIN

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

Transcription:

Automatic (Air Release) Air Valve Model A10 /A11 Installation, Operation and Maintenance Manual (IOM)

Table of Contents General...Page 2 Safety...Page 2 Operational Data...Page 3 Materials and Connections...Page 3 A10 Parts List...Page 4 A11 Parts List...Page 5 Unpacking and post shipment inspection...page 6 Site Preparation...Page 6 Installation...Page 7 Start-up and first operation...page 8 Operation and Maintenance...Page 8 Inspection...Page 8 Troubleshooting... Page 9 Disassembling the A10 valve... Page 10 Reassembling the A10 valve... Page 11 Disassembling the A11 valve... Page 12 Reassembling the A11 valve... Page 13 1

General BERMAD A10 / A11 is a high quality automatic air release valve that allows efficient release of air pockets from pressurized pipes. With its advanced design this automatic air release valve provides excellent protection against air accumulation with improved sealing in low pressure conditions. This document is the Installation, Operation and Maintenance manual (IOM) of this valve; it describes the procedures required for proper usage of the valve. Safety Since Air Valves operate in pressurized water systems you are required to carefully read this manual before using the valve. Handle the valve with care and make sure to comply with all the relevant required safety instructions and standards, general and local. 2

Operational Data Pressure rating ISO PN10, ANSI / ASME 150 Operating pressure range A10: 0.1-10 bar / 1.5-150 psi A11: 0.02-10 bar / 0.3-150 psi Operating temperature Water up to 60 C / 140 F Materials and Connections Body material Glass-reinforced Nylon Inlet diameter DN20, DN25 (¾", 1") Connections Threaded Male BSPT / NPT Outlet types Sideways 3

A10 Parts List Body (#2) Peal Seal (#5) Float (#3) O-Ring (#5010) Base (#1) Test Point (#7) 4

A11 Parts List Body (#2) Auto Orifice O-Ring (#5000) Auto Orifice (#14) Body + Auto Orifice kit # XXXX Auto Orifice Seal (#18) Float (#3) O-Ring (#5010) Base (#1) Test Point (#7) 5

Unpacking and post shipment inspection Make sure that till the actual installation the valve remains dry and clean in its original package. Unpack the valve and make sure that all the wrapping materials are removed. Before installation it is necessary to inspect that no damage to the valve had occurred during shipment; do not install a damaged valve. Verify that the valve to be installed meets the design specifications of the specific installation site; take extra care and make sure that the expected system pressure complies with the pressure rating of the valve. Site Preparation Air Valves located above ground should be protected from freezing, contamination and vandalism. If the valve is to be installed in a pit, make sure that the pit has proper drainage and sufficient dimensions for servicing the valve. Flush the pipeline prior to the Air Valve installation in order to prevent damage to the valve internals due to large debris carried by the water during startup. The A10 / A11 Air Valves are not to be used in systems containing high suspended solids; consider selecting other Bermad Air Valve models for such water type. 6

Installation Typical Applications Irrigation control head Protection against air accumulation at filtration and fertilization stations and downstream of main control valves. Infield systems Protection against air accumulation near water meters and automatic regulators. Landscape irrigation Protection against air accumulation. Installation instructions Install the Air Valve as close as possible to the pipe, at a high point of its circumference, in vertical position (within 5 degrees of vertical alignment) and with its inlet facing down. The diameter of the pipe connecting the Air Valve with the pipeline should be at least equal to the Air Valve inlet diameter. Install a shutoff valve between the Air Valve and the pipeline for allowing easy inspection and maintenance. 7

Start-up and first operation Open the shutoff valve and verify that the Air Valve connections are not leaking; if needed follow the troubleshooting instruction section of this document. Please note that at the first time the valve is filled up some water may exit through its outlet port. Prevent water hammer during startup and pipeline filling; maintain the velocity lower than 0.5m /sec (1.6 feet /sec). Consider using other BERMAD Air Valve models with Surge Protection features in systems where higher velocity is expected. Operation and Maintenance Principles of Operation During pressurized operation of a pipeline, air accumulates in the upper part of the Air Valve chamber, causing the float to gravitate downwards. This in turn causes the automatic orifice to open, releasing the accumulated air. Once the air is discharged, the water level and float rise, causing the automatic orifice to close. Inspection The valve does not require any specific maintenance, however a periodical inspection of the seals is recommended for removing debris and foreign objects. 8

Troubleshooting Symptom Leakage at the inlet connection Leakage at the valve cover Leakage at the valve s outlet Valve does not release air Action Tighten the valve connection, use thread sealant. Check whether any part /seal is damaged. Tighten the valve s cover Flush the valve to remove debris, dissemble and inspect the valve s orifice, float and seals. Remove any foreign objects, check and replace any damaged part. Verify that the operating pressure does not exceed the valve s rated working pressure. Check and remove foreign objects. Check the orifice's area for leaks. Clean the valve s internal parts, replace if necessary. Consult Bermad if the symptom continues. 9

Disassembling the A10 valve 1. Release the valve s Body (Part #2) by turning it counterclockwise, un-screw and remove it from the valve s Base (Part #1). Make sure that the valve parts, seated within the cover do not fall out of the cover. 2. Inspect the valve basis O-Ring (#5010) and if necessary replace it with a new one. Make sure that the new O-Ring is seated correctly in its designated groove in the valve s basis. 3. Pull the float assembly out of the valve s Body. 4. Inspect the float s Peal Seal (Part #5) and the float (Part #3) for wear and tear. If necessary replace the old parts. 5. Replacing the Peal Seal: a. Remove the old seal b. Wet the new Peal Seal (Part #5) with clean water c. Use the Insertion Assistance Handle and insert the loose end of the Peal Seal (Part #5) A to its designated groove in B the float (Part #3). Make sure that the serrated Fig. A side of the seal (A) is facing the float flat side (B) as shown in the Fig A. d. Once the Peal Seal is correctly seated in place cut the Insertion Assistance Handle and discard it. 10

Reassembling the A10 valve 1. Insert the float with the Peal Seal to its place within the cover. Make sure that the Peal Seal remains straight during the insertion process of the float to the cover. See Fig B. 2. Make sure that the valve s basis O-Ring (Part #5010) is fully inserted to its groove within the basis. See Fig C. 3. Reassemble the valve cover to the valve basis by screwing it on the basis thread. Tighten the cover till Bermad's logo is parallel with the wrench plats of the basis. See Fig D. 4. The valve is reassembled, perform a complete start up procedure as described above. Fig. B Fig. C Fig. D 11

Disassembling the A11 valve 1. Release the valve s Body (Part #2) by turning it counterclockwise, un-screw and remove it from the valve s Base (Part #1). Make sure that the valve parts, seated within the cover do not fall out of the cover. 2. Inspect the valve basis O-Ring (Part #5010) and if necessary replace it with a new one. Make sure that the new O-Ring is seated correctly in its designated groove in the valve s basis. 3. Pull the float assembly out of the valve s cover. 4. Inspect the Auto Orifice (Part #14), the Auto Orifice Seal (Part #18) and the Float (Part #3) for wear and tear. If necessary replace the old parts. 5. Replacing the Auto Orifice Seal: a. Use a sharp knife or scissors and carefully cut and remove the Auto Orifice Seal (Part #18) out of the float (Part #3). See Fig D. b. Pull the Auto Orifice (Part #14) Fig. D out of its seat in the far end of the cover. c. Inspect the Auto Orifice O-Ring (Part #5000) and replace it if necessary 12

Reassembling the A11 valve 1. Re-insert the Auto Orifice (Part #14) with its O-Ring (Part #5000) to its seat in the valves cover. Use a conduit tool to guide the insert to its place. Take an extra care not to damage the Auto Orifice Hole area during the insertion process. Make sure that the insert is properly seated and snapped-in locked to its place. See Fig E. 2. Make sure that the valve s basis O-Ring (Part #5010) is fully inserted to its groove within the basis. See Fig F. 3. Insert the float assembly to its place within the valve cover. Make sure that the float is inserted along its conduit grooves and in the correct orientation. See Fig G. 4. Reassemble the valve cover to the valve basis by screwing it on the basis thread. Tighten the cover till Bermad's logo is parallel with the wrench plats of the basis. See Fig H. 5. The valve is reassembled, perform a compete start up procedure as described above. Fig. E Fig. F Fig. G Fig. H 13

info@bermad.com www.bermad.com