PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

Similar documents
Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Engine Generator Circuit Breakers

15-I73E CAT REF.

14-I73E CAT REF.

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Electric vehicle auxiliary fuses 500 Vdc, A

Product Line Overview. The Most Logically Designed Contact Assembly

1489-M Circuit Breakers

Miniature Circuit Breakers

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

Magnetic and Hydraulic-Magnetic Circuit Breaker

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

18-I73E CAT REF.

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

MS General Information Extended Product Type: MS

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Technical data for manual motor starters Type MS325

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

PD-Series Ground Fault Circuit Protection

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

DPX earth leakage DPX 3 -I earth leakage

Magnetic and Hydraulic-Magnetic Circuit Breaker

6.3 mm reverse quick connect

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Technical Information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Electronic overload relays EF205 and EF370

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

12-I73Eb CAT REF.

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Low voltage moulded case circuit breaker EB2

KT4 Manual Motor Starter

Thermal Overcurrent Circuit Breaker 3120-F...

Series KTU7 UL489 Molded Case Circuit Breakers

Magnetic and Hydraulic-Magnetic Circuit Breaker

Bolted contact switches. Pringle switches

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

DPX Magnetic only

Ideal for use as a manual starter

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Magnetic Overcurrent Circuit Breaker

Circuit Breakers Naval Shipboard Use

Type BR thermal magnetic trip curve results

Molded Case Circuit Breakers

cor Long Run Experience

Thermal-Magnetic Circuit Breaker M1-...

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Bulletin 1489 Circuit Breakers. Selection Guide

Thermal-Magnetic Circuit Breaker 201/-WA

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

AF40... AF96 3-pole contactors Technical data

PB-Series. GFCI/ELCI & Panel Seal

Series KTU7 UL489 Molded Case Circuit Breakers

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

Electronic circuit breaker EBU10-T

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Thermal Overcurrent Circuit Breaker 3120-F...

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Electronic Circuit Breaker ESS20-0..

Molded Case Circuit Breakers

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Submersible Vacuum Fault Interrupters

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Control Circuit Protection

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Low voltage moulded case circuit breaker EB2

Supplementary Protectors. Circuit Breakers & Circuit Breakers & Supplementary Protectors Contents

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

DPX Electronic + earth leakage

AR circuit breaker - Hydraulic magnetic,

TMC 91H is now TMC 60 C Series

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Transcription:

Supersedes October 2013 photovoltaic circuit breakers Contents Description Page Product description........................ 1 PVGard 600 Vdc........................... 2 Technical data........................... 2 Dimensions............................ 3 Time/current curves...................... 5 PVGard 1000 Vdc.......................... 6 Technical data........................... 6 Dimensions............................ 7 Time/current curves..................... 15 Product description Thermal-magnetic circuit breakers Designed to meet UL 489B for solar photovoltaic circuit protection Both 100% and 80% rated breakers available 50 C calibrated Can be applied in grounded, ungrounded, or bipolar systems Ability to open on signal from DC arc or ground fault detector Two PVGard lineups: 600 Vdc per-pole breaker and switch; each pole rated 600 Vdc 1000 Vdc poles-in-series breaker and switch; requires poles in series connection UL File EE350638, Category Control Number DIUR Table 1. PVGard 600 Vdc Current Ratings by Frame Frame ampere Rating JG PVS 90 250 KD PVS 100 400 Table 2. PVGard 1000 Vdc Current Ratings by Frame Frame ampere Rating FD PV 30 100 KD PV 125 350 LG PV 250 400 MDL PV 300 600

PVGard 600 Vdc Technical data Table 3. Technical Data for PVGard 600 Vdc Per-Pole Solar PV Circuit Breakers JG PVS Number of 600 Vdc circuits 3 3 KD PVS Maximum voltage rating 600 Vdc 600 Vdc Ampere range 90 250A 100 400A Interrupting capacity at 600 Vdc 1.2 ka 3 ka Time constant 1 ms 1 ms Trip unit type Thermal-magnetic Thermal-magnetic Rated impulse withstand voltage Main conducting paths Auxiliary circuits 8 kv 4 kv 8 kv 4 kv Endurance Mechanical operations Electrical operations Maximum switching frequency 10,000 400 240 per hour 6000 400 240 per hour Third-party certification UL 489B UL 489B Environment Design ambient temperature Maximum current at 60 C, as % of rated current Maximum current at 70 C, as % of rated current Operating temperature range Storage temperature range Suitable for freeze temperatures to 40 C Relative humidity 50 C 93% 85% 20 C to +50 C 20 C to +70 C Option 0 to 95% noncondensing Suitable for reverse-feed applications Yes Yes Mounting permissible mounting position 50 C 93% 85% 20 C to +50 C 20 C to +70 C Option 0 to 95% noncondensing 90º 90º 90º 90º Connection diagrams Load Suitable for grounded or ungrounded systems Suitable for quantity (3) 600 Vdc circuits Terminations Al/Cu wire TA250FJ: (1) #8 350 kcmil TA300K: (1) #3 350 kcmil 3TA251FJK1: (2) 2/0 (2) 4/0 a TA350K: (1) 250 500 kcmil 3TA251FJK2: (2) 2/0 (2) 4/0 b TA403K: (2) 1/0 400 kcmil 3TA402K: (1) 500 750 kcmil c Cu wire T250FJ: (1) #4 350 kcmil T300K: (1) #3 350 kcmil Dimensions in inches (mm) Height Width Depth 7.00 (177.8) 4.13 (104.9) 3.57 (90.7) Weight in lbs 6.6 11.42 a Three terminals with terminal shield as a kit. b Three terminals with two interphase barriers as a kit. c Not UL 489B recognized size for maximum of 400A breaker. 10.13 (257.3) 5.50 (139.7) 4.10 (104.1) 2

Technical Data TD01211004E Dimensions JG PVS 90 250A breaker outlines and drilling plans 2.06 (52.4) 4.13 (104.8) 3.57 (90.6) 3.34 (84.9) 0.50 (12.7) Line End 1.91 (48.4) 4.99 (126.8) 2.91 (73.8) 0.78 (19.8) 6.28 (159.5) 6.50 (165.1) 7.00 (177.8) On 23.5 Tripped 10.5 1.77 (45.0) 0.38 (9.5) 3.95 (100.4) 0.99 (25.0) 1.98 (50.4) 3.97 (100.7) Off 4.0 Reset 6.4 A 0.38 (9.5) Pivot 3.10 (78.8) 0.93 (23.7) 0.69 (17.5) 0.69 (17.5) Load End 4X Ø 0.20 (5.0) through 0.150 (3.81) from Top, Line End 0.154 (3.91) from Top, Load End 0.266 (6.76) 0.50 (12.7) from Bottom, Both Ends for M4 x 0.7 x 90 mm Mounting Screws 0.03 (0.8) Dimensions for Terminal Shield 1.19 (30.2) 0.59 (15.1) 0.50 (12.7) 0.25 (6.4) 3.34 (84.9) B Section A-A 3.44 (87.3) 0.63 (15.9) 0.13 (3.2) 1.00 (25.4) 1.94 (49.2) Breaker Dimensions Status A B Force, Lbs On 3.96 (100.7) 4.27 (108.4) 19 Tripped 3.38 (85.8) 4.41 (112.0) Off 2.71 (68.8) 4.41 (112.0) 14 Reset 2.60 (66.0) 4.39 (111.5) 21 Dimensions in parentheses in millimeters. 0.69 (17.5) Wide Conductor with Ø 0.33 (8.3) Hole Line and Load End Figure 1. Type JG PVS 90 250A Outline 3

Line End 2.06 (52.4) 4.13 (104.8) 2.06 (52.4) 4.13 (104.8) 1.25 (31.8) 0.63 (15.9) 0.78 (19.8) 3.95 (100.4) R 0.19 (4.8) 3.95 (100.4) 0.91 (23.0) 2.56 7.00 5.50 (65.1) (177.8) (139.7) 3.06 (77.8) 4.13 (104.8) 2.08 (52.8) 7.00 (177.8) Load End 0.69 (17.5) 4.00 (101.6) 2.00 (50.8) Figure 2. Type JG PVS 90 250A Drilling Plans 4

Technical Data TD01211004E Time/current curves 10000 JG PVS circuit breaker time/current curves Equipped with type thermal-magnetic trip unit. For application and coordination purposes only. Based on cold start at rated ambient temperature. Connected with four feet of rated wire (90 C) per terminal with all poles wired in series. Tested in open air. 1000 Maximum Breaker Rating Rated Amperes (I n ) 90, 100, 125, 150, 175, 200, 225, 250, Instantaneous Trip Settings are for 700% of trip unit rating Instantaneous trip values are for single-pole 100 Interruption Rating (ka) Number of Poles in Series 600 Vdc 1 1.2 ka Note: For 150 250A ratings, instantaneous trip is above interruption rating. For application and coordination purposes only. Minimum 10 Time in Seconds 1 7x +20% 20% 0.1 Interruption rating determines end of curve 0.01 0.001 1 10 100 1000 10000 Current in Multiples of Rating (I n ) Figure 3. JG PVS Circuit Breakers Time/Current Curves 5

PVGard 1000 Vdc Technical data Table 4. Technical Data for PVGard 1000 Vdc Solar PV Circuit Breakers (100% and 80% Rated Frames) FD PV KD PV LG PV MDL PV Number of poles 4 4 4 3 Maximum voltage rating 1000 Vdc 1000 Vdc 1000 Vdc 1000 Vdc Maximum current rating 100A 350A 400A 600A Interrupting capacity at 1000 Vdc 3 ka 5 ka 5 ka 7.5 ka Time constant 1 ms 1 ms 1 ms 1 ms Ampere range 15 100A 125 350A 250 400A 300 600A Trip unit type Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Rated impulse withstand voltage Main conducting paths Auxiliary circuits 8 kv 4 kv 8 kv 4 kv 8 kv 4 kv 8 kv 4 kv Endurance Mechanical operations Electrical operations Maximum switching frequency 10,000 1000 300 per hour 10,000 400 240 per hour 8000 400 240 per hour 8000 400 240 per hour Third-party certification UL 489B UL 489B UL 489B UL 489B Environment Design ambient temperature Maximum current at 60 C, as % of rated current Maximum current at 70 C, as % of rated current Operating temperature range Storage temperature range Suitable for freeze temperatures to 40 C Relative humidity 50 C 91% 88% 20 C to +50 C 20 C to +70 C Option 0 to 95% noncondensing 50 C 91% 88% 20 C to +50 C 20 C to +70 C Option 0 to 95% noncondensing 50 C 93% 88% 20 C to +50 C 20 C to +70 C Option 0 to 95% noncondensing Suitable for reverse-feed applications Yes Yes Yes Yes Mounting permissible mounting position 50 C 93% 88% 20 C to +50 C 20 C to +70 C Option 0 to 95% noncondensing 90º 90º 90º 90º Connection diagrams Load Load (A) a b Terminations Al/Cu wire #6 300 kcmil (2) 3/0 250 kcmil (2) #2 500 kcmil (3) 3/0 400 kcmil Cu wire #4 4/0 (2) 3/0 250 kcmil (2) #2 500 kcmil (3) 3/0 300 kcmil Dimensions in inches (mm) Height Width Depth 6.00 (152.4) 5.50 (139.7) 3.38 (85.9) 10.13 (257.3) 7.22 (183.4) 4.09 (103.9) 10.13 (257.3) 7.22 (183.4) 4.09 (103.9) Weight in lbs 6 20 20 29 a Suitable for use on ungrounded systems, or grounded systems that have one end of load (A) connected to grounded terminal, opposite poles in series connection. b Suitable for use on ungrounded systems only. 16.00 (406.4) 8.25 (209.5) 4.06 (103.1) 6

Technical Data TD01211004E Dimensions FD PV four-pole breaker outlines and drilling plans Front View Side View 2.06 (52.4) 5.50 (139.7) 6X Ø 0.45 (11.43) Line End 1.03 0.75 0.47 (26.2) (19.1) (11.9) 3.50 (88.9) 3.39 (86.0) 3.19 (81.0) 1.41 (35.7) 4X R 0.16 (4.0) 0.27 (6.8) 2.72 (69.1) On Off 4.00 (101.6) 4.50 (114.3) 5.06 (128.6) 6.00 (152.4) On 14.9 Trip 6.2 1.77 (44.8) 3.63 (92.1) 0.27 (6.7) Off 4.3 Reset 6.5 A Pivot 4X Ø 0.197 (5.0) Hole Ø 0.328 (8.33) 1.938 (49.23) from Top Ø 0.344 (8.74) 0.656 (16.66) from Bottom for 0.164 32 (#8) x 1.500 (38.1) Mounting Screw 0.69 (17.5) Load End 3.19 (81.0) B 0.06 0.27 (1.6) (6.7) 1.00 (25.4) 0.37 (9.4) 0.50 (12.7) 0.19 (4.7) 0.75 (19.1) 0.08 (2.0) 0.74 (18.8) 1.56 (39.7) Dimensions Breaker Status A B Force, Lbs On 2.91 (74.0) 4.02 (102.0) 14 Tripped 2.57 (65.2) 4.07 (103.4) 4 Off 2.14 (54.4) 4.07 (103.4) 16 Reset 2.06 (52.2) 4.06 (103.1) 21 Dimensions in parentheses in millimeters. 0.50 (12.7) Wide Conductor with Ø 0.25 (5.35) Hole Load End Ø 0.219 (5.56) Hole Load End Figure 4. Type FD PV Four-Pole Outline 7

Drilling Plans Front Connected Front Cover Cutout Line End 2.75 (69.9) 0.69 (17.5) 6X Ø 0.16 (4.2) 32 Tap 1.19 (30.2) 0.60 (15.2) R 0.25 (6.4) 3.63 (92.1) 2.88 (73.0) 2.91 (73.8) 6.00 (152.4) 4.50 (114.3) 0.59 (15.1) 2.06 Load End (52.4) 5.50 (139.7) Figure 5. Type FD PV Four-Pole Drilling Plans 8

Technical Data TD01211004E KD PV four-pole breaker outlines and drilling plans Front View Side View 2.75 (69.9) 7.22 (183.4) Line End 0.84 0.62 (21.4) (15.9) 4.31 (109.6) 3.81 (96.9) 2.94 (74.6) R 0.19 (4.8) 2.81 (71.5) 0.50 (12.7) 5.77 (146.5) 7.41 (188.1) 1.25 (31.8) R 0.25 (6.4) 3.56 (90.5) On/I Off/O 2.39 (60.7) 4.00 (101.6) 0.25 (6.4) 8.44 (214.3) 8.88 (225.4) 10.12 (257.2) On 15.1 Tripped 5.6 Off 3.5 Reset 4.9 A 1.07 (27.1) Pivot R 0.19 (4.8) 4.78 (121.4) Dimensions for Extended Terminals and Barrier Style Numbers 4212B60G02, 4212B61G02 and 1492D24H01 1.16 0.94 (29.4) (23.8) 3.81 (96.9) 0.19 (4.8) 0.88 (22.2) 0.86 (21.8) 2.44 (61.9) 1.22 (31.0) 0.44 (11.1) Load End 6X Ø 0.28 (7.1) Mounting Holes Ø 0.50 (12.7) 2.88 (73.0) from Top, Load End Ø 0.50 (12.7) 2.63 (66.7) from Top, Line End Ø 0.44 (11.1) 0.75 (19.1) from Bottom Both Ends for 0.25 20 x 1.50 (38.1) Mounting Screws 2.38 (60.3) Breaker Status Dimensions A On 5.40 (137.1) 4.79 (121.6) 30 Tripped 4.77 (121.2) 4.91 (124.7) Off 4.16 (105.7) 4.93 (125.2) 25 Reset 4.07 (103.4) 4.92 (125.0) 35 Dimensions in parentheses in millimeters. B 4.06 (103.2) B 0.47 (11.9) 0.6 (1.6) Force, Lbs 0.77 (19.5) 1.06 (27.0) 0.75 (19.1) Wide Conductor with Ø 0.39 (9.9) Hole Line and Load End Figure 6. Type KD PV Four-Pole Outline 9

Front Connected Terminals Front Cover Cutout Line End 3.44 (87.3) 0.86 (21.8) 6X Ø 0.25 (6.4) 20 Tap 1.31 (33.3) 2.63 (66.7) R 0.34 (8.7) 5.77 (146.5) 4.92 (125.0) 3.75 (95.3) 10.12 (257.2) 8.44 (214.3) 1.64 (41.7) R 0.19 (4.8) 0.83 (21.0) 1.25 (31.8) 2.75 (69.8) Load End 7.22 (183.4) 2.39 (60.7) 4.78 (121.5) Figure 7. Type KD PV Four-Pole Drilling Plans 10

Technical Data TD01211004E LG PV four-pole breaker outlines and drilling plans Front View Side View 7.22 (183.4) 2.75 (69.9) Line End 1.75 0.84 0.63 (44.5) (21.4) (15.9) 4.31 (109.4) 4.06 (103.2) 3.72 (94.4) R 0.25 (6.4) 7.28 (184.9) 3.04 (77.1) 1.59 (40.4) 8.44 (214.4) 7.23 (183.7) 8.88 (225.4) 10.13 (257.2) On 17.4 Tripped 5.0 Reset 18.0 Off 14.2 A 2.17 (55.2) 0.44 (11.1) 5.58 (141.7) Pivot Dimensions for Extended Terminals and Barrier Style Number 69D4557 1.19 2.13 (54.0) (30.2) 0.86 (21.8) 1.18 (23.0) 2.31 (58.6) Ø 0.44 (11.1) 1.15 (29.3) 0.59 (15.0) Load End 6X Ø 0.22 (5.5) Mounting Holes Ø 0.44 (11.1) 0.55 (13.9) from Top, Load End Ø 0.44 (11.1) 0.62 (15.9) from Top, Line End Ø 0.21 (5.3) 0.50 (12.7) from Bottom Both Ends for M5 x 0.8 x 100 mm Mounting Screws 4.06 (103.2) B Section A-A 0.41 (10.3) 0.06 (1.6) 3.98 (101.2) 0.13 (3.2) 0.85 (21.5) 1.34 (34.1) 2.38 (60.3) 0.97 (24.6) Wide Conductor with Ø 0.52 (13.1) Hole Line and Load End Breaker Status Dimensions A On 5.32 (135.1) 5.34 (135.6) 44 Tripped 4.62 (117.4) 5.43 (137.9) Off 3.55 (90.0) 5.27 (133.9) 56 Reset 3.34 (84.9) 5.20 (132.1) 45 Dimensions in parentheses in millimeters. B Force, Lbs Figure 8. Type LG PV Four-Pole Outline 11

Line End 3.44 (87.3) 0.86 (21.8) 6X M5 X 0.8 2.70 (68.6) 1.35 (34.3) 5.58 (141.7) 4.73 (120.2) R 0.28 (7.0) 10.13 (257.2) 8.44 (214.3) 1.64 (41.7) 1.33 (33.9) 3.34 (84.8) 1.58 (40.2) Load End 2.75 (69.9) 7.22 (183.4) 7.06 (179.3) 2.67 (67.8) Figure 9. Type LG PV Four-Pole Drilling Plan 12

Technical Data TD01211004E MDL PV three-pole breaker outlines and drilling plans 4.13 (104.8) 2.75 (69.9) 8.25 (209.6) 2.75 (69.9) 0.63 (15.9) Line End 4.38 (111.1) 4.06 (103.2) 6.44 (163.6) 1.19 (30.2) R 0.25 (6.4) 14.75 (374.7) 8.30 (210.9) 10.59 (269.1) R 0.19 (4.8) 3.09 (78.6) 1.50 (38.1) 1.92 (48.7) On/I On/I Off/O Off/O 3.64 (92.5) 7.28 (184.9) 16.00 (406.4) On 14.7 Tripped 0.2 Off 19.2 Reset 24.2 A 2.05 (51.9) Pivot 1.19 (30.2) 4X Ø 0.38 (9.5) Mounting Holes Ø 0.74 (18.7) 3.33 (84.6) from Top Ø 0.59 (15.1) 0.36 (9.1) from Bottom for 0.31 (7.9) 16 x 1.75 (44.5) Mounting Screws 4.06 (103.2) B Section A-A 0.06 (1.6) 4.06 (103.2) 4.00 (101.6) 3.72 (94.4) 1.63 (41.3) 3.25 (82.6) 1.63 (41.3) 0.81 (20.6) 0.50 0.31 (12.7) (7.9) Load End Breaker Status Dimensions A On 8.74 (222.0) 5.34 (135.6) 49 Tripped 7.88 (200.2) 5.50 (139.6) Off 6.72 (170.8) 5.36 (136.2) 52 Reset 6.44 (163.5) 5.27 (133.7) 64 Dimensions in parentheses in millimeters. B Force, Lbs 1.87 (47.6) 1.88 (47.6) Wide Conductor with Ø 0.42 (10.6) Hole Line and Load End 0.53 (13.5) Figure 10. Type MDL PV Three-Pole Outline 13

Line End 2.75 (69.9) 4X Ø 0.31 (7.9) 3.44 (87.3) 8.30 (210.9) 7.68 (195.0) R 0.25 (6.4) 16.00 (406.4) 14.75 (374.7) 2.29 (58.2) R 0.19 (4.8) 1.33 (33.7) 3.28 (83.3) 1.50 (38.1) Load End 4.13 (104.8) 8.25 (209.6) 3.64 (92.5) 7.28 (184.9) Figure 11. Type MDL PV Three-Pole Drilling Plans 14

Technical Data TD01211004E Time/current curves 10,000 KD PV circuit breaker time/current curves Equipped with type thermal-magnetic trip unit. 1000 100 Maximum For application and coordination purposes only. Based on cold start at rated ambient temperature. Connected with four feet of rated wire (90 C) per terminal with all poles wired in series. Tested in open air. Breaker Rating Rated Amperes (I n ) 125, 150, 175, 200, 225, 250, 300, 350 Interruption Rating (ka) Number of Poles in Series 1000 Vdc 4 5 ka Instantaneous Trip Settings are for 700% of trip unit rating Instantaneous trip values are for single-pole Minimum 10 Time in Seconds 1.000 7x +20% 20% 0.100 Interruption rating determines end of curve 0.010 0.001 100 1,000 10,000 100,000 1,000,000 Current in Percent of Breaker Trip Unit Rating (I n ) Figure 12. KD PV Circuit Breakers Time/Current Curves 15

10,000 LG PV circuit breaker time/current curves Equipped with type thermal-magnetic trip unit. For application and coordination purposes only. Based on cold start at rated ambient temperature. Connected with four feet of rated wire (90 C) per terminal with all poles wired in series. Tested in open air. 1000 Breaker Rating Rated Amperes (I n ) 250, 300, 350, 400 Instantaneous Trip Settings are for 700% of trip unit rating Instantaneous trip values are for single-pole 100 Interruption Rating (ka) Number of Poles in Series 1000 Vdc 4 5 ka Maximum Minimum 10 Time in Seconds 1.000 7x +20% 20% 0.100 Interruption rating determines end of curve 0.010 0.001 1 10 100 1000 10,000 Current in Multiples of Rating (I n ) Figure 13. LG PV Circuit Breakers Time/Current Curves 16

Technical Data TD01211004E 10,000 MDL PV circuit breaker time/current curves Equipped with type thermal-magnetic trip unit. For application and coordination purposes only. Based on cold start at rated ambient temperature. Connected with four feet of rated wire (90 C) per terminal with all poles wired in series. Tested in open air. 1000 Breaker Rating Rated Amperes (I n ) 300, 350, 400, 450, 500, 600 Instantaneous Trip Settings are for 700% of trip unit rating Instantaneous trip values are for single-pole Maximum Interruption Rating (ka) Number of Poles in Series 1000 Vdc 3 7.5 ka 100 Minimum 10 Time in Seconds 1 0.1 7x +20% 20% Interruption rating determines end of curve 0.01 0.001 100 1000 10,000 100,000 Current in Percent of Breaker Trip Unit Rating (I n ) Figure 14. Type MDL PV Circuit Breakers Time/Current Curves 17

18

Technical Data TD01211004E 19

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2014 Eaton All Rights Reserved Printed in USA Publication No. TD01211004E / Z14800 February 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners.