INTAKE FILTERS and FILTER SILENCERS

Similar documents
Lateral Access Filter Silencer LQB Series 3 MPT 12 Flange

Absorptive Silencers UNIVERSAL. Absorptive Silencers ENERGY ENVIRONMENTAL

TECHNICAL DATA. Replacement Elements. Standard Replacement Elements. Solberg Replacement Elements

INLET FILTER ASSEMBLIES/ EXPOSED FILTERS

INLET FILTER SILENCERS/ SILENCERS

Industrial Filters UNIVERSAL. Industrial Filters & Filter/Silencers ENERGY ENVIRONMENTAL

50 HERTZ METRIC BLOWER

Miniature Filter Silencers FS Series ¼ 1 MPT

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

H.S. MACHINERY RING COMPRESSORS

Compact Heavy Duty Oil Mist Exhaust Filters "HDL" Series 1" - 2 1/2" FPT

OPERATING AND MAINTENANCE MANUAL BATCH PRESSURE FILTER 3 GALLON CAPACITY

High Performance Fan Coils FCHG Genesis Series Horizontal

Inlet Filter Silencers/ Silencers

where nature and technology meet FILTRATION Solutions for filtration applications PETROGAS GAS-SYSTEMS BV

Vent/Fan Silencers UNIVERSAL. Vent/Fan Silencers ENERGY ENVIRONMENTAL

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

COMPRESSED AIR FILTERS

Dimensions: 48 Wide x 96 Long x 88 Tall (with exhaust stack), 1,445 pounds

Air Boss Model M3000. Industrial Air Cleaner READ AND SAVE THESE INSTRUCTIONS. TRION

Design and Application Details

Process Inline Filter Protective filter PLF2-9HF

HIGH PERFORMANCE FILTERS INDUSTRIAL HYDRAULIC AND LUBRICATION APPLICATIONS

SUPERHONE Installation * Operation * Maintenance * Replacement Parts

CA3000C & CA6000C Cartridge Air Cleaners

The Technology of Modern Filtration Filters Designed and Built for Today s Industries

Blower Silencers. Technical Literature. UCI/UCIY/UCIA Series Page 4 RIS/RISY/RISH Series Page 5. Discharge Silencers

LINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited.

Design and Application Details

Model Model Model

Completing Your Fume Removal System

WARCO CHEMAG SERIES GH FILTERS

RP-CS 2-98 CERTA-SEAL LIQUID BAG FILTERS WITH THE MATCHED PERFORMANCE DESIGN. Products

Design and Application Details

Compressed Air Filters

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

ISO 5011 Tested to Make Sure You Maximize Airflow While Still Protecting Your Engine.

NEW PRODUCT SELECTION GUIDE

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

IFP S.A.E. 4 BOLT FLANGE FITTINGS

Process screen basket filter PRFS

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

CAUTION: NOT INTENDED FOR STREET USE HOW TO USE THIS CATALOG WE LOVE RACING

MICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL. MX3510 Includes Installation, Operation, and Service Instructions CAUTION

ISO 5011 Tested to Make Sure You Maximize Airflow While Still Protecting Your Engine.

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

Complete HVAC Capability

SOLBERG. Vacuum Filters Maintenance Manual CSL, CT, VS, VL, SM-CT, CSS, and CBL Series Metric Version

Service Access Cover. Vacuator Valve. Accessories

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

Blue Line. Wet/Dry Vacuums - for safer, cleaner and more productive job sites & facilities

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

Horizontal downflow pleated cartridge dust collector

to obtain the specified voids due

WE GUIDE AIR LOUVERS

Networking: Wall-Mount Cabinets PROTEK Wall-Mount and Double-Hinge Cabinets PROTEK Single-Door Fan and Filter Thermal Packages, UL and NEMA Type 1

Vacuum Accessories. Pneumatic. Section E. Pneumatic. Parker Hannifin Corporation Pneumatic Division Richland, Michigan

Square Inline Fans with Multi-Directional Discharge

Automatic filter AF 172 G

Actions Required to Avoid Repeat Turbocharger Failures

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

BGT Series. Low Pressure Filters

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

Oil Solutions. TTF/BGTS Series Return In-Tank Filters. Global Filtration Technology. Filtration.

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Automatic filter AF 173 G

ENGINEERED PRODUCTS. Project: Unit Tag: MS-80-D-3 Page 1 of 5

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Process Inline Filter Medium / High Pressure PFM / PFH

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

For Residential and Light Commercial Applications

Demand Better From Your Cartridge Dust Collector By Gary Berwick, P.Eng. Quality Air Management Corp. Published November, 2006

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

DIR. VARIZON Displacement unit with adjustable spread pattern. Quick guide

MANN+HUMMEL IQORON The new compact air cleaner for high requirements

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

GRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

VHIA High-Static Ducted Indoor Units - 60HZ

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

MCF DUST FILTERS. Most Energy Efficient Cleaning Mechanism on the Market.

PANEL FILTER PREFILTER MSKP T. Replacement for 1 x 8258

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

TTF/BGTS Series. Return In-Tank Filters. Global Filtration Technology

P a c k a g e s. One step ahead. Energy-efficient Reliable Compact Quiet

MODEL NUMBER NOMENCLATURE. The model described above is a Side Access Housing, 4,000 CFM, 2 stages PX1224 cells, epoxy coated construction.

Ducting & Ventilation Components

Innovation in Filtration. The new generation of filter elements e

VFC-5 to VFC-500 FLO-COATER

Multistage Centrifugal Blowers/ Exhausters

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

OIL BATH INTAKE AIR FILTERS. Capacities up to 6500 CFM

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS

Downflo. Oval Dust Collectors POWERED BY

series RVV Variable flow rate controllers

TURBO PRESSURE BLOWERS

Transcription:

Bulletin FA Stoddard Silencers Stoddard Silencers of Canada Inc. 91 Brimley Rd. Unit 1, Scarborough, Ontario, Canada M1J 1A Telephone () 291-390 FAX () 291-91 E-Mail - info@stoddardsilencers.com Web page - www.stoddardsilencers.com INTAKE FILTERS and FILTER SILENCERS

F6 Air Intake Filters and Filter Silencers Air Intake Filter and Filter Silencer The Series F6 Air Intake Filter and Filter Silencer is designed to mount directly on the inlet of an engine, blower or compressor. It will provide db to db noise reduction and the paper filter media has an efficiency of 99% on 1 micron particles. SERVICE LIFE & CLEANING: The service life of the element is dependent upon the surrounding environment and cannot be predicted. To prevent COLLAPSING of the filter element, STODDARD SILENCERS recommends the differential pressure across the filter element NOT exceed 1 inches of water column. Positive indication that the element requires cleaning or replacement can be provided with STODDARD SILENCERS model A0- Pressure Drop Indicator, at an extra charge. To extend service life, rap element gently to dislodge accumulated dirt. An alternate method is to direct compressed air ( PSIG max) through the element opposite to the direction of air flow. THE FILTER ELEMENT MUST EVEN- TUALLY BE REPLACED. ALTERNATE FILTRATION MEDIA AVAILABLE FOR F6 REFER TO PAGE FOUR Pre-Filter wrap available at added cost Consult Factory (90% on micron particles and larger) 30 Typical Attenuation Curve TYPICAL ATTENUATION - db F6 shown with optional A0- Pressure Drop Indicator. 0 63 12 20 00 1K 2K K K K OCTAVE BAND CENTER FREQUENCY (Hz) F6 Series Model A Connection Size B C D Rated CFM Wt. Replacement Element Number F6-1 11" 1 2 NPT 3 9 F- B F6-1 1 2 11 1 2" NPT 0 9 F- F6-2 12" 1 2 NPT 13 F- F6-2 1 2 12 1 2" NPT 10 F- C F6-3 13" 1 2 NPT 2 F-9 D F6-1" 1 2 NPT F-9 F6- " NPT/FLG 0 23 F-9 F6-6 " 1 2 Flange 123 0 F-1 F6-1" 1 2 Flange 13 212 0 F-111 A Connection Size F6- F6-12 F6-1 " 1 2 Flange 12" 1 2 Flange 1" 1 2 Flange 1 1 2 1 1 2 1 1 2 333 6 6 9 0 11 F-13 F-13 F-13 Sizes ", 12" and 1" are FILTERS only 2

Air Intake Filters and Filter Silencers F2 Air Intake Filter and Filter Silencer The Series F2 Air Intake Filter and Filter Silencer is designed to mount directly on the inlet of an engine, blower or compressor. It will provide db to db noise reduction. The Polyurethane filter media has an efficiency of 9% on micron particles and a stainless steel center core. SERVICE LIFE & CLEANING: The service life of the element is dependent upon the surrounding environment and cannot be predicted. To prevent COLLAPSING of the filter element, STODDARD SILENCERS recommends the differential pressure across the filter element NOT exceed 1 inches of water column. Positive indication that the element requires cleaning or replacement can be provided with STODDARD SILENCERS model A0- Pressure Drop Indicator, at an extra charge. Wash in sink or large pan using either water and any good washday type detergent and rinse clean. Squeeze out filter by pressing it against metal grid. Let stand and allow to dry completely. Pre-Filter wrap available at added cost Consult Factory (90% on micron particles and larger) 30 Typical Attenuation Curve TYPICAL ATTENUATION - db 0 63 12 20 00 1K 2K K K K OCTAVE BAND CENTER FREQUENCY (Hz) F2 shown with optional A0- Pressure Drop Indicator. F2 Series Model A Connection Size B C D Rated CFM Wt. Replacement Element Number F2-1 F2-1 1 2 11" 1 2 NPT 11 1 2" NPT 3 0 9 9 F-119 F-119 B F2-2 12" 1 2 NPT 13 F-119 F2-2 1 2 12 1 2" NPT 10 F-119 F2-3 13" 1 2 NPT 2 F-1 C F2-1" 1 2 NPT F-1 D F2-1" 1 2 NPT/FLG 0 23 F-1 F2-6 6" 1 2 Flange 123 0 F-121 F2-1" 1 2 Flange 13 212 0 F-122 F2- F2-12 F2-1 " 1 2 Flange 12" 1 2 Flange 1" 1 2 Flange 1 1 2 1 1 2 1 1 2 333 6 6 9 0 11 F-123 F-123 F-123 A Connection Size Sizes ", 12" and 1" are FILTERS only 3

Standard Filter Elements F6 Intake Filter Silencer F2 Intake Filter Silencer Paper Elements (Replaceable) Efficiency: 99% on 1 micron particles and larger Element # Housing Size F- 1" to 2 1 2" F-9 3" to " F-1 6" F-111 " F-13 " to 1" Polyurethane Elements (Washable) Efficiency: 9% on micron particles and larger Element # Housing Size F-119 1" to 2 1 2" F-1 3" to " F-121 6" F-122 " F-123 " to 1" Alternate Elements for F6 Polyester Felt Elements (Washable) Efficiency: 99% on 3 micron particles and larger Element # Housing Size F-11 1" to 2 1 2" F-13 3" to " F-13 6" F-139 " F-1 " to 1" Epoxy Coated Wire Mesh Elements (Washable) Efficiency: 90% on micron particles and larger Element # Housing Size F-129 1" to 2 1 2" F-130 3" to " F-131 6" F-132 " F-12 " to 1" Stoddard Silencers Stoddard Silencers of Canada Inc. 91 Brimley Rd. Unit 1, Scarborough, Ontario, Canada M1J 1A Telephone () 291-390 FAX () 291-91 E-Mail - info@stoddardsilencers.com Web page - www.stoddardsilencers.com LC-200-2/0

Bulletin F-6 Stoddard Silencers Stoddard Silencers of Canada Inc. 91 Brimley Rd. Unit 1, Scarborough, Ontario Canada M1J 1A Telephone () 291-390 FAX () 291-91 E-Mail - info@stoddardsilencers.com Web page - www.stoddardsilencers.com INLINE AIR FILTERS

F6 INLINE AIR FILTERS INLINE AIR FILTERS - PRESSURE SERVICE The Series F6 Inline Air Filter is designed to mount directly in the air piping system for engines, blowers or compressors. The filter element, which is fabricated from pleated paper media, has an efficiency of 99% on 1 micron particles and larger. The housing is designed to withstand an internal pressure of 1 psig. Pressure taps are provided on the intake and discharge nozzles for installation of a pressure drop indicator or switch by the customer. The F6 Inline Air Filter surfaces are prime coated with a primer. ALTERNATE FILTRATION MEDIA AVAILABLE FOR F6 Cleanable Polyurethane Foam - 9% on micron particles Cleanable Polyester Felt - 9% on 3 micron particles Epoxy Coated Wire Mesh - 90% on micron particles (When Oil Wetted) FOR VACUUM SERVICE USE F6V (See Page 3) F6 SERIES REPLACEMENT MODEL A B C E H RATED WEIGHT ELEMENT CFM (1) NUMBER F6-2 2 NPT 12 3 / 9 13 3 F- F6-2 1 / 2 2 1 / 2 NPT 12 3 / 9 10 0 F- F6-3 3 NPT 1 1 / 11 2 0 F-9 F6- * FLG 1 1 / 11 F-9 F6- * FLG 1 1 / 11 0 0 F-9 F6-6 *6 FLG 1 1 / 12 0 F-1 F6- * FLG 2 19 1 / 2 1 100 10 F-111 F6- * FLG 36 3 22 1 333 390 F-13 F6-12 *12 FLG 36 3 22 1 6 1 F-13 F6-1 *1 FLG 36 3 22 1 6 3 F-13 *Flanges match 12# ASA. Diameter and Drilling. (1) Rated capacity is based upon a maximum exit velocity of 00 fpm. 2

INLINE AIR FILTERS F6V INLINE AIR FILTERS - VACUUM SERVICE ONLY The Series F6V Inline Air Filter is designed to mount directly in the air piping system for engines, blowers or compressors. The filter element, which is fabricated from pleated paper media, has an efficiency of 99% on 1 micron particles and larger. The housing is designed to withstand a full vacuum. Pressure taps are provided on the intake and discharge nozzles for installation of a pressure drop indicator or switch by the customer. The F6V Inline Air Filter surfaces are prime coated with a red oxide primer. ALTERNATE FILTRATION MEDIA AVAILABLE FOR F6V Cleanable Polyurethane Foam - 9% on micron particles Cleanable Polyester Felt - 9% on 3 micron particles Epoxy Coated Wire Mesh - 90% on micron particles (When Oil Wetted) FOR PRESSURE SERVICE USE F6 (See Page 2) Wing Stud Flat Head Retainer Gasket Receptacle Rolled Angle F6 Shell F6V up to and including size: Coarse threaded wing studs allow for easy access to the F6V for servicing the filter elements. See diagram at left. F6V SERIES REPLACEMENT MODEL A B C E H RATED WEIGHT ELEMENT CFM (1) NUMBER F6V-2 2 NPT 12 3 / 9 13 3 F- F6V-2 1 / 2 2 1 / 2 NPT 12 3 / 9 10 0 F- F6V-3 3 NPT 1 1 / 11 2 0 F-9 F6V- * FLG 1 1 / 11 F-9 F6V- * FLG 1 1 / 11 0 0 F-9 F6V-6 *6 FLG 1 1 / 12 0 F-1 F6V- * FLG 2 19 1 / 2 1 100 10 F-111 *Flanges match 12# ASA. Diameter and Drilling. (1) Rated capacity is based upon a maximum exit velocity of 00 fpm. 3

F INLINE AIR FILTERS INLINE AIR FILTERS - VACUUM SERVICE ONLY The series F Inline Filter is a cost-effective alternative to the F6 Series Inline Filter. The F is designed to be mounted in the inlet piping or vacuum system piping for vacuum blowers, engines or compressors. The housing is rated to inches Hg vacuum. The filtering element is polyurethane foam with a stainless steel center core. The filter removes 9% of all particles micron size or larger. The F Inline Air Filter surfaces are painted with a gray machinery enamel finish. Flow Replacement Element F SERIES REPLACEMENT MODEL A B C D H WEIGHT ELEMENT NUMBER F-2 2 NPT 11 1 / / 1 / 1 F-0 F-2 1 / 2 2 1 / 2 NPT 11 1 / / 1 / F-0 F-3 3 NPT 11 1 / / 1 / F-0 F- NPT 12 11 1 / 3 / 1 / F-0 Stoddard Silencers Stoddard Silencers of Canada Inc. 91 Brimley Rd Unit 1, Scarborough, Ontario, Canada M1J 1A Telephone () 291-390 FAX () 291-91 E-Mail - info @ stoddardsilencers.com Web page - www.stoddardsilencers.com LC-200-2/0.