Owner s Manual. Features

Similar documents
Owners Manual. Features

Owners Manual. Features

Installation and Operating Instructions

Installation and Operating Instructions

MODEL 422 Submersible Pump Controller

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

INSTALLATION INSTRUCTIONS FOR SYMCOM MODEL 231-P-INSIDER

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

All products subject to this warranty must be returned for examination, repair or replacement to:

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

MODEL 233P/111P/233P-1.5

Pump Installation and Service Manual HRS Hydromatic Retractable System

Powerful & Intelligent Submersible Pumps

Four-Position Gang Charger for SAFEMTX Li-ION Battery Packs

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

ODY-19-1 AIR PRESSURE GAUGE

HLY-1111 HEAD TEMPERATURE GAUGE

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

ESC Series Engine Shutdown Control

PH21/27 POWERHOUSE Dual Generator Parallel Kit Operating Instructions

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

VCPR. A Portable Device for Remotely Racking VCP-W Circuit Breakers. User s Manual

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

VCPR. User s Manual. MarTek Ltd. RAKTEK. Model VCPR. A Portable Device for Remotely Racking VCP-Style Circuit Breakers 1.0 Arc-blast Hazards

The Da-Lite Difference.

P30L User Manual Revision 2.0. P30L LCD 30A Solar Charge Controller CHC-LCD-30. User s Manual

2SHE Series Direct-Drive Shutter Fans

15100 Module Installation Guide Mercedes EPA07 w/dpf

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Duplex Booster System Instruction Manual

DC Distribution Panel User Guide # S

FHC-1D user manual. Features

II DISTRIBUTION & SUBSTATION TYPE C

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Electronic Products ELECTRONIC MAINTENANCE

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

SUNTURA SOLAR TRACKER

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Filtered PWM Speed Control for Permanent Magnet DC Motors

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

ODY-10-1 rev. B FUEL PRESSURE GAUGE

Internal MAP Water/Methanol Injection Controller ,

Installation Instructions

EMISSION CONTROL WARRANTY STATEMENT

30100 Module Installation Guide L

DSR1. User s Manual. MarTek Ltd. RAKTEK. Model DSR1. A Portable Device for Remotely Racking DS and DSII-Style Circuit Breakers. 1.0 Arc-blast Hazards

SPC-PANEL Simplex, Single Phase Pump Control Panel

3/4 Ton Heavy Duty Wheel Dolly

Users Guide for Ac-sync

Installation Instructions

SUNTURA HD SOLAR TRACKER

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

Grid Tied Limiter User Manual

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

Installation Instructions

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

CRD610 Automatic Fitting Inserter

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

CHC-1224-xx User Manual Revision 1.0. windynation. Solar Panel Charge Controller CHC CHC User s Manual

Installation Instructions

Volume CHARGESTORM AB. Charging station model EVA Start and Protected. User Manual Start & Protected

Hydraulic Transmission Jacks

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

INSTRUCTION and OPERATIONS MANUAL. for

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

Tissue Master. User Manual

Pirate Loot Operation Manual

SOLAR DASH CHARGING SYSTEM USER GUIDE

INSTALLATION & OWNER'S MANUAL

PH550 Parts Cart. Distributed by Torin Jacks, Inc E. Brickell St. Ontario, CA USA

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

The Da-Lite Difference.

Intelligent Charging System. User Manual PB-80C24

FK75 / FK95 Quick Installation Guide

Lint Slide Grid Moist Air Applicator

ATD Amp Carbon Pile Battery Tester User s Manual WARNING

TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Volume CHARGESTORM AB. Charging station model EVA Connected. User Manual Connected

Model Railroad Circuit Breaker (CB-1)

Installation Instructions

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

"WHERE TUBING AND FITTINGS COME TOGETHER"

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

ADVANCED PID TROUBLESHOOTING

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

ESE Series Cast Iron Sewage Pumps

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Generator Start Control Module

Installation Instructions

600 Amp Battery Jumper with Air Compressor

Transcription:

Owner s Manual Pumptec is a microcomputer based pump protection device that continuously monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks, and abnormal line voltage conditions. Indicator lights provide complete system status, which can be easily viewed without removing the cover. Pumptec interrupts power to the motor whenever the motor load drops below a preset level or the load drops quickly. Pumptec is optimized to work with Franklin 2- & 3-wire single phase motors from 1/3 to 1.5 HP. An underload (dry well) adjustment is provided to address unusual situations. Features Protection Features Dry Well (Underload) Over & Under Voltage Rapid Cycle Bound Pump Indicator Lights Load Voltage Status Remote Control Features Over & Underload Settings Over & Under Voltage Settings Reset Time Settings Fault History (Last 15 Faults) System Status Monitor Other Features Heavy Duty Relay 115V/230V 50/60Hz Operation Alarm Circuit Contacts

Technical Specifications: Model Number 5800020600 Horsepower Rating 1/3 to 1.5 Voltage Rating 115V/230V Frequency 50/60Hz Power Consumption 4W Response Time 3 Seconds Reset Time 2 to 120. (240. w/remote) Type Single-Phase Induction Run Alarm Contact Rating 1 Amp 115V/230V Over/Under Voltage Time-out 2 utes Operating Temperature Range -15 ºF to 130 ºF Note: Pumptec is not designed for use on permanent split capacitor (PSC) motors. Dry well protection occurs when pump suction is broken. Deadhead conditions may not always be detected due to variation in pump load characteristics Installation Instructions 1. Remove the cover from the Pumptec. 2. If you will be running a 1.5 HP motor, move the circuit board jumper to the 1.5 HP position as shown in Figure 1. More Sensitive 70% 60% 80% 90% 40% Underload Trip %SFL 30 60 15 120 2 Timeout 1/3 HP 1 HP Setting (Factory default) 1.5 HP Setting Figure 1: Circuit board jumper for 1.5 HP motors 2

3. Mount the unit in a location convenient for wiring. 4. Turn off power at the AC source. 5. Pumptec may be wired upstream or downstream of the control switch for 2-wire and 3-wire motors. Select an installation option from Figures 2A and 2B. 6. Connect wires to the Pumptec as shown in Figure 3. Power is connected the same way regardless of the line voltage. Pumptec Control Switch Pump Control Switch Pumptec Pump Figure 2A: 2-Wire Installation Options Pumptec Control Switch Control Box Pump Control Switch Pumptec Control Box Pump Figure 2B: 3-Wire Installation Options 3

Alarm Contacts Alarm Alarm (1 A Max.) 115V or 230V From power source or control switch Figure 3: Wiring Connections To 2-wire or 3-wire control box 7. Set the time-out adjustment to the desired position. The factory setting is 30 utes (See Figure 4)*. More Sensitive 60% 40% 70% 80% 90% Underload Trip %SFL Underload sensitivity (Full clockwise for remote) Factory setting = 70% 15 2 30 Timeout 60 120 Reset time adjustment (Full clockwise for remote) Factory setting = 30 utes Figure 4: Time-out and Trip Sensitivity Settings 8. The factory underload setting of 70% should not require any adjustment. 9. Wire in alarm circuit, if desired. 4

10. Replace cover and secure cover screw. 11. Turn AC power back on. *Note: If you will be using IR remote control to set the underload and the time-out settings, set the appropriate adjustment knobs to the Remote position (fully clockwise position). See Figure 4. The initial remote settings are the same as the factory presets - 70% for underload and 30 utes for the underload timeout. The underload adjustment is preset at the factory to detect underload (dry well) conditions on most systems. In general, there is no need to adjust this setting. 5

Operation Pumptec has three indicator lights labeled POWER, LOAD and VOLTAGE. If the Pumptec is connected upstream of the pressure switch, the system status can be detered from these indicator lights at any time. When wired downstream of the control switch, no status will be displayed when the control switch is open. Power Indicator Light If solid, the Pumptec has power and the system is idle. In this state, the motor is not running and the Pumptec is waiting for the control device (i.e. pressure switch) to close and turn on the motor. When flashing, the system is pumping water and running normally. Yellow Load Indicator Light The yellow load light indicates one of three conditions: 1. A solid yellow light with no flicker indicates a dry well (underload). This is caused by the load of the motor going below the underload adjustment knob. (If you have a Pumptec remote control, this will be indicated by underload in the Pumptec Fault History.) 2. A solid yellow light with a slight flicker indicates an underload caused by a rapid decrease in load (approximately 25% over a twenty second period). (If you have a Pumptec remote control, this will be indicated by underload* in the Pumptec Fault History.) Note: In both conditions above, the Pumptec will wait until the reset time-out period has ended before attempting to restart the motor. 3. A flashing yellow light (on for 1/2 second, off for 1/2 second) indicates an overload caused by the motor current being excessively high. The unit must be manually reset by removing power for 10 seconds. (If you have a Pumptec remote control, this will be indicated by overload in the Pumptec Fault History.) Voltage Indicator Light When the voltage light is solid, an under voltage condition has been detected. The under voltage trip is factory preset to 203 volts. The remote control feature may be used to alter the under voltage trip point. When the voltage light is flashing, an over voltage fault has been detected. The over voltage trip is factory preset to 253 volts. The remote control feature may be used to alter the over voltage trip point. After a voltage fault has occurred, Pumptec will check the line voltage every two utes and will reset when the line voltage returns to the normal range. Load & Voltage Indicator Lights Flashing When both the load and voltage indicator lights are flashing together, 6

a Rapid Cycle condition has occurred. The Pumptec will wait the duration of the reset time-out period (either the factory preset time (30 utes) or the time set using the underload time-out adjustment knob by the user) before attempting to restart the motor. *Note: The Rapid Cycle trip criteria is 4 starts per ute. The Pumptec must be wired before the pressure switch to activate the Rapid Cycle feature. Troubleshooting Remote Control A Pocket PC with an infrared port may be used to monitor the motor/pump system performance and adjust the Pumptec trip points. When dealing with unusual installations, the system monitor and underload adjustment remote control features allow quick diagnosis of system problems. No Lights No power is applied to the Pumptec. Check for voltage at the and connections. If Pumptec is wired downstream of the control switch, the control switch may be open. Solid Load Light Pumptec has detected a dry well or underload condition. A. Make sure the pump and motor are matched correctly. B. Check for a blocked pump intake or stuck check valve. C. The coupling between the motor & pump may be stripped. D. Blocked plumbing or stuck check valve may be causing a deadhead condition. E. The underload sensitivity knob may be adjusted in cases where the unit is too sensitive. After adjustment, check to ensure the unit still is able to detect a dry well condition. Flashing Load Light The system is drawing excessive current. A. The motor is stalled or there is a ground fault. Solid or Flashing Voltage Light The line voltage is too high or too low. A. An unloaded generator can cause a high line condition. B. Low line conditions can be caused by loose connections. C. Report persistent high or low line voltages to the power company. Flashing Voltage & Load Lights Rapid Cycle condition has occurred. A. Check for a waterlogged pressure tank. B. A bobbing float switch may cause rapid cycling. 7

Limited Warranty Franklin Electric warrants to its direct customers and Franklin Electric Authorized Shops that each Pumptec unit sold will be free from defects in workmanship and materials and will perform consistent with samples previously supplied for a period of one year from the date of installation but not more than two years from the date of manufacture in water well applications. THE WARRANTY STATED IN THIS PARAGRAPH IS IN LIEU OF ALL OTHER WARRANTIES (EXCEPT OF TITLE), WRITTEN, ORAL, STATUTORY, EXPRESSED OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE. Any Pumptec unit which fails to conform to the contract of sale, including the above warranty, will be repaired or replaced at the option of Franklin Electric. The remedy of repair or replacement is the sole and exclusive remedy afforded for breach of the above warranty or for breach of expressed or implied warranties arising under state law. Warranty on repaired or replaced equipment will be for the time remaining under the terms of the original warranty. Under no circumstances shall Franklin Electric be liable for any special, incidental or consequential economic damages resulting from the failure of Franklin Electric to comply with the contract of sale, breach of the above warranty or for breach of any expressed or implied warranty under state law, negligence or otherwise. TOLL-FREE HELP FROM A FRIEND Phone Franklin s toll-free Submersible Service Hotline for answers to your installation questions. When you call, a Franklin expert will offer assistance in troubleshooting your pump protection system and provide immediate answers to your motor application questions. FRANKLIN ELECTRIC SUBMERSIBLE SERVICE HOTLINE (800) 348-2420 400 E. Spring St. Bluffton, IN 46714 Tel: 260-824-2900 Fax: 260-824-2909 P/N 225468101 Rev. 2 www.franklin-electric.com M1502 09/08