Soap/Sanitizer Dispensers

Similar documents
Soap/Sanitizer Dispensers

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

BARDON T01-C TOUCHLESS URINAL SENSOR INSTALLATION INSTRUCTIONS K-8787T-C02(DC/ ) K-8787T-C04(AC/ ) 18 E

Motion System Components Diagram. Note: #2 Mirror Cover and X-Axis Motor Cover have been removed for visibility. Maintenance.

INSTALLATION INSTRUCTIONS

NILFISK BA 500 Service Manual

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Tools Needed for Mounting Cleá Filling Station

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Multistage Air Filtration Systems Instruction Manual

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

INSTALLATION INSTRUCTIONS

Alliance Towel Dispensing System. Operation Manual

Automatic Dispenser (Hand Sanitizer Only) Drip Tray This drip tray can be used on both Automatic and Manual Dispensers

Self-Testing Industrial Series

M670/M680BD MAGNALOCK SERIES Installation Instructions

USER S MANUAL TUBE SEALER. Model SE250. No. CAT.SE25010Ce

PRODUCT MANUAL Gecko Wireless One Zone LED Dimmer and Receiver

Technical Manual. Table of Contents

ASX / OUTLANDER SPORT SHIFT KNOB MZ525507EX INSTALLATION AND HANDLING INSTRUCTIONS

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

Installation Instructions

SECTION 6 CORROSION PREVENTION AND APPEARANCE CARE. Corrosion prevention and appearance care

GENUINE REAR SPOILER

INSTALLATION INSTRUCTIONS

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

H15P. Toyota Hilux A-DECK Dual Cab

D40C HINGE # x Support Plate x M8 Bolt 8 x M8 Washer 6 x M6 20mm Bolts 6 x M6 Washers 19 x Screws

mm (16.1" 3.74" 3.86" ) Soap Tank Capacity 750ml Battery. 750ml AA (1.5V) 4

Cordless two speed drill/driver K 10613

Backpack Sprayer. Use and Care Manual

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

Spectron Industrial Series

8791T-C02( ) 8791T-C04(AC) 8791T-C04( ) size alkaline batteries(8791t-c02) 2 7 (AAA 2)(8791T-C02) 220V AC 50/60Hz(8791T-C04)

Reading this manual. Preface

Installation and Care Instructions

Q15P. Mitsubishi MQ Triton Dual Cab

Installation Instructions 1662SG SG.223

1PC TONNEAU COVER INSTALLATION INSTRUCTIONS IMPORTANT

Replacement Top Hardware Installation Instructions

Heavy Duty Sprayer Owners Manual Model MS-O

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

Installation Instructions 1662SG SG.222

USER S MANUAL TUBE SEALER. Model SE700. No. CAT.SE70011Ce

Horizontal Shadings. Continuous Cord Loop Beaded Chain Loop Cordless Lift. Installation & Operating Instructions

Installation Instructions 1662SG SG.224

Preface. Scope of Application. General Requirements for Safety THE SAFETY MARKS USED IN THIS INSTRUMENT

USER S MANUAL TUBE SEALER. Model SE450. No. CAT.SE45010Ce

GENUINE Interior Lighting Kit

Auto-Lift Operating System

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

GENUINE ILLUMINATED SCUFF PLATE

C15C C15C. Page 1 of 20

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Package Contents. Mounting Hardware

Battery-Powered Motorized System

Installation Instructions

TOOLPRO 18V 2 Speed Drill Driver

SAFETY AND OPERATING MANUAL. Lithium-Ion cordless hammer drill WX372 WX372.1 WX372.9

WARNING. This shows the detail that could lead to death or severe injury if ignored or through misuse the product.

82V LITHIUM-ION BATTERY CHARGER GC 400

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

INSTALLATION INSTRUCTIONS


M-1115S Series Fuel Pump

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

AutoClean Unit. Begin Top-Mount Installation. Top or Side Mount Installation INSTALLATION INSTRUCTIONS. Choose A Configuration. Side Mount.

for spiral staircases

Owner smanual. Banks Ram-Air Intake System Ford Power Stroke 6.7L Turbo Diesel F250/F350/F450 Trucks. with Installation Instructions

GENUINE MUD FLAP (REAR)

SPEAKER SYSTEMS F-2000B F-2000BT F-2000BTWP F-2000W F-2000WT F-2000WTWP OPERATING INSTRUCTIONS

PRODUCT MANUAL Gecko Wireless 2 Zone LED Dimmer and Receiver

Remote engine start INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

SZ2-ILA INSTRUCTIONS TRANSMITTED ILLUMINATION ATTACHMENT SZ-ADD SZ-POL-2 SZH-CLJ. Optional Modules

60V RECHARGEABLE LITHIUM-ION BATTERY

Installation Instructions

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Serena Remote Controlled Shades

Owner smanual. Banks Ram-Air Intake System Chevrolet 6.6L (LML) Duramax Turbo-Diesel Pickups. with Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

STRUKTURA T01-A INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

3PC TONNEAU COVER WITH SPORTS BAR INSTALLATION INSTRUCTIONS

Maintenance Information

GENUINE PARTS INSTALLATION INSTRUCTIONS

User Manual GRX- 950 and GRX- 950 Li

Installation Instructions

9-I DUETTE SHADES POWERVIEW MOTORISATION

Trackstar Motorized Folding Shade Installation Instructions

CBR1000RR/RA/S1/S2 Genuine Accessory User s Guide

Motorized Skylight Installation Instructions

Transcription:

Soap/Sanitizer Dispensers Installation & Operating Instruction Manual Thoroughly read this instruction booklet before operating Sloan dispensers. Keep this Installation & Operating Instruction Manual with other product information for future reference. Manual Dispensers SJS-1000 Soap Dispenser SJS-1100 Foam Soap Dispenser SJS-1400 Sanitizer Dispenser Electronic Dispensers SJS-1050 Touchless, Sensor-Operated Soap Dispenser Electronic Dispensers Manual Dispensers Table of Contents Page Dimensions 2-3 Installation and Set-up 4-7 Operation 8-9 Maintenance 9-10 Troubleshooting 11 Emergency Measures 11 Consumables Chart 11

Dimensions Manual Models (Fig. 1) 1.41" (36 mm) Mounting hole 10.04" (255 mm) 2.17" (55 mm) 5.28" (134 mm) 5.31" (135 mm) 4.41" (112 mm) Parts Manual Models (Fig. 2) Key Insert the key into the keyhole, and the cover will open toward you. Keyhole Mounting holes Soap/Sanitizer Pouches Manual Models (Fig. 3) Note the difference in the pouch nozzles. Sight glass Identifies amount of soap/sanitizer remaining. Lever Push the lever, and the liquid is dispensed. Mounting plate Foaming Soap Pouch Sanitizer and Skin Care Pouch 2

Dimensions Sensor Models (Fig. 4) 1.41" (36 mm) 2.17" (55 mm) Mounting hole 10.83" (154 mm) 6.07" (154 mm) 5.75" (146 mm) 3.51" (89 mm) Parts Sensor Models (Fig. 5) Soap Pouch Sensor Models (Fig. 6) Key Insert the Key into the Keyhole, and the cover will open toward you. Keyhole Mounting holes Sight glass Soap levels can be checked. Soap Pouch Sensor When the sensor senses the palm, the unit operates. Nozzle Liquid is dispensed. Pilot lamp DC jack Mounting plate 3

INSTALLATION AND SET-UP Parts Dispenser (1) Key (1) Alcohol Wipe (1) Screws (5) Wall Anchors (5) Double Face Tape (1) C-Cell Batteries (4) sensor models only STEP 1. Select an area on the wall with sufficient support The installation wall must be at least.25 (6 mm) thick or the area should be reinforced or risk failure due to the dispenser falling. Install in an area that does not experience extreme temperatures Avoid exposure to direct sunlight and keep away from heat sources such as cooking areas and heating devices. This may result in fire. The dispenser should be installed in an area that maintains an ambient temperature between 32 F and 95 F. Excessive moisture or water spray may result in rusting or malfunction. Direct sunlight may result in malfunction. Tools for Installation 1/4 drill bit 1/8 drill bit Power drill Phillips screwdriver Measure/Ruler Hammer Installation Procedure Check the installation wall. The wall anchors and screws are required for installation on a concrete wall. If the wall is weak paneling or plasterboard less than.25 (6 mm), the area should be reinforced. Optional AC Adapter for Sensor Models 1. If an outlet is not available in the installation area contact an electrician. 2. The power supply is AC100V-120V (50/60Hz). Wiring must conform to power supply requirements. 3. Keep moisture or water away from the outlet. 4. The length of the AC adapter cord is 5-9 (1.8 m). The outlet must be within this range. STEP 2. Positioning the dispenser (Fig. 7) To properly use key and to open door fully, allow clearance above and below dispenser as shown in Figure 7. Fig. 7 Obstruction Manual Model Obstruction Obstruction Sensor Model Obstruction STEP 3. Install the mounting plate (Fig. 8) Use the mounting plate holes as a guide for drilling. Fig. 8 Wall anchor Screws Mounting plate 4

When installing onto a concrete wall or drywall, drill 1 to 1.5 deep holes using a 1/4 drill bit. Mount plate with three wall anchors and screws. For wood walls, drill guide holes using a 1/8 bit and attach plate with three screws. Before drilling the holes, make sure there are no pipes or wires located behind the wall. Using double face tape to install the mounting plate (Fig. 9) When the installation area does not allow drilling, use double face tape to mount the dispenser by placing the tape on the back of the mounting plate after is has been cleaned of dust, dirt, oils and grease with the alcohol wipe. The wall area must also be cleaned in this manner. Let both the wall and mounting plate dry for at least 10 minutes. Fig. 9 Mounting plate STEP 4. Installing the main body (Fig. 10) Position the main body over the mounting plate and snap into place. Fig. 10 Main body Mounting plate STEP 5. Removing the dispenser from the main body (Fig. 12) Insert the key or a flathead screwdriver into the keyhole and slide the main body upward. Fig. 12 Keyhole Key or flathead screwdriver Inside of the main body (Front view) Double face tape Once tape is secured to the mounting plate, peel the protective paper from the double face tape and press the plate firmly to the wall and hold for 10 seconds. Leave the mounting plate attached to the wall and allow to dry for 24 hours before installing the dispenser. NOTE: Double face tape may not be used to mount the unit onto a wall with a coated surface or wallpaper. Double face tape cannot adhere to a wall with uneven or rough surface. 5

STEP 6. Opening/closing the cover (Fig. 13) Place the key into the keyhole on the top of the dispenser. Holding the cover, open it toward you. Return the cover to its original position and press it until it snaps into place. Fig. 14 Fig. 13 Cover Key Keyhole Cover STEP 7. Installing/replacing batteries for sensor models (Fig. 14) 1. Open the cover. Remove the pouch holder. 2. Place the key into the battery box hole to remove the battery box cover. 3. Install four new C-cell batteries in proper +/- orientation. NOTE: Supplied batteries are intended for checking operational status only. Install new batteries before operating. If the unit will be dormant for some time, remove batteries and store properly. Immediately remove batteries and replace when the red LED flashes. STEP 8. Installing/replacing Soap/Sanitizer pouches for manual units (Fig. 15) 1. Open the cover and remove the pouch from the dispenser. 2. Place the new pouch in the holder. 3. Remove the cap from the pump. 4. Close the cover. Installing/replacing Soap Pouches for Sensor Units (Fig. 16) 1. Open the cover and remove the pouch from the dispenser. 2. Place the new pouch in the holder. 3. Set the pouch pump in the battery box. 4. Remove the cap from the pouch pump. 5. Close the cover. 6

Fig. 15 Sanitizer/Soap Type Foaming Soap Type Holder Holder Pouch Pouch Cap Cap How to set the liquid and spray pump Insert the nozzle into the holder hole. How to set the foam pump Place pouch into holder, align nozzle with pins and snap into position as shown. Fig. 16 Knob Cap How to set the pump Hold the knob and remove the cap. While holding the pump knob, press it to the set position until it clicks. Battery box 7

OPERATION STEP 1. Operating instructions for manual models (Fig. 17) Press the lever to dispense the soap or sanitizer onto hands. NOTE: After the pouch is installed, liquid may not dispense immediately. To prime the unit, pump the lever until it dispenses. Do not pump violently. Fig. 17 STEP 2. Mode setting for Sensor Models (Fig. 18) Dispensing times can be adjusted to any of three modes. 1. Open the cover. 2. Pull out mode switch cover. 3. Using a screwdriver or the tip of a pen, switch the mode switch to the desired setting. The indicator lamp will blink according to the mode selected. Dispensing Long Short Medium Mode Position of Left Middle Right Mode Switch Indicator Blink 1X Blink 2X Blink 3X Lamp Place your hands under the dispenser to activate the sensor. For multiple soap applications, remove hands and place again under the unit to re-activate. Sensor Model features: Sensor: Recognizes hands so there is no need to touch the unit. Safety switch: Open the cover, set the power to OFF and the unit will no longer dispense. Pilot lamp: When the sensor recognizes a user s hands, the red LED will light. When the batteries lose power, the red LED light flashes. Key: Use the special key to open/close the dispenser cover. Precautions Before using the dispenser, thoroughly read the Precautions attached to the liquid products. Immediately clean any spill on the floor to help avoid falling, injuries or other hazards. 8

Fig. 18 Mode switch cover Indicator lamp Mode switch MAINTENANCE STEP 1. Cleaning the unit body To ensure longevity, carry out periodic maintenance. For standard cleaning, wipe off dirt with soft, dry cloth. For dispensers that are very dirty, wipe with a wet, soapy cloth. DO NOT USE: Thinner, benzene, alcohol, petroleum, powder soap, polishing powder, detergent other than neutral detergent, boiling water, acids, alkaline materials, scrub brushes, etc. STEP 2. Cleaning the nozzle of Sensor Models (Fig. 19) A clogged nozzle may result in poor dispensing or malfunction. To clean the nozzle: 1. Open the cover and clear the dispensing hole at the end of the nozzle with a thin wire pin (less than 0.5 mm) paper clips work well. 2. Close the cover. 3. Check if the unit dispenses properly. If the unit does not dispense properly, replace the pouch. Fig. 19 Nozzle Thin wire pin/ paperclip 9

MAINTENANCE STEP 3. Cleaning the nozzle of Manual Models (Fig. 20) A clogged nozzle may result in poor dispensing or malfunction. To clean the nozzle: Soap 1. Open the cover and clear the dispensing hole at the end of the nozzle with a thin wire pin (less than 0.5 mm) paper clips work well. 2. Close the cover. 3. Check if the unit dispenses properly. If the unit does not dispense properly, replace the pouch. Sanitizer 1. Open the cover and soak only the nozzle in hot water for approximately two minutes. 2. If the clog is still visible, clear the dispensing hole at the end of the nozzle with a thin wire pin (less than 0.5 mm) paperclips work well. 3. Close the cover and test again. 4. If the unit does not dispense properly, replace the pouch. Fig. 20 Nozzle Thin wire pin/ paperclip Nozzle Hot water 10

TROUBLESHOOTING Before calling for repair of Sensor Models Problem: The unit does not operate 1. Check if the unit is securely closed 2. Check if pump is securely set 3. Check if the batteries need replacement (flashing red LED) Problem: Liquid is not dispensed 1. Check if the liquid has run out 2. Check if nozzle is clogged Before calling for repair of Manual Models Problem: The unit does not operate 1. Check if the liquid has run out 2. Check if nozzle is clogged EMERGENCY MEASURES Take emergency measures listed on pouch label according to chemical being used. Eye contact: Flush eyes with water for a minimum of 15 minutes and consult a physician immediately. Ingestion: Drink water to induce vomiting and consult a physician immediately. Inhalation: Get fresh air immediately. If condition does not improve, consult a physician immediately. If trouble continues, call 877-752-6726. CONSUMABLES REFERENCE CHART Product No. Description For use with Order No. SJS-1001 Manual Wall-Mount Liquid Soap SJS-1000 5700200 SJS-1001-1 Manual Wall-Mount Liquid Soap with Moisturizers SJS-1000 5700201 SJS-1051 Sensor Wall-Mount Liquid Soap SJS-1050 5700400 SJS-1051-1 Sensor Wall-Mount Liquid Soap with Moisturizers SJS-1050 5700401 SJS-1101 Manual Wall-Mount Foam Soap SJS-1100 5700500 SJS-1101-1 Manual Wall-Mount Foam Soap with Moisturizers SJS-1100 5700501 SJS-1401 Manual Alcohol Hand Sanitizer SJS-1400 5700600 11

The information contained in this document is subject to change without notice. Air Delights, Inc. 9974 SW Arctic Drive Beaverton, Or. 97005 Phone: 800-440-5556 Fax: 503-643-8224 www.sloanvalve.com 2009 Sloan Valve Company Printed in the U.S.A. JSD6031.1 01/09