File E252 Vol. Sec. Gen. Page Issued: 2007-0-02 Revised: 20-0-8 GENERAL PRODUCT COVERED: Type VBII enclosed switch components for OEM assembly. * GENERAL CONSTRUCTION: This product shall comply with the Standard of Underwriters Laboratories Inc. for Enclosed Switches, UL 98, and with the applicable description, if any, given elsewhere in this Procedure.
File E252 Vol. Sec. Gen. Page 2 Issued: 2007-0-02 Revised: 2007-08-07 HORSEPOWER RATINGS: 0 AMP HORSEPOWER RATINGS Catalog Number VBFS22 VBFS22F VBFS2 VBFS2F VBNFS2 VBNFS2F VBNFS22 VBNFS22F VBFS26 VBFS26F VBFS6 VBFS6F VBNFS26 VBNFS26F VBNFS6 VBNFS6F Amp s 25 0 7 /2 2 5 0 7 /2 2 5 0 0 2 5 0 7 /2 2 5 0 7 /2 0 2 5 5 0 7 /2 7 /2 5 0 20 2 5 0 7 /2 0 2 5 5 0 0 0 20 5 0 2 5 (5**) (5**) ** - VDC rating shown in () applies when wired with jumper wire per illustration 2A.
File E252 Vol. Sec. Gen. Page Issued: 2007-0-02 Revised: 2007-08-07 HORSEPOWER RATINGS (Continued): 60 AMP HORSEPOWER RATINGS Catalog Number VBFS222 VBFS222F VBNFS22 VBNFS22F VBFS262 VBFS262F VBFS22 VBFS22F VBFS62 VBFS62F VBNFS262 VBNFS262F VBNFS62 VBNFS62F Amps 25 60 0 5 5 0 60 0 20 5 0 60 20 25 0 0 60 0 5 5 0 60 0 5 20 0 25 50 5 0 25(0**) 60 20 25 0 0 60 0 20 25 50 0 60 5 0 25(0**) ** - VDC rating shown in () applies when wired with jumper wire per illustration 2A.
File E252 Vol. Sec. Gen. Page 4 Issued: 2007-0-02 Revised: 2007-08-07 HORSEPOWER RATINGS (Continued): 00 AMP HORSEPOWER RATINGS Catalog Number VBNFS2 VBNFS2F VBFS22 VBFS22F VBFS26 VBFS26F VBFS2 VBFS2F VBFS6 VBFS6F VBNFS26 VBNFS26F VBNFS6 VBNFS6F Va c Amps 00 5 40 20 00 5 0 20 00 0 40 20 50 00 5 0 20 00 5 0 0 60 40 75 20 25 (50**) 00 0 40 20 50 00 20 40 40 75 50 00 20 25 (50**) ** - VDC rating shown in () applies when wired with jumper wire per illustration 2A.
File E252 Vol. Sec. Gen. Page 5 Issued: 2007-0-02 HORSEPOWER RATINGS (Continued): 200 AMP HORSEPOWER RATINGS Catalog Number Va c Amps VBNFS24 VBNFS24F VBFS224 VBFS224F VBFS24 VBFS24F VBFS64 VBFS64F VBNFS64 VBNFS64F 200 5 60 40 200 5 60 40 200 5 60 40 200 5 60 50 25 50 50 40 50 200 5 60 50 25 50 50 40 50
File E252 Vol. Sec. Gen. Page 6 Issued: 2007-0-02 HORSEPOWER RATINGS (Continued): 400 AMP HORSEPOWER RATINGS Cat. No. Volts Amps VBFS65 25 400 50 25 50 50 50 50 VBNFS65 400 50 25 50 50 50 50 AMP HORSEPOWER RATINGS Cat. No. Volts Amps VBFS66 25 50 200 50 400 50 500 50 VBNFS66 50 200 50 400 50 500 50
File E252 Vol. Sec. Gen. Page 7 Issued: 2007-0-02 MINIMUM ENCLOSURE SIZES: AMPERAGE DESCRIPTION LENGTH WIDTH DEPTH VOLUME 0 FUSIBLE 4.25 7.00 6.94 692.27 0 NON-FUSIBLE.78 7.00 6.94 572.27 60 FUSIBLE 6.0 9.05 6.94 02.75 60 NON-FUSIBLE 6.0 9.05 6.94 02.75 00 FUSIBLE 22.00 9.5 6.94 455.04 00 NON-FUSIBLE 22.00 9.5 6.94 455.04 200 FUSIBLE 0.00 4.50 7.70 49.50 200 NON-FUSIBLE 0.00 4.50 7.70 49.50 400 FUSIBLE 56.00 24.50 8.25 9.00 400 NON-FUSIBLE 44.00 24.50 8.25 889.50 FUSIBLE 56.00 24.50 8.25 9.00 NON-FUSIBLE 44.00 24.50 8.25 889.50
File E252 Vol. Sec. Gen. Page 8 Issued: 2007-0-02 Revised: 2008-02-25 ENVIRONMENTAL RATINGS: Flange mounted disconnect switch components are rated for use in Type,, R, and 2 environments when used in an enclosure rated for these conditions. See Conditions of Acceptability. Panel mounted disconnect switch components are rated for use in Type,, R, 2, and 4X environments when used with the appropriate handle kit in an enclosure rated for these conditions. See Conditions of Acceptability. *TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE): Use - For use only in complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. Conditions of Acceptability -. These devices should be mounted in equipment which provides a suitable overall enclosure. 2. These switch units have been tested with the units mounted on a vertical flat surface with the line side of the switch positioned at the top. Suitability of these units in all other positions shall be determined.. The voltage and horsepower ratings specified in table of catalog numbers may be assigned to the switch unit when it is installed in an enclosure or compartment if the minimum enclosure size is met. These dimensions are for heating considerations only. 4. The suitability of any other operating handle linkage provided beyond the switch unit handle shall be determined. Consideration should be given to performing a no-load Endurance Test. 5. The following tests have been conducted in accordance with the Standard for: a) Mechanical Endurance b) Rain c) Atomized Water d) Accelerated Aging of Gaskets e) Hosedown
File E252 Vol. Sec. Gen. Page 9 Issued: 2007-0-02 Revised: 200-0-0 CONSTRUCTION DETAILS: The product shall be constructed in accordance with the following description: CORROSION PROTECTION All steel parts will be plated, preplated galvanized, stainless steel or painted. MARKING: