TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Similar documents
Comfortable. Cooling/Heating Comfort Systems. Applied Air. Keeps You. Technical Guide for: IFL TGIFL-4

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

Warm. Air Turnover Systems. Applied Air. Keeps You. Technical Guide for: IFP IFS CAT IFA IFJ TGATS-4. Standard Gas Heat Air Turnover

WAC Air Curtains Technical Guide

Warm. SDFI Direct Fired Gas Heating System. Sterling. Keeps You. Technical Guide for: Indoor Mounted Units To 64,000 CFM And 9M BTUH

Warm. SDR Direct Fired Gas Heating System. Sterling. Keeps You. Technical Guide for: Outdoor or Indoor Mounted Units To 16,000 CFM And 1.

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Direct Gas-Fired Heating

ICEMINI & Vertical MTI Units

LIST PRICES WAC AIR CURTAINS

Power Flame Incorporated

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

INDIRECT FIRED FURNACE PARTS

ERU ENERGY RECOVERY UNIT

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Direct-Fired Make-Up Air Units

Twin City Fan & Blower

Direct Gas-Fired Make-up Air Heaters

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

A. NU2035 HRV Specifications NU2035

Climas y Proyectos Leyco, S.A. de C.V.

Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP)

ISO 9001 REGISTERED HTDM SERIES HTDM0600BR

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

SECTION AXIAL HVAC FANS

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

Complete HVAC Capability

forward curved inline duct blowers

Air Handling Unit Fan Selection Guide

D M S 760 C01 A A 1 1

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

G21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

Design and Application Details

ENVIRO UNIT CES SERIES

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

Centrifugal Filtered Supply Roof Blowers

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

VIFB Coil Technical Guide

Low Silhouette Power Roof Ventilator Propeller

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

Gas-Fired Separated Combustion Unit Heaters Propeller & Blower Models

FS Fan-Coil Units Hi-Rise, Vertical

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Filtered Kitchen Supply Packaged Ventilator

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

HVAC INDOOR MAKE-UP AIR HANDLERS

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

Tubular Centrifugal Fans

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

IMMERSION FIRED HOT WATER BOILER

Eclipse Hermetic Gas Boosters

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination.

Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat)

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm


R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

Industry best 5 year fan housing warranty, 1 year motor warranty

TYPICAL SPECIFICATION: Critical Process Roof Top Unit 7/14/15

FILTERED SUPPLY CENTRIFUGAL Belt Drive

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

Mixed Flow Inline Fan, Model MFSI

Centrifugal Spun Aluminum Products

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

Twin City Fan & Blower

AIR-AIR ENERGY CONSERVATION MODULE

Direct Fire Heated Make-Up Air Unit

SECTION CENTRIFUGAL HVAC FANS

Installation, Start-Up and Service Instructions

G21Q Bulletin # September 1992 Supersedes March 1992

HIGH VELOCITY FUME EXHAUST FANS

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

GAS-FIRED SEPARATED COMBUSTION UNIT HEATERS

FIXED PITCH PROPELLER FANS

PRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Multi-Port Centrifugal Fans for Round Duct

LOW PRESSURE MIXED FLOW FANS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Transcription:

TGIF-3 Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm

Indirect Fired Heating Systems Technical Guide In the business of industrial heating, efficient and low-cost operation is essential. Applied Air keeps you warm for less. Since 15, Applied Air has been providing cost-effective, reliable heating solutions. Our proven Indirect Fired Heating Systems add warm clean air to your work environment, but without the products of combustion in the airstream. This Technical Guide will help you choose an Applied Air Indirect Fired Gas Heating System to provide efficient, cost-effective heating and ventilation for your facility. The Guide covers: Technical Specifications Configure the right system components (e.g., motors, drive, filter, options, etc.) to meet your needs. Model "IF" for indoor installations Model "IFW" for outdoor installations Installation Information Plan details of on-site installation (dimensions, gas piping, etc.). If you have questions, please contact Applied Air s Customer Service Department at 4-638-10. We ll be glad to help. Applied Air Keeps You Warm In the interest of product improvement, Applied Air reserves the right to make changes without notice. 2

Unit Arrangements... 4 Air Delivery Tables... 5- Engineering Data... 10-11 Dimensions Standard Vertical Units... 12 Standard Horizontal Units... 13 Side Mount Filter and Filter/Mixing Box... 14 Base Mount Filter and Filter/Mixing Box... Dampers... 16 Service Platform... Discharge Nozzles... Intake Hoods... Amp Draw Table... 1 Typical Gas Piping Layout... 20 Guide Specification... - 3

Basic Types of Units Schematic Component Diagrams C000514 Style V floor-mounted vertical unit for duct installation. Style H indoor horizontal suspended unit for duct installation. Style VH indoor floor-mounted with optional adjustable discharge nozzles and screened inlets. Style HH indoor horizontal suspended unit with optional discharge nozzles. Style VW outdoor pad mounted vertical unit for duct installation. Style HW outdoor pad mounted horizontal unit for duct installation. (A) The Indirect Fired Series is available in a complete range of sizes from 350,000 to 6,000,000 BTU output. Indirect Fired units are assembled, wired and flametested before shipment. (B) Accessories such as filters banks, dampers, service platforms, discharge heads, vibration feet and hangers are available as optional items for special applications or installations. Power driven exhausters are standard equipment on all models. 4

Air Delivery Table All Models Total External Static Pressure (W.C.) Model Blowers SCFM 1 / 4 1 / 2 3 / 4 1 1 1 / 4 1 1 / 2 1 3 / 4 2 HP HP HP HP HP HP HP HP 35-40 (2) 12 x 3500 1 1 / 2 1 1 / 2 2 2 2 2 3 4000 1 1 / 2 2 3 3 3 3 3 3 35-40 (2) 12 x 4500 2 3 3 3 5 5 5 5 5000 3 3 3 5 5 5 5 5 5500 3 3 5 5 5 5 5 5 55/35-40 (2) 12 x 12 5000 2 2 3 3 3 3 5 5500 2 3 3 3 5 5 5 5 55/35-40 (2) 12 x 12 00 3 3 5 5 5 5 5 5 6500 3 5 5 5 5 5 5 000 5 5 5 5 5 5/35-40 (2) x 000 3 3 3 5 5 5 500 3 3 5 5 5 5 1 / 2 00 3 5 5 5 5 1 / 2 1 / 2 1 / 2 5/35-40 (2) x 8500 5 5 5 5 1 / 2 1 / 2 1 / 2 1 / 2 000 5 5 5 1 / 2 1 / 2 10 10 10 500 5 5 1 / 2 1 / 2 1 / 2 10 10 10 10,000 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 10 45-55 (2) 12 x 12 5000 2 2 3 3 3 3 5 5500 2 3 3 3 5 5 5 5 45-55 (2) 12 x 12 00 3 3 5 5 5 5 5 5 6500 3 5 5 5 5 5 5 000 5 5 5 5 5 5/45-55 (2) x 000 3 3 3 5 5 5 500 3 3 5 5 5 5 1 / 2 00 3 5 5 5 5 1 / 2 1 / 2 1 / 2 5/45-55 (2) x 8500 5 5 5 5 1 / 2 1 / 2 1 / 2 1 / 2 000 5 5 5 1 / 2 1 / 2 10 10 10 500 5 5 1 / 2 1 / 2 1 / 2 10 10 10 10,000 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 10 100/45-55 (2) x 000 3 5 5 5 5 1 / 2 500 3 5 5 5 5 1 / 2 1 / 2 10,000 3 5 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10,500 5 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10 100/45-55 (2) x 11,000 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 11,500 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 10 12,000 5 1 / 2 1 / 2 10 10 10 10 10 12,500 1 / 2 1 / 2 1 / 2 10 10 10 10 13,000 1 / 2 1 / 2 10 10 10 10 65-5 (2) x 000 3 3 3 5 5 5 500 3 3 5 5 5 5 1 / 2 00 3 5 5 5 5 1 / 2 1 / 2 1 / 2 65-5 (2) x 8500 5 5 5 5 1 / 2 1 / 2 1 / 2 1 / 2 000 5 5 5 1 / 2 1 / 2 10 10 10 500 5 5 1 / 2 1 / 2 1 / 2 10 10 10 10,000 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 10 NOTES: 1. Horsepower selections are based on system external static pressure. To determine total external static pressure, add all applicable accessory pressure drops listed below: A. Fresh Air Inlet Hood & Birdscreen 0.13 W.C. C. V-Bank Filter Section 0.25 W.C. B. Motor Operated Dampers 0.13 W.C. D. Discharge Nozzles 0.25 W.C. 2. Select unit size and motor horsepower from table above. 3. Contact factory for applications not shown. EXPLANATION OF MODEL NUMBERS DASH MODEL NUMBERS - A dash in the model number indicates the BTU range on the heat exchanger. Example: Model 35-40 has a heat exchanger rating of 350,000-400,000 BTU output. SLASH MODEL NUMBERS - A slash in the model number indicates the use of a larger blower section with a smaller heat exchanger, normally used for low temperature rise applications. Example: Model 5/35-40 has a 5 size blower section, which offers airflow up to 10,000 CFM, with a heat exchanger rating of 350,000-400,000 BTU output. 5

Air Delivery Table All Models Total External Static Pressure (W.C.) Model Blowers SCFM 1 / 4 1 / 2 3 / 4 1 1 1 / 4 1 1 / 2 1 3 / 4 2 HP HP HP HP HP HP HP HP 100/65-5 (2) x 000 3 5 5 5 5 1 / 2 500 3 5 5 5 5 1 / 2 1 / 2 10,000 3 5 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10,500 5 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10 100/65-5 (2) x 11,000 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 11,500 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 10 12,000 5 1 / 2 1 / 2 10 10 10 10 10 12,500 1 / 2 1 / 2 1 / 2 10 10 10 10 13,000 1 / 2 1 / 2 10 10 10 10 5/65-5 (3) x 13 13,000 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 14,000 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 10 10 10,000 1 / 2 1 / 2 10 10 10 10 10 16,000 1 / 2 10 10 10 10 5/65-5 (3) x 13,000 10 10 10,000 10 20 1,000 10 20 20 20,000 20 20 20 20,000 20 20 20 20 20 25 23,000 20 20 20 25 25 25 25 25 85-100 (2) x 000 3 5 5 5 5 1 / 2 500 3 5 5 5 5 1 / 2 1 / 2 10,000 3 5 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10,500 5 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10 85-100 (2) x 11,000 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 11,500 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 10 12,000 5 1 / 2 1 / 2 10 10 10 10 10 12,500 1 / 2 1 / 2 1 / 2 10 10 10 10 13,000 1 / 2 1 / 2 10 10 10 10 5/85-100 (3) x 13 13,000 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 14,000 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 10 10 10,000 1 / 2 1 / 2 10 10 10 10 10 16,000 1 / 2 10 10 10 10 5/85-100 (3) x 13,000 10 10 10,000 10 20 1,000 10 20 20 20,000 20 20 20 20,000 20 20 20 20 20 25 23,000 20 20 20 25 25 25 25 25 250/85-100 (3) x,000 10 20 20 20 20 23,000 20 20 20 20 25 25,000 20 20 20 25 25 25 25 250/85-100 (3) x 2,000 20 20 25 25 25 2,000 25 25 40 40 40 31,000 40 40 40 40 40 40 33,000 40 40 40 40 40 6 NOTES: 1. Horsepower selections are based on system external static pressure. To determine total external static pressure, add all applicable accessory pressure drops listed below: A. Fresh Air Inlet Hood & Birdscreen 0.13 W.C. C. V-Bank Filter Section 0.25 W.C. B. Motor Operated Dampers 0.13 W.C. D. Discharge Nozzles 0.25 W.C. 2. Select unit size and motor horsepower from table above. 3. Contact factory for applications not shown. EXPLANATION OF MODEL NUMBERS DASH MODEL NUMBERS - A dash in the model number indicates the BTU range on the heat exchanger. Example: Model 35-40 has a heat exchanger rating of 350,000-400,000 BTU output. SLASH MODEL NUMBERS - A slash in the model number indicates the use of a larger blower section with a smaller heat exchanger, normally used for low temperature rise applications. Example: Model 5/35-40 has a 5 size blower section, which offers airflow up to 10,000 CFM, with a heat exchanger rating of 350,000-400,000 BTU output.

Air Delivery Table All Models Total External Static Pressure (W.C.) Model Blowers SCFM 1 / 4 1 / 2 3 / 4 1 1 1 / 4 1 1 / 2 1 3 / 4 2 HP HP HP HP HP HP HP HP 125-5 (3) x 13 13,000 5 5 1 / 2 1 / 2 1 / 2 1 / 2 10 10 14,000 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 10 10 10,000 1 / 2 1 / 2 10 10 10 10 10 16,000 1 / 2 10 10 10 10 125-5 (3) x 13,000 10 10 10,000 10 20 1,000 10 20 20 20,000 20 20 20 20,000 20 20 20 20 20 25 23,000 20 20 20 25 25 25 25 25 250/125-5 (3) x,000 10 20 20 20 20 23,000 20 20 20 20 25 25,000 20 20 20 25 25 25 25 250/125-5 (3) x 2,000 20 20 25 25 25 2,000 25 25 40 40 40 31,000 40 40 40 40 40 40 33,000 40 40 40 40 40 0/125-5 (3) 20 x 20 2,000 20 20 25 25 25 25 31,000 20 20 20 25 25 25 25 0/125-5 (3) 20 x 20 33,000 20 20 25 25 25 35,000 25 25 25 25 40 40 3,000 25 40 40 40 50 3,000 40 40 40 40 40 50 200-250 (3) x,000 10 20 20 20 20 23,000 20 20 20 20 25 25,000 20 20 20 25 25 25 25 200-250 (3) x 2,000 20 20 25 25 25 2,000 25 25 40 40 40 31,000 40 40 40 40 40 40 33,000 40 40 40 40 40 0/200-250 (3) 20 x 20 2,000 20 20 25 25 25 25 31,000 20 20 20 25 25 25 25 0/200-250 (3) 20 x 20 33,000 20 20 25 25 25 35,000 25 25 25 25 40 40 3,000 25 40 40 40 50 3,000 40 40 40 40 40 50 35,000 20 20 20 25 25 25 3,000 20 20 25 25 40 3,000 20 25 25 40 40 41,000 25 25 40 40 40 40 400/200-250 (3) x 43,000 40 40 40 40 50 45,000 40 40 40 40 50 50 50 4,000 40 40 40 40 50 50 50 50 4,000 40 40 50 50 50 50 51,000 50 50 50 50 53,000 50 50 5 5 5 NOTES: 1. Horsepower selections are based on system external static pressure. To determine total external static pressure, add all applicable accessory pressure drops listed below: A. Fresh Air Inlet Hood & Birdscreen 0.13 W.C. C. V-Bank Filter Section 0.25 W.C. B. Motor Operated Dampers 0.13 W.C. D. Discharge Nozzles 0.25 W.C. 2. Select unit size and motor horsepower from table above. 3. Contact factory for applications not shown. EXPLANATION OF MODEL NUMBERS DASH MODEL NUMBERS - A dash in the model number indicates the BTU range on the heat exchanger. Example: Model 35-40 has a heat exchanger rating of 350,000-400,000 BTU output. SLASH MODEL NUMBERS - A slash in the model number indicates the use of a larger blower section with a smaller heat exchanger, normally used for low temperature rise applications. Example: Model 5/35-40 has a 5 size blower section, which offers airflow up to 10,000 CFM, with a heat exchanger rating of 350,000-400,000 BTU output.

Air Delivery Table All Models Total External Static Pressure (W.C.) Model Blowers SCFM 1 / 4 1 / 2 3 / 4 1 1 1 / 4 1 1 / 2 1 3 / 4 2 HP HP HP HP HP HP HP HP 25-0 (3) 20 x 20 2,000 20 20 25 25 25 25 31,000 20 20 20 25 25 25 25 25-0 (3) 20 x 20 33,000 20 20 25 25 25 35,000 25 25 25 25 40 40 3,000 25 40 40 40 50 3,000 40 40 40 40 40 50 400/25-0 (3) x 35,000 20 20 20 25 25 25 3,000 20 20 25 25 40 3,000 20 25 25 40 40 41,000 25 25 40 40 40 40 400/25-0 (3) x 43,000 40 40 40 40 50 45,000 40 40 40 40 50 50 50 4,000 40 40 40 40 50 50 50 50 4,000 40 40 50 50 50 50 51,000 50 50 50 50 53,000 50 50 5 5 5 0/25-0 (3) 2 1 / 2 x 2 1 / 2 55,000 25 25 40 40 40 40 58,000 25 40 40 40 40 40 50 61,000 40 40 40 50 50 50 50 64,000 40 40 50 50 50 50 0/25-0 (3) 2 1 / 2 x 2 1 / 2 6,000 40 50 50 50 50 0,000 40 50 50 5 3,000 50 50 5 5 5 5 6,000 50 5 5 5 5,000 5 5 5 5 5 5 81,000 5 5 5 5 5-400 3) x 35,000 20 20 20 25 25 25 3,000 20 20 25 25 40 3,000 20 25 25 40 40 41,000 25 25 40 40 40 40 5-400 3) x 43,000 40 40 40 40 50 45,000 40 40 40 40 50 50 50 4,000 40 40 40 40 50 50 50 50 4,000 40 40 50 50 50 50 51,000 50 50 50 50 53,000 50 50 5 5 5 0/5-400 (3) 2 1 / 2 x 2 1 / 2 55,000 25 25 40 40 40 40 58,000 25 40 40 40 40 40 50 61,000 40 40 40 50 50 50 50 64,000 40 40 50 50 50 50 0/5-400 (3) 2 1 / 2 x 2 1 / 2 6,000 40 50 50 50 50 0,000 40 50 50 5 3,000 50 50 5 5 5 5 6,000 50 5 5 5 5,000 5 5 5 5 5 5 81,000 5 5 5 5 8 NOTES: 1. Horsepower selections are based on system external static pressure. To determine total external static pressure, add all applicable accessory pressure drops listed below: A. Fresh Air Inlet Hood & Birdscreen 0.13 W.C. C. V-Bank Filter Section 0.25 W.C. B. Motor Operated Dampers 0.13 W.C. D. Discharge Nozzles 0.25 W.C. 2. Select unit size and motor horsepower from table above. 3. Contact factory for applications not shown. EXPLANATION OF MODEL NUMBERS DASH MODEL NUMBERS - A dash in the model number indicates the BTU range on the heat exchanger. Example: Model 35-40 has a heat exchanger rating of 350,000-400,000 BTU output. SLASH MODEL NUMBERS - A slash in the model number indicates the use of a larger blower section with a smaller heat exchanger, normally used for low temperature rise applications. Example: Model 5/35-40 has a 5 size blower section, which offers airflow up to 10,000 CFM, with a heat exchanger rating of 350,000-400,000 BTU output.

Air Delivery Table All Models Total External Static Pressure (W.C.) Model Blowers SCFM 1 / 4 1 / 2 3 / 4 1 1 1 / 4 1 1 / 2 1 3 / 4 2 HP HP HP HP HP HP HP HP 0S/5-400 (3) x 3,000 40 40 40 50 50 6,000 40 50 50 50 5 5,000 50 50 50 5 5 5 0S/5-400 (3) x 82,000 50 50 5 5 5 100 85,000 50 5 5 5 100 100 88,000 5 5 100 100 100 100 1,000 5 5 5 100 100 100 100 4,000 5 5 5 100 100 100 100 100 500-0 (3) 2 1 / 2 x 2 1 / 2 55,000 25 25 40 40 40 40 58,000 25 40 40 40 40 40 50 61,000 40 40 40 50 50 50 50 64,000 40 40 50 50 50 50 500-0 (3) 2 1 / 2 x 2 1 / 2 6,000 40 50 50 50 50 0,000 40 50 50 5 3,000 50 50 5 5 5 5 6,000 50 5 5 5 5,000 5 5 5 5 5 5 81,000 5 5 5 5 5 0S/500-0 (3) x 3,000 40 40 40 50 50 6,000 40 50 50 50 5 5,000 50 50 50 5 5 5 0S/500-0 (3) x 82,000 50 50 5 5 5 100 85,000 50 5 5 5 100 100 88,000 5 5 100 100 100 100 1,000 5 5 5 100 100 100 100 4,000 5 5 5 100 100 100 100 100 NOTES: 1. Horsepower selections are based on system external static pressure. To determine total external static pressure, add all applicable accessory pressure drops listed below: A. Fresh Air Inlet Hood & Birdscreen 0.13 W.C. C. V-Bank Filter Section 0.25 W.C. B. Motor Operated Dampers 0.13 W.C. D. Discharge Nozzles 0.25 W.C. 2. Select unit size and motor horsepower from table above. 3. Contact factory for applications not shown. EXPLANATION OF MODEL NUMBERS DASH MODEL NUMBERS - A dash in the model number indicates the BTU range on the heat exchanger. Example: Model 35-40 has a heat exchanger rating of 350,000-400,000 BTU output. SLASH MODEL NUMBERS - A slash in the model number indicates the use of a larger blower section with a smaller heat exchanger, normally used for low temperature rise applications. Example: Model 5/35-40 has a 5 size blower section, which offers airflow up to 10,000 CFM, with a heat exchanger rating of 350,000-400,000 BTU output.

Engineering Data Capacity and Internal Data SIZE & CAPACITY FIRING RATE & MANIFOLD SIZE EQUIPMENT & HEAT EXCHANGER DATA INTERNAL DATA OF HEAT EXCHANGER (A) Model Size Input B.T.U./Hour Output B.T.U./Hour(B) Natural Gas 1,000 B.T.U./C.F. Nat. Gas Std. Pipe Size (8 to 14 W.C.) Discharge Heads Amt./Size Throw W/0 Nozzles (Feet) Throw W/45 Nozzles (Feet) Combustion Air Required (C.F.M.) Exhauster Model Exhauster H.P. Recommended Min. Stack Size Dia. Primary Heating Surface Sq. Feet Secondary Htg. Surface (Tubes & Headers) Sq. Feet Primary Combustion Volume Cu. Feet Secondary Combustion Volume Cu. Feet Total Combustion Chamber Volume Cu. Feet 35 40 45 50 55 43,500 500,000 2,500 625,000 68,500 350,000 400,000 450,000 500,000 550,000 438 500 3 625 688 1 1 1 1 1 2/ 2/ 3/ 3/ 3/ 8 6 88 8 10 8 116 100 100 110 1 145 1 0 12 12 12 12 12 1/3 1/3 1/3 1/3 1/3 8 8 8 8 8 41 41 50 50 50 1 1 3 3 4 4 4 28 28 28 SIZE & CAPACITY FIRING RATE & MANFOLD SIZE EQUIPMENT & HEAT EXCHANGER DATA INTERNAL DATA OF HEAT EXCHANGER (A) Model Size Input B.T.U./Hour Output B.T.U./Hour(B) Natural Gas 1,000 B.T.U./C.F. Nat. Gas Std. Pipe Size (8 to 14 W.C.) Discharge Heads Amt./Size Throw W/0 Nozzles (Feet) Throw W/45 Nozzles (Feet) Combustion Air Required (C.F.M.) Exhauster Model Exhauster H.P. Recommended Min. Stack Size Dia. Primary Heating Surface Sq. Feet Secondary Htg. Surface (Tubes & Headers) Sq. Feet Primary Combustion Volume Cu. Feet Secondary Combustion Volume Cu. Feet Total Combustion Chamber Volume Cu. Feet 65 5 85 100 125 812,500 3,500 1,062,500 1,250,000 1,2,500 650,000 50,000 850,000 1,000,000 1,250,000 813 38 1,063 1,250 1,3 1 1 / 4 1 1 / 4 1 1 / 2 1 1 / 2 1 1 / 2 4 / 4/ 4 / 4 / 4/ 5 110 1 14 3 106 123 165 1 0 0 25 5 400 14 14 14 14 1/2 1/2 1/2 1/2 2 10 10 10 10 12 41 41 86 86 12 58 58 85 85 34 34 88 5 5 3 3 55 55 (A) Standard construction - 400 series stainless steel primary and mild steel secondary. All stainless steel heat exchangers available for outside air and other special applications Optional construction - 400 series stainless steel primary and secondary. Recommended when % or more winter outside air is introduced, or temperature rise at minimum firing rate is below 10 F. (B) Based on % operating efficiency. 10

Engineering Data Capacity and Internal Data SIZE & CAPACITY FIRING RATE & MANIFOLD SIZE EQUIPMENT & HEAT EXCHANGER DATA INTERNAL DATA OF HEAT EXCHANGER (A) Model Size Input B.T.U./Hour Output B.T.U./Hour(B) Natural Gas 1,000 B.T.U./C.F. Nat. Gas Std. Pipe Size (8 to 14 W.C.) Discharge Heads Amt./Size Throw W/0 Nozzles (Feet) Throw W/45 Nozzles (Feet) Combustion Air Required (C.F.M.) Exhauster Model Exhauster H.P. Recommended Min. Stack Size - Dia. Primary Heating Surface Sq. Feet Secondary Htg. Surface (Tubes & Headers) Sq. Feet Primary Combustion Volume Cu. Feet Secondary Combustion Volume Cu. Feet Total Combustion Chamber Volume Cu. Feet 0 5 200 250 25 (C) 1,85,000 2,,500 2,500,000 3,125,000 3,43,500 1,500,000 1,50,000 2,000,000 2,500,000 2,50,000 1,85 2,8 2,500 3,125 3,438 2 2 2 2 1 / 2 2 1 / 2 4/ 4/ 5/ 5/ 6/ 3 2 2 235 205 238 2 2 2 0 5 650 0 8 2 2 2 5 5 12 12 14 16 16 12 12 165 165 6 166 166 8 88 88 1 1 165 14 14 138 138 SIZE & CAPACITY FIRING RATE & MANIFOLD SIZE EQUIPMENT & HEAT EXCHANGER DATA INTERNAL DATA OF HEAT EXCHANGER (A) Model Size Input B.T.U./Hour Output B.T.U./Hour(B) Natural Gas 1,000 B.T.U./C.F. Nat. Gas Std. Pipe Size (8 to 14 W.C.) Discharge Heads Amt./Size Throw W/0 Nozzles (Feet) Throw W/45 Nozzles (Feet) Combustion Air Required (C.F.M.) Exhauster Model Exhauster H.P. Recommended Min. Stack Size Dia. Primary Heating Surface Sq. Feet Secondary Htg. Surface (Tubes & Headers) Sq. Feet Primary Combustion Volume Cu. Feet Secondary Combustion Volume Cu. Feet Total Combustion Chamber Volume Cu. Feet 0 (C) 5 (C) 350 (C) 400 (C) 500 (C) 0 (C) 3,50,000 4,062,500 4,35,000 5,000,000 6,250,000,500,000 3,000,000 3,250,000 3,500,000 4,000,000 5,000,000 6,000,000 3,50 4,063 4,35 5,000 6,250,500 2 1 / 2 2 1 / 2 3 3 (CF) (CF) 6/ / / / 12/ (D) 12/ (D) 250 0 4 26 354 2 20 24 28 334 38 1,040 1, 1,0 1,0 1,20 5 5 5 5 5 5 16 16 16 16 6 4 4 4 450 450 8 283 283 283 4 4 165 2 2 2 585 585 28 28 28 3 3 20 20 20 6 6 (A) Standard construction - 400 series stainless steel primary and mild steel secondary. Optional construction - 400 series stainless steel primary and secondary. Recommended when % or more winter outside air is introduced, or temperature rise at minimum firing rate is below 10 F. (B) Based on % operating efficiency. (C) Model 25-0 shipped in two pieces. Special shipping permits and heights required. Consult factory. (D) When all 0 nozzles are furnished (optional extra). extensions for 6 are included. 11

Dimensions Vertical Units C000458 NOTE: For units with Internal Blower/Motor Isolation, dimensions C and J will increase by 12. Model 35-40 55/40 5/40 45-55 5/55 100/55 65-5 100/5 5/5 85-100 5/100 250/100 125-5 250/5 0/5 200 0/200 400/200 250 0/250 400/250 25-0 400/0 0/0 5-400 0/400 500-0 0S/0 Approximate Weight (lbs) Indoor Outdoor 0 50 10 0 2000 2350 00 00 00 2500 20 200 00 255 00 285 30 425 2500 25 4000 4525 4500 5025 4100 465 40 55 00 655 40 5250 00 6650 6650 0 40 5250 00 6650 6650 0 6100 500 60 8200 000 10,400 000 800 500 11,200 10,500 12,500 12,500 14,500 "A" 54 54 54 65 65 0 65 0 65 0 0 85 "B" 0 0 100 0 100 100 1 1 1 0 1 0 0 200 NOTE: All dimensions in inches subject to manufacturing tolerances. "C" 4 5 / 8 4 5 / 8 4 5 / 8 82 5 / 8 82 5 / 8 86 5 / 8 82 5 / 8 86 5 / 8 86 5 / 8 5 / 8 5 / 8 5 / 8 103 5 / 8 103 5 / 8 106 1 / 8 103 5 / 8 106 1 / 8 1 103 5 / 8 106 1 / 8 1 1 1 / 8 1 5 / 8 141 5 / 8 138 5 / 8 5 / 8 18 5 / 8 18 5 / 8 "D" "E" "F" 6 1 / 4 6 1 / 4 6 1 / 4 6 1 / 4 6 1 / 4 6 1 / 4 Dimensions "G" 20 1 / 2 1 / 2 20 1 / 2 20 1 / 2 20 25 20 25 16 1 / 2 "H" 6 3 / 8 6 3 / 8 6 3 / 8 6 3 / 8 6 3 / 8 6 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 "J" 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 5 / 8 1 / 8 5 / 8 3 1 / 8 1 / 8 5 / 8 3 1 / 8 5 / 8 3 1 / 8 1 / 8 3 1 / 8 1 / 8 1 / 8 1 / 8 "M" 6 6 86 6 86 6 86 6 116 6 116 1 116 1 4 116 1 4 1 4 4 4 4 4 14 "N" 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 6 1 / 2 6 1 / 2 6 1 / 2 85 1 / 2 85 1 / 2 85 1 / 2 101 1 / 2 101 1 / 2 142 1 / 2 142 1 / 2 "P" 28 1 / 2 28 1 / 2 31 28 1 / 2 31 28 1 / 2 31 50 31 50 50 50 "S" 12 EXPLANATION OF MODEL NUMBERS DASH MODEL NUMBERS - A Dash in the model number indicates the BTU range on the heat exchanger. Example: Model 35-40 has a heat exchanger rating of 350,000-400,000 BTU output. SLASH MODEL NUMBERS - A Slash in the model number indicates the use of a larger blower section with a smaller heat exchanger, normally used for low temperature rise applications. Example: Model 5/35-40 has a 5 size blower section, which offers airflow up to 10,000 CFM, with a heat exchanger rating of 350,000-400,000 BTU output.

Dimensions Horizontal Units C000458 4 NOTE: For units with Internal Blower/Motor Isolation, dimensions C and J will increase by 12. Model 35-40 55/40 5/40 45-55 5/55 100/55 65-5 100/5 5/5 85-100 5/100 250/100 125-5 250/5 0/5 200 0/200 400/200 250 0/250 400/250 25-0 400/0 0/0 5-400 0/400 500-0 0S/0 Approximate Weight (lbs) Indoor Outdoor 0 50 10 0 2000 2350 00 00 00 2500 20 200 00 255 00 285 30 425 2500 25 4000 4525 4500 5025 4100 465 40 55 00 655 40 5250 00 6650 6650 0 40 5250 00 6650 6650 0 6100 500 60 8200 000 10,400 000 800 500 11,200 10,500 12,500 12,500 14,500 "A" 54 54 54 65 65 0 65 0 65 0 0 85 "B" 0 0 100 0 100 100 1 1 1 0 1 0 0 200 NOTE: All dimensions in inches subject to manufacturing tolerances. "C" 4 5 / 8 4 5 / 8 4 5 / 8 82 5 / 8 82 5 / 8 86 5 / 8 82 5 / 8 86 5 / 8 86 5 / 8 5 / 8 5 / 8 5 / 8 103 5 / 8 103 5 / 8 106 1 / 8 103 5 / 8 106 1 / 8 1 103 5 / 8 106 1 / 8 1 1 1 / 8 1 5 / 8 141 5 / 8 138 5 / 8 5 / 8 18 5 / 8 18 5 / 8 "D" "E" "F" 6 1 / 4 6 1 / 4 6 1 / 4 6 1 / 4 6 1 / 4 6 1 / 4 Dimensions "G" 20 1 / 2 1 / 2 20 1 / 2 20 1 / 2 20 25 20 25 16 1 / 2 "H" 6 3 / 8 6 3 / 8 6 3 / 8 6 3 / 8 6 3 / 8 6 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 3 / 8 "J" 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 1 / 8 5 / 8 1 / 8 5 / 8 3 1 / 8 1 / 8 5 / 8 3 1 / 8 5 / 8 3 1 / 8 1 / 8 3 1 / 8 1 / 8 1 / 8 1 / 8 "M" 6 6 86 6 86 6 86 6 116 6 116 1 116 1 4 116 1 4 1 4 4 4 4 4 14 "N" 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 6 1 / 2 6 1 / 2 6 1 / 2 85 1 / 2 85 1 / 2 85 1 / 2 101 1 / 2 101 1 / 2 142 1 / 2 142 1 / 2 "R" 28 50 50 50 61 61 64 61 64 61 64 4 64 4 4 "S" EXPLANATION OF MODEL NUMBERS DASH MODEL NUMBERS - A Dash in the model number indicates the BTU range on the heat exchanger. Example: Model 35-40 has a heat exchanger rating of 350,000-400,000 BTU output. SLASH MODEL NUMBERS - A Slash in the model number indicates the use of a larger blower section with a smaller heat exchanger, normally used for low temperature rise applications. Example: Model 5/35-40 has a 5 size blower section, which offers airflow up to 10,000 CFM, with a heat exchanger rating of 350,000-400,000 BTU output. 13

Dimensions Side V-Bank Filter with Mixing Box for Vertical Units C000510A 14 Model A B C D E F 35-40 45-55 65-5 85-100 125-5 200-250 25-0 5-400 500-0 0 100 1 0 28 1 / 2 3 NOTES: 1. All dimensions in inches subject to manufacturing tolerances. 2. Use dimension B for V-bank filter section only. 28 1 / 2 33 52 6 86 6 116 1 6 6 63 5 5 63 83 83 85 1 / 2 0 10 3. Dampers may be shipped loose, to meet shipping restrictions; field adaptation and mounting by others. 4. Damper blade dividers furnished as required. Number & Size of Filters (6) 16 x 25 x 2 () 20 x 20 x 2 (12) 20 x 20 x 2 (16) 20 x 20 x 2 () 20 x 20 x 2 () 20 x 20 x 2 (4) 20 x 20 x 2 (64) 20 x 20 x 2 (0) 20 x 20 x 2 Approximate Weight (lbs) V-Bank 1 2 1 42 682 853 105 13 V-Bank/Mixing Section 5 582 63 82 11 13 01 302

Dimensions Base V-Bank Filter with Mixing Box for Horizontal Units C000511A Model A B C D E F G 35-40 45-55 65-5 85-100 125-5 200-250 25-0 5-400 500-0 0 100 1 0 31 54 65 0 28 50 61 66 6 NOTES: 1. All dimensions in inches subject to manufacturing tolerances. 2. Use dimension B for V-bank filter section only. 6 86 6 116 1 6 6 5 5 5 63 63 63 65 1 / 2 0 6 28 1 / 2 33 52 3. Dampers may be shipped loose, to meet shipping restriction; field adaptation and mounting by others. 4. Damper blade dividers furnished as required. Number & Size of Filters () 16 x 20 x 2 () 20 x 20 x 2 (12) 20 x 20 x 2 (16) 20 x 20 x 2 () 20 x 20 x 2 () 20 x 20 x 2 (4) 20 x 20 x 2 (64) 20 x 20 x 2 (0) 20 x 25 x 2 Approximate Weight (lbs) V-Bank 12 1 26 2 5 583 1016 16 V-Bank/Mixing Section 628 3 25 2 13 186 2342 5 41

Dimensions Base Inlet Damper for Horizontal Units C000512 Model A B C D 35-40 45-55 65-5 85-100 125-5 200-250 25-0 5-400 500-0 0 100 1 0 54 65 0 NOTES 1. All dimensions in inches subject to manufacturing tolerances. 2. Dampers may be shipped loose, to meet shipping restrictions; field adaptation and mounting by others. 3. Blade dividers furnished as required. 6 86 6 116 1 4 4 28 50 61 66 4 Approximate Weight (lbs) 128 161 14 251 8 4 535 6 53 Side Inlet Damper for Vertical Units C000512 Model A B C D 35-40 45-55 65-5 85-100 125-5 200-250 25-0 5-400 500-0 1 / 4 0 100 1 / 8 1 / 8 0 1 / 2 3 43 1 / 8 55 5 / 8 5 1 / 4 86 5 3 / 4 1 5 / 8 135 1 / 2 1 / 8 3 1 / 2 NOTES 1. All dimensions in inches subject to manufacturing tolerances. 2. Dampers may be shipped loose, to meet shipping restrictions; field adaptation and mounting by others. 3. Blade dividers furnished as required. 28 1 / 4 51 Approximate Weight (lbs) 110 1 0 3 25 4 2 16

Dimensions Service Platform for Horizontal Units Model A B 35-40 45-55 65-5 85-100 125-5 200-250 3 81 81 2 102 102 Approximate Weight (lbs) 5 2 2 5 3 3 NOTES 1. All dimensions in inches subject to manufacturing tolerances. 2. Contact factory for dimensional details on units larger than 250 or models with optional V-bank or V-bank/mixing section. Discharge Nozzle C00046 NOTES 1. Nozzles 0 rotatable. 2. Diffusing vanes are adjustable. 3. Nozzles supplied as optional. 4. All dimensions in inches subject to manufacturing tolerances. 5. Nozzles and one piece filler plate (Model 35-55) or plenum extensions (Model 65-400) shipped separately for field adaptation by others. 6. Overall height of nozzles and extensions or filler plate furnished for remote mounting is (1) inch plus B or D dimension.. For slash units (400/200, etc.) consult factory. Model A B C D E F G 35-40 45-55 65-5 85-100 125-5 200-250 25-0 5-400 25 25 25 25 31 31 31 31 6 6 6 6 10 10 10 10 23 1 / 2 23 1 / 2 23 1 / 2 23 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 0 100 1 500-0 Consult Factory 1 / 2 1 / 2 25 23 3 / 8 / 8 Number of Nozzles and Size 2 EA. 3 EA. 4 EA. 4 EA. 4 EA. 5 EA. 6 EA. EA. Approximate Weight (lbs) 113 26 4 4 503

Dimensions Intake Hood for Weatherproof Units C0005 Model A B C 35-40 45-55 65-5 85-100 125-5 200-250 25-0 5-400 500-0 54 65 0 0 100 1 0 25 / 8 1 / 8 25 / 8 28 1 / 2 46 3 / 4 55 3 / 4 54 3 / 4 66 10 5 / 8 Approximate Weight (lbs) 85 8 110 26 402 42 63 5 NOTES 1. All dimensions in inches subject to manufacturing tolerances. 2. Hoods may be shipped loose, to meet shipping restrictions; field adaptation and mounting by others.

Electrical Data Amp Draw Table Item A Item B Blower Motor Blower Motor Burner Motor HP (4) Induced Draft Fan Motor HP Burner Motor HP (4) Induced Draft Fan Motor HP Burner Motor HP (4) Induced Draft Fan Motor HP NOTES: 1) NA = Not Available SOURCE AMPS (2) 2) Motor amps are based on 2011 edition of NEC. 3) Control circuit amps are based on standard controls. 4) Standard PowerFlame gas burner. 208V 3 PH 2V 3 PH 4V 3 PH 55V 3 PH SOURCE AMPS (2) 208V 3 PH 2V 3 PH 4V 3 PH 55V 3 PH SOURCE AMPS (3) Amp Draw for Burner Motor, Induced Draft Motor, and Control Transformer 208V 3 PH 2V 3 PH 4V 3 PH 55V 3 PH SOURCE AMPS (3) Amp Draw for Burner Motor, Induced Draft Motor, and Control Transformer 208V 3 PH 2V 3 PH 4V 3 PH 55V 3 PH SOURCE AMPS (3) Amp Draw for Burner Motor, Induced Draft Motor, and Control Transformer 208V 3 PH 2V 3 PH 4V 3 PH 55V 3 PH MOTOR HORSEPOWER 1 1/2 2 3 5 1/2 10 20 6.6.5 10.6 16..2.8 46.2 5.4 6.0 6.8.6.3.0 28.8 42.0 54.0 3.0 3.4 4.8.6 11.0 14.4.0 2.0 2.4 2. 3. 6.1.0 11.5.0.0 MOTOR HORSEPOWER 25 40 50 5 100 4.8 88.0 NA NA NA NA NA 68.0.0 104 1 4 NA NA 34.0 40.0 52.0 65.0.0 6.0 1 2.0.0 41.0 52.0 62.0.0.0 BURNER SIZE 35 40 45 50 55 65 5 1/4 1/4 1/4 1/4 1/4 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/2 1/2.2.2.2.2.2.6.6 6.5 6.5 6.5 6.5 6.5 8. 8. 3.3 3.3 3.3 3.3 3.3 4.3 4.3 2.6 2.6 2.6 2.6 2.6 3.5 3.5 BURNER SIZE 85 100 125 0 5 200 250 1/3 1/3 1/3 1/3 1/3 3/4 1 1/2 1/2 1/2 2 2 2 2 5.6.6 12.3 12.3 12.3 13.4 25. 8. 8. 11.1 11.1 11.1 12.2 23.5 4.3 4.3 5.6 5.6 5.6 6.1 11. 3.5 3.5 4.4 4.4 4.4 4..4 BURNER SIZE 25 0 5 350 400 500 0 1 1/2 1 1/2 1 1/2 3 3 5 5 5 5 5 5 5 5 5 25. 25. 25. 2. 2. 35.8 35.8 23.5 23.5 23.5 2.1 2.1.8.8 11. 11. 11. 13.5 13.5 16.3 16.3.4.4.4 10. 10. 13.1 13.1 Steps to Size Optional Disconnect Switch: 1. Find Blower Motor HP from tables on pages 5 -. 2. Find amp draw for Blower Motor HP from chart in Item A above. 3. Determine proper burner size required. 4. Find amps for Burner Motor, Induced Draft Motor, and Control Transformer from chart in Item B above. 5. Add amps from steps 2, and 4, then multipy by 1.25. 1

Gas Piping Layout Schematic Component Diagrams C000513B 20 COMPONENT IDENTIFICATION GP-05 MAIN GAS PRESSURE REGULATOR GP-0 PILOT GAS PRESSURE REGULATOR GP-11 MAIN GAS SHUT-OFF VALVE GP-13 PILOT GAS SHUT-OFF VALVE GP- AUXILIARY GAS SHUT-OFF VALVE GP-2 ORIFICED NEEDLE VALVE GP-3 BUTTERFLY VALVE (MODULATING BURNERS ONLY) MT-11 BUTTERFLY VALVE OPERATOR (MODULATING BURNERS ONLY) PS-01 DRAFT PROVING SWITCH PS-02 BURNER AIR FLOW SWITCH PS-04 LOW GAS PRESSURE SWITCH PS-0 HIGH GAS PRESSURE SWITCH VG-01 PILOT GAS VALVE VG-02 MAIN GAS VALVE VG-03 AUXILIARY GAS VALVE VG-04 N/O VENT VALVE NOTES: 1. Vent limiting devices provided wherever possible, when venting is required * the venting to outside is by others on indoor units and furnished by factory on outdoor units. 2. Models through 50 MBH output require 6 W.C. minimum inlet pressure. Larger models require 8 W.C. minimum inlet pressure. Contact factory for inlet pressures below these minimums. 3. Standard manifold meets FM requirements for units less than or equal to 2000 MBH output for ETL listed units. 4. Standard manifold meets IRI requirements for ETL listed units.

Guide Specifications Base Bid Applied Air Model (IF)(IFW) Indirect Fired heating and make-up air unit(s) designed for (indoor) (outdoor) application. The unit shall be factory fabricated, assembled, wired and tested prior to shipment in accordance with the specification and equipment schedule. The unit will include all components herein and as shown on the drawings. Alternate equipment, equal in design, construction, performance and capacity to unit(s) specified, must be shown with price deduct/add, if any. Approval of alternate equipment will be subject to review of shop drawings. The unit shall be capable of delivering SCFM at ESP using a horsepower (ODP) (TEFC) motor operating on 208/2/4/55/3/. The unit shall be ETL listed. CASING The unit casing shall consist of gauge galvanized steel panels over a structural steel framework to ensure rigidity. Cabinet construction shall allow unit(s) to be mounted in the (vertical ) (horizontal) arrangement with no external framework. The casing enclosing the heat exchanger shall be of double wall construction with a galvanized steel inner wall serving as a radiation shield. Radiation and transmission losses shall not exceed 2% of the rated output. This section shall be insulated with 1, 1 1 / 2 lb. density insulation. Hinged access doors with cadmium plated piano type hinges shall be supplied to allow physical entry to all sections requiring inspections and periodic maintenance. Access doors shall be complete with 1 thick insulation, interior metal liner, captive screws, fasteners, and handles. IFW MODELS ONLY The unit shall have a weatherproof enclosure to protect the gas burner, direct drive induced draft fan, and controls. The enclosure will be complete with hinged access doors, captive screws, fasteners and handles. The weatherproof enclosure will have louvered panels to provide outside air required for proper combustion and cooling. Flue products will be vented outside of enclosure. BLOWER SECTION Each unit shall be supplied with multiple centrifugal forward curve, DWDI blowers rated in accordance with AMCA standards. The blowers are to be mounted on a heavy duty, turned and ground and polished solid steel shaft designed for a maximum operating speed not to exceed 5% of its first critical speed. The bearings are to be of the heavy-duty industrial pre-lubricated, self aligning type. Models 125 and larger will include a double row spherical roller bearing on drive side for maximum bearing life. Drives shall have a capacity 25% greater than the motor horsepower. Blower and motor sheaves shall be laser aligned to provide maximum belt and sheave life. The motor sheave shall be of the adjustable pitch type for motors up to 1 / 2 H.P. The fan motor shall be mounted on an adjustable base and wired in flexible conduit to the control panel in the factory. All units with three or more bearings will be laser aligned in the factory to provide minimum vibration and maximum bearing life. All models 125 and larger shall be vibration balanced as a complete assembly in the factory. INDIRECT GAS FIRED SECTION The entire primary heat transfer surface and header shall be of 400 series stainless steel; the secondary heat transfer surface shall be (mild steel ) (400 series stainless steel). The heat exchanger design shall permit unrestricted lateral and peripheral expansion during the heating and cooling cycle. The flue gas travel shall be of four-pass design, with no internal baffles. The surface temperature of the heat exchanger shall not exceed 5% of its scaling temperature when operating at rated capacity. The heat exchanger shall be rated at a minimum of % efficiency at rated output. A pressure relief door complete with an observation window to view the flame shall be provided. DIRECT DRIVE INDUCED DRAFT FAN An integrally mounted, heavy duty, non-clogging radial blade induced draft fan complete with direct drive motor shall be provided. The induced draft fan shall be adequately sized to insure proper draft conditions when operating at rated capacity and equipped with a manual damper complete with locking quadrant to ensure proper draft and extended heat exchanger performance. BURNER The gas burner shall be of the power type, complete with integral combustion air blower and motor, combustion air proving switch, and removable pilot assembly. The combustion air damper shall be interlocked with the gas control valve to insure a proper gas/air mixture throughout the complete range of operation. Burner and controls shall be capable of delivering MBH output firing on (natural gas) (propane) at an inlet pressure of (inches water column) (PSIG) and in accordance with (manufacturer s standard) (FM) (IRI) requirements. Burner and controls shall be arranged for (On-Off) (High/Low/Off) (Full Modulation with low fire start and a turndown ratio). The factory wired and piped valve train shall be mounted inside the unit weatherproof enclosure (on IFW models) and be complete with: low pressure appliance regulator motorized gas control valve main manual test firing shut-off valve pilot manual shut-off valve pilot pressure regulator pilot automatic shut-off valve pilot manual test firing shut-off valve

Guide Specifications ELECTRICAL CONTROLS A NEMA 1 control panel complete with hinged access door shall be mounted inside the weatherproof enclosure (on IFW models). All control components are to be labeled and individually wired to a numbered terminal strip to aid in servicing. All wiring shall be color coded and number tagged at each end to match the control diagram supplied. Full operating and maintenance instructions shall accompany each unit. All wiring between the controls and valves shall be run in flexible conduit. All electrical components shall bear the U.L. label. The control system shall include but not be limited to the following components required for automatic operation: control circuit transformer fan motor starters, overloads and sub-circuit fuses control circuit fuses control relays electronic flame relay complete with alarm contacts induced draft fan air proving differential switch high limit switch automatic/manual fan switch heavy duty ignition transformer OPTIONAL EQUIPMENT & CONTROLS 1. Motorized inlet air shut-off damper with heavy gauge galvanized steel frame. Blades shall be die formed, triple V-groove 16 gauge galvanized steel, maximum 6 wide. Axles shall be 1 / 2 plated steel. 2. V-Bank filer section with nominal 2 thick (throwaway) (pleated) (cleanable) filters. 3. Combination filter/mixing section with nominal 2 thick (throwaway) (pleated) (cleanable) filters and motorized mixing dampers with a heavy gauge galvanized steel frame. Blades shall be die formed, triple V-groove 16 gauge galvanized steel, maximum 6 wide. Axles shall be 1 / 2 plated steel. The damper motor and linkage shall be mounted inside the unit casing. 4. Closure panels 5. Screened inlet section 6. 0 Discharge nozzles for vertical models. 45 Discharge nozzles for horizontal models 8. Inlet hood and birdscreen. Insulated (blower section) (filter section) (filter/mixing section) 10. Structural base frame for horizontal units 11. Service platform with guardrails for horizontal units 12. Extended lube lines 13. Internal blower/motor isolation 14. DDC Controls. Mild weather shutdown ductstat 16. Clogged filter switch and indicating light.. Disconnect switch. Painted galvanized casing 1. High gas pressure regulator (shipped loose for inlet pressures over 1 PSIG. 20. Circuit analyzer. Remote control panel.. Night set back thermostat 23. day time clock. Timed freeze protection 25. On-Off night setback thermostat. Smoke detector

23

Efficient Indirect Fired Heating Systems Choose Applied Air Indirect Gas Fired Systems Heat large spaces or warehouses without products of combustion in the supply air Mount units indoor, outdoors, or on the roof Low operating and maintenance costs Simple, inexpensive installation Applied Air, a leader in research, engineering, and customer service since 15 Applied Air www.appliedair.com Transport Drive Dallas TX 5 Telephone 4.638.10