IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

Similar documents
IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Combined Ventilation Controller RVWS-T-224HA

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

SetPoint 501 and 501s Controllers Installation and Operation Manual

M100F Incremental Motor Actuator R81F Interface Board

A419ABG-3C Electronic Temperature Control

R81EAA-2 Economizer Circuit Board

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Carbon Monoxide Transmitter

Operation and Installation Manual

SE8300 Series Installation Guide 24 Vac Low Voltage

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

Signet Temperature Transmitter

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

Signet Pressure Transmitter

CP (Vdc) CP (Milliamp) CP (Slidewire)

Digital Room Thermostats with Touch Screen LCD

SEN and SEN Outdoor Air Temperature Sensors

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

M9216 Series Electric Spring Return Actuators

DIFFERENTIAL THERMOSTAT

System 350 P352AB Electronic Pressure Control Series

Signet Pressure Transmitter

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Application Engineering

User Manual. Solar Charge Controller 3KW

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

R & D SPECIALTIES ROTROL I USER'S MANUAL

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

Installation & Operation Manual

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Installation & Operation Manual

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

General Description. Product Specification. Document Digital Temperature Interlock

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

5600 Series Power Operator Installation and Instruction Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Temperature Controller OVATION 214 User's Guide

User Manual Solar Charge Controller 3KW

SIGNET Temperature Transmitter

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

MS Application. Features. Proportional Valve Actuator General Instructions

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Special Specification 6058 Battery Back-Up System for Signal Cabinets

GL-235 Solar Pool Controller

INSTALLATION INSTRUCTIONS

YCCS TE-6800 Series Temperature Sensors

ITS-50R TRANSFER SWITCH OWNER S MANUAL

Analog Condensate Monitor Instruction & Maintenance Manual

TM-9100 Series Room Command Module

SERIES 700 ANALOG ELECTRONIC CONTROLS

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Installation and Operating Manual

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

BAPI-Stat 3 Room Sensor

FHC-1D user manual. Features

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

SAX Electronic Valve Actuator

PRODUCT INFORMATION BULLETIN

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

RP-4000 Reserve Power Control

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

Application Engineering

L5000 Plus. Installation & Setup Guide

Installation & Operation Manual

How to Select the RE Industrial Actuator Part Number

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

WARNING IMPORTANT

CONSTANT PRESSURE CONTROLLERS

THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller

SetPoint 150 Controller Installation Manual

Model 124 Filter Minder & Model 124

EMP1 OPERATING & INSTALLATION INSTRUCTIONS

LTX RF LEVEL SENSOR. Instruction Manual

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

KE2 Parts & Accessories

Transcription:

DIFFERENTIAL TEMPERATURE CONTROLLERS MAIN FEATURES - Microprocessor programed specifically for optimal performance of WARM AIR systems - Large easy-to-read 40 character (x0) backlit LCD display showing every parameter measured and controlled by the onboard microprocessor - With IMC s exclusive DATA PORT designed for use with one of these optional devices: - REMOTE 4 LINE LCD DISPLAY - DATA ADAPTER TO PC S RS-3 - DATA ADAPTER TO PC S USB - SD CARD RECORDER - BACNET INTERFACE This unique transmitter allows these devices to be located up to 500 feet away connected with a conventional CAT-5 cable - Model IP has an electrically isolated DATA PORT to maximize reliability for systems requiring permanent monitoring - Power relay that can handle up to 0 A or HP See specifications on pg 3 for complete ratings - Fault LED indicators for simple diagnostics - Electrostatic discharge protected electronics - Polyester coated 16 gage rugged steel enclosure with features for efficient installation - Reliable operation when installed where the ambient swings do not exceed -10 to 10 F * Model is available with power cord and receptacle for simpler installation SHOWN AT 5/8 SCALE INSTRUMENTS, INC WARM AIR DIFFERENTIAL TEMPERATURE CONTROL COL =1041 HSE = 83 PKH = 83 PKL= 701 COL =1041 HSE = 83 PKH = 83 PKL= 701 POWER FAN INSTRUMENTS, INC MADE IN WISCONSIN, USA SYSTEM STATUS PRESS TO DISPLAY MORE TEMPS PRESS-HOLD 8 SEC TO CLEAR PEAKS CONFORMS TO UL STD 873 COLTR LO LIM FAULT 4003997 CONTROLLERS conform to UL STD 873 with 1/ conduit holes for permanent wiring hard wired : Product # EW1-000-WA with NON-isolated DATA PORT EW1-000-WAIP with isolated DATA PORT US THERMOSTAT LOCAL LCD DISPLAY Page 1 is shown to the left Pages, 3 & 4 are shown below: Tel: 715-53-801 Fax: 715-53-811 468 Liberty Drive Wittenberg, WI 54499 USA The LCD display has lines of 0 characters each The top line permanently displays the COLLECTOR and the HOUSE temperatures The bottom line can be paged (switched) by pressing the black button These pages display all system information*including relay override switch status COL =1041 HSE = 83 DIF COL = =1041 00 CLL HSE = = 900 83 FAN= COL =1041 OFF SLL= HSE OFF = 83 TST = 800 AX1 = 385 * ALL TEMPERATURES ARE IN DEGREES FAHRENHEIT COL= COLLECTOR; HSE= HOUSE PKH= HOUSE PEAK HIGH; PKL= HOUSE PEAK LOW DIF= DIFFERENTIAL; CLL= COLLECTOR LOW LIMIT FAN= STATUS; SLL= SYSTEM LOW LIMIT (OFF/ON) TST= THERMOSTAT; AX1= AUXILIARY SENSOR Web: wwwsolarimcinstrumentscom EW1-000-WA Rev 11-0-11 PG- 1

CONTROLLER OPERATION HI LIMIT House Thermostat Operation- Adjustment range is 65 F to 105 F w / 3 F hysteresis Locate thermostat in HOUSE space to be heated When the SPACE temperature rises 3 F above the THERMOSTAT s dialed setting, the DIFFERENTIAL CONTROLLER will disable its TEMPERATURE DIFFERENTIAL and LOW LIMIT control functions and the FAN relay will turn off without delay When the SPACE temperature decreases below the THERMOSTAT s setting, the CONTROLLER will enable its DIFFERENTIAL and LOW LIMIT control functions as described below DIFFERENTIAL Control Operation- ON DIF setpoint adjustment range is 8 F to 4 F with 4 F fixed OFF When the temperature difference between solar COLLECTOR and SPACE sensors ( HSE located in the THERMOSTAT) exceeds the dialed ON differential ON DIF setting, the FAN relay will actuate after a 30-second delay The BLUE LED indicator will also turn ON When the temperature difference decreases and falls 4 F ( C) below the dialed ON DIF, the FAN relay and the BLUE LED indicator will turn off without delay LOW LIMIT Control Operation- LO LIM setpoint adjustment range 30 F to 110 F with 10 F hysteresis This feature is incorporated to prevent the system from operating the FAN when the collector temperatures are too low and could result in COLD DRAFTS in the heated space If the Collector Sensor temperature is below the LOW limit LO LIM setting, the controller s DIFFERENTIAL function will be disabled and the POWER RELAY will be kept in the OFF position If the COLLECTOR s temperature rises above the LOW LIMIT setting PLUS 10 F, the DIFFERENTIAL CONTROL function will be enabled and the controller will return to normal TEMPERATURE DIFFERENTIAL operation Example of Residential CONTROLLER settings: Space Thermostat setting = 850 F This will set the maximum allowable space temperature Space temp < 850 F Heating enabled Space temp > 850 + 3 F Heating disabled Controller Settings; Differential ON DIF = 150 F When the COLLECTOR rises 150 F warmer than HOUSE while heating is enabled, the FAN will turn ON When this temperature difference drops to 11 F (15-4) then the fan will turn OFF Low Limit LO LIM = 900 F minimum Collector temperature for system operation Collector temp < 900 F Heating disabled Collector temp > 900+10 F Heating enabled DATA-PORT This PORT transmits data ONLY, it is NOT bi-directional The frequency at which the data transmissions occur is selected by the data refresh jumper labeled S 6M on the circuit board (see drawing) Set jumper position to S for one complete line of total system information to be sent to the computer every seconds, or set to 6M for 6 minutes Complete instructions are supplied with accessories required to connect to a computer DO NOT CONNECT THIS PORT DIRECTLY TO ANY ETHERNET DEVICE OR COMPUTER PORT! TYPICAL RANDOM SAMPLE DATA collected from PORT- (not all controllers output the same format) RUNTIME COLL-T HOUSE-T DIFF-T COLim-T TSTA-1 AUX-1 FAN SLoLi FAULT THESE COMMENTS ARE NOT TRANSMITTED- 0:00 107 690 080 910 75 OPENS ON OFF System circulating WARM AIR; AUX-1 NC 0:06 879 690 080 910 75 OPENS OFF OFF LoColTem-FAN->OFF Collector temp too low; FAN OFF 0:1 103 690 080 910 75 OPENS OFF OFF FanSW! Fan override switch ON 0:18 1034 OPENS 080 910 75 OPENS OFF OFF SENS! Bad HOUSE sensor/broken wires; FAN OFF 0:4 103 690 080 910 OPENS OPENS OFF OFF Bad thermostat/broken wires; FAN OFF IMPORTANT NOTICE- If a malfunction of an E series controller could cause personal injury or damage to equipment or property, other limit or safety controls, or alarm or supervisory systems, intended to warn and or protect against such occurrences must be incorporated into and maintained as part of the control system This redundant built-in safety is required EW1-000-WA Rev 11-0-11 PG-

SPECIFICATIONS Controller Power Input: 5 Watts Minimum @ 10VAC ± 10% 50/60HZ Power Relay Contact Ratings: Common (CM)- 30VDC MAX or 40VAC MAX Normally Open (NO)- 0A Resistive @ 10VAC & 40VAC 1 HP @ 10VAC; HP @ 40VAC 0A @ 30VDC; TV-5 Normally Closed (NC)- 15A Resistive @ 10VAC & 40VAC 1/4 HP @ 10VAC; 1/ HP @ 40VAC 15A @ 30VDC Relay Action: 30sec delay ON; no delay OFF ON Differential: Adjustable 8 to 4 F; Fixed 4 F hysteresis Low Limit: Adjustable 30 to 110 F; Fixed 10 F reset Accuracy: +/- 1 F Sensors: 10K @ 77 F (5 C) Rated to 400 F Environmental: -10 to 10 F @ 0 to 95 %RH Dimensions & Weight: 500 W x 61 H x 50 D; Appx 0 lbs DATA PORT FOR IMC ACCESSORIES ONLY - SEE MANUAL! RELAY (FAN) OVERRIDE SWITCH AUT- NORMAL SETTING DATA REFRESH JUMPER: SEC / 6 MIN PR# EW1-000-WAIP NEC CLASS CIRCUITS TEMPERATURE SENSORS (4): COL- COLLECTOR TST- THERMOSTAT HSE- HOUSE AX1- OPTIONAL SENSORS are Industrial grade 10K IMC thermistors rated for 400 F with +/-1 F accuracy When sensors are installed properly, the additional error is ONE degree max for these cable lengths: 1000 ft of 18 ga; 700 ft of 0 ga; 500 ft of ga One BOLT-ON sensor and one THERMOSTAT (with the HOUSE sensor) are included with each controller Contact factory for availability of other probe types and sizes NOTICE: The DATA PORT s RJ-45 is NOT an ethernet or network connection! DATA PORT FOR IMC ACCESSORIES ONLY - SEE MANUAL! COLLECTOR TO TST DIFFERENTIAL DIAL-ADJ RELAY (PUMP/FAN): (UL & CSA LISTED) WITH 10V JUMPER NO- 0 A RES; 1 HP NC- 15 A RES; 1/4 HP WITHOUT JUMPER COM- 40 VAC NO- 0 A RES; HP NC- 15 A RES; 1/ HP RELAY (FAN) OVERRIDE SWITCH AUT- NORMAL SETTING DATA REFRESH JUMPER: SEC / 6 MIN 1/ CONDUIT 4-HOLES BOTTOM & 1 EA SIDE PR# EW1-000-WA NEC CLASS CIRCUITS TEMPERATURE SENSORS (4): COL- COLLECTOR TST- THERMOSTAT HSE- HOUSE AX1- OPTIONAL WA REV DATE 10 VAC 0 AMP RELAY JUMPER BOLT-ON sensor MOUNT ENCLOSURE WITH #10 SCREWS SPACED 55 IN REV: 09-6-11 SHLD WIRE- CONNECT TO SENSOR CABLE SHIELDS USE 1/8 WIDE BLADE SCREW DRIVER TURN CCW TO OPEN HOLE FOR WIRE ( TO 18 GA) COLLECTOR LOW LIMIT DIAL-ADJ KNOB STYLE VARIES POWER WIRING PER LOCAL CODES- USE 16,18 GA SOLID; 1,14 GA STRANDED 1 OR OF SAME GA UNDER EACH CLAMP CIRCUIT POWER (4W): EG- EARTH GROUND N- NEUTRAL (WHT) L - 10VAC ± 10% (BLK) 5/8TH SCALE INTERNAL DRAWING WITH METAL COVER AND H-V WIRING ACCESS COVER REMOVED EW1-000-WA Rev 11-0-11 PG- 3

CONTROLLER INSTALLATION MOUNTING- The Eagle line of SOLAR controllers are designed to be mounted indoors, protected from rain and condensing or dripping moisture Overhead sensor wires may provide a path for dripping liquids, so form a drip loop before wire enters the enclosure opening Use two #10 screws in the enclosure keyholes for mounting on a vertical wall with the two conduit holes facing down to the floor After wiring and adjustments are done, replace the metal cover and tighten screws firmly SENSOR INSTALLATION AND WIRING- Sensor installation should be done in a manner as to permit proper sensor contact of the areas to be measured Cover and/or insulate the sensors to prevent them from being affected by the surrounding ambient temperatures Sensor wiring installed outdoors must be rated for OUTDOOR use All connections exposed to the weather must be made with waterproof outdoor rated connectors Today s strong radio interference RI environment requires that all sensor wiring be shielded Listed below are a few suggested cable/wire part numbers Any other cable/wire selected must also meet local codes Wiring exposed to outdoor weather must be rated for outdoor use by its manufacturer Minimum recommended specifications- Better specifications- Best specifications- Audio Belden # 9451-10 Black (ga) PLTC Belden # 93 (ga) or 930 (0ga) PLTC Belden # 93 (ga) or 930 (0ga) The cable s shielding wires must be connected to the green wire that is identified as SHLD on the cover s backside label or the controller s drawing on page 3 Connect all the shielding wires together with the wire-nut (supplied) or other reliable means Ungrounded shields may result in damage to the Solar controller circuits The shielding wires requires grounding at the controller side ONLY DO NOT attempt to ground the collector panel with this wiring SENSOR SCREW TERMINALS- There are 8 or 10 screws on a GREEN block labeled TEMPERATURE SENSORS - see drawing on page 3 These terminals accept solid or stranded wire 18 to ga These are low voltage NEC class circuit connections For efficient and reliable wire connections, strip 3/16 to 3/8 of insulation from an undamaged wire end Use a strip tool that will not nick the conductors If wire is solid, make sure that the tip is NOT deformed so that it will fit into the terminal hole easily If the wire is stranded, make sure the strands are tightly twisted Using a 1/8" (3mm) wide blade screwdriver, turn CCW to open the terminal hole fully Then guide the wire into the terminal hole and hold while tightening (turn CW) the screw to clamp the wire WARNING- If a 5/3" (4mm) wide screwdriver blade is used, the plastic ridge that retains the screws will be scraped off allowing them to fall out DO NOT reverse the screw turning directions and place the wire outside the metal cage creating an unreliable connection DO NOT slip off the screw and damage any circuit components Inspect that ALL the strands are clamped in the terminal s cage HIGH VOLTAGE (H-V) WIRING- Wiring within the H-V compartment must be performed by an electrician or a trained technician Make certain that power is OFF or disconnected when the H-V access cover is removed POWER relay terminals are rated for 0amps max at 40vac max The 10VAC 0A RELAY JUMPER on the CM terminal MUST be removed for relay operation other than 10VAC See SPECIFICATION section for complete relay contact ratings All connections must be made with copper wires properly inserted and tightened All wiring used within this H-V compartment must have insulation rated for the highest voltage used on any connection, typically that would be 300 volt E controllers are manufactured with one of two types of terminal blocks The black "US" barrier type with a clamping washer & safety cover or the green "EU" type with recessed screws & square wire holes Wire gauge used must be in accordance with local codes Instructions for connections to the "US" type terminals (black)- Strip 1/" of insulation off DO NOT nick wire or strands Use one wire 18 or 16 solid or 18 to 1 AWG stranded Or use two same size wires in one terminal so the washer clamps them with equal pressure Tighten terminal screw with a # Phillips or a 1/4" wide x 035 thick blade tipped screwdriver to a max torque of 10 in-lbs After inspecting, remember to snap on the safety cover Instructions for connections to the "EU" type terminals (green)-strip 3/8" of insulation off DO NOT nick wire or strands Use one wire 18 or 16 solid or 18 to 10 AWG stranded Or use two 14 or 1 AWG wires in one terminal When using solid wire, they must fit side-by-side so they clamp with equal pressure Tighten terminal screw with a 3/16" wide x 05 thick blade tipped screwdriver to a max torque of 5 in-lbs If three or more wires require a common connection, it should be done in accordance with accepted methods by an electrician and may require additional space in a separate junction box Avoid using solid wire thicker than 16 AWG, because the circuit board can be damaged when forcing the wires into the H-V compartment Line or power wires should NOT be bundled with or placed in the same conduit with sensor or data cables COLLECTOR GROUNDING- The Solar collector panel array must be GROUNDED directly to an earth ground rod This is necessary to prevent damage from nearby lightening strikes which induce very DAMAGING high voltages in any ungrounded metal surface Please consult local, state and federal codes for proper grounding Please visit our website for news or recently released product information: wwwsolarimcinstrumentscom EW1-000-WA Rev 11-0-11 PG- 4

FORCED AIR SOLAR HEATING SYSTEM WARM AIR SOLAR COLLECTORS HEATED AIR 10K SENSOR COLLECTOR SENSOR EAGLE WARM AIR DIFFERENTIAL CONTROLLER COL=1351 SPA=744 DIF =80 LOL=950 IMC SPACE T STAT SETPOINT HSE TST INCLUDES : SPACE SENSOR AND SETPOINT POTENTIOMETER FAN UNIT AIR INLET SENSORS COL HSE STAT AUX1 EG POWER L1 N GR RELAY CONTACTS M L1 N Rev 0-15-011 EW1-000-WA Rev 11-0-11 PG- 5 INSTRUMENTS, INC