High Performance Thermal Circuit Breaker

Similar documents
High Performance Thermal-Magnetic Circuit Breakers 410/520/

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Thermal Overcurrent Circuit Breaker 3120-F...

Simulator switch, magnetic operation

Thermal-Magnetic Circuit Breaker M1-..

Thermal Overcurrent Circuit Breaker 3120-F...

Magnetic Overcurrent Circuit Breaker

Thermal Overcurrent Circuit Breaker 3130

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3130

Thermal Circuit Breaker / Switch Series 3131

Thermal Overcurrent Circuit Breaker 3130

Thermal Circuit Breaker / Switch Series 3131

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data

Thermal Circuit Breaker / Switch Series 3131

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal Circuit Breaker 3120-F...

Electronic Circuit Breaker ESS20-0..

Electronic circuit breaker EBU10-T

Electronic Circuit Breaker ESS20

Thermal-magnetic Miniature Circuit Breaker 4230-T...

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

TMC 91H is now TMC 60 C Series

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Circuit Breakers. DIN rail-mounted equipment protection

circuit breakers circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, 2- or 3-pole Description Applications

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON

LK Position Switches TECHNICAL DATASHEET.

Miniaturized limit switches

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications

K50F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TECHNICAL DATA

UMBW-UL489 and UL1077 Listed

Special Purpose Fuses

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TeChniCAl DATA

13000 series Professional quick-break momentary pushbutton switches

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

FL series position switches

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

MS-Series. Circuit Breaker

Standard Interlock Safety Switches

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

Product Data Sheet 8314 HR-197

Semiconductor Fuses Microswitches & Studs

Safety rope switches with reset for emergency stop

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Safety rope switch with reset for emergency stop

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Safety switches for hinges

HL (AZH) LIMIT SWITCHES

Technical Information

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Limit Switches - Limit Type Plastic Body IP65

Series L9 UL489 Miniature Circuit Breakers

G-Series. Circuit Breaker.

Limit Switches - Limit Type Plastic Body IP65

General_technical_data Series

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

LR-LX-LK-LW Safety Switches with separate actuator

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

BETA Switching Switches and Light Indicators

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Fuse switch disconnectors

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Model Number Structure

DuraSeal Heat-Shrinkable Environmentally Sealed, Nylon Insulated Crimp Terminals and Disconnects

DD Frame - Series Circuit Breakers

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

PDR circuit breaker - Ground fault Datasheet

Solenoid Locking Safety Switches

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

FR circuit breaker - hydraulic magnetic,

4314/17T. Product Data Sheet INDEX

Position Switches Series 8070/2

Product Data Sheet 3214 J/2H3F-191

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Standard Interlock Safety Switches

Limit Switches - Limit Type (PS21L) Metal Body IP66

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

Transcription:

High Performance Thermal Circuit Breaker 43-... Description Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position. Threadneck panel mounted and available in tracked vehicle, aircraft and general purpose versions. Typical applications Extra low voltage wiring systems on all types of vehicles for land, sea and air; defence equipment; battery powered machines. Ordering information Type No. 43 threadneck panel mounting Terminal design K4 screw terminals M6 (to aircraft specs.) K54 reinforced screw terminals M6, housing sealed Version FN2 vehicle application, nickel-plated LN2 aircraft application, black finish N2 general application, nickel-plated Current ratings 30...55 A (-FN2) 30...90 A (-LN2/N2) 43 - K4 - LN2-40 A ordering example Preferred types Preferred types Standard current ratings (A) 30 35 40 45 50 60 70 80 90 43-K54-FN2- x x x x x 43-K4-LN2- x x x x x x x x x Standard current ratings and typical voltage drop values Current rating (A) Voltage drop (mv) Current rating (A) Voltage drop (mv) -LN/N -FN -LN/N -FN 30 250 250 55-200 35 250 250 60 200-40 200 200 70 200-45 200 200 80 200-50 200 200 90 200 - Technical data 43-... Voltage rating DC 28 V AC 5 V (400 Hz) upon request Current rating range 30...55 A (-FN2) 30...90 A (-LN2/-N2), Typical life 2,000 operations at x I N Ambient temperature -55...+75 C (-67...+67 F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664A) withstand voltage degree.5 kv 3 Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC,500 V Insulation resistance > 00 MΩ (DC 500 V) Interrupting capacity I cn 6,000 A Interrupting capacity (UL 077) 6,000 A Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 Vibration 0 g (56-500 Hz), ± 0.76 mm (0-55 Hz) to VG 9520, sheet 9, MIL-STD-202, meth. 204, IEC 60068-2-6, test Fc Shock 50 g ( ms) to VG 9520, sheet 28, MIL-STD-202, meth. 23, IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to VG 9520, sheet 2, MIL-STD-202, meth. 0, IEC 60068-2-, test Ka Humidity 240 hours at 95 % RH to VG 9520, sheet 7, MIL-STD-202, meth. 06, IEC 60068-2-3, test Ca Mass approx. 65 g 646 www.e-t-a.de

High Performance Thermal Circuit Breaker 43-... Dimensions Internal connection diagram 43-K4-... OFF ON 2.2.480 7.276.5.059 ø0.6.47 6.5.256 tightening torque max. 4 Nm M2x black white lock washer min.3 min.8 line max. 63 max. 2.48 49.93 55 2.7 max. 64 max. 2.52 2 Typical time/current characteristics 23.906 screw ISO580-M6x8 (-N/-FN) M6x0 (-LN) lock washer DIN 37-B6 tightening torque max. 2.5 Nm 43-K4-LN2 OFF 2.7.06 max. 63 max. 2.48 current rating in A location pin 43-K54-... 2.2.480 ON 7.276.5.059 50 SW4.55 32.26 23.906 screw ISO580-M6x8 (-N/-FN) M6x0 (-LN) lock washer DIN 37-B6 tightening torque max. 2.5 Nm 9.5.374 ø0.6.47 max.9 max.748 6.5.256 max. 3.5 max.38 49.93 55 2.7 max. 64 max. 2.52 max. 3.5 max.38 min. ø3.2 min.26 ø2.5 +0.2.492 +.008 mounting holes 9.5 ±0.2.374 ±.008 tightening torque max. 4 Nm M2x black white lock washer min.3 min.8 thickness.5-3 mm.059 -.8 in. 43-...-FN2 30...55 A Trip time in seconds Trip time in seconds 0000 000 00 0 0. 0.0 0.00 2 4 6 80 20 40 608000 times rated current 43-...-LN2/-N2 30...90 A 0000 000 00 0 0. +75 C +67 F +23 C +73.4 F -55 C -67 F +75 C +67 F +23 C +73.4 F -55 C -67 F 43-K54-FN2/-N2 current rating in A 2.7.06 location pin 50 SW4.55 32.26 9.5.374 max.9 max.748 ø2.5 +0.2.492 +.008 mounting holes thickness.5-3 mm.059 -.8 in. 9.5 ±0.2 min. ø3.2 min.26.374±.008 0.0 0.00 2 4 6 80 20 40 608000 times rated current This is a metric design and millimeter dimensions take precedence ( mm ) inch 2 www.e-t-a.de 646

High Performance Thermal Circuit Breaker 43-... Accessories (approved to VG 95345, part 23) Accessories Splash cover /hex nut assembly with O ring (IP66 and IP67) X 200 80 08 nickel plated nut M2x, transparent cover X 200 80 03 matt black finish nut M2x, black cover X 200 80 2 with blackened nut and transparent cover Identification collar to be snapped on the push button Y 307 004 0 black Y 307 004 02 white Y 307 004 03 red Y 307 004 04 green Y 307 004 05 blue ø4.55 ø6.85.270 M2x 6.4.252 ø2.35.486 Splash cover black /hex nut assembly with O ring (IP54) X 200 802 0 nickel plated nut M2x X 200 802 02 matt black finish nut M2x 0.65.026 M2x Actuator extension (black) to be fitted on the push button X 200 803 0 ø20 ø.787 Lock out ring to block the push button in OFF position Y 307 005 0 red Y 307 005 02 black ø4.6.575 7.7.303 ø0.9.429 7.669 0.8.03 Approvals Authority Standard Rated voltage Current ratings UL UL077 DC 28 V 30 A 90 A CSA QPL Sweden Defence Material Admin. C22.2 No 235 DC 28 V 30 A 90 A TL 5925-00 DC 28 V 30 A 50 A This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 646 www.e-t-a.de 3

4 www.e-t-a.de 646

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: E-T-A Circuit Breakers: X2008008 X2008003