Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Similar documents
INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

INFRARED TAPS. Important: Electronic taps saving water, saving power, promoting hygiene DB100 DB125 DB150 DB175 DBL200 DBL225 DBL250 DBL275

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

Dolphin Blue Infrared Taps

G SERIES - E TOUCH MIXER / TAP

BC632 / BCL632 BC635 / BC635

Acura TMV3 Bath Filler AC50010CP and AC50020CP

DOLPHIN INFRARED TAP DB800 / DB825 TECHNICAL HELPLINE DOLPHINSOLUTIONS.CO.UK DIAMETER PROJECTION TO SPOUT

G2 Optima Plus Flushometer

TOUCH-ACTIVATED URINAL FLUSHING SYSTEM SLIM STYLE PANEL - LARGE (FRONT ACCESS)

3.0 INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

AquaSense TM ZTS6200EV Series

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

HANDS FREE FOOT & KNEE OPERATED TAPWARE

TOUCH-ACTIVATED DUAL FLUSH WC FLUSHING SYSTEM - FRONT ACCESS

Model 0393-(n)* AUTOMATIC DECK MOUNTED FOAM SOAP DISPENSER FOR EZFILL TOP FILL MULTIFEED KIT WITH 1.32 GAL. (5L) CONTAINER EZFILL FOAM SOAP DISPENSER

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

AquaSense ZTR Series

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

Zenith Aqua Sense Taps

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

THERMOSTATIC CONCENTRIC DUAL CONTROL SHOWER VALVES Installation & aftercare instructions

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

Mini Twinline Sequential Shower Valves

1901 Thermostatic Shower Mixer

Installation Instructions

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

Outdoor Bottle Fillers

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

DOLPHIN SOAP DISPENSER

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

ETF-600 Sensor Operated Lavatory Faucet

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Model 0390 EZFILL TOP FILL MULTIFEED KIT WITH 1.32 GAL. (5L) CONTAINER EZFILL KIT* INSTALLATION AND MAINTENANCE GUIDE

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

Installation For Service Only

3.0 INSTALLATION INSTRUCTIONS. Piccolo 21 Single lever Monobloc basin mixers. B0997AA Single lever basin monobloc mixer with long length lever handle,

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

BASYS Infrared Sensor Activated

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

Installation Instructions

Automatic Sensor Tap Installation Manual

LIGATURE RESISTANT SENSOR FAUCET

Maintenance Guide. OPTIMA Components:

Technical Information & Warranty

AquaSense ZTR Series

VIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE: FINISH: VS745 CHR CHROME STYLISH PREMIUM FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Installation Instructions

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Zip FlushMaster Surface mounted sensor

Ebony Extension Tap Range

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Installation Instructions

AquaSense TM ZEG Series

Installation Instructions

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

Prism Floor Standing Bath Shower Mixer

GLOSS WALL BATH SET PRODUCT CODE: FINISH: GS783 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

Instruction Booklet. P.O. Box Berkeley Rd UNANDERRA,NSW 2526 Australia Tel:

OMIKA. it s a personal experience. Installation Guide Wall Mounted Basin Mixer. This instruction booklet covers this model: OMI-109.

APT14 Automatic Pump Trap Installation and Maintenance Instructions

Installation Instructions

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT

Maintenance Information

Mira Mode Shower and Bath Fittings

Sail Extension Tap Range

BARDON T01-C TOUCHLESS URINAL SENSOR INSTALLATION INSTRUCTIONS K-8787T-C02(DC/ ) K-8787T-C04(AC/ ) 18 E

VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT

Glastonbury Tap Range Installation Instructions and User Guide

RUSH WALL TOP ASSEMBLIES EXT D 15MM PRODUCT CODE: FINISH: RU067 MB MATTE BLACK 3/4 TURN OPERATION PREMIUM FINISHES

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

Excel Wall and Deck Mounted Bath Shower Mixers Installation and User Guide

RUSH SHOWER/BATH DIVERTER MIXER PRODUCT CODE: FINISH: RU791 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

Zip FlushMaster Solo Water Saver Urinal Flushing System Keeps Urinals Clean & Reduces Water Wastage

MAC FAUCETS. FA400 Autoluxe Faucets

Installation Instructions

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2" NPT Brass Pipe Plug Adjustable Wrench IMPORTANT!

Milano AUTOMATIC FAUCET

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

MAC FAUCETS. FA400 Wall Mount Sensor

Transcription:

Electronic Concealed Wall Mounted Tap for Premixed Water IR140CP and IR141CP Installation and Maintenance Instructions Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further developments or otherwise. Tel: 01889 207200 Fax: 01889 271172 email: sales@intatec.co.uk web: www.intatec.co.uk Intatec Ltd 2008

Technical Data Power Supply: Internally mounted 9V battery or 9V transformer Power Consumption: 9 to 13 µa Operating Water Pressure: 0.5-8 bar (7-116 psi) Water Temperature: 70 C max Minimum Sensor Range: 80 mm Maximum Sensor Range: 300 mm Flow Time: 5 sec Check contents Before commencing remove all components from packaging and check each component with the contents list. Enure all parts are present, before discarding any packaging. If any parts are missing, do not attempt to install your Inta electronic tap until the missing parts have been obtained. IR140CP and IR141CP Tap Qty 1 x Cover plate Components 1 x Electronic tap body and spout 2 x Allen keys 2.5mm and 4mm 1 x Transformer - only supplied with IR141CP Only IR141CP Pre-Installation Information Warnings Do not install the sensor facing a mirror or any other electronic system operated by an infra-red sensor. To prevent reflection problems, it is recommended there should be a minimum distance of 1.5 m between the flush valve and other objects. 1

Pre-Installation Information Cont. Preparation for Installation Flush water supply lines thoroughly before installing the tap. Do not allow dirt, PTFE tape or metal particles to enter the tap. Shut off the water supply. Important - All plumbing is to be installed in accordance with applicable codes and regulations. Installation The Inta electronic wall mounted tap is for use with premixed water in a concealed installation with access to the valve and pipework from behind or with the valve and pipework sunk into the wall. In order to prevent scalding the water must be premixed using a thermostatic mixing valve. A thermostatic mixing valve with integral isolating valves or a service valve should be installed in the pipework to the tap to allow the water supply to be isolated should servicing be required in the future. 1. Ensure that the water supply is isolated before commencing work. 2. Cut an adequate opening into the wall to accommodate the dimensions of the tap body, outlet pipe and spout and if the IR141CP for the electrical wire. 3. Insert the tap body through the wall opening and assemble the inlet to the water supply pipe in the wall. 4. Connect the outlet to the pipe leading to the spout. The distance from the tap to the spout is approximately 100mm. 5. Mount the tap body and spout to the wall so that it protrudes from the wall as shown below. 6. If the IR141CP place the transformer near to the electricity socket, which can be up to 3m away, and feed the wire through the hole to the shower valve. 7. Turn on the water supply and check the joints for any signs of leakage before proceeding. 8. After the ceramic tiles are installed assemble the cover plate over the shower valve and press to the wall. 9. If the sensor range is unsatisfactory, refer to the section entitled Range Adjustment 158 100 G 1 /2 136 80 2

Adjusting the sensor range without a remote control (Adjust only if necessary) The sensor range is the greatest distance, an object can be from the sensor, to activate the tap. The factory setting should be satisfactory for most installations. If the range is too short (i.e. not sensing users) or too long (i.e. sensing the opposite wall), it may be adjusted as follows: Disconnect the battery or switch off the electricity supply to the sensor. For the IR140CP make a short circuit between the (+) and the (-) connections of the sensor for 5 seconds. A screw driver can be used or any conductive material to make this short circuit. For the IR141CP after disconnecting the power supply, activate the sensor three or four times. Do not make a short circuit on the power supply or on the sensor when the power supply is connected to the sensor. Dis-connect power supply Re-connect the power supply to the sensor. To enter into the adjusting mode, put your hand in front of the sensor at a distance of 5cm (2 ) to 10cm (4 ) within 5 seconds of re-connecting the power supply. Note: If you do not put your hand infront of the sensor after re-connecting the power supply, the sensor will not enter adjusting mode and the previous adjustment will return. When the sensor enters the adjusting mode, with your hand in front of it, the red light will flash slowly. Keep your hand in front of the sensor for 5 sec. until the slow flashing changes to quick flashing. Now move your hand away from the sensor to the required distance and wait until the red light stops flashing. When the red light stops flashing, the sensor has been adjusted to the required distance. Check the new distance and if still unsatisfactory, repeat the procedure. Re-connect power supply Adjusting the sensor with a remote control - optional Hold the remote control infront of the sensor at a distance of about 10cm (4 ). Select the function you want to adjust by pressing the button once. The red light at the front of the sensor will start flashing quickly. You can now make the adjustment by pressing the (-) or (+) buttons, every press will increase or decrease one increment of adjustment. 3

The following can be adjusted using the remote control buttons: Range - The detection range is the greatest distance a person can be located to activate the sensor and is preset at the factory. Press (+) to increase and ( ) to decrease the detection range of the sensor. Flow Time - Security Time# - This function prevents a continuous flow from the tap due to a reflection or if the sensor is covered for more than 90 seconds the water flow will stop automatically, perhaps in the case of vandalism. Press (+) to increase and ( ) to decrease the time. Delay In - On/Off - This function prevents an unwanted activation due to a person passing by without using the tap. The sensor will only be activated if the user is detected for the preset amount of time; press (+) to increase and ( ) to decrease the time. It is recommended for taps, that this function is left at the factory setting. This makes cleaning the basin easier without activating the system. Pressing the button once will prevent the solenoid from opening for one minute. To cancel this function press the on/off button again. Reset - Restores the factory settings. Press and hold the button whilst pressing the (+) button once. Battery Replacement - IR140CP only When the battery starts to runout, the red indicator light will flash at a constant rate. The battery must be replaced within two weeks. Remove the cover plate to expose the joint between the sensor housing and tap. Release the cap screw retaining the housing for the sensor and battery using the 2.5mm Allen key, carefully pull out the battery. Before reassembling the sensor housing ensure that the external O ring has not been damaged, replacing if necessary. Before reassembling the sensor housing to the tap body ensure that the interior of both components is completely dry, use absorbent paper cleaning roll to dry if required. Replace the used battery with a new 9V battery, a Lithium battery is recommended. Reconnect the solenoid valve electrical terminal to the mating terminal of electronic unit. Locater the sensor housing onto the tap body and tighten the retaining cap screw. 4

Maintenance & Spare Parts Filter Cleaning This electronic shower is provided with a stainless steel filter to prevent foreign particles and debris from entering the tap. If the water flow has decreased, this may be due to the filter becoming clogged with debris. The filter can be cleaned as follows: 1. Turn off the service valve in the supply pipe to the shower valve (if fitted) or the isolating valves at the thermostatic mixing valve 2. Remove the cover plate to expose the joint between the sensor housing and tap. 3. Release the cap screw retaining the sensor housing and carefully pull out the sensor housing. 4. Shut off the valve using the 4mm Allen key. 5. Unscrew the filter s cover and remove the filter. 6. Wash the filter under clean running water. 7. Re-assemble the filter into the filter cover. 8. Refit the cover to the filter. 9. Open the valve using the 4mm Allen key and check to ensure there is no water leakage. 10. Refit the sensor housing to the tap and refit the cover plate. Care and cleaning of chrome and special finishes DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or similar chemicals. The use of any prohibited cleaning or maintenance products could damage the surface of the tap and spout. For surface cleaning, use only soap (mild washing-up liquid) and water, then wipe dry with a clean cloth or towel. When cleaning tiled surfaces, the tap and spout should be protected against any splashing of harsh cleansers. Limited Warranty This product is covered by a limited warranty for one year from date of purchase. During this period, Intatec Ltd undertakes, at its option, to repair or replace any faults caused by defective materials or manufacturer that may arise. The guarantee does not cover faults or damage caused by incorrect installation and/or maintenance, wear and tear, battery and water deposits or leakage. This includes, but is not limited to the following: Pressures and temperatures exceeding the recommended limits. Improper manipulation, tampering, bad or lapsed maintenance. Foreign bodies, dirt or scale introduced by the water supply. 5

Trouble Shooting Problem Indicator Cause Solution Water does not come out of the shower head Sensor flashes continuously Low Battery Replace battery Red light in the sensor does not flash when user steps within the sensor s range Range is too short Range is too long Battery is completely used up Increase range Decrease range Replace battery Unit is in Security Mode * Remove article covering sensor Sensor is picking up reflections from mirror or other object. Remove cause of reflection Red light in the sensor flashes when the user steps within the sensor s range Cables between the electronic unit and solenoid are disconnected Debris or scale in solenoid Reconnect the electronic unit to the solenoid valve Unscrew the solenoid, pull out the plunger and the spring from the solenoid and clean them The water pressure is higher than 8 bar Reduce the supply water pressure Water flow does not stop Sensor flashes when the user steps within the sensor s range Debris or scale in piston Clean the piston and orifice Red light in the sensor does not flash when the user steps within the sensor s range Sensor is dirty or covered# Sensor is picking up reflections from mirror or another object Clean or remove cause of interference Decrease the range or remove the cause of the reflection * Security Mode : If the sensor is covered for more that 90 seconds the shower will automatically shut off. Spare Parts List Item Component Component No. 1 Cover Plate 09020007 2 Electronic cap 07020015 3 O ring 04510554 4c Battery connector 4a/7a Solenoid connector 5 Sensor housing cap screw 05020406 7 Solenoid 07500001 10 Inlet olive and nut 07025057 11 Outlet olive and nut 07025057 13 Strainer cover 07055025 15 Strainer 07055026 Intatec Limited Airfield Industrial Estate Hixon Staffordshire ST18 0PF Tel: 01889 207200 Fax: 01889 271172 email: sales@intatec.co.uk web: www.intatec.co.uk