INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

Similar documents
Airfield Industrial Estate Hixon Staffordshire ST18 0PF

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

INFRARED TAPS. Important: Electronic taps saving water, saving power, promoting hygiene DB100 DB125 DB150 DB175 DBL200 DBL225 DBL250 DBL275

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

G SERIES - E TOUCH MIXER / TAP

Dolphin Blue Infrared Taps

DOLPHIN INFRARED TAP DB800 / DB825 TECHNICAL HELPLINE DOLPHINSOLUTIONS.CO.UK DIAMETER PROJECTION TO SPOUT

BC632 / BCL632 BC635 / BC635

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

G2 Optima Plus Flushometer

INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

Installation Instructions

Outdoor Bottle Fillers

ETF-600 Sensor Operated Lavatory Faucet

BARDON T01-C TOUCHLESS URINAL SENSOR INSTALLATION INSTRUCTIONS K-8787T-C02(DC/ ) K-8787T-C04(AC/ ) 18 E

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Basic Parts Description Size Page Stock No.

Acura TMV3 Bath Filler AC50010CP and AC50020CP

AquaSense TM ZTS6200EV Series

AquaSense ZTR Series

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

Aplos Single Lever Basin Faucet

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

MAC FAUCETS. FA400 Wall Mount Sensor

Aquila Single Lever Vessel Faucet

8791T-C02( ) 8791T-C04(AC) 8791T-C04( ) size alkaline batteries(8791t-c02) 2 7 (AAA 2)(8791T-C02) 220V AC 50/60Hz(8791T-C04)

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Prism Floor Standing Bath Shower Mixer

D/G-03 Maintenance. Shutdown Procedure During Freezing Temperatures. Daily. Periodically

TOUCH-ACTIVATED URINAL FLUSHING SYSTEM SLIM STYLE PANEL - LARGE (FRONT ACCESS)

MAC FAUCETS. FA400 Autoluxe Faucets

TWO HANDLE LAVATORY FAUCET

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

Installation For Service Only

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

Ebony Extension Tap Range

HANDS FREE FOOT & KNEE OPERATED TAPWARE

Artisan Professional Mixer

Advisory Bulletin. TB-99 Cleaning and Maintenance For Bobrick B-824 or B-828 Automatic Counter-Mounted Soap Dispensers B-824 B-828

Vertico Sink Mixer. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

STEERING HYDRAULICS The steering system is a flow amplified, load sensing, hydraulics arrangement.

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Artec Pro Single Handle Commercial Kitchen Faucet

Java Basin Mixer Range

TOUCH-ACTIVATED DUAL FLUSH WC FLUSHING SYSTEM - FRONT ACCESS

INSTALLATION INSTRUCTIONS

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

VIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE: FINISH: VS745 CHR CHROME STYLISH PREMIUM FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY

Self Closing Tap. Fitting Instructions & Contents List. Please keep these instructions for future reference and request of replacement parts

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

Glastonbury Tap Range Installation Instructions and User Guide

Seda Single Lever Basin Faucet

4" 4" 4 1/4" 11" TOP VIE 3 1/8" Ø1/2" 2" 10 3/8" SIDE VIE VG05002 THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1/8"

Britt Single Handle Commercial Kitchen Faucet

GP-2000 : Trouble Shooting. Cause of problems

Pneumatic High-Viscosity Filtration System Instruction Manual

Installation Instructions

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Sheven Single Lever Vessel Faucet

Soft Touch Tap Range. Fitting Instructions & Contents List. Please keep these instructions for future reference and request of replacement parts

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTRS30709 rev 1 02/10/09 Page 1

FUEL SYSTEM. Table of Contents. Specifications. Section 3A Fuel Delivery System. Models 6/8/9.9/10/15 CARBURETOR SPECIFICATIONS

Air Operated 1:1 Oil Ratio Pump OP-11

CIRCLE SEAL CONTROLS

New Options Bath Shower Mixer

BASYS Infrared Sensor Activated

Curvare Tap Range. Fitting Instructions & Contents List

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

GLOSS WALL BATH SET PRODUCT CODE: FINISH: GS783 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

D-04/G-04 Maintenance

Operating & Maintenance Manual For Steam Conditioning Valve

AquaSense TM ZEG Series

Aplos Single Lever Vessel Faucet

MAC FAUCETS FA400 WALL MOUNT FAUCETS

DOLPHIN SOAP DISPENSER

3.0 INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

Single Lever Pull-Out Kitchen Faucet

MODEL 1100 TURBINE FLOW METER

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

AquaSense ZTR Series

Excel Wall and Deck Mounted Bath Shower Mixers Installation and User Guide

Ino Single Handle Basin Bathroom Faucet

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

Zenith Aqua Sense Taps

INSTALLATION INSTRUCTION & TECHNICAL MANUAL FLOWMETER

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Transcription:

INFRA RED MONOBLOC (BATTERY OPERATED) SF2601CP INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

INTRODUCTION This installation guide has been produced for the infra red monobloc tap. These instructions cover the installation, operation and maintenance. Please read the enclosed instructions before commencing the installation of this product, please note; WE RECOMMEND THAT THE INSTALLATION OF ANY TWYFORD PRODUCT IS CARRIED OUT BY AN APPROVED INSTALLER The installation must be carried out strictly in accordance with the Water Supply (Water Fitting) Regulations 1999 and any local authority regulations. If in doubt, we would recommend that you contact either your local water authority, the secretary of the Water Regulations Committee at WRc on Tel: 01495 248454 or Institute of Plumbing on Tel: 01708 472791. IMPORTANT When installing the product, care must be taken not to damage/affect the finish of this product. To ensure the finish of this product is maintained, we recommend that this product be cleaned periodically with a soft cloth and mild detergent. The use of any type of abrasive or solvent-based cleaners is not recommended. All products MUST be re-commissioned to suit site conditions to ensure optimum performance levels of the product are obtained. TECHNICAL DATA Power supply: Recommended water pressure: Preset sensor range: Minimum sensor range: Maximum sensor range: Security time: Hot water temperature: Flow restrictor (fitted) Battery box requires 6 off 1.5V AA batteries 1.0 to 8.0 bar (14.5 to 116 psi) With water pressure in excess of 8 bar use with a pressure reducing valve. 220 mm adjustment 80 mm 300 mm 90 seconds 70 C maximum 6 litres per minute (max) 2

CHECK CONTENTS Before commencing remove all components from packaging and check each component with the contents list. Ensure all parts are present, before discarding any packaging. If any parts are missing, do not attempt to install your electronic tap until the missing parts have been obtained. Item Qty Components Part Nos 1 1x Tap and attachments 260300 2 1x Solenoid valve 07230002 3 1 x Filter 08530011 4 1x Battery box 0653019 5 1x IR Sensor 0722004 6 1 x Flow restrictor 6Ltr/min N/A 1 6 5 4 2 3 3

PRE-INSTALLATION INFORMATION Warning Do not install the tap facing a mirror or any other electronic system operated by an infra red sensor. To prevent reflection problems, it is recommended to keep a minimum distance of 1.5m between the tap and other objects. Preparation for installation Flush the water supply pipes thoroughly prior to installation. Do not allow debris, PTFE tape or any metal particles to enter the tap. Turn off the water supply. Important - All plumbing is to be installed in accordance with applicable codes and regulations. INSTALLATION Step 1 - Preparation for mounting the tap 1. Shut off the water supply and remove the hexagonal nut, washer and gasket from the threaded inlet. Step 2 - Installing the tap 1. Position the tap into the hole in the basin or water proof work surface. 2. Slide the gasket over the flexible hose. 3. Secure the tap to the basin or work surface using the hexagon nut and washer. Gasket Washer Hex Nut 4

INSTALLATION Step 3 - Connecting the water supply 1. A service ball valve must be installed in the supply pipe to enable the tap to be isolated for servicing should it be required. 2. Connect the pipe from tap to the solenoid valve and then from the solenoid valve to the service ball valve. Ensure the flow direction through the solenoid valve is the same as indicated by the arrow on the valve body. 3. Ensure the filter is assembled between the inlet joint and the solenoid valve. 4. Turn on the water supply and check for leakage. 5. Isolate via the service ball valve and tighten or remake joints if leakage occurs. Flow Step 4 - Connecting the power supply 1. Install the battery box on the wall under the basin using the screws provided or the two sided adhesive foam tape. 2. Wait a few seconds before activating the tap. 3. If the range is unsatisfactory, refer to the Range Adjustment section. ADJUSTING THE SENSOR RANGE Note: Adjust only if necessary The sensor range is the greatest distance, an object can be from the sensor, to activate the tap. The factory setting should be satisfactory for most installations. If the range is too short (i.e. not sensing users) or too long (i.e. sensing the opposite wall), it may be adjusted as follows: Sensor Disconnect the battery Make a short circuit between the (+) and the (-) connections of the sensor for 5 seconds by connecting together the 2 wires from the sensor. Do not make a short circuit on the sensor when the power supply is connected. 5

ADJUSTING THE SENSOR RANGE Re-connect the battery to restore power to the sensor. To enter into the adjusting mode, put your hand in front of the sensor at a distance of 5cm (2 ) to 10cm (4 ) within 5 seconds of re-connecting the power supply. Note: If you do not put your hand infront of the sensor after re-connecting the power supply, the sensor will not enter adjusting mode and the previous adjustment will return. When the sensor enters the adjusting mode, with your hand in front of it, the red light will flash slowly. Keep your hand in front of the sensor for 5 seconds until the slow flashing changes to quick flashing. Now move your hand away from the sensor to the required distance and wait until the red light stops flashing. When the red light stops flashing, the sensor has been adjusted to the required distance. Check the new distance and if still unsatisfactory, repeat the procedure. BATTERY REPLACEMENT When the battery is ready for changing the red indicator light will flash at a constant rate. The battery must be changed within two weeks. To replace the battery 1. Carefully open the battery box. 2. Remove the old battery. 3. Replace with a new 9V battery, a lithium battery is recommended. 3. Close the battery box. 6

MAINTENANCE Filter cleaning This tap is provided with a stainless steel filter preventing foreign particles from entering the tap. If the water flow has decreased, this may be due to the filter becoming blocked. The filter can be cleaned as follows; 1. Turn off the water supply by closing the service ball valve. 2. Disconnect the solenoid valve from the service valve and dismantle the filter adaptor from it. 3. Remove the filter and wash thoroughly using running water. 4. Reassemble the parts. 5. Re-connect the solenoid valve and turn on the water supply at the service valve. 6. Check to ensure none of the joints are leaking. AFTERCARE INSTRUCTIONS Twyford Bathrooms electronic taps have a high quality finish and should be treated with care. To ensure the finish of this product is maintained, we recommend that this product be cleaned periodically with a soft cloth and mild detergent. The use of any type of abrasive or solvent-based cleaners is not recommended. When cleaning bathroom tiles the tap should be protected from any splattering of harsh cleaners. 7

TROUBLE SHOOTING Problem Indicator Cause Solution No water from tap 1. Sensor flashes continuously Low battery. Replace battery. when user s hands are within sensor range. 2. Red light in the sensor does 1. Range is too short. Increase the range. not flash when the user s 2. Range is too long. Reduce the range. hands are within the 3. Battery is completely The battery must be sensor s range. used up. replaced 4. Unit is in Secure Mode *. 5. Sensor is picking up Eliminate the cause of the reflections from mirror or reflection. other objects. 3. Red light in the sensor 1. Connector between the Connect the electronic unit s flashes when the user s electronic unit and solenoid connector to the solenoid. hands are within the are disconnected. sensor s range. 2. Debris or scale in solenoid. Unscrew solenoid, pull out the plunger and the spring from the solenoid and clean them. Use scale removal agent if required. When replacing the plunger, please ensure that the spring is in the vertical position. * & ** see notes at 3. The central orifice in the Clean the orifice or replace the top of following diaphragm is blocked or diaphragm. page the diaphragm is torn. 4.The water supply pressure is Reduce the water supply higher than 8 bar. pressure. 5. The water supply pressure is Shut off the water supply and under 8 bar and yet the unscrew one of the flexible pressure in the tap s body is pipes in order to release the higher. entrapped pressure. This situation could be caused by a sudden increase in water supply pressure that the check valve or double check valve prevents from dropping, even after the water supply pressure falls below 8 bar. Water flow from the 1. Sensor flashes when the Debris or scale in Clean the orifice or replace the spout does not stop. user s hands are within the diaphragm or the diaphragm. sensor s range. diaphragm is torn. 2. Red light in the sensor does 1. Sensor is dirty or covered Clean or remove the cause not flash when the user s **. of interference. hands are within the sensor s range. 2. Sensor is picking up Reduce the range or remove reflections from a mirror the cause of reflection. or other object. Water flow diminishes Filter or or flow aerator restrictor is is clogged Remove, clean and reinstall. 8

WARRANTY Limited Warranty This product is covered by a limited warranty for one year from the date of purchase. During this period Twyford Bathrooms undertakes, at its option, to repair or replace any faults caused by defective material or manufacturing faults that may arise (see Twyford Bathroom s Warranty). This guarantee does not cover faults or damage caused by incorrect installation and/or maintenance, wear and tear, battery or water composition (eg hard water). this includes but is not limited to the following: Incorrect installation, inversion of supply pipes. Pressure or temperatures exceeding the recommended limits. Improper use, tampering, bad or lapsed maintenance. Foreign bodies, dirt or scale introduced by the water supply. NOTES * Security Mode : If the sensor is covered for more than 90 seconds the tap will automatically turn off the water flow. To return to normal operation remove the obstructive covering. ** Water flow will stop after 90 seconds due to security timing. 9

Twyford Bathrooms Lawton Road Alsager Stoke on Trent ST7 2DF UK UK Technical Helpline Phone: 0870 840 0437 Fax: 0870 840 0438 twyford.technical@twyfordbathrooms.com Installation Instruction No FI 24153 02/09 4/08 10