Please note: upgrades from older fluorescent backlit displays (Q ) will require PMP Adapter Kit #62071 or equivalent

Similar documents
PMP Replacement For Gilbarco Monochrome QVGA Display

INSTALLATION INSTRUCTIONS

Manual No: Revision: B. CCVP Rain Shield. Installation Guide

231 SYE Heavy Duty Short Shaft Kit

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

THE SUBMERGED PUMP SYSTEM SUPPLYING THE DISPENSERS MAY TURN ON UNEXPECTEDLY TO PERFORM A LINE LEAK TEST. THIS MAY RESULT

SB SWITCH CONTROL BOX

Wireless Key Tracker. Locate Lost Keys instantly

Upgrading the Sure Coat Modular Gun Control System

Encore Manual Powder Spray Gun Trigger Switch Replacement

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

IOA Expansion Cabinet. Dual Line Cords Upgrade Instructions

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions

Sentry Battery Charger. Installation and Operations Manual Section 75

PREVIOUS GENERATION. Encore Manual Powder Spray Gun Trigger Switch Replacement. Introduction. Preparation. Gun Disassembly

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

Introduction 1 Important Safety Information 3 Installing TopKAT Series 900 Replacement Report Printer Kit 5

Installing an Auxiliary Pressure Control Module

AEROMOTIVE Part # Subaru Fuel Rails for Top Feed Injectors WRX & STI INSTALLATION INSTRUCTIONS

INSTALLATION. DRIVING LIGHTS for FLHT/FLHX/FLHR BLACK. THANK YOU FOR CHOOSING KϋRYAKYN!

Motorized Stainless 2-Way Valves

Installation. Introduction

Wireless Dimmer Installation and User Guide

Power Fuse Assembly Replacement (for 3000A 1395 DC Drives)

Agilent N5470A Series Oscilloscope Rack Mount Kit

INSTALLATION INSTRUCTIONS

ELECRAFT K3 HIGH-PERFORMANCE METER TRANSCEIVER INSTALLING CRYSTAL I.F. FILTERS. Rev A, October 15, 2007

INSTALLATION ZOMBIE L.E.D. FUEL & BATTERY GAUGE. THANK YOU FOR CHOOSING KϋRYAKYN!

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Purpose This document provides installation instructions for Gasboy 9800A/2600A Pump Interface Kits.

Installation Instructions Studio Makeup Station

231 Transfer Case 2WD Low Range Kit

INSTALLATION INSTRUCTIONS

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

JK Rear Performance Big Rotor Kit

LED Downlight Ceiling Fixtures

EasyStart Installation Instructions for Dometic Family RV A/Cs

Cordless Make Up Mirror WITH ILLUMINATED 1X AND 10X MAGNIFICATION PLUS NIGHT LIGHT

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

SAVE THESE INSTRUCTIONS

SWX-100-INT-PCR Internal Isolation Switch

ROADTHUNDER FAIRING SPEAKER KIT BY MTX, CHROME 2717

Model C230 Pump Controller

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

SAVE THESE INSTRUCTIONS

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Bauer NE Lock OWNER'S MANUAL

VP Remote User s Manual (nvp)

Installation Power Management Unit Battery Cables and Battery Harness

Required Tools and Materials Following tools and materials are required to install the Boot Switch Kit: Nut Driver Heat Gun Thread Lock

Intended Users This manual is meant for Gasboy Authorized Service Contractors (ASCs) who will install this kit on Atlas units.

231-J Low231 4:1 Heavy Duty Transfer Case

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

Thompson Performance, LLC - POWERBLAST PLATE

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

Freedom egen System End-of- Line Functional Checklist

Ford Mustang V6 OEM-Style Fog Light Kit Parts List: Quantity: Tool List:

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

INSTALLATION INSTRUCTIONS

Intended Users This document is intended for Gasboy-certified Authorized Service Contractors (ASCs) and Customer Specified Contractors (CSCs).

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

IMPORTANT INFORMATION

Tension your belts at the speed of light!

Purpose This document provides installation instructions for the Gasboy 9820 Pump Interface Kit.

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

Tactical Laser Illuminator

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Model 3051 Sensor Module Replacement

Electrical Installation

Users Guide for Ac-sync

Firehawk Responder Second Stage Regulator

EVOS M5000 Imaging System

JK 2-Door 2 Stretch Kit Instructions

3 Phase Smart Controller

Thompson Performance, LLC - POWERBLAST PLATE

INSTALLATION INSTRUCTIONS. Upgrade Front Intercooler 2001 Early 2006 Chevrolet / GMC Duramax P/N 2-486

CONV-B2000 Conversion Frame Installation / Inspection Manual Approved Under Dispenser SCCS (Spill Containment & Control System)

Color Logo use on white background only. Red: Blue: PMS Black Logo use on white background only

Rzeppa Factory Replacement CV Joint

Operating and Installation Instructions

Guardian Battery Charger Series. Installation and Operations Manual Section 75

CAUTION. Even Brakes with a black cable need second vehicle kit Even Brakes with a blue cable need second vehicle kit 98450

MoistureMatch A next generation grain tester

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

Operation Instructions

Electrometer Lead Acid Battery Replacement

INSTALLATION. Note: Not all parts will be used in the installation of this product. -cont.-

Installation Instructions BLTR and 2BLTR Relight Assembly

Tachometers and Tach/Hourmeters

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Spare Allen-Bradle. Battery Replacement. Installation Instructions. About This Publication. Catalog Number 2711P-RY2032

LED IMPORTANT SAFETY INSTRUCTIONS

Transcription:

Thank you for purchasing the enclosed PMP retrofit display. This display is designed and manufactured by PMP as a replacement for the Gilbarco Monochrome QVGA Display (M02636A001). The kit includes: (1) LCD (4) Locking Supports (4) #8-32 Thread Forming Screws (4) M4 x 10mm machine screws (1) Adapter plate for EPP applications The Gilbarco monochrome display is used in a number of applications. Depending on your situation, the installation procedure may differ. This guide addresses the three most common upgrades to Advantage and Encore dispensers. Please note: upgrades from older fluorescent backlit displays (Q13287-01) will require PMP Adapter Kit #62071 or equivalent READ THIS GUIDE BEFORE YOU BEGIN Dispensers have both electricity and hazardous, flammable and potentially explosive liquid. Failure to follow the precautions below and instructions in this guide may result in serious injury and death. Follow all rules, codes and laws that apply in your area. PMP shall not be liable for errors contained herein or for incidental or consequential damages in connection with furnishing, performance or used of this publication. PMP reserves the right to change product features or the information contained in this publication. SAFETY PRECAUTIONS FOR INSTALLATION AND MAINTENANCE Only a person with knowledge and experience with gasoline dispensing equipment should perform this work. Barricade the work area with your truck and / or other appropriate means. Always make sure ALL power to the dispenser is turned OFF before you open the dispenser cabinet for maintenance. Physically lock and tag out the circuit breakers energizing the dispenser following OSHA guidelines. Note that more than one disconnect switch may be required to de-energize the dispenser for maintenance and servicing. Use a voltmeter to make sure ALL circuits in the dispenser are deenergized. Failure to do so may result in serious injury. Know how and where to turn OFF power to the submersible pumps in case of emergency. Observe precautions for handling electrostatic sensitive devices and avoid ESD.

❶ Installation in Advantage dispensers This installation outlines the process for replacing an older fluorescent backlit display in an Advantage dispenser. If you are replacing a newer display, some of these steps may not apply to your situation. Adapter Kit #62071 is required for this installation. Begin the installation by opening the dispenser and removing the existing display: Power down the dispenser Power down the Crind Disconnect the data and backlight cables Remove the fluorescent tube to avoid breakage Remove the 2 screws holding the display in place and remove the display Advantage Dispenser Figure 1 - Remove the old display (Q13287-01 by removing the 2 screws shown (fluorescent bulb has been removed for clarity) Figure 2 Mount the Adapter Bracket Reminder: make sure the clear polycarbonate window is in place prior to mounting the Adapter Bracket. Mount the Display Bracket provided in Adapter Kit #62071. Additional #8 hex-head thread forming screws have been provided for your convenience. Locate the 4 Locking Standoffs included with the display Press the Locking Support into the 4 mounting holes in the Display Bezel Figure 3 Install the 4 Locking Supports in the mounting holes in the display bezel.

Ensure the latches are engaged and the Locking Supports are firmly in-place Figure 2 - Be sure to orient the Locking Supports as shown Figure 5 Engage the latching feature. Note: The display was shipped with a protective film over the display. Be sure to remove the protective film prior to mounting. Hold the display with the large connector on the bottom facing you. Align the Locking supports with the mating holes on the Adapter Bracket. Apply enough pressure to engage the Supports. You may feel a snap as the Locking Supports engage. Figure 5 Left side Figure 6 Right side Wiggle the display to ensure the Locking Supports are firmly seated in the Adapter Bracket Re-attach the data and backlight cables Set the DIP switch to the proper position for the correct display orientation (see illustration below).

Figure 7 - Switch location Restore power to the dispenser Switch shown in the Advantage/Encore 300 dispenser (default) position. Verify the switch is set to the proper setting for correct display orientation. ❷ Installation in Advantage dispensers with Encrypted Pin Pads (EPP) This procedure assumes that you will be replacing a newer style (M02636A001) display. If upgrading from an older fluorescent display, refer to step 1. Begin the installation by removing the existing display: Power down the dispenser Power down the Crind Disconnect the data and backlight cables Remove the 4 screws holding the display in-place and remove (see Figure 4). Remove the 3 screws holding the OEM Display Bracket and remove (see Figure 5). Advantage Dispenser with upgraded pin pad Figure 8 Remove these 4 screws to remove the old display Figure 9 Remove these 3 screws to remove the OEM Adapter Bracket

Mount the Display Bracket provided using three screws. Additional #8 thread forming screws have been provided for your convenience. Note the two tabs that will be used to mount the new display Note: The display was shipped with a protective film over the display. Be sure to remove the protective film prior to mounting. Figure 10 - Note mounting tabs Line up the display so the slots at the edge of the bezel mate with the tabs on the Adapter bracket. Slide the display to the right, over the tabs. Secure the display with two screws on the left side of the display. Additional #8 hex-head thread forming screws have been provided for your convenience. Re-attach the data and backlight cables Set the DIP switch to the proper position for the correct display orientation (see illustration below). Switch shown in the Advantage/Encore 300 dispenser (default) position. Verify the switch is set to the proper setting for correct

❸ Installation in Encore dispensers (Encore 500 shown) Begin the installation by opening the dispenser and removing the existing display: Power down the dispenser Power down the Crind Disconnect the data and backlight cables Remove the 4 screws shown to remove the old display. Figure 11- Remove these 4 screws to remove the display Figure 12 - Encore 500 Dispenser Thread two of the M4 screws provided into the standoffs shown in Figure 13. Leave approximately 1/8 of the threads exposed. 1/8 Figure 3 - Install two of the screws provided in the bosses on the right side leaving approximately 1/8"

Line up the display so the slots at the edge of the bezel mate with the screws just installed. Slide the display to the right until you feel the screws reach the detents in the slots. Gently push the display a little harder to the right until the screws pass through the detents. Install two M4 screws on the left side of the display to secure the display in-place. Note: you may need to remove the Rain Shield to access the mounting tabs. Re-connect the data and backlight connectors Set the DIP switch to the proper position for the correct display orientation (see illustration below). Cut-away view of detents Switch shown in the Encore 500 dispenser position. Verify the switch is set to the proper setting for correct display orientation.

Special note regarding Encore 500S dispensers: There are different generations of Encore 500S dispensers. Displays in newer units mount directly to the the door. Some older units will have a sheetmetal bracket which the display mounts (see Figure14). These applications may require a longer cable to stretch across the back of the display. We have included a cable to replace the the OEM CRIND Soft Key cable (M06092A002) if required. ❹ Power up the Crind/Dispenser Power up the Crind and then the dispenser. Check the display operation and orientation. Check for optimal contrast adjustment. Adjust the contrast as necessary. Note: the contrast adjustment method will vary depending on the dispenser type. Refer to the dispenser manual for detailed instructions. If the orientation is wrong, set the DIP switch to the proper position. You must cycle the power to the dispenser for the changes to take effect. Figure 14 - Older Encore 500S with metal bezel. You may need to replace the highlighted cable Troubleshooting / FAQ I want (or do not want) the PMP logo to appear during the dispenser start-up Switch position #2 on S1 is used to determine whether or not the logo appears. o Down position logo will display o Up position logo will not display The image on the display is upside down The PMP Gilbarco Monochrome display is designed to work with Advantage and Encore dispensers. Check to be sure switch S1 is set to the proper orientation for your application. You may also choose whether or not the PMP logo appears during start-up. Here is a summary of the switch combinations: Dispenser Logo splash screen Dip Switch Position S1-1 S1 2 Advantage/Encore 300 ON UP Down OFF Up Up Encore 500 ON Down Down OFF Down Up Note: if you need to change the switch settings, you must cycle the power to the display in-order for changes to take effect. All product or company s names, trade names, trademarks, parts numbers and part descriptions may be the trademarks of their respective owners, and are used for reference or identification purposes only. PMP does not claim any right to or affiliation with such owners. The PMP product described here is manufactured or remanufactured and sold by PMP and is not the product of any other identified manufacturer.