TYPE EE and EEB CENTER- SIDE-BREAK SWITCH TYPE VEE and CBV CENTER BREAK V SWITCH 1200, 1600, 2000 & 3000 Amperes 7.

Similar documents
Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere

AIRBREAK SWITCHES East Ginter Rd. Tucson, Arizona USA (520) Fax (520)

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

TYPE V CENTER BREAK SWITCH

Aluminum Vertical Break Switch kv A.

Copper Double Break Switch

Copper Vertical Break Switch kv A.

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

Product Specifications for Aluminum Vertical Break Switches

Transmission Switching

SPECIFICATION BULLETIN

Disconnect & ByPass Switches

M-Force three-phase switch

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

M-Force three-phase switch

Product Specifications for Phase Over Phase GOABS(r)

Figure 1. HX cutout fuseholders.

Figure 1. HX cutout fuseholders. Positive Interruption

Horizontal Circuit Switchers

Horizontal Circuit Switchers

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

3.0OVERHEAD TRANSMISSION SWITCHES

25 kv Apparatus Bushings

Catalog 14A January 2013

15 kv and 25 kv Thru-Bushings

TYPE BLT DISCONNECT SWITCHES

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

IB-FAS3 Mar Type FAS THRU 115Kv Amp 61 KA Momentary. Vertical-Break, Gang-Operated Outdoor Air Disconnect Switch.

Transmission Switching

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Typical Specification

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

S&C Alduti-Rupter Switches. Outdoor Distribution, 14.4 kv through 69 kv

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Design Standard. Purpose: Design Standard:

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

SECTION PANELBOARDS

S&C Loadbuster Disconnects

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

S&C Recloser Bypass Disconnects

D-73P disconnect and bypass switches

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

INSTRUCTIONS. S&c Circuit-Switchers - Mark v Grounding Switches - 70,000 Amperes Momentary Outdoor Transmission I INTRODUCTION INSTRUCTION SHEET 7 1 1

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Type MOST oil switch

TYPE CBL-T. Copper Center Break V Disconnect Switch kv, 1200A INSTALLATION & INSTRUCTION MANUAL

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Publication No.: PSG

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

Three-Phase Pole Mounted Recloser

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

Installation, Operation and Maintenance Manual

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

Instructions for Installation and Operation

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Submersible Vacuum Fault Interrupters

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

600 A 15 and 25 kv class Cleer grounding elbow

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

AVX. Operation and Maintenance Manual AVX 1200A A 15kV to 362kV. ALUMINIUM VERTICAL BREAK DISCONNECT SWITCH 15kV to 362kV 1200A A

www. ElectricalPartManuals. com

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

Solid Dielectric, Single Phase Recloser

OVERHEAD DISTRIBUTION SWITCHES

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Medium Voltage Metal-Enclosed Switches

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Joslyn Hi-Voltage. Overhead Reclosers & Switches. In this section...

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

S&C Manual PME Pad-Mounted Gear

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

OVERHEAD DISTRIBUTION SWITCHES

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

Lighting and Power Distribution Panelboards

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Range : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions.

GROUP D. Switch & Protective device.

Transcription:

YP and B CNR- SI-BRAK SWIC YP V and CBV CNR BRAK V SWIC 100, 1600, 000 & 3000 Amperes 7.5 through 36 kv YP YP CBV Morpac Industries, Inc. 75 ast Ginter Road ucson, Arizona 85706 50-94-345 FAX 50-94-333 1

ype GNRAL SIGN FAURS he center-side-break switch is a two insulator switch with both insulator stacks rotating for operation. he design of the live parts is essentially aluminum with properly treated copper utilized where necessary to achieve MMCO s time proven concept of silver-tocopper at all moving contacts. he center-side-break when furnished with arcing horns or quick-break attachment can be used for line sectionalizing, by passing circuit breakers or opening magnetizing current of transformers. Without arcing horns it can be used for isolating breakers or as a disconnecting switch. AVANAGS conomical he center-sidebreak is more economical than a vertical-break or a double-side-break switch because it requires one less insulator per phase or three per switch. Self-balancing Inherent self-balancing design eliminates the need for counter-balancing springs except in special applications. Low operating effort Inherent design requires less operating effort for a given rating than an equivalent vertical-break or side-break switch. Contact engagement Full contact engagement easily seen from ground position. INUSRY SANARS he center-side-break switch is designed in accordance with latest industry standards. It is also available when specified based upon past industry standards which limit temperature rise to 30 C over an ambient of 40 C. SWIC OPRAION Opening and closing of the switch is accomplished by rotation of the vertical control pipe. his rotary motion results in a pushpull motion of the interphase of the insulator stack. Both insulators of each phase are rotated simultaneously in opposite directions by the connecting rod between them. When in the open position each blade has moved 90. Morpac Industries, Inc. 75 ast Ginter Road ucson, Arizona 85706 50-94-345 FAX 50-94-333

ype AILS igh-strength, high-conductivity aluminum is used where practical throughout the live parts. Wherever copper-to-aluminum transitions are made the copper is tinned and an oxide inhibitor compound is used to provide an efficient transition. CONACS 100 Ampere Jaw - Partially Open he male contact has a tinned copper bar securely bolted to the aluminum casting welded to the tubular blade. he tinned copper bar has a silver overlay brazed along each make-break surface. he female contact has special, high temperature resistant, copper alloy reverse-loop contact fingers which are bolted to a rugged aluminum jaw casting. Because of the excellent mechanical, electrical and thermal properties of the reverse-loop material there is no need for back-up springs or other pressure compensating devices commonly found on other switches. he reverse loop configuration utilizes the magnetic forces produced during fault conditions to increase contact pressure. 000 Ampere Jaw - Closed Position 000 Ampere Jaw - Partially Open Morpac Industries, Inc. 75 ast Ginter Road ucson, Arizona 85706 50-94-345 FAX 50-94-333 3

ype ING ARRANGMN ING RMINAL PAS he hinge contact is sealed with a non-ageing lubricant. Current transfer is through the threaded contact surfaces of a silver plated copper stud and its mating tinned bronze contact housing. igh pressure is established and maintained by a stainless steel spring, electrically isolated from the current path. his time proven arrangement has been used by MMCO since the mid 1950 s. All ratings of the switch have 4 x 4 aluminum terminal pads with NMA standard 1 3 4 x 1 3 4 drilling for four (4) 1 bolts. erminal Pad Arrangement 4 Morpac Industries, Inc. 75 ast Ginter Road ucson, Arizona 85706 50-94-345 FAX 50-94-333

ype OPRAING MCANISM ach three pole, group operated type switch is furnished complete with an operating mechanism for either manual or motor operation depending on customer specification. Unless otherwise specified by customer, manually operated switches are furnished with a swing handle at 169 kv and below. A 4 kv a worm-gear mechanism replaces the swing handle. LVLING BOLS All switches are furnished with four leveling bolts per bearing to provide fast, effective means of aligning insulator stacks in the field. SWIC BASS Rigid double-channel galvanized steel bases are normally provided on all switches. he rigid trussed construction of the bases assures perfect alignment of the insulators and smooth operation of the switch. An equivalent aluminum base is available when specified. INSULAORS Industry standard station post or cap and pin insulators are normally provided. Others are available when specified. BARINGS ach operating mechanism is designed to fit the customers support structure. Included with the operating mechanism are vertical pipe, connecting rods, interphase rods, outboard bearing, open-close position indicator, flexible ground strap and provision for customer s padlock. Other accessories such as auxiliary switches and interlocks can be provided at an added cost. FIL INSALLAION he simplicity of the center-side-break switch design assures ease of installation and years of trouble-free service. ACCSSORIS Ground switches, quick break attachments, outriggers, spill gaps, along with terminal connectors, motor mechanisms and pole top frames are available on request. Maintenance free stainless steel bearings with stainless steel races within a galvanized housing are provided at the base of each insulator. Morpac Industries, Inc. 75 ast Ginter Road ucson, Arizona 85706 50-94-345 FAX 50-94-333 5

. R. 8 YPICAL NO 5 100-000 amperes erminal pads NO 5 4 7 1 4 1 3 4 4 4 4 3 4 45 G 90 O OP N A NO 3 R. 8 (4) 9 16 ia. oles ach nd Furnished on control phase only 3 1 1 3 4 NOS 3000 AMP RMINAL PAS (1) 916 IA. OLS A1 34 CNRS A. N 1 Standard base shown, others available. NO NO 4 NO 1 4 3 4 (4) 9 16 ia. Mtg. oles pair contact loops furnished for 100 ampere as shown. 3 pair contact loops furnished for 1600 ampere and 000 ampere; 4 pair contact loops for 3000 ampere. 3 Arcing horns furnished only when specified. 4 Insulator leveling screws provided at 69 kv only. 5 = terminal pad thickness s are 58 for 100 amperes, 78 for 1600 and 000 amperes; 58 for 3000 amperes. 5 5 B 5 8 Voltage kv Max. BIL CAALOG NUMBR (1) () (3) Insul. ech. Ref. No. Approximate imensions (Refer to Factory for Certified Prints) A B 8. 15.5 5.8 38 95 110 150 00 7 1P5 15 1P5 3 1P5 34 1P5 5 7 31 16 1 4 16 1 4 16 1 4 16 1 4 7 7 7 7 37 37 37 37 33 33 33 33 1 1 31 61 31 1 48.3 7.5 50 350 46 1P5 69 1P5 67 78 191 4 33 5 5 8 45 43 55 39 51 35 1 41 (1) Catalog numbers shown are with station post insulators. If cap and pin insulators are required, change the P to C in the catalog number (eg.: 7 1C5). () When 30 temperature rise unit is required, omit the in the catalog number (eg.: 7 1P5). (3) Catalog numbers shown are for 100 amps. For 1600, 000, or 3000 amps, change 1 to 16, 0 or 30 in the catalog number as required (eg.: 8. kv 000 A: Cat. No. 7 0P5). Ampere 100A 1600A 000A 3000A Momentary 61 KA 70 KA 100 KA 10 KA ype 8. kv 7.5 kv 100 thru 3000 Ampere 6 Morpac Industries, Inc. 75 ast Ginter Road ucson, Arizona 85706 50-94-345 FAX 50-94-333

R. 10 YPICAL R. 10 NO 5 100-000 amperes erminal pads 4 NO 5 4 7 1 4 45 1 3 4 3 1 G 90. O OP N NO 3 Furnished on control phase only A (4) 9 16 ia. oles ach nd 1 3 4 4 3 4 3000 AMP RMINAL PAS (1) 916 IA. OLS A1 34 CNRS A. N 4 4 3 4 NO 6 NO NOS 1 Standard base shown, others available. pair contact loops furnished for 100 ampere as shown. 3 pair contact loops furnished for 1600 ampere and 000 ampere; 4 pair contact loops for 3000 ampere. 3 Arcing horns furnished only when specified. 4 Insulator leveling screws provided at 69 kv only. 5 = terminal pad thickness s are 58 for 100 amperes, 78 for 1600 and 000 amperes; 58 for 3000 amperes. 6 Corona rings furnished for 30 and 345 kv only. NO 4 NO 1 G (4) 11 16 ia. Mtg. oles 5 B 5 8 1 4 (1 A 1050 BIL) Voltage kv Max. BIL (1) CAALOG NUMBR Insul. ech. Ref. No. () (3) A B Approximate imensions in Inches (Refer to Factory for Certified Prints) G 7.5 350 69 1P5 78 5 5 8 45 55 51 6 46 3 8 11 550 115 1P5 86 33 1 8 60 76 7 6 607 8 145 650 138 1P5 88 39 1 8 7 88 84 6 663 8 169 750 161 1P5 91 45 1 8 84 100 96 6 75 3 8 4 4 36 900 1050 1300 (1) Catalog numbers shown are with station post insulators. If cap and pin insulators are required, change the P to C in the catalog number (eg.: 7 1C5). () When 30 temperature rise unit is required, omit the in the catalog number (eg.: 7 1P5). (3) Catalog numbers shown are for 100 amps. For 1600, 000, or 3000 amps, change 1 to 16, 0 or 30 in the catalog number as required (eg.: 8. kv 000 A: Cat. No. 7 0P5). ype 30 1P5 30 1P5 345 1P5 304 316 367 531 8 96 60 1 8 114 6 3 136 8 108 16 15 Ampere 100A 1600A 000A 3000A 104 1 148 8 7.5 kv 36 kv 100 thru 3000 Ampere 6 8 897 8 3 111 8 3 113 8 Momentary 61 KA 70 KA 100 KA 10 KA Morpac Industries, Inc. 75 ast Ginter Road ucson, Arizona 85706 50-94-345 FAX 50-94-333 7