Ultravar TM AUTOMATIC POWER FACTOR CORRECTION & HARMONIC SOLUTIONS

Similar documents
Low & Medium Voltage Power Factor Correction Capacitors, Harmonic Filters and Line/Load Reactors

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

C1000 Series Automatic Cap Bank

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

CLASS 5870 ReactiVar Power Factor Capacitors AT6000/AT7000 Transient Free Reactive Compensation

Metal-enclosed medium-voltage power factor correction system

Metal-enclosed medium voltage power factor correction system

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

Power System Solutions (PSS)

Power Factor Correction

Welcome. Power Survey International

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

AIR CORE REACTORS. Phoenix Electric Corporation

Beaver Power Factor Correction Capacitors

smartvar Dynamic VAR Compensator

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Power Break II Switchboard

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Ultravar TM. Fixed Power Factor Correction Capacitors & Harmonic Solutions

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

ASCO SERIES 185 Power Transfer Switches

Critical Power Switchboards. Selection and Application Guide

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

Index Low Voltage Network Quality. Low Voltage Network Quality

Power Factor Correction

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

A. This section includes unit capacitors for power factor correction.

Customer Requirements Downtown Secondary Network Service

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

Individual & fixed bank capacitors

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

ABB n.v Power Quality in LV installations

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

CALTRAP INSTALLATION AND OPERATIONS MANUAL

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

Application manual Dry type power factor correction capacitors

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Power factor correction Harmonic filtering Dynamic flicker compensation

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

SWITCHGEAR DIVISION PRODUCT PROFILES

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com

ELG4125: Flexible AC Transmission Systems (FACTS)

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

Horizontal Circuit Switchers

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Horizontal Circuit Switchers

SWITCHED POWER FACTOR AND *********HARMONIC CORRECTION EQUIPMENT MEDIUM VOLTAGE SECTION 16280E

LV Capacitor Bank APC

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

TLE Series UPS 400/500 kw With eboost Technology

PhiCap Capacitors for Power Factor Correction

DYNACOMP. The top-class reactive power compensator

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Power Factor and Harmonics Primer

EMPAC Metal enclosed capacitor bank for wind applications

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

TLE Series UPS 750/1000 kw With eboost Technology

MYRON ZUCKER CALMANUAL POWER FACTOR CORRECTION APPLICATION GUIDE INC.

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

U N I T Y / Three-Phase Uninterruptible Power Systems UT380 and UT Hz

Easy Choice for Energy Efficiency

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

ORION PLUS three-phase kVA

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

LV Capacitor Bank APC

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

TLE Series UPS 160/200/225/250 kw with eboost Technology

Illuminator Series CR NEMA 3R

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

SUBSTATION EQUIPMENT - Page 1 of 8

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

BAC Custom Engineered Controls

Transcription:

AUTOMATIC POWER FACTOR CORRECTION & HARMONIC SOLUTIONS

Contents Benefits of Power Factor Improvement... 4 ACCU-VAR Plus - AVC (50 to 600 KVAR) Standard and Optional Features... 5 240, 480, 600 Volt Equipment... 6 ACCU-VAR Jr. - AVJ (40 to 300 KVAR) Standard and Optional Features... 7 240, 480, 600 Volt Equipment... 8 Demand Line Plus - IDLP (100 to 2400 KVAR)... 9 240, 480, 600 Volt Equipment... 11 Automatic Power Factor Specification Guide... 12 Description: Automatic power factor correction systems are designed to automatically turn power factor correction capacitors on or off to maintain a desired target power factor under varying load conditions on the low voltage distribution systems of industrial, institutional, and commercial facilities. All automatic banks use metallized self-healing capacitors with pressuresensitive interrupters. Applications: Automatic systems, rather than fixed capacitors, should be applied where any of the following conditions occur: Electric utility rates include KVA demand billing or a power factor penalty clause. The facility is experiencing KVA capacity problems causing overheating of system components resulting in increased operating costs and KW usage. The facility is not able to maintain a desired power factor window, especially when extreme fluctuating loads are present. Sustained leading power factor problems are experienced when the electric distribution system is lightly loaded. 3

Benefits Simplified Power Factor Capacitor Applications The automatic power factor correction equipment featured in this catalog monitors the system to maintain the desired target power factor. Information required to correctly size the equipment to the electrical distribution system is the monthly maximum KVAR required, based on the last twelve months usage. Additional system information is required if it is believed that harmonics are present. Reduced Installation Costs Automatic equipment eliminates the need to install smaller capacitor units and associated switching devices on the electrical distribution system, thus reducing installation costs. Enhanced System Reliability Ultravar automatic equipment is application-specific to provide many years of trouble-free operation. The design features that ensure a long service life follow. Engineered air core inductors significantly reduce capacitor inrush current that can result in contactor failures and misoperation of sensitive electronic equipment. Tests have verified that properly designed air core inductors will substantially reduce contactor wear and capacitor switching transients. In addition, individual capacitor stages can be switched in and out by a non-sequential rotational principle. This means the capacitor stage that was switched off last will not be the first stage to be switched on. Each capacitor stage operates for equal periods of time to ensure even wear. The microprocessor-based controller measures the active and reactive currents and calculates the power factor. It automatically switches capacitors as required by plant load to maintain a desired power factor. Its alphanumeric digital display shows power factor, current and capacitor step status. The controller automatically calculates the correct C/K value and adjusts for CT polarity. It is equipped with THD, low power factor, hunting and low/over-voltage visual alarms. Steps can be set for automatic, fixed or off, allowing for the most flexibility when applying a switched bank. The power factor controller utilizes switching time delay and loss-of-voltage dropout features. The time delay protects the capacitors from overvoltage by allowing the capacitor discharge network to drain the voltage before the capacitor is reenergized. The loss-of-voltage dropout disconnects all capacitors if a power failure occurs. After power is restored, the automatic equipment will energize the capacitors, one step at a time, until the desired power factor is again achieved. 200,000 AIC-rated current-limiting fuses specifically designed for capacitors are utilized, providing additional protection from faults that would have to be cleared by an upstream protective device if each capacitor module did not include currentlimiting fusing. The equipment is designed to allow the capacitors to be switched in specified KVAR increments. This feature is especially desirable for close control of the reactive load profile when required to maintain the desired power factor window and avoid utility ratchet clauses. State-of-the-art, low-loss, self-clearing three-phase capacitors are utilized in every automatic system. Each capacitor cell is protected with a UL-recognized pressuresensitive device providing additional protection for the system. All capacitors are UL approved. 4

ACCU-VAR Plus AVC system 240-480 - 600 volts 3 phase 60 Hz Standard Equipment Features Correction to unity power factor, if desired. UL and cul listed. NEMA 1 steel cabinet enclosure with ANSI #70 light grey paint suitable for indoor or outdoor applications. Dust-tight electrical compartment. Dimensions are 48 W x 24 D x 90 H Removable lifting eyes. Safety door interlock to prevent door from being opened while equipment is energized. Microprocessor-based controller with built-in voltage and harmonic alarms provides safe and rapid indication of potential or real failure. Digital display of power factor, current and capacitor step status. Manual switching capability. External current transformer connections provided. 75 KAIC bracing. Capacitor stage display. Air core inductors to limit inrush currents and transients. Industrial duty, UL approved metallized electrode capacitors, employing 200 KAIC currentlimiting fuses in all 3 phases. Plated copper bus. Padlockable door handle. Designed to minimize installation time and costs. Convection cooling - no fans required. Ratings: 300 KVAR maximum at 240 volts 600 KVAR maximum at 480 and 600 volts Optional Equipment Features Blown fuse indicator lights Outdoor NEMA 4/12 enclosure Split core current transformer Molded-case circuit breaker internally mounted with external operator UL listed service entrance Hand-off auto switches 100 KAIC bracing Power on/off switch Bottom entry 5

ACCU-VAR Plus AVC system 240-480 - 600 volts 3 phase 60 Hz Volts 240 480 600 AVC 240 480 600 Volts 3 Phase 60Hz 3 Phase KVAR Weight KVAR Catalog No. Per Step Lbs 50 AVC3050D10 10 928 100 AVC4100D25 25 1050 125 AVC5125D25 25 1099 150 AVC6150D25 25 1149 175 AVC7175D25 25 1198 200 AVC8200D25 25 1248 225 AVC9225D25 25 1298 250 AVC10250D25 25 1347 300 AVC12300D25 25 1446 100 AVC3100F25 25 976 125 AVC3125F25 25 988 150 AVC3150F50 50 1000 175 AVC4175F25 25 1038 200 AVC4200F50 50 1050 225 AVC5225F25 25 1085 250 AVC5250F50 50 1099 275 AVC6275F25 25 1136 300 AVC6300F50 50 1149 325 AVC7325F25 25 1186 350 AVC7350F50 50 1198 375 AVC8375F25 25 1235 400 AVC8400F50 50 1248 425 AVC9425F25 25 1285 450 AVC9450F50 50 1298 475 AVC10475F25 25 1334 500 AVC10500F50 50 1347 525 AVC11525F25 25 1384 550 AVC11550F50 50 1397 575 AVC12575F25 25 1433 600 AVC12600F50 50 1446 100 AVC3100H20 25 976 125 AVC3125H25 25 988 150 AVC3150H50 50 1000 175 AVC4175H25 25 1038 200 AVC4200H50 50 1050 225 AVC5225H25 25 1085 250 AVC5250H50 50 1099 275 AVC6275H25 25 1136 300 AVC6300H50 50 1149 325 AVC7325H25 25 1186 350 AVC7350H50 50 1198 375 AVC8375H25 25 1235 400 AVC8400H50 50 1248 425 AVC9425H25 25 1285 450 AVC9450H50 50 1298 475 AVC10475H25 25 1334 500 AVC10500H50 50 1347 525 AVC11525H25 25 1384 550 AVC11550H50 50 1397 575 AVC12575H25 25 1433 600 AVC12600H50 50 1446 TOP FRONT 3 10 SIDE BOTTOM 1/2 Outline Dimensions (inches) 3 24 16 48 3 16 9 x 1/2 HOLE 47 SCREEN 14 3 2 MIN. INDOOR 10 10 90 CONDUIT ENTRANCE LOCATION NOTE: For blown fuse indicator lights add L to Catalog Number. Refer to Savings & Applications Guide for sizing cables and switches. 6

ACCU-VAR Jr. AVJ system 240-480 - 600 volts 3 phase 60 Hz Standard Equipment Features Correction to unity power factor, if desired. UL and cul listed. NEMA 1 12-gauge steel cabinet enclosure with ANSI #70 light grey paint. Dimensions are 33 W x 16.25 D x 90 H. Removable lifting eyes. Safety door interlock to prevent door from being opened while equipment is energized. Microprocessor-based controller with built-in voltage and harmonic alarms provides safe and rapid indication of potential or real failure. Digital display of power factor, current, and capacitor step status. Manual switching capability. External current transformer connections provided. 50 KAIC bracing. Plated copper bus. LED capacitor stage display. Air core inductors to limit inrush currents and transients. Industrial duty, UL approved metallized dielectric capacitors, less than.2 watts per KVAR losses employing 200 kaic current limiting fuses in all 3 phases. Designed to minimize installation time and costs. Top entry only. Convection cooling - no fans required. Ratings:120 KVAR maximum at 240 volts 300 KVAR maximum at 480 and 600 volts Optional Equipment Features Blown fuse indicator lights Split core current transformer Hand-off auto switches Molded case circuit breaker internally mounted with external operator 60 high model also available - 200 KVAR maximum at 480 volts - designated AVM - contact factory (breaker not available). Power on/off switch 7

ACCU-VAR Jr. AVJ system 240-480 - 600 volts 3 phase 60 Hz AVC 240 480 600 Volts 3 Phase 60Hz Outline Dimensions (inches) Volts 240 480 600 3 Phase KVAR Weight KVAR Catalog No. Per Step (Lbs) 40 AVJ2040D20 20 499 60 AVJ3060D20 20 572 80 AVJ4080D20 20 602 100 AVJ5100D20 20 630 120 AVJ6120D20 20 662 100 AVJ2100F50 50 499 100 AVJ3100F25 25 542 125 AVJ3125F25 25 565 150 AVJ3150F50 50 572 175 AVJ4175F25 25 595 200 AVJ4200F50 50 602 225 AVJ5225F25 25 625 250 AVJ5250F50 50 630 275 AVJ6275F25 25 655 300 AVJ6300F50 50 662 100 AVJ2100H50 50 499 100 AVJ3100H25 25 542 125 AVJ3125H25 25 565 150 AVJ3150H50 50 572 175 AVJ4175H25 25 595 200 AVJ4200H50 50 602 225 AVJ5225H25 25 625 250 AVJ5250H50 50 630 275 AVJ6275H25 25 655 300 AVJ6300H50 50 662 Consult factory for other sizes. 8

Demand Line Plus Demand Line Plus System with Harmonic Suppression Reactors Many of today s power systems require modern solutions to power factor correction. The rapid increase in variable speed drive use and other solid state devices has resulted in severe harmonic loads on power systems. Ultravar has more than ten years of experience in preventing the occurrence of nonsinusoidal resonance. Successful integration in tuned L-C networks solves the problem of parallel resonance. The IDL automatic power factor correction systems with 3-phase harmonic suppression reactors are application-specific. Accordingly, each installation requires specific information to aid Ultravar Application Engineers in designing a system to meet your requirements. This information should include, but not be limited to, KVAR requirements, transformer size and impedance, KVA sc of the transformer, and a harmonic profile of your system. Load characteristics at the time of the survey and worst case should also be included. The IDL systems may be configured for the addition of harmonic suppression reactors in the future to meet the imminent needs of your system. This reduces initial investment and provides a ready made retrofit package. The Demand Line system provides total flexibility in achieving maximum automatic power factor correction. Please contact your Ultravar sales representative for any assistance with your particular power factor correction and harmonic suppression needs. IDLP System 9

Demand Line Plus IDLP System 240-480 - 600 volts 3 phase 60 Hz Demand Line Plus Designed for systems that require large KVAR ratings with and without harmonic suppression reactors. Readily adapted to meet specific requirements. Easily expanded and easy to retrofit with harmonic suppression reactors. Demand Line Plus Features Designed and built to match and line up with motor control centers and switchgear. Industrial rated design and specifications. Dimensions are 90 H x 36 D and each modular section is 24 W. Modular design permits expansion to meet future requirements. Correction to unity power factor, if desired. NEMA 1 steel cabinet enclosure with ANSI #70 light grey paint- 12-gauge frame and 14-gauge panels. Removable lifting eyes. UL and cul listed. Microprocessor-based controller with built-in voltage, temperature, and harmonic alarms provides safe and rapid indication of potential or real failure. Digital display of power factor, current, and capacitor step status. Manual switching capability. External current transformer connections provided. 75 KAIC bracing. Plated copper bus. Top entry. Capacitor stage display. Industrial duty, UL approved metallized electrode capacitors, employing 200 KAIC current-limiting fuses in all 3 phases. Air core inductors to limit inrush currents and transients. Designed to minimize installation time and costs. Door interlock to prevent entry while system is energized. Padlockable door handle (Indoor only). Convection cooling - no fans required. IDLP Optional Equipment Features Blown fuse indicator lights Outdoor NEMA 3R enclosure. Split core current transformer. Molded case circuit breaker internally mounted with external operator or system breaker. UL listed service entrance, 3 wire only. Hand-off auto switches. Reverse layout. Bottom entry. Harmonic suppression equipment. Power on/off switch 10

Demand Line Plus IDLP System 240-480 - 600 volts 3 phase 60 Hz IDLP Volts 240 480/ 600 Ultravar KVAR Weight (lbs) Enclosure KVAR Catalog No. Per Step without reactors with reactors Width (in/mm) 100 IDLP4100D255 25 1094 1634 48 /1219mm 150 IDLP6150D255 25 1223 2033 48 /1219mm 200 IDLP8200D255 25 1352 2432 72 /1829mm 225 IDLP9225D255 25 1417 2632 72 /1829mm 1 250 IDLP10250D255 25 1481 2831 72 /1829mm 1 300 IDLP12300D255 25 1610 3230 96 /2438mm 200 IDLP3200F505 50 686 997 24 /609mm 1 250 IDLP3250F505 50 713 1071 24 /609mm 1 300 IDLP3300FA05 100 740 1145 24 /609mm 1 350 IDLP4350F505 50 1067 1560 48 /1219mm 400 IDLP4400FA05 100 1094 1634 48 /1219mm 450 * IDLP5450F505 50 1132 1760 48 /1219mm 500 * IDLP5500FA05 100 1159 1834 48 /1219mm 550 * IDLP6550F505 50 1196 1959 48 /1219mm 600 * IDLP6600FA05 100 1223 2033 48 /1219mm 650 IDLP7650F505 50 1261 2159 48 /1219mm 1 700 * IDLP7700FA05 100 1288 2233 48 /1219mm 1 750 IDLP8750F505 50 1615 2648 72 /1829mm 800 IDLP8800FA05 100 1642 2722 72 /1829mm 850 IDLP9850F505 50 1680 2848 72 /1829mm 900 * IDLP9900FA05 100 1707 2922 72 /1829mm 1 950 IDLP10950F505 50 1744 3047 72 /1829mm 1 1000 * IDLP10A00FA05 100 1771 3121 72 /1829mm 1 1100 * IDLP11B00FA05 100 1836 3321 72 /1829mm 2 1200 IDLP12C00FA05 100 2190 3810 96 /2438mm 3 1300 * IDLP13D00FA05 100 2255 4010 96 /2438mm 2 1400 * IDLP14E00FA05 100 2319 4209 96 /2438mm 2 1500 IDLP15F00FA05 100 2674 4699 120 /3048mm 2 Larger KVAR sizes available; contact factory for sizes. 1 - Enclosure width increases 24 /609mm w/breaker. 2 - Enclosure width increases 32 /813mm w/breaker. * = Top entry only; consult factory for bottom entry. Notes: For 600 volts - replace F with H. Consult factory for 240 volt applications. 50 KVAR steps available 200 to 2400 KVAR - contact factory representative for part numbers and sizes. Outline Dimensions (inches) 11

Ultravar Power Factor Correction GE Capacitor and Power Quality Products 381 Broadway, Fort Edward, New York 12828-1000 Automatic Power Factor Specification Guide Company Name Address City State Zip Contact Title TEL FAX Description UL cul ACCU-VAR Plus ACCU-VAR Jr. Demand Line Plus Basic Catalog # KVAR Volt Hz KVAR/Step Enclosure Indoor Outdoor Cabinet size Top Entry Bottom Entry Reversed Layout Other Represented by: Options Blown Fuse Lights Circuit Breaker Amps KAIC Loss of KVAR Hand-Off Auto Switches Harmonic Filters (Demand Line Plus series only) Service Entry Required, UL only Other Current Transformer Split Core By Others Ratio :5 Window Contact your local representative.

Ultravar offers other power quality products. For additional information on TVSS, line & load reactors, high voltage capacitor equipment and harmonic solutions, contact your Sales Representative or the address below. Represented by: Ultravar TM GE Capacitor and Power Quality Products DEA-268C 6/7/2002