TECHNICAL DATA/SPECIFICATIONS RATED LOAD: INPUT POWER SOURCE: DRIVE: INTERMEDIATE REDUCTION: FINAL DRIVE: MOTOR CONTROLLER: SPEED: 750 lbs maximum. 110-120 Volt 8 Amp 60 Hz dedicated service. 110-120 Volt 3 Amp 60 Hz battery charger. 1/2 hp motor, 1750 rpm, 90 VDC, continuous duty. VPL-3100B: 1/2 hp motor, 1750 rpm, 24 VDC, continuous duty. VPL-3200B: 1 hp motor, 1750 rpm, 24 VDC, continuous duty. Dual 4L style Poly-V belts and pulleys, 3.94:1 pulley reduction. VPL-3100: 1 dia. ACME screw w/bronze nut and bronze safety back up nut. VPL-3200B: 1.25" dia. ACME screw w/bronze nut and bronze safety back up nut. 24 VAC Relay control. 24 VDC Relay control. 9 feet per minute maximum. 10 feet per minute maximum PERFORMANCE STANDARDS USA FOOD & DRUG ADISTRATION: CLASS II, 510(K) Exempt, File No. 890.3930, Product Code: PCE ANSI/ASME: A18.1-2014 Section 5 Safety Standards for Platform Lifts and Stairway Chairlifts CSA B355-15 Lifts for Persons with Physical Disabilities (Residential Application) ANSI/ASME: CSA B44.1-14/ASME-A17.5-2014 Elevator and Escalator Electrical Equipment SHEET 1 OF 5
BOX (VPL-3100 SERIES) G 36 7/8" BOX (VPL-3200B SERIES) 9 15/16" K L C L OF PLATFORM H J RIGHT HAND UNIT SHOWN VPL-3200B SERIES: SOLID BACKING FROM TOP OF UNIT DOWN 10" (WALL LOADING 200 LBS.) 10" D E HANDRAIL F BETWEEN HANDRAILS B 14 7/8" RAMP UP A 42" SIDE WALLS 2ND HANDRAIL (OPTIONAL) 34" HAND RAIL 34 1/2" CONTROLS *. FLOOR TO FLOOR OF VPL-3175 IS 28" C MAX* FLOOR TO FLOOR SHEET 2 OF 5 NOTES: 1) ACCESS RAMP CAN BE MOUNTED ON EITHER SIDE OF THE PLATFORM 2) SEE ILS-00938 FOR LANDING DETAIL/ALIGNMENT
ANCHOR POINT LOCATIONS/ DETAIL TECHNICAL SPECIFICATIONS FLOOR ATTACHMENT: VPL MUST BE FASTENED TO CONCRETE USING FOUR (4) 1/2" (3/8" BOLT) X IMUM 2-1/2" LONG CONCRETE ANCHORS SUITABLE FOR THE ENVIRONMENT. FOLLOW SELECTED CONCRETE ANCHOR MANUFACTURERS GUIDELINES AND APPLICABLE CODES. FLOOR REQUIREMENTS: 4" THICK 3500 PSI IMUM COMPRESSIVE STRENGTH, REINFORCED CONCRETE. P N 24 5/16" 4 1/8" 39 7/8" Q 3/8" - 3/4" M 33 3/16" 9/16" DIA. HOLE (4) PLACES UNITS WITH STRAIGHT THROUGH PLATFORM SHEET 3 OF 5
BOX (VPL-3100 SERIES) G UNENCLOSED STRAIGHT-THRU PLATFORM (NO PIT) 36 7/8" BOX (VPL-3200B SERIES) 9 15/16" L M C L OF PLATFORM RIGHT SWING PLATFORM SHOWN OPEN H J RIGHT & LEFT SWING PLATFORM S AVAILABLE K RIGHT HAND UNIT SHOWN VPL-3200B SERIES: SOLID BACKING FROM TOP OF UNIT DOWN 10" (WALL LOADING 200 LBS.) NOT SHOWN 10" D E HANDRAIL 14 7/8" CLOSED F BETWEEN HANDRAILS A B 42" SIDE WALLS 2ND HANDRAIL (OPTIONAL) 34" HAND RAIL 34 1/2" CONTROLS *. FLOOR TO FLOOR OF VPL-3175 IS 28" C MAX* FLOOR TO FLOOR NOT SHOWN SHEET 4 OF 5 NOTES: 1) ACCESS RAMP & PLATFORM CAN BE MOUNTED ON EITHER SIDE OF THE PLATFORM 2) SEE ILS-00938 FOR LANDING DETAIL/ALIGNMENT
ANCHOR POINT LOCATIONS/ DETAIL TECHNICAL SPECIFICATIONS FLOOR ATTACHMENT: VPL MUST BE FASTENED TO CONCRETE USING FOUR (4) 1/2" (3/8" BOLT) X IMUM 2-1/2" LONG CONCRETE ANCHORS SUITABLE FOR THE ENVIRONMENT. FOLLOW SELECTED CONCRETE ANCHOR MANUFACTURERS GUIDELINES AND APPLICABLE CODES. FLOOR REQUIREMENTS: 4" THICK 3500 PSI IMUM COMPRESSIVE STRENGTH, REINFORCED CONCRETE. Q P 24 5/16" 4 1/8" 39 7/8" 3/8" - 3/4" RIGHT SWING OPEN R N 33 3/16" 9/16" DIA. HOLE (4) PLACES UNITS WITH STRAIGHT THROUGH PLATFORM WITH PLATFORM SHEET 5 OF 5