Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

Similar documents
Instruction Manual. Vibration Calibrators VC10 VC11 VC12 VC13

Instruction Manual. Vibration Severity Meter VM12

Displacement Sensor. Model 8739, 8740, 8741

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Quick Guide. brite Advanced Retail scale

Ohaus ES Series Bench Scale

Radian Research, Inc. makes no warranty on the accuracy of the information contained in this Operations Manual and accepts no liability for its use.

Slide Measuring Instrument GMG 200

Series 7000 Torque Sensor for PTO-shafts

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Virtual Measurements & Control. VC210 Operators Manual

SEC. SEC America, LLC. Model 7048 DC-DC Converter Rev 1 Owner's Manual

EGQ 212: Duct transducer, CO 2 and temperature

PTC8001 Temperature Calibrator

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

METEOROLOGICAL INSTRUMENTS

L Charger. Instruction manual

Tension Meter. PT Series. Instruction Manual PT-100-L. Valid as of: Please keep the manual for future reference!

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Arm - RX series 170B family

Tension and Compression Load Cell Model 8435

Analog Durometer Model AD-100

UVR-Mi UV-air flow Cleaner - Recirculator

Series 7000 Torque Sensor for PTO-shafts

Battery Charger. Series EASY Charger. User s manual

Caution. Description. Specifications and Ordering Information and Accelerometers

SPC Series. Digital Scale. Operation Manual

LS200 Series Instruction Manual

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Compact Scales. Software Revision V1.25 & above

INTRODUCTION. Specifications. Operating voltage range:

ECONOMISER SERIES E2T USER MANUAL

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Installation and Operation Back-UPS BX550CI-CN

3000 SERIES DRY-BLOCK HEAT SOURCE

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Battery Charger Series EASY Charger

Installation & Calibration

User Guide. Model Insulation Tester / Megohmmeter. Introduction

User Manual Rittal PMC UPS 6kVA

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

KSZ 10B Current Probe Calibrator. Instruction Manual

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

500Z Owner's Manual & Troubleshooting

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Acceleration Sensor AS - 030

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Inclinometer for Electronic Wheel Alignment Machines

Uninterruptible Power System

TPHK Series Immersible Pump

Time Electronics DC Voltage Calibrator. Technical Manual

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

SPG-DIGI. Operating Instruction. Please read carefully before use!

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY

ADN-W L 10. Battery Charger. Instruction manual

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

Installation and Connection: Installation and Operating Manual

Pressure Transmitters

Sonic Meter. Soni. Operating Manual. Rev. A

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R

Arm - TX series 40 family

Signet Pressure Transmitter

PolyStat Immersion Circulators

SPECIFICATION SHEET Pulse tool / Impact Wrench Testing System MODEL : IWT-101

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Load Cell for Manually Operated Presses Model 8451

SEC. SEC America, LLC. Model 680 CE, DC-DC Converter Owner's Manual

Crane Scale. NC Series OWNER S MANUAL

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.

MODEL 908. Read Instructions Carefully! Fuel Gauge CURTIS INSTRUMENTS, INC.

GMD 13 New gravimetric measuring system with evaluation on location

Digital Pressure Regulator Sentronic PLUS Series 614

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

Instruction manual Electric glass door lock Touch-to-open

OPERATION & MAINTENANCE

Catapult 1000 Series Instruction Manual

TABLE OF CONTENTS 6.0 WARRANTY

KSZ 100B Current Probe Calibrator. Instruction Manual

INSTRUCTION MANUAL BATTERY PACK/CHARGER MODEL EM-2112

PRO-SET CC800A Series Programmable Charging Scale CERTIFIED

ENC 150 REFERENCE MANUAL ACU-RITE

TABLE OF CONTENTS. Introduction

HRS305. Hand Rail Scale

Electronic Limit Switch Type

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

TABLE OF CONTENTS 11.0 WARRANTY

Coating Thickness Gauges

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Ball Rail Systems RE / The Drive & Control Company

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

MityFlex Peristaltic Pump

Rotary Heat Exchangers

OPERATING MANUAL PLS HLE 1000 PACIFIC LASER SYSTEMS. The Professional Standard

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Transcription:

Instruction Manual Vibration Calibrator VC20 Manfred Weber Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str. 58 - D-01445 Radebeul Tel. +49-351 836 2191 Fax +49-351 836 2940 Email: Info@MMF.de Internet: www.mmf.de

Manfred Weber Metra Mess- und Frequenztechnik in Radebeul e.k. Meißner Str. 58 D-01445 Radebeul Tel. 0351-836 2191 Fax 0351-836 2940 Email Info@MMF.de Internet www.mmf.de Notice: The current version of this document can be found as PDF at http://mmf.de/product_literature.htm Specification subject to change. 2010 Manfred Weber Metra Mess- und Frequenztechnik in Radebeul e.k. Full or partial reproduction subject to prior written approval. Jul/ 16

Contents 1. Purpose...1 2. Properties...1 3. Operation...1 3.1. Attaching the Test Object...1 3.2. Calibration...1 3.3. Charging the Accumulator...1 3.4. Reset...1 4. Calibration...1 5. Technical Data...1 Appendix: Warranty CE Declaration of Conformity

Thank you for choosing a vibration calibrator from Metra! 1. Purpose Easy and simple calibration of vibration metering, recording and control equipment Regular checks of such devices and installations Fault finding 2. Properties Handy and robust battery device for laboratory and field use Load-independent vibration magnitude with an RMS of - 10 m/s² vibration acceleration - 10 mm/s vibration velocity - 10 µm vibration displacement Quartz stabilized vibration frequency of 159.15 Hz (radian frequency 1000/s) Suitable for test objects weighing up to 600g The vibration calibrator VC20 generates mechanical vibrations with quartz stabilized frequency and precisely controlled magnitude. Vibration sensors, including connected cables, signal conditioners and readout instruments can be calibrated in acceleration, velocity or displacement units. A reference accelerometer inside the shaker head and a control circuit keep the vibration level constant and independent of the weight of the attached measuring object. A display indicates the error in percent. There is an acoustical warning when the error limit is exceeded. Because of its internal rechargeable battery, the VC20 is well suited for mobile applications. The instrument features an automatic switch-off function preventing accidental discharging. The display indicates the battery charging condition. The unit comes with an external mains supply for charging. The supplied plastic carrying case allows convenient handling and safe transport. 1

3. Operation 3.1. Attaching the Test Object The vibration exciter of the VC20 has a tapped M5 hole with 7 mm depth for the attachment of the device under test. The supplied stud bolts and stud adapters or a clamping magnet can be used for mounting. The surface of the vibration exciter has been made extremely resistant by plasma nitride coating. For light transducers, adhesive wax or double sided adhesive tape can be used for mounting. A flat surface for adhesive mounting can be obtained by using the M5 insulating flange Model 029 which is available from Metra. Magnetic and adhesive attachment are only allowable for roughly estimated calibrations. Accuracy is only guaranteed for screw attachment. When mounting the specimen, pay attention to the symmetrical distribution of the object weight. Otherwise, the vibrating system may be deflected from its main axis. When using coupling structures for calibration of transducers, symmetrical attachment becomes especially important, for instance, at the calibration of the x and y axis of a triaxial accelerometer. In this case, using a balance weight as shown in the following illustration is recommended. Correct: Incorrect: Figure 1: Load balancing Please note that heavy connecting cables should be supported close to the test object. However, an application of force via the cable must be avoided. The maximum torque rating of 1 to 2 Nm at the vibration exciter must not be exceeded since this may damage the instrument. The VC20 should be placed on a rigid surface. Hand-held operation is not recommended because of possible errors. 2

3.2. Calibration After attaching the device under test switch the VC20 on by depressing the On/Off button until the display lights up. Device information, such as hardware and software versions and the date of the last calibration, is displayed for a few seconds. After short time the vibration signal becomes stable. The display shows the values of vibration frequency and magnitude (Figure 2). Please note that these are not measuring values but only nominal values. Figure 2: Display in calibration mode In the upper right hand corner you will see the actual accuracy of the vibration magnitude in percent. After short period of time the percent value should converge on zero. If the absolute error exceeds 3 %, the percent value will change to inverse characters and a beep sound will be generated. In this case no calibration can be performed. When the maximum weight of the test object is exceeded, instead of the percent value, an error message OVERL will appear and the shaker will be switched off. To proceed with calibration, first switch the calibrator off. Then reduce the weight of the test object and switch the calibrator back on. The admissible weight is up to 500 grams, depending on the selected frequency. The overload message can also be eliminated by lowering the vibration magnitude. In the lower display line the date of the last calibration of your VC20 is displayed. This entry can only be modified during factory calibration. Please read also section 5 for details about calibration. The VC20 can be switched off by depressing the ON/OFF key for at least one second. Should this be omitted, a timer is provided which switches the calibrator off after 10 minutes. Caution: The vibration calibrator is not to be used in dirty and dusty environments. Particular care should be taken that no ferromagnetic particles get inside of the instrument. They may damage it within short time. Defects due to dirt and dust are not covered by the warranty. 3

3.3. Charging the Accumulator The battery indicator is located in the upper left hand corner of the display. A full bargraph is displayed when the battery is fully charged. Even if the bargraph is empty the instrument can still be used within its specifications for a certain period of time. When the battery voltage drops under a critical value, the VC20 is switched off automatically. The instrument is equipped with a NiMH accumulator providing power for approximately 5 hours of operation. To charge the battery, connect the supplied mains plug adapter (15 VDC) to the DIN socket at the side of the case. The unit should preferably be switched off during charging. Charging will take about 3 hours. During the charging process the battery indicator will be continuously moving (Figure 3). During the charging process the VC20 can be used for calibration. However, this will extend the necessary charging time. The accumulator should be charged at room temperature. At higher temperatures charging can be stopped before reaching the full capacity because of the built-in temperature sensor. The battery has no memory effect. Partial charging is permissible. Permanent connection of the mains adapter is not recommended. This may lead to premature wear of the battery. In order to avoid overcharging the battery, it is not recommended that you disconnect and connect the mains adapter again immediately after charging is finished. When the unit is not in use, the battery should be charged at least once a year. The built-in battery is maintenance-free. Like all accumulators it has a limited number of charging cycles. If the operating time with a fully charged battery becomes in - sufficient, the battery should be replaced. In this case, the calibrator should then be returned to the manufacturer. In addition to replacing the battery, the manufacturer will also test the accuracy of the calibrator. 3.4. Reset Figure 3: Charge indication In the unlikely event that your VC20 cannot be switched on by the On/Off key, it may be necessary to press the Reset button. This button is found on the bottom side of the case near the key pad. Use a thin non-metallic object, such as a toothpick, to press the button inside the hole. This will start the instrument. Pressing the Reset button has no effect on accuracy. 4

4. Calibration The vibration characteristics of the VC20 are very stable even after intensive use. Typical changes are below 1 % per year. We recommend annual re-calibration. In case of shock load, dropping the instrument, etc. immediate recalibration is advised. 5. Technical Data Vibration magnitude (RMS values): Vibration acceleration: 10 m/s² ± 3% at 0 to 40 C Vibration velocity: 10 mm/s ± 3% at 0 to 40 C Vibration displacement: 10 µm ± 3% at 0 to 40 C Vibration frequency: 159.15 Hz ±0.05% at -10 to 55 C Radian frequency: 1000 /s ±0.05% at -10 to 55 C Level indication: Settling time: Maximum weight of test object for stated accuracy: Percent display, above ± 3 % beep tone < 10 s 600 g Vibration exciter: Dynamic force: Max. torque: Nominal torque: Max. transverse force: Transverse vibration: Mounting of test object: Operating temperature ranges for: 3% accuracy 5% accuracy Humidity: 10 N 2 Nm 1 Nm 20 Nm < 10 % of main axis, measured 14 mm above shaker M5 tapped hole, 7 mm deep clamping magnet adhesive 0 to 40 C -10 to 55 C < 90 % at 30 C, no condensation 5

Magnetic scatter field at shaker: Power supply: Battery operating time: Automatic shut-off time: Charge time of accumulator: < 0.2 mt built-in NiMH accumulator, 7.2 V / 1.6 Ah approx. 5 h with m = 100 g 10 min 3 h Charge socket: DIN 45323 (5.5 / 2.1) positive terminal at center pin Charge voltage: Charge current Dimensions (length x width x height): Weight: 11 to 18 V DC < 1 A 100 x 100 x 120 mm³ 2.2 kg 6

Limited Warranty Metra warrants for a period of 24 months that its products will be free from defects in material or workmanship and shall conform to the specifications current at the time of shipment. The warranty period starts with the date of invoice. The customer must provide the dated bill of sale as evidence. The warranty period ends after 24 months. Repairs do not extend the warranty period. This limited warranty covers only defects which arise as a result of normal use according to the instruction manual. Metra s responsibility under this warranty does not apply to any improper or inadequate maintenance or modification and operation outside the product s specifications. Shipment to Metra will be paid by the customer. The repaired or replaced product will be sent back at Metra s expense. Declaration of Conformity According to EMC Directive 2014/30/EC Product: Vibration Calibrator Type: VC20 (from Ser. no. 160000) It is hereby certified that the above mentioned product complies with the demands pursuant to the following standards: DIN EN 61326-1: 2013 DIN EN 61010-1: 2011 DIN 45669-1: 2010 The producer is responsible for this declaration Metra Mess- und Frequenztechnik in Radebeul e.k. Meißner Str. 58, D-01445 Radebeul declared by Michael Weber Radebeul, April 22, 2016 7