FINHRM FINHRM5 FINHRMA FINHRMAC

Similar documents
INTRODUCTION ZONE CHARACTERISTICS SURGES

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

PQstorI One stop solution for energy storage and power quality

TECHNICAL DATA SHEET KVA UPS Systemss

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

PQdynaC High speed, flexibility and modularity

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Power Quality. Static Var Generator (SVG) SVG Wallmount & SVG Cabinet Mount

MASTERYS IP+ 10 to 80 kva

Liebert. FP 50Z kva

Technical Data Sheets

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Power Protection Discrete Automation & Motion South Africa

POWER kva

Power Quality Solutions

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

LV Capacitor Bank APC

ABB central inverters ULTRA-750/1100/ kW to 1560kW

Technical Data Sheets

Technical Data Sheets

PQactiF Higher flexibility and modularity for improved power quality

POWER kva

&MFDUSJGJDBUJPO Products 1PXFS 2VBMJUZ 'JMUFST 12'* o 12'. o 12'4 )BSNPOJDT NJUJHBUJPO MPBE CBMBODJOH BOE SFBDUJWF DPNQFOTBUJPO PO -7 OFUXPSLT

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

LV Capacitor Bank APC

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

TLE Series UPS 400/500 kw With eboost Technology

Technical Data Sheets

EFFEKTA Power Supplies

Technical Data Sheets

MGE TM Galaxy TM 7000 GFC

Three Phase UPS Systems Range: 10 to 500kVA

SUN INGECON. Box 220 / 275 / 300 / 320 / 345 / 360 Vac. M220 / M275 / M300 / M320 / M345 / M360 Outdoor.

D Series: UPS UPTO - 300KVA - Three / Three Phase

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

500 / 630 / 720 / 760 / 800 / 850 / 900

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

TLE Series UPS 750/1000 kw With eboost Technology

Technical Data Sheets

Unrivalled in Power Factor Correction.

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

PowerValue 11/31 T kva

Technical data sheets

smartvar Dynamic VAR Compensator

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TLE Series UPS 160/200/225/250 kw with eboost Technology

Power Conversion System The Best Technology for your photovoltaic and storage system

ABB central inverters PVS to 1000 kw

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Power IT LV Active Filters PQFI - PQFM PQFK - PQFS

Technical Data Sheets

Technical data sheets

Qingdao Zener Electric Co., Ltd

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

PowerWave 33, kw

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

HYBRID INVERTERS for Energy Storage Systems. Renewable Energy on demand

APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Technical Data Sheets

CTU 02. Thyristor switching module for fast PF compensation. User manual

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

CNW Hz REOWAVEpassive - harmonic filter 60 Hz/480 V (IP20)

ABB central inverters PVS to 1000 kw

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

PQC - STATCON The ultra fast Power Quality Compensator

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Automatic capacitor banks

POWERTRONIX QUASAR 5-40 KVA

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

PowerScale kva Technical Specifications

Power Factor Correction Capacitors in sheet steel cases

Versatile and Powerful. Liduro Wind Frequency Converter System

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

PowerScale TECHNICAL SPECIFICATIONS

MKN-DSP SERIES - THREE PHASE

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

ABB central inverters PVS to 2091 kva

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

RLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

CONTAINER 1MWh. CONTAINER 1 MWh. Electrocell presents the INNOVA 1MWh on/off-grid energy storage system.

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Transcription:

HARMONIC FILTERS

Power quality is a significant concern for manufacturing and power generation facilities. This is due to harmonic disturbance and reactive power, which is produced by unbalanced loads, variable frequency drives and motors. These issues have serious consequences, including prematurely aging of equipment, unreliable controls, system synchronization loss, and increased energy, maintenance and replacement costs. Enerdoor is an industry leader in radio frequency interference solutions. The Enerdoor harmonic filter series solves harmonic disturbance and power quality issues by compensating current harmonic and power factor correction generated by industrial loads. FINHRM FINHRM5 FINHRMA FINHRMAC Example of a distorted drawn current due to a 6P rectifier Example of a sinusoidal drawn current Problems generated by harmonic and displacement power factor Both harmonic distortion and displacement power cause the following problems in an installation: Over sizing of power cables, transformers and generators to support higher currents due to reactive energy Voltage harmonic distortion due to an unbalanced load propagated to other loads in the installation Disruptive resonance with other reactive components on the same power line Higher utility costs due to kvar returning to the mains Communication interference Energy loss The majority of automation systems and manufacturers are required to follow the IEC 61000-3-2, IEC 61000-3-12 and IEEE 519 International Standards which regulate harmonic distortions in the mains. Passive Harmonic Filters Enerdoor passive harmonic FINHRM and FINHRM5 series attenuates the distorted current and is connected in series to the load (normally 6 pulse rectifier) without causing a significant voltage drop. Active Harmonic Filters Enerdoor active harmonic FINHRMA and FINHRMAC series eliminates harmonic distortion due to nonlinear loads and improves power factor by minimizing reactive power generated by the load. These models are connected in parallel to the mains to compensate the harmonic distorted current.

PASSIVE HARMONIC FILTERS FINHRM5 ELECTRIC CHARACTERISTICS Nominal voltage Up to 480 Vac Peak current @ 50 C 150% for 60 s every 10 minutes Frequency 50 Hz (.6 for 60 Hz) Case Enclosure or open frame THDI reduction <5% Overvoltage on no load condition <5% Reactive power on no load 25% FINHRM5 Current (A) @ 50 C Rated Power (KW) 400 Vac Rated Power (KW) 480 Vac Power Loss (W) 400 (480) Vac ELECTRIC CHARACTERISTICS Nominal voltage Up to 480 Vac (600 optional) Peak current @ 50 C 150% for 60 s every 10 minutes Frequency 50 Hz / 60 Hz Case Enclosure THDI reduction <15% Overvoltage on no load condition <5% Connection FINHRM5.010.M 10 4 5.5 55 (80) Terminal blocks FINHRM5.016.M 16 7,5 11 105 (160) Terminal blocks FINHRM5.032.M 32 15 18,5 210 (275) Terminal blocks FINHRM5.045.M 45 22 30 273 (370) Terminal blocks FINHRM5.080.M 80 40 48 398 (475) Terminal blocks FINHRM5.120.M 120 60 72 492 (672) Terminal blocks FINHRM5.160.M 160 80 96 590 (710) Lugs FINHRM5.210.M 210 105 126 610 (750) Lugs FINHRM5.260.B 260 130 160 780 (940) Busbars FINHRM5.320.B 320 160 200 940 (1150) Busbars FINHRM5.400.B 400 200 241 940 (1150) Busbars FINHRM5.460.B 460 230 277 1280 (1410) Busbars FINHRM5.600.B 600 280 360 1480 (1750) Busbars FINHRM5.750.B 750 360 440 1690 (1920) Busbars FINHRM FINHRM Current (A) @ 40 C Rated Power (KW) 400 Vac Rated Power (KW) 480 Vac Power Loss (W) 400 (480) Vac Connection FINHRM.016.M 16 7,5 11 80 (116) Terminal blocks FINHRM.030.M 30 15 18,5 97 (145) Terminal blocks FINHRM.050.M 50 25 34 170 (250) Terminal blocks FINHRM.075.M 75 37 45 225 (335) Terminal blocks FINHRM.100.M 100 50 68 257 (380) Terminal blocks FINHRM.150.M 150 75 90 320 (480) Terminal blocks FINHRM.200.M 200 100 120 575 (850) Terminal blocks

FINHRMAC Compact Active Harmonic Filter High performance and reliable High efficiency: harmonic filtering rate more than 95% Touch screen LCD HMI Easy installation Unaffected by network conditions Active load balancing Combination of power factor and harmonic correction (both inductive and capacitive power) Free from resonance due to automatic resonance elimination Complete protection for: over voltage, under voltage, over current and over heating Paralleled up to 10 modules Rack unit or wall mounting installation options TECHNICAL SPECIFICATIONS Active Filter Rating HRMAC.030.M HRMAC.N.030.M HRMAC.050.M HRMAC.N.050.M Grid type 3 phase 3 phase plus neutral 3 phase 3 phase plus neutral Rated AC current 30A 30A 50A 50A Rated voltage 380 480 Vac (± 10%) Rated frequency 50 / 60 Hz (± 1%) Power consumption 1 Kw 1.5 Kw 1 Kw 1.5 Kw Residual THD(I) <5% Output ability 100% Self limited Harmonic order 2 nd - 50 th Full response time 10 ms Response time 100 µs Neutral compensation current 300% 300% CT ratio 500:5 ~ 5000:5 HMI Touch screen panel Communication RS 485 Parallel configuration Up to 10 units Protection level IP 30 Cable entry Back Mounting Rack or wall mount Dimensions WxHxD (mm) 482 x 176 x 600 482 x 176 x 650 482 x 176 x 600 482 x 176 x 600 Weight 26 Kg 26 Kg 28 Kg 28 Kg

FINHRMA Active Harmonic Filter Active Mode - Fast adaption of output currents, according to the actual harmonic and reactive conditions of the load. Power Factor Correction - Compensates the load reactive power and brings the power factor to the target value. Immunity - Any harmonic current injected into the line by nearby user equipment. Does not affect filtering effectiveness and is not influenced by any line voltage distortion. No Resonance - Operation principles prevent undesired oscillations. Zero Absorption - The active power absorbed by the line is restricted to the loss of the power section (inverter, conductor, cables). The active filter generates only harmonic and reactive currents without any exchange of energy with the mains. Ease of Installation - The active filter is connected in parallel with the supply line. The load current is monitored by current transformers (CTs) installed on the load side. Ease of Disconnection - Active filters may be disconnected from the supply line simply by switching off the main breaker without interrupting the supplied load. TECHNICAL SPECIFICATIONS Active Filter Rating FINHRMA.075.M FINHRMA.100.M FINRMA.200.M FINHRMA.300.M Grid type 3-phase / 3-phase + neutral available as an option Rated AC current 75A 100A 200A 300A Rated voltage Up to 690 Vac Rated frequency 50 / 60 Hz (± 1%) Residual THD(I) <5% Power factor correction Up to 0.95* Response time <300 μs CT ratio 100:5 ~ 50000:5 HMI Touch screen panel Controller topology Digital with FTT analysis Available interface protocols Ethernet, RS485, ModBus Parallel configuration Up to 5 units Protection degree IP 31 Cable entry From the bottom Mounting Cabinet Dimensions WxHxD (mm) 820 x 2200 x 610 1220 x 2200 x 610 Color RAL 7035 Cooling Air cooling Operative temperature range Operating: 0 C / 40 C and Storage: -10 C / 50 C Humidity <80% @ 20 C not condensing Altitude <1000m a.s.l. *Maximum power factor compensation capability depending on compensation current

Transformers and Line Reactors RFI Filters Voltage Stabilizers Surge Arresters Motor Protection

USA ENERDOOR Inc Toll Free 1-877-778-2875 Phone 1-207-210-6511 Fax 1-207-210-6512 info@enerdoor.com www.enerdoor.com GERMANY ENERDOOR Gmbh Phone +49 (0) 6642 223692 Fax +49 (0) 6642 223558 info@enerdoor.de www.enerdoor.de 10-2015 SWITZERLAND ENERDOOR SA Phone +41 (0) 91 9228060 Fax +41 (0) 91 9228061 info@enerdoor.ch www.enerdoor.ch ITALY FINMOTOR Srl Phone +39 02 4891 0020 Fax +39 02 4891 0053 info@finmotor.com www.finmotor.com HUNGARY EICHHOFF ELEKTRO Kft Phone +36 27 511180 Fax +36 27 511187 info@eichhoff-elektro.com www.eichhoff-kft.com