Power units. Hydraulic power units. hydraulic hydraulic hydraulic. hydraulic hydraulic

Similar documents
AccessoriesAccessories

ZE3 & ZE4 Electric 1 & 1 1/2 HP Pump Series

3/2 and 4/2 directional poppet valve with solenoid actuation

/2017. Hollow piston cylinder, single-acting spring clamping hydraulic unclamping

Hydraulic clamping elements

Directional Control Valves. Features. Application. Operation

/2017. Swing sink clamping element double-acting

Differential Lock Valve

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves. General Description. Operation. Features

3/2 and 4/2 directional seat valves with solenoid actuation

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve

Grease Lubrication Pump FK

Proportional pressure reducing valve, 3-way variant, pilot operated

3/2-way Solenoid Valve for pneumatics

3/2 and 4/2 directional seat valves with solenoid actuation

Monarch D.C. Hydraulic Power Systems. Comprehensive information may be found on the page referenced below each selection category.

Power Workholding. Power Workholding n Precision Vises n Zero Point Mounting n Assembly and Handling

Series 20 Axial Piston Pumps. Technical Information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Open center control block in mono block design MO-16, 22, 32

Monobloc and Sectional Directional Control Valves

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

Air Valve AIR-PILOTED VALVES

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

Monobloc and Sectional Directional Control Valves

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Monobloc and Sectional Directional Control Valves

Series 20 Axial Piston Pumps. Technical Information

Fixed Displacement Motor A2FM

Modular pneumatic valve unit

Clamping and drive module

400 psi (28 bar) PDI & INJ. 100 psi (7 bar) PDI & INJ

ENERPAC hydraulic valves are available in a wide variety of models and configurations.

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Hyva Valves Introduction

LUDV control block of sandwich plate design

B8_58 (EDBZ-VEI) RE Edition: Replaces:

Proportional Directional Valve System

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

Single-circuit power brake valve LT 05

5 Port Solenoid Valve

5 Port Solenoid Valve

APV Load Sensing Valve

Directional Control Valves

Proportional pressure reducing valve of 3-way design

P O W E R P U M P S SECTION INDEX. Proper Size & Selection G1 Series Electric...

Control Reliable Double Valves with Total Dynamic Monitoring & Complete Memory

Directional Control Valves

Airmatic Lubricator. Pneumatic Operation, Oil. General. Application. Operation. Technical Data

5 Port Solenoid Valve

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES

Proportional pressure reducing valve, in 3-way version

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Differential Lock Valve

Die changing technique

POWER PUMPS. G1 Series - Electric. SUC-O-MATIC VALVE The 3 position / 3 way Suc-OMatic valve draws hydraulic oil. Power Pumps

Axial Piston Variable Pump A15VSO

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Series 20 Axial Piston Motors. Technical Information

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Pilot operated pressure relief valve

MODEL 10LH SPECIFICATION

/2-way piston valves

Modular pneumatic valve island

Hydraulic Jacks & Tools Valves

Motors & Pumps- Hydraulic Pumps, Motors & Power Units

Size 06 (D03) Q max 100 l/min (26.4 GPM) p max 250 bar (4600 PSI) RPE*-06 PRM*-06

Output Flow Pump at 700 A B C D E F Prod. Wt. No. bar (mm) (mm) (mm) (mm) (mm) (mm) (kg)

Monobloc and Sectional Directional Control Valves

Directional Controls

Filter/Cooler Module. Advantages: RA 50127/ /12 Replaces: Model MFC3, MFN3, MNC3

Axial Piston Variable Pump AA4VG

Proportional Valves. Proportional solenoid valves for pressure and flow control

LECTURE 24 TO 26 - HYDRAULIC CIRCUIT DESIGN FREQUENTLY ASKED QUESTIONS

Pump Safety Block Model DBA... / DBAW, Series 1X

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

Direct Operated Type Solenoid Operated Proportional Throttle Valve

Modular Hydro-Pneumatic Suspension System Improving Suspension Performance with a Proper Setup: Quicker and Better Adaptation to Applications

Fixed Displacement Plug-In Motor A2FE

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces:

Meter-in pressure compensator, direct operated

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

Series 20 Axial Piston Motors. Technical Information

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces:

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

VALVES. V44/V45 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 26 mm

Section 7.1. Wheel Drive Circuit - General System

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Section 9: Centralized Lubrication Systems

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

ZRV. Direct Operated Check Valve Series ZRV (Denison)

Directional Controls

Low Profile J Series Power Unit with Vane Pump

Direct Operated Type Solenoid Operated Proportional Throttle Valve

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

PCP Series Piston Pumps - Industrial

Transcription:

Hydraulic power units ower units 7

HILM ower Units and Valve ackages ir/oil power units for die lifters manually operated die lifter pumps on request 7.0100.US 7.0150.US ir/oil power units for die clamp systems, and use with remote valve packages 7.0200.US 7.0300.US ir/hydraulic power units activated by manual or solenoid valves ir/oil power units with solenoid valves/pressure switches for die clamp and lift systems 7.0350.US 7.0400.US ir/oil power units for die clamp and lift systems 7.0500.US Electric/Hydraulic power unit for die clamp and lift systems 7.0600.US 7.0700.US Valve packages solenoid operated manually operated 7.0800.US 7.0850.US dditional power units modular design accessories and service 7.1800 7.2500 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 168

ir/oil power unit for use with rollblocks max. operating pressure 1,740 psi pplications: he HCR--23X01 is an air-driven pump package. It is designed for intermittent use and the actuation of die lifters with operating pressure of 550 to 1,740 psi (40 to 120 bar). Description: he pump is actuated by the manual air toggle or solenoid operated valve located at the base of the pump. It has a 40 cu. inch reservoir, with 20 cu. inch usable capacity. he out-put pressure (20:1) is controlled by the adjustable air regulator. safety circuit relief valve reduces possible pressure intensification caused by overloading the rollblocks. return line check valve keeps balls or rollers that are not under the die up during stamping. Note: Minimum inlet air pressure is 60 psi, and 95 psi is required to achieve 1740 psi pressure. ir supplied to pump must be clean, dry and non-lubricated. ir filter is included. art no. Valve ressure switch HCR--23201 manual toggle no HCR--23201-S manual toggle yes HCR--23501 110 VC no HCR--23501-S 110 VC yes HCR--23601 24 VDC no HCR--23601-S 24 VDC yes hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0100.US 169

ir/oil power unit for use with rollblocks max. operating pressure 5,800 psi pplication: his pump series is for use with high pressure die lifters (page 8.1834). Description: he die lifter pumps include a circuit relief valve which eliminates pressure intensification by overloaded die lifters. he clamp system pumps include pressure switches to monitor clamping circuits for machine safety. dvantages: compact design horizontal mounting Operating pressure psi 3,000-5,800 Inlet air pressure psi 60 Flow rate (cu in/min) see graph Usuable fluid capacity (cu in) 125 Connecting threads Oil ports G 1/4 S ir inlet 1/4 N Weight (lbs) 14 art No. HCR--41201 HCR--41501 pplication High pressure die lifters High pressure die lifters Directional Valve 1 manual, 3 pos., 4 way 1 110 VC solenoid 2 pos., 3 way Circuit Relief Valve ressure Switch 1 None 1 None 7.0150.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 170

Compact air/oil power unit for die clamping of small systems pplication: hese air powered units are suitable for small, low volume die clamp and lift systems. Description: his family of compact, single stage pumps are configured with standard modular components. he proper combination of and electrical controls provide power source to suit small single circuit systems. he unit is supplied with a compact air filter and regulator. dvantages: compact design oil level sight gauges pressure switch for press safety circuit vertical mounting Specials available include: larger reservoirs horizontal mounting echnical data Max. clamping pressure psi 5,800 Flow rate (average) (cu in/min) 60 Reservoir capacity (usable) (cu in) 60 (30) air/oil ratio 3.2 75 to 1 ir requirement (minimum) psi 80 Oil ports SE #4 ir inlet N 3/8 Solenoid data Voltage HCR--21510-60 HCR--21610-60 VC VDC 110 24 Duty cycle continuous ressure Switch djustable pressure settings psi 750 to 5,800 verage pressure differential at 1,450 psi psi 350 ± 73 at 7,250 psi psi 750 ± 116 Switch NO/NC VC 5 at 250 Contact rating VDC 3 at 30 art No. Valve ressure Switch HCR--21100-60 use w/remote valves none none HCR--21210-60 Manual, 3 pos., 1 1 4-way valve HCR--21510-60 110 VC Solenoid 1 1 2 pos., 4-way N/O valve HCR--21610-60 24 VDC Solenoid 2 pos., 4-way N/O valve 1 1 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0200.US 171

ir/oil power unit for die clamping pplication: hese air powered units have been developed for the small to mid-sized die clamp and lifter systems. Description: his family of compact, two stage pumps are assembled from standard modular components. he proper combination of and electrical controls provide a power source to suit most needs. ower Unit is supplied with air filter/regulator. dvantages: compact design oil level sight glasses horizontal or vertical mounting pressure switch for press safety circuit (see chart at right) Specials available include: larger reservoirs fluid level switch horizontal mounting echnical data Max. clamping pressure psi 5,800 Flow rate (cu in/min) 150 Reservoir usable capacity (cu in) 40 Suction filter HCR-U.HF101 micron 25 air/oil ratio, stage 1 20 to 1 air/oil ratio, stage 2 100 to 1 ir requirement psi 60 Oil ports SE #4 ir inlet N 3/8 Solenoid data Voltage HCR--11510 HCR--11610 VC VDC 110 24 Current ohms 0.2 Duty cycle continuous ressure Switch djustable pressure settings psi 750 to 5,800 verage pressure differential at 1,450 psi psi 350 ± 73 at 7,250 psi psi 750 ± 116 Switch NO/NC VC 5 at 250 Contact rating VDC 3 at 30 art No. Valve ressure Switch HCR--11100 use w/remote valves none none HCR--11210 Manual, 3 pos., 1 1 4-way valve HCR--11510 110 VC Solenoid 1 1 2 pos., 4-way valve HCR--11610 24 VDC Solenoid 2 pos., 4-way valve 1 1 7.0300.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 1 172

ir/oil power unit for use with die clamping HCR--11100 ower Unit with blanking plate to use with remote valve package. HCR--11210 ower Unit with a 3 position valve and pressure switch. HCR--11510 ower Unit with a 2 position/4-way 110 VC solenoid valve and pressure switch. hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0300.US 173 2

ir/ power unit ready for installation pplication: his compact air/ power unit is a complete package ready for installation. With two pumps available, it is particularly well suited for low volume and medium volume die clamping systems. Description: he clamping circuits are activated by using either hand operated manual valves or convenient solenoid operated valves. separate valve with pressure switch is provided for each clamp circuit. he pressure switch with each clamp valve provides the user with a signal indicating that a safe clamp pressure is achieved. he power unit is available with two pump sizes and with various configurations of control valves, including die lifter control valves in various pressure ranges. he pump is a simple air/ oil intensifier, which operates intermittently with automatic pressure control, i.e. oil pressure is a ratio of the regulated air inlet pressure. he power unit may be connected to any compressed air system and includes an air pressure reducing valve to regulate incoming air pressure, air pressure gauge, oil level sight glass, valves as specified, air muffler, and convenient valve on pump assembly suitable for vertical mounting surfaces. dvantages: modular unit ready for installation compact, light weight design zero leak, directional valves maintain clamping pressure in case of power failure sight glass for oil level control HCR--1-1110-4 echnical data Series 1 pump Series 2 pump Max. operating pressure 5,800 psi 5,800 psi verage pump displacement 150 in³/min 60 in³/min Reservoir usable capacity 40 in³ 30 in³ Reservoir total capacity 80 in³ 60 in³ Mounting hole pattern (X,Y) (7 in, 7 in) (5 in, 5.5 in) ir/oil ratio stage 1 20:1 75:1 ir/oil ratio stage 2 100:1 N/ ir requirement for max hyd pressure 65 psi 85 psi Hydraulic port(s) G1/4 S G1/4 S Compressed air port 3/8" N 3/8" N Electrical solenoid data C type DC type Voltage 120 VC 24 VDC Current 0.20 mps 0.38 mps Duty cycle 100% 100% ressure switch data djustable pressure settings 750-5,800 psi vg. pressure differential at 1,450 psi 350 ± 73 psi vg. pressure differential at 7,250 psi 750 ± 116 psi Switch NO/NC 5 at 250 VC Contact rating 3 at 30 VDC 7.0350.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 1 174

Ordering example, pump displacement, control configuration Ordering example Ordering Example HCR--1- H C R - - 1-1 1 1 0-2 ump ype Control Configuration Double-acting clamp circuit Single-acting clamp circuit Valve type/ ressure switch Low pressure die lifter circuit High pressure die lifter circuit ump Displacement 1 Hydraulic Unit, 150cu. in./min. @ 5800 SI 2 Hydraulic Unit, 60cu. in./min. @ 5800 SI Control Configuration Die Lifter Double cting Clamp Circuit hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0350.US 175 2 Single cting Clamp Circuit Low ressure 550-5500 SI High ressure 5800 SI 0100 0 1 0 0 1 single-acting clamp circuit pplication, Special Features 0101 0 1 0 1 1 single-acting clamp circuit and 1 high pressure die lift circuit 0110 0 1 1 0 1 single-acting clamp circuit and 1 low pressure die lift circuit 1000 1 0 0 0 1 double-acting clamp circuit 1001 1 0 0 1 1 double-acting clamp circuit and 1 high pressure die lift circuit 1010 1 0 1 0 1 double-acting clamp circuit and 1 low pressure die lift circuit 1100 1 1 0 0 1 double-acting clamp circuit and 1 single-acting clamp circuit 1101 1 1 0 1 1110 1 1 1 0 1 double-acting clamp circuit, 1 single-acting clamp circuit and 1 high pressure die lift circuit 1 double-acting clamp circuit, 1 single-acting clamp circuit and 1 low pressure die lift circuit 2000 2 0 0 0 2 double-acting clamp circuits 2001 2 0 0 1 2 double-acting clamp circuits and 1 high pressure die lift circuit 2010 2 0 1 0 2 double-acting clamp circuits and 1 low pressure die lift circuit Valve ype/ressure Switch Valve Voltage 110 VC 24 VDC Manual ress Enable ressure Switch(es) 0 1 2 3 4 5 6 Directional seat valves with HWE hole patterns, mounting dimensions as per HWE spec sheet D7300, size 1 Machine Safety ressure switch connected to the press enable circuit. Switch setting is 15% (min.) below clamping pressure. ress operation is allowed only when set pressure is reached. If clamp pressure drops below setting, the press is automatically stopped.

Hydraulic schematics, control configuration 7.0350.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 3 176

ir/oil power unit modular power unit with solenoid valves HCR--S521 shown pplication: he modular pump valve packages have been developed for controlling small to mid-size die clamp and lift systems. Description: he pump valve packages are supplied complete with required pump, valves, pressure switches and electrical connections mounted on a common plate for fast, convenient installation on press frames. n electrical terminal box allows easy connection to clamp and die lift controls and press interlocks. Safety pressure switch in each clamp circuit line provides a signal to the press enable circuit in the event of a pressure loss. he pump valve packages are assembled from standard components. For more information on the pump unit, see catalog page 7.0300. For more information on the valve package, see catalog page 7.0402. ir Requirement Max. Hydraulic Operating ressure Hydraulic orts Solenoid Voltage 60 psi @ 30 cfm 5,800 psi 7/16-20 (#4 SE) 110 VC Die Lifter Circuit art No. Clamp Circuits Reduced ressure 400-2, 175-SI System ressure 5,800 SI max HCR--S511 1 1 HCR--S511-H 1 1 HCR--S520 2 HCR--S521 2 1 HCR--S521-H 2 1 * For 24 VDC solenoid voltage, use HCR--S6XX. dvantages: modular unit simplified installation press enable pressure switches Other solenoid control voltages available upon request. Special power units available upon request. hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0400.US 177

ir/oil power unit modular power unit with solenoid valves pplication: hese air powered units have been developed for the mid-sized to large die clamp and lift systems. Description: he power units with safety circuits have been developed in view of the special requirements of die clamping on presses. he pumps are supplied complete with required valves, pressure switches and electrical controls ready for connections to the press. he pumps are assembled from standard modular components. his provides a selection of the proper combination of and electrical controls for most die clamping applications. he die lifter circuit provides an adjustable pressure reducer with circuit relief and a return line check valve. his keeps the die lifters that are not under the die up during stamping. ower unit comes complete in a protective frame with a remote pendant with key switches. Special power units available on request. Separate clamp circuit pressure switches on request. dvantages: fast clamp/unclamp times pressure filter return line filter temp/level switch system pressure switch echnical data Hydraulic Max. clamping pressure psi 5,800 Flow rate (average) (cu in/min) 220 Reservoir capacity gal 5 Reservoir usable capacity (cu/in) 847 ressure filter micron 25 Suction strainer micron 175 Return line filter micron 10 air/oil ratio, stage 1 20:1 air/oil ratio, stage 2 75:1 ir requirement 80 psi, 1/2 N inlet Clamp output ports #6 SE Die lifter output port #4 SE Solenoid data Voltage VC 110 Current mps 0.2 Duty cycle continuous ressure Switch data djustable pressure settings psi 750 to 5,800 verage pressure differential at 1,450 psi psi 350 ± 73 at 7,250 psi psi 750 ± 116 Switch NO/NC single pole Contact rating VC VDC 5 at 250 3 at 30 art No. Die Lifter Circuit Clamp endant Reduced ressure System ressure Circuits Key Switches 400-2, 175-SI 5,800 SI max HCR--51510 1 1 HCR--51511 1 1 2 HCR--51511-H 1 1 2 HCR--51520 2 2 HCR--51521 2 1 3 HCR--51521-H 2 1 3 * dd -1 to end of part number to order without pendant station. * 24 VDC solenoid voltage upon request. 7.0500.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 1 178

ir/oil power unit modular power unit with solenoid valves hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0500.US 179 2

Electric power unit compact pplication: Electrically driven high-pressure unit for operating small and midsize clamping systems. Suitable for both single-acting and double-acting cylinders. Unit operates intermittently with automatic pressure controls. he required operating pressure is preset on a pressure switch that controls the motor. When the set pressure is reached, the motor is automatically switched off. If the pressure drops 10% below the set value, the pressure switch starts the motor again. Description: Complete with motor, pump, oil tank, manifold block, pressure gauge, pressure switch, valves and electrical system. he radial piston pump is bi-directional and fixed displacement. Zero leakage poppet type directional valves. Electrical system is to US standards. he control voltage (24VDC or 120VC) is supplied by the customer. he oil level and temperature sensor is standard. Optional equipment includes remote control pendant and machine safety pressure switches. Die lifter circuit: he low pressure die lifter circuit provides an adjustable reducer with a circuit relief valve. he high pressure die lifter circuit operates at full system pressure. oth include a circuit relief valve which reduces possible pressure intensification caused by overloading the die lifters. dvantages: modular unit ready for installation compact, light weight design zero leak, directional valves maintain clamping pressure in case of power failure highly reliable radial piston pump ensures long service life fluid immersed, direct drive motor, and finned aluminum housing provides optimum efficiency zero leak fittings and valves sight glass for oil level control oil temperature/level switch 230 VC 3Ø 460 VC 3Ø Max. pressure 400 bar (5800 psi) 1 ower supply frequency 60 Hz Control voltage 120 VC or 24 VDC 2 Flow rate 1.8 L/min (110 cu.in./min) 1 Usable fluid capacity 1.85 L (112 cu.in.) 1 Reservoir capacity 3.9 L (238 cu.in.) 1 ower @ max. pressure 0.75 kw (1 hp) 0.9 kw (1.2 hp) Motor amperage 3.9 amps 2.1 amps Noise level @ 1 meter (3.3 feet) 65 d Max. duty cycle 25-40 % pprox. weight w/ one valve & oil 25 kg / 55 lbs 1 Different flow rates, max. pressures and tank sizes available upon request. 2 Control voltage supplied by customer. 7.0600.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 1 180

Electric power unit compact Ordering example HCR-E-6-2 0 0 1-1 1 0 ump type Control Configuration Double-acting clamp Single-acting clamp Low pressure die lifter High pressure die lifter ump ype 6 Hydraulic unit, 110 cu. in./min. @ 5800 SI Control Configuration Double acting clamp circuit Single acting clamp circuit Low ressure 550-5500 SI Die Lifter High ressure 5800 SI pplication, Special features 0100 0 1 0 0 1 single-acting clamp circuit 0101 0 1 0 1 1 single acting clamp circuit and high pressure die lift circuit 0110 0 1 1 0 1 single-acting clamp circuit and low pressure die lift circuit 1000 1 0 0 0 1 double-acting clamp circuit 1001 1 0 0 1 1 double-acting clamp circuit and high pressure die lift circuit 1010 1 0 1 0 1 double-acting clamp circuit and low pressure die lift circuit 1100 1 1 0 0 1 double-acting clamp circuit and 1 single-acting clamp circuit 1101 1 1 0 1 1 double-acting clamp circuit, 1 single-acting clamp circuit and 1 high pres. die lift circuit 1110 1 1 1 0 1 double-acting clamp circuit, 1 single-acting clamp circuit and 1 low pres. die lift circuit 2000 2 0 0 0 2 double-acting clamp circuits 2001 2 0 0 1 2 double-acting clamp circuits and 1high pressure die lift circuit 2010 2 0 1 0 2 double-acting clamp circuits and 1 low pressure die lift circuit Valve ackage/monitoring System Valve Voltage ress Enable 110 VC 24 VDC ressure Switch 0 1 2 3 4 Electric Control 0 Without Electric With erminal ox 1 With Electric For Remote endant 2 Without Electric With erminal ox 3 With Electric For Remote endant Remote endant 0 Without Remote endant emp/level Switch 460 Volts 3 hase 60 Hz 230 Volts 3 hase 60 Hz ressure relief valve and pressure switch: Operating pressure infinitely adjustable from 725 to 5,800 psi. Directional seat valves: With HWE hole patterns, mounting dimensions as per HWE spec sheet D7300, size 1. Machine Safety: ressure switch connected to the machine control system. Switch setting is 15% (min.) below clamping pressure. Machine operation is allowed only when set pressure is reached. If pressure drops below setting, machine is automatically stopped. Oil level and temperature switch: oth oil level and temperature switch are provided to automatically switch off the pump motor if there is lack of oil or the temperature exceeds 140 F. With electric, for remote pendant or control panel: Hydraulic unit can be supplied ready to install with the necessary circuit breakers, motor starter, overload protection, etc., already wired to an electrical enclosure for use with remote pendant, or control panel. ower for valve control is supplied by customer. Without electric, with terminal box: Optionally, the unit can be supplied with just the motor, valves, and pressure switch wired to a terminal strip. his is often desired for new machine controls. hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0600.US 181 2 Without remote pendant Electric control Valve package/monitoring system

Hydraulic schematics, control configuration 7.0600.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 3 182

Electrical power unit large capacity dvantages: modular unit ready for installation compact, light weight design directional valves open in clamping position, maintains clamping pressure in case of a power failure remote pendants wired direct sight glass for oil level control pump frame included with most models pplication: Electrically driven high-pressure unit for operating small and midsize clamping systems. Suitable for both single-acting and double-acting cylinders. Unit operates intermittently with automatic pressure control. he required operating pressure is preset on a pressure switch that controls the motor. When the set pressure is reached, the motor is automatically switched off. If the pressure drops 10% below the set value, the pressure switch starts the motor again. dditional pressure switches can be supplied for machine safety. hese switches are to be interfaced to stop the machine if clamping pressure drops more than 15%. Description: Complete with motor, pump, oil tank, manifold block, pressure gauge, pressure switch, valves and electrical system. he radial piston pump is bi-directional and fixed displacement. Zero leakage poppet type directional valves. Electrical system is to US standards. he oil level and temperature sensor is standard. Optional equipment includes remote control pendant and machine safety pressure switches. ump frame is standard on three valve power units. Die lifter circuit: he low pressure die lifter circuit provides an adjustable reducer with a circuit relief valve. he high pressure style die lifter circuit operates at full system pressure. It includes a circuit relief valve which reduces possible pressure intensification caused by overloading the die lifters. Important notes: Hydraulic power units should be positioned off the press area away from operator s handling space. Make sure: that oil ports, pressure switches, oil drain plug and oil filler cap are easily accessible. that pressure gauge, oil sight glasses and signal lamps are visible. Operating conditions, tolerances, and other data, see data sheets 1.1000-12. Electrical system: Main connection (L1, L2, L3, GND) without connector plug, electric motor 1.5 Hp, 1740 rpm, 230/460 volts, 3 phase, 60 cycles, control voltaage 24 VDC, or 110 VC. Directional valves: oppet valves zero leakage, max. operating pressure 5,800 psi flow rate 106 cu in/min. Oil connection: 1/4 JIC male fitting/g 1/4 port Hydraulic fluid: See data sheets 1.1000-12. ower supply hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 230/460 volts 3 phase 60 hz Flow rate (cu in/min) 106 Usable fluid capacity (cu in) 400 Reservoir capacity (cu in) 690 Horsepower 1.5 mperage 4.6/2.3 Noise level @ 3 ft. (d) 67 Max. uninterrupted running time (sec) 15-120 Max. % of cycle pump should operate 25-40% 7.0700.US 183 1

Ordering example, pump displacement, control configuration ump displacement Control Configuration Valve Voltage ress Enable ressure emp/level 110 VC 24 VDC Switch Switch 0 1 2 3 4 0 Without Remote endant 1 With Remote endant 7.0700.US 7 Hydraulic unit, 106 cu. in./min. @ 5800 SI Die Lifter Double Single Low acting acting ressure High clamp clamp 550-1100 ressure circuit circuit SI 5800 SI pplication, Special features 0100 0 1 0 0 1 single-acting clamp circuit 0101 0 1 0 1 1 single-acting clamp circuit and high pressure die lift circuit 0110 0 1 1 0 1 single-acting clamp circuit and low pressure die lift circuit 1000 1 0 0 0 1 double-acting clamp circuit 1001 1 0 0 1 1 double-acting clamp circuit and high pressure die lift circuit 1010 1 0 1 0 1 double-acting clamp circuit and low pressure die lift circuit 1100 1 1 0 0 1 double-acting clamp circuit and 1 single-acting clamp circuit 1101 1 1 0 1 1 double-acting clamp circuit, 1 single-acting clamp circuit and 1 high pres. die lift circuit 1110 1 1 1 0 1 double-acting clamp circuit and low pressure die lift circuit 2000 2 0 0 0 2 double-acting clamp circuits 2001 2 0 0 1 2 double-acting clamp circuits and 1 high pressure die lift circuit 2010 2 0 1 0 2 double-acting clamp circuits and 1 low pressure die lift circuit Valve ackage/monitoring system Electric control 0 Without Electric With erminal ox 460 Volts 3 hase 1 With Electric For Remote endant 60 Hz 2 Without Electric With erminal ox 230 Volts 3 hase 3 With Electric For Remote endant 60 Hz Remote pendant endant includes key operated switches. ressure relief valve and pressure switch: Operating pressure infinitely adjustable from 725 to 5,800 psi. Directional seat valves: With HWE hole patterns, mounting dimensions as per HWE spec sheet D7300, size 1. Machine Safety: ressure switch connected to the machine control system. Switch setting is 15% (min.) below clamping pressure. Machine operation is allowed only when set pressure is reached. If pressure drops below setting, machine is automatically stopped. Oil level and temperature switch: oth oil level and temperature switch are provided to automatically switch off the pump motor if there is lack of oil or the temperature exceeds 140 F. With electric, for remote pendant or control panel: Hydraulic unit can be supplied ready to install with the necessary circuit breakers, motor starter, overload protection, etc., already wired to an electrical enclosure for use with remote pendant, or control panel. ower for valve control is supplied by customer. Without electric, with terminal box: Optionally, the unit can be supplied with just the motor, valves, and pressure switch wired to a terminal strip. his is often desired for new machine controls. hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 2 184

Hydraulic schematics, control configuration hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0700.US 185 3

Valve packages manual and solenoid operated pplication: hese modular valve packages provide safe solenoid control of the fluid to the die clamps and filters. Description: he clamping pressure, as supplied from a separate pump unit and controlled by one of these integrated valve packages, can actuate single or double-acting clamp circuits in the bed and ram. Safety pressure switch in each clamp line provides a signal to the press enable circuit in the event of a pressure loss. he low pressure die lifter circuit provides an adjustable pressure reducer with circuit relief valve. he high pressure die lifter circuit, operates at the clamp system pressure and includes a circuit relief valve. his safety valve prevents the rollblocks from being overloaded. Specials available on request. echnical data Hydraulic Max. clamping pressure psi 7,250 Low pressure die lifter psi 450-4,600 Max. flow rate (cu in/min) 490 orts S G 1/4 Electrical data C YE DC YE Voltage 110 VC 24 VDC Inrush current.2.83 Holding current.2.83 Duty cycle 104 F (40 C) 100% 100% ressure switch data djustable pressure setting psi 750 to 5,800 verage pressure differential at 1,450 psi psi 350 ± 73 at 7,250 psi psi 750 ± 116 Switch NO/NC single pole Contract rating VC 5 at 250 VDC 3 at 30 dapter fittings available CLR-816-F CLR-807-F CLR-806-F CLR-802-F G 1/4 to 1/4 JIC G 1/4 to 5/16 JIC G 1/4 to 1/4 compression G 1/4 to 1/4 compression dvantages: solenoid valves can be operated via.l.c. system or manual switch zero-leakage poppet design with built-in check valve very compact suitable for new or existing press room equipment 7.0800.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 1 186

Valve package configuration Ordering example HCR V S2001-1 Valve package, solenoid (S) manual (M) Double-acting clamp circuit(s) Single-acting clamp circuit(s) Low pressure die lifter circuit(s) High pressure die lifter circuit(s) Valve ressure switch Control Configuration Die Lifter Low (L) Double Single ressure High pprox. pprox. clamp clamp 550-1100 ressure weight length circuit circuit psi 5800 psi pplication, Description lbs (inches) 0100 0 1 0 0 1 single-acting clamp circuit 8 5.75 0101 0 1 0 1 1 single-acting clamp circuit and high pressure die lift circuit 18 9.44 0110 0 1 1 0 1 single-acting clamp circuit and low pressure die lift circuit 26 11.69 1000 1 0 0 0 1 double-acting clamp circuit 11 5.75 1001 1 0 0 1 1 double-acting clamp circuit and high pressure die lift circuit 21 9.44 1010 1 0 1 0 1 double-acting clamp circuit and low pressure die lift circuit 29 11.69 1100 1 1 0 0 1 double-acting clamp circuit and 1 single-acting clamp circuit 25 9.12 1101 1 1 0 1 1 double-acting, 1 single-acting clamp circuit and 1 high pressure die lift circuit 35 12.81 1110 1 1 1 0 1 double-acting, 1 single-acting clamp circuit and 1 low pressure die lift circuit 43 15.06 2000 2 0 0 0 2 double-acting clamp circuits 19 9.12 2001 2 0 0 1 2 double-acting clamp circuits and 1 high pressure die lift circuit 29 12.81 2010 2 0 1 0 2 double-acting clamp circuits and 1 low pressure die lift circuit 47 15.06 Valve ressure Switch Valve Voltage ress Enable Manual ressure 110 VC 24 VDC Valve Switch(s) 0 1 2 3 4 5 6 Directional seat valves: - with HWE hole patterns, mounting dimensions as per HWE spec sheet D7300, size 1 Machine Safety: ressure switch connected to the press enable circuit. Switch setting is 15% (min.) below clamping pressure. ress operation is allowed only when set pressure is reached. If pressure drops below setting the press is automatically stopped. hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0800.US 187 2

Hydraulic schematics 7.0800.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 3 188

Valve packages manually operated pplication: hese manually operated valve packages provide a safe, convenient means of controlling the fluid to die clamp and lifters for any press applications in a simple integrated unit. Description: he clamping pressure, as supplied from a separate pump unit, can actuate single- or double-acting clamps in the bed and ram safety. ressure switches in the clamp line(s) (C1, C2) provide a signal to the press circuit if a valve is not activated or in the event of a pressure loss. he reduced pressure die lifter circuit provides an adjustable reducer with circuit relief and a return line check valve to keep rollers with individual pistons not under the die, up during stamping. he H-style die lifter circuit operates at full system pressure. It includes a circuit relief valve which reduces possible intensification caused by overloading the die lifters. Can be mounted in any position. dvantages: economical suitable for new or retrofit press enable pressure switches echnical data Hydraulic Max. clamping pressure psi 5,800 Die lifter pressure See chart Max. flow rate (cu in/min) 693 Oil ports SE 7/16-20 UNC ressure switch data djustable pressure setting psi 750 to 5,800 verage pressure differential at 1,450 psi psi 350 ± 73 at 7,250 psi psi 750 ± 116 Switch NO/NC single pole Contract rating VC 5 at 250 Contact VDC 3 at 30 art no. Die lifter circuit Clamp Weight Reduced pressure System pressure circuits (lbs.) 400-2,175-SI 5,800 SI max HCR-V-M01 1 7.0 HCR-V-M01-H 1 6.5 HCR-V-M10 1 8.5 HCR-V- M11 1 1 15.5 HCR-V-M11-H 1 1 15.0 HCR-V-M20 2 10.5 HCR-V-M21 2 17.5 HCR-V-M21-H 2 1 17.0 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.0850.US 189 1

Valve packages manually operated 7.0850.US hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 2 190

ower units in modular design pplication: For the operation of clamping fixtures and other handling and clamping systems on machine tools. Description: he power units of this series consist of individual modules that are selected depending on the application and are assembled on the basis of a type code to a power unit ready for use. Valve block Control circuit _V1 XX X XXX SX_..._V4 oppet/spool valves, function triggering, additional functions for single and double-acting cylinders continuously adjustable operating pressure expandable to up to 8 pressure circuits constant flow rate wide range of valves wide range of functions energy-saving mode S3 (intermittent mode) or S6 (unpressurized cycle) supplied ready for connection Equipment - Standard Modules: Characteristics ower unit (reservoir, pump, motor) Connecting block basic functions Valve block with up to 4 control circuits Electronics Electronics _E X Electric control, terminal box connecting block with pressure relief valve pressure filter 10 µm oil level gauge stick thermometer design without piping Equipment - Options electronic system pressure switch (with teach-in function*) system pressure switch or machine tool interlock mechanical or electronic electrical oil level control electrical temperature control return filter electrical filter control electric control terminal box foot switch or manual switch key switch erformance data Connecting block asic functions _ XXX_ System pressure switch, unpressurized cycle, intermittent mode, filter control, oil control p max. [bar] Q [l/min] Reservoir [l] 120 12 27 40 63 160 8.8 27 40 63 160 12 40 63 200 1.5 11 27 40 63 200 3.3 11 27 40 63 200 4.5 11 27 40 63 200 6.2 27 40 63 200 8.8 40 63 350 3.6 27 40 63 350 5.3 40 63 400 2.5 11 27 40 63 450 4.2 40 63 500 0.9 11 27 40 63 500 1.5 11 27 40 63 500 2.6 27 40 63 500 3.7 40 63 500 0.7 / 5.2 11 27 40 63 500 0.7 / 8.8 11 Further pump variants and equipments are available on request. * special system software for simplified system pressure adjustment asic power unit M XX Motor rating 0.75 3.0 kw Reservoir sizes 11, 27, 40, 63 liters 191 1 Hilma-Römheld GmbH Carr Lane Roemheld Mfg Co. Schützenstraße 74Drive, 57271 Hilchenbach, Germany 927 Horan Fenton, MO 63026 hone +49800-827-2526 (0) 2733 / 281-0Fax Fax +49 (0) 2733 /www.hilma-usa.com hone 636-386-8034 7.1800

ower units in modular design type code structure and determination ype code: MXX_XXX_V1-XX X XXX S X _V2-XX X XXX S X _V3-XX X XXX S X _V4-XX X XXX S X _EX asic power unit asic functions Electronics Control circuit 1 Control circuit 2 Control circuit 3 Control circuit 4 Switch variant Switch variant Switch variant Switch variant Modular design: y the use of pre-assembled modules, module power units can be flexibly implemented in the short term and in a cost-effective way. he modular design and numerous design options allow a flexible adaptation to the respective application. Module power units are particularly suitable as a base to build complex controls. linkable basic block offers the user the possibility to expand the power unit with different function and control elements for the specific application. Determination of the type code: type code that results from the used modules is available for the different module components and results in the final part number for the power unit. o select the correct arrangement, size and performance of the individual components, you will find all parameters and their type code on the following pages. Safety features: recisely defined clamping force by continuously adjustable operating pressure Electronic system pressure switch with digital pressure display (option) Repeatability ± 1 bar Renewed oil supply after a pressure drop of max. 10 % Machine tool interlock (option) at a pressure drop of max. 20 %, is automatically updated in case of pressure adjustment Oil level and temperature control (option) recise oil temperature display by stick thermometer ressure filter 10 µm in the connecting block Screen disks in the ports Control voltage 24 V DC ressure maintenance in case of power failure due to hermetically sealed poppet valves Overpressure protection of the individual pressure circuits (option) Important notes: hese power units are exclusively designed for the industrial use of pressure generators for fixtures. ll connected components must be leakage-free and designed for the maximum operating pressure of the power unit. he power unit generates very high pressures. he connected cylinders generate very high forces so that there is a permanent danger of crushing in the effective area of the piston rod. he manufacturer of the fixture or the machine is obliged to provide effective protection devices. Installation, start up and maintenance have to be made according to the operating manual by authorized experts. echnical data Designs Gear pump max. 200 bar iston pump max. 500 bar ump combination max. 80 / 500 bar ype of mounting foot mounting ort size G 1/4, G 3/8 and G 1/2 Direction of rotation (view from above onto the drive shaft) Gear pump clockwise rotation iston pump any ump combination counterclockwise rotation Mounting position upright Usable oil volume 50 % of reservoir volume Vol. efficiency η vol = 85 95 % * Other voltages/frequencies on request. Special approvals on request. Electrical characteristics - Motor Nominal voltage* ype Voltage type* Code class I 55 Max. relative cycle time 400 V up to 2.2 kw star connection 400 V from 3 kw delta connection squirrel cage rotor, 4-pole three-phase C voltage, 50 Hz depending on the operating pressure specifications for 100 % or 40 % ED see page 4 he calculation of the relative duty cycle is based on a cycle time of 10 min. With 40 % ED, e.g. the maximum load within the cycle should not exceed 4 min. During the remaining time, the motor can carry a load of up to 50 % of the nominal output and should run continuously. 7.1800 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 2 192

ower units in modular design circuit diagram for example power unit Hydraulic circuit diagram Example power unit 0 = Electronic system pressure switch with teach-in function ay attention to operating manual 9740-050! Z2 3610 098 Z1 F2 3887 102 Z1 3551 030 F2 3887 102 Z1 3551 030 Z2 3610 098 R R 2 1 2 W2 M2:G1/4 8000 438 V3 2363 326 NW 6 a 2952 029 2 1 2 W2 8000 438 V1 Y0 V3 2363 326 NW 6 a 2952 500 bar 029 1 V1 3887 107 3822 006 S1 3885 009 3820 005 W14 Y0 F1 S1-1 0-100 C 10µm Min. M1 0,75 KW S1-2 Q1 500 bar 63 C Z3 Z5 3830 051 1 3887 107 3822 006 S1 3820 005 W14 3885 009 F1 L Z4 3456 022 S1-1 Maximum 0-100 C 10µm Rohr Min. M1 Rohr Ø10x2,5 0,75 KW S1-2 Q1 ØG3/8" Ø8x2 :G:3/8 Minimum 63 C Z3 Z5 3830 051 V2 3885 004 L Rohr Z4 3456 022 Maximum ØG3/8" Ø10x1,5 3:G3/8 1 Rohr Rohr 80 bar Ø10x2,5 3811 036 R:G3/8 ØG3/8" Ø8x2 :G:3/8 Minimum V2 3885 004 FE1 ØG3/8" M 10 M 10 1 3811 036 M1 8000 430 8000 430 1:G3/8 1:G3/8 Rohr Ø10x1,5 3:G3/8 80 bar W3 W4 :G3/8 R:G1/2 NW 6 oundary of the power unit 8000 437 W3 W4 Z6 9740 050 :G3/8 0-600bar R:G1/2 NW 6 0 8888 8000 437 M2:G1/4 Z6 9740 050 0-600bar 0 8888 M1:G1/4 M1:G1/4 1 2952 065 2952 065 R:G3/8 2450 261 1:G3/8 1:G3/8 1:G3/8 1:G3/8 Z7 2450 9740 261 049 0-600bar 2 8888 Z7 9740 049 0-600bar 2 8888 V4 2953 850 NW 6 9846 000 0-600bar 100 bar M:G1/4 V4 Z17 NW 6 9846 000 0-600bar V5 2957 404 NW 6 Z17 M:G1/4 V5 2957 404 NW V6 6 2363 320 NW 6 M:G1/8 Y1 a V6 2363 320 NW 6 M:G1/8 Y1 a M:G1/4 M:G1/4 V1-054110 SX V1-054110 SX 100 bar M:G1/4 M:G1/4 2953 850 M:G1/8 b Y2 M:G1/8 b Y2 Valve voltage 24 V DC, 30 W / 2.1 / 2.1 / 2.1 / 2.1 Z1 Reservoir volume : 27 Liter Hydraulic oil : HL 32 Norm : ISO 6743/4 FE1 Filter element ype : 10 µm art no. : 3887107 M1 n = 1400 U/min = 0,75 kw U = 400 V f = 50 Hz 1 p = 500 / 80 bar Q = 0,7 / 5,2 l/min n = 1400 U/min Hydraulic circuit diagram Example power unit oundary of the power unit W5 NW 6 W6 NW 6 W7 NW 6 1.8 / 1.8 / W5 NW 6 2450 261 2:G3/8 2:G3/8 W6 NW 6 2450 261 3:G3/8 3:G3/8 W7 NW 6 2450 261 4:G3/8 4:3/8 1.8 / 1.8 / 2:G3/8 2:G3/8 2450 Z8 261 9740 049 0-600bar in1: 24V 3 8888 in2: S2 4-20 m 0-600 bar in3: Z8 0V 9740 049 0-600bar in4: S1 (off) in1: 24V 3 8888 in2: S2 4-20 m 0-600 V7 bar 2957 404 in3: 0VNW 6 in4: S1 (off) V7 2957 404 NW 6 M:G1/4 V8 2363 320 M:G1/8 NW 6 Y3 a V8 2363 320 NW 6 M:G1/8 M:G1/4 M:G1/4 M:G1/4 M:G1/8 M:G1/8 b Y4 Valve voltage 24 V DC, 30 W 3:G3/8 3:G3/8 2450 Z9 9740 261 049 0-600bar in1: 24V 4 8888 in2: S2 4-20 m 0-600 bar in3: 0V Z9 9740 049 0-600bar in4: S1 (off) in1: 24V 4 8888 in2: S2 4-20 m -?V 2363 325 0-600 bar NW 6 M:G1/8 M:G1/8 in3: 0V in4: S1 (off) Y5 a b Y6 -?V 2363 325 NW 6 M:G1/8 M:G1/8 Valve voltage 24 V DC / 30 W Y5 a b Y6 M:G1/4 M:G1/4 M:G1/4 M:G1/4 4:G3/8 Z10 2450 9740 261 049 0-600bar in1: 24V 5 8888 in2: S2 4-20 m 0-600 bar in3: 0V Z10 9740 049 0-600bar in4: S1 (off) in1: 24V 5 8888 in2: S2 4-20 m V10 0-600 bar 2363 324 in3: NW 6 0V in4: S1 (off) Y7 a V10 2363 324 NW 6 Y7 a M:G1/4 M:G1/4 4:3/8 M:G1/4 M:G1/4 Valve voltage 24 V DC / 30 W Y3 a b V2-054100SX Y4 V3-074000SX V4-014000SX ** see previous page Electrical characteristics - Motor V2-054100SX V3-074000SX V4-014000SX 193 hone +49 (0) 2733 / 281-0 Fax +49 (0) 2733 / 3 hone 800-827-2526 Fax 636-386-8034 www.hilma-usa.com 7.1800

ower units in modular design type code for power unit size MXX ype code: MXX_XXX_V1-XX X XXX SX_V2-XX X XXX SX_V3-XX X XXX SX_V4-XX X XXX SX_EX asic power unit: he basic selection takes place based on pressure p and flow rate Q. he size of the reservoir depends on the application conditions (e. g. environmental temperature, cycle time and function). * Note In case of the two-stage pump (RZ) the gear pump (large flow rate) is switched to unpressurized cycles by the integrated idling control valve as soon as a pressure of 80 bar is exceeded. Up to 80 bar, both flow rates will add up. 4 reservoir sizes: 11 l, 27 l, 40 l, 63 l 5 motor sizes: 0.75 kw, 1.1 kw, 1.5 kw, 2.2 kw, 3.0 kw 15 pump types: gear pumps, piston pumps, two-stage pumps* Example: Reservoir 11 l, max. 200 bar, gear pump 1.5 l/min, 0.75 kw = M 01 Reservoir 27 l, max. 350 bar, piston pump 3.6 l/min, 2.2 kw = M 19 Operating pressure [bar] Flow rate Motor rating Reservoir volume ump type M XX at 100 % ED at 40 % ED** Q [l / min] [kw] V [l] 425 500 0.9 0.75 11 iston pump 02 425 500 0.9 0.75 27 iston pump 09 425 500 0.9 0.75 40 iston pump 21 425 500 0.9 0.75 63 iston pump 38 375 500 1.5 1.1 11 iston pump 05 375 500 1.5 1.1 27 iston pump 12 375 500 1.5 1.1 40 iston pump 24 375 500 1.5 1.1 63 iston pump 41 430 500 2.6 2.2 27 iston pump 18 430 500 2.6 2.2 40 iston pump 30 430 500 2.6 2.2 63 iston pump 47 415 500 3.7 3.0 40 iston pump 34 415 500 3.7 3.0 63 iston pump 51 500 500 0.7 / 5.2* 0.75 11 wo-stage pump 03 500 500 0.7 / 8.8* 1.5 11 wo-stage pump 54 500 500 0.7 / 5.2* 0.75 27 wo-stage pump 10 500 500 0.7 / 5.2* 0.75 40 wo-stage pump 22 500 500 0.7 / 5.2* 0.75 63 wo-stage pump 39 365 450 4.2 3.0 40 iston pump 35 365 450 4.2 3.0 63 iston pump 52 310 400 2.5 1.5 11 iston pump 07 310 400 2.5 1.5 27 iston pump 14 310 400 2.5 1.5 40 iston pump 26 310 400 2.5 1.5 63 iston pump 43 310 350 3.6 2.2 27 iston pump 19 310 350 3.6 2.2 40 iston pump 31 310 350 3.6 2.2 63 iston pump 48 290 350 5.3 3.0 40 iston pump 36 290 350 5.3 3.0 63 iston pump 53 200 200 1.5 0.75 11 Gear pump 01 200 200 1.5 0.75 27 Gear pump 08 200 200 1.5 0.75 40 Gear pump 20 200 200 1.5 0.75 63 Gear pump 37 170 200 3.3 1.1 11 Gear pump 04 170 200 3.3 1.1 27 Gear pump 11 170 200 3.3 1.1 40 Gear pump 23 170 200 3.3 1.1 63 Gear pump 40 170 200 4.5 1.5 11 Gear pump 06 170 200 4.5 1.5 27 Gear pump 13 170 200 4.5 1.5 40 Gear pump 25 170 200 4.5 1.5 63 Gear pump 42 180 200 6.2 2.2 27 Gear pump 15 180 200 6.2 2.2 40 Gear pump 27 180 200 6.2 2.2 63 Gear pump 44 175 200 8.8 3.0 40 Gear pump 32 175 200 8.8 3.0 63 Gear pump 49 130 160 8.8 2.2 27 Gear pump 16 130 160 8.8 2.2 40 Gear pump 28 130 160 8.8 2.2 63 Gear pump 45 130 160 12 3.0 40 Gear pump 33 130 160 12 3.0 63 Gear pump 50 99 120 12 2.2 40 Gear pump 29 95 120 12 2.2 27 Gear pump 17 95 120 12 2.2 63 Gear pump 46 7.1800 Carr Lane Roemheld Mfg Co. Hilma-Römheld GmbH hone +49 (0) 2733 / 281-0 Fax +49 (0) 2733 / 194 hone 800-827-2526 Fax 636-386-8034 www.hilma-usa.com 4

ower units in modular design pump variants umping iston pumps ype Nominal pressure max. Flow rates* Direction of rotation* Speed range Feature radial piston pump 500 bar 3.6 / 5.3 l/min to 350 bar 2.5 l/min to 400 bar 4.2 l/min to 450 bar 0.9 / 1.5 / 2.6 / 3.7 l / min to 500 bar any continuous operation 100... 2000 1/min, short-time operation up to 2850 1/min high-pressure application, harsh operating conditions (e.g. punching / stamping) Gear pumps ype Nominal pressure max. Flow rates* Direction of rotation* Speed range Feature 2 opposite gears 200 bar 1.5 / 3.3 / 4.5 / 6.2 / 8.8 l / min to 200 bar 12 l/min to 160 bar clockwise rotation 700... 3000 1/min intermediate-pressure application, high flow rate wo-stage pump ype Nominal pressure max. Flow rate* up to approx. 80 bar from approx. 80 bar Direction of rotation* Speed range Feature ypical application radial piston pump and gear pump screwed together continuous drive shaft 500 bar total flow rate active (gear plus piston pump) only flow rate of piston pump active counterclockwise rotation 700... 2000 1/min, in short-time operation up to 2850 1/min high flow rate up to approx. 80 bar, high pressure up to 500 bar quickly move large volume consumers and clamp them with high pressure * at rated speed 1450 1/min ** direction of rotation (view from above onto the drive shaft) Different flow rates and other pumps are available on request. 195 5 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.1800

ower units in modular design type code for connecting block basic function XXX ype code: MXX_XXX_V1-XX X XXX SX_V2-XX X XXX SX_V3-XX X XXX SX_V4-XX X XXX SX_EX Standard equipment: Connecting block with pressure relief valve System check valve ressure filter 10 µm Oil level gauge Oil temperature gauge (stick thermometer) Filler and reservoir ventilation repared for additional features Connecting block basic functions: In addition to the standard equipment, additional features for the basic unit can be selected. each-in function: For teaching, the desired switching as well as reverse switching points are calculated and saved by pressing the Enter/Set key of the system. hus, the system pressure switch is ready for operation (run mode). he teach mode is activated by releasing the reset function. (Detailed technical data see page 10 of this series). _ X X X _ with pressure gauge, without system pressure switch, without vavle for unpressurized cycle 0 with electronic system pressure switch for intermittent cycle 1 with system pressure switch and valve for unpressurized cycle, p max = 500 bar 2 with system pressure switch and valve for unpressurized cycle, p max = 315 bar 3 with pressure gauge, without system pressure switch, with valve for unpressurized cycle, p max = 500 bar 4 with pressure gauge, without system pressure switch, with valve for unpressurized cycle, p max = 315 bar 5 with visual temperature and oil level display (standard) 0 with temperature and oil level control switch and visual temperature and oil level display 1 with pressure filter (standard) 0 pressure and return filter 1 pressure filter with filter control 2 pressure filter and return filter with filter control 3 Connecting block including pressure filter and pressure relief valve, port G 3/8, R port G 1/2 and system check valve (he retrofitting of individual features is possible at any time). System check valve (standard) Electronic system pressure switch with teach-in function (option) dditional options: Oil control (oil level / oil temperature) ressure relief valve (standard) ressure filter (standard) Return filter ressure filter control (option) Valve for unpressurised cycles (option) Return filter with filter control 7.1800 Carr Lane Roemheld Mfg Co. Hilma-Römheld GmbH hone +49 (0) 2733 / 281-0 Fax +49 (0) 2733 / 196 hone 800-827-2526 Fax 636-386-8034 www.hilma-usa.com 6

ower units in modular design technical data Monitoring functions - ower unit Oil control (oil temperature too high or oil level too low) Contact oil temperature break contact, opens at approx. 63 C Contact oil level make contact, closes when oil above the float ype of connection connector, 3-pin as per DIN 43650 in 1: common root in 2: level in 3: temperature Max. switching voltage 230 V C Max. switching current 1 Max. contact rating 10 V Medium temperature max. 85 C Code class I 65 For oil reservoir 11 litres art no. 3822-008 For oil reservoir 27 litres art no. 3822-006 For oil reservoir 40 litres art no. 3822-048 For oil reservoir 63 litres art no. 3822-005 Note: he oil control can be retrofitted. Several switching points for temperature and /or level on request. S1 1 2 3 max. 30 V DC max. 230 V C max. 10 V 1 2 3 E S1.1 3822-008 S1.2 ressure filter control For plug-type connector with illuminated display with snap switching element lunger material stainless steel Switching voltage min. 12 V Switching current min. at 24 V 10 m Connection connector, M12, 4-pin art no. 8000-430 1 N U 1 3 + 8000-430 yellow K 4 Note: he pressure filter control can be retrofitted. 10 30 V DC max. 200 m Return filter control Operating pressure Material 0 10 bar body polyamide, connecting parts steel galvanized, membrane NR, seal copper Code class I 67 Electrical connection cable socket DIN 43650 - F3 cable diameter 6 8 mm Max. switching voltage 30 V DC Max. switching current 0.25 Max. contact rating 3 W art no. 3887-121 Note: he return filter control can be retrofitted. 1 2 3 4 green 1 S2 3887-121 2 3 yellow 24 V DC max. 3 ohmic load E 197 7 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.1800

ower units in modular design type code for valve bloc for control circuits V1-XX X XXX SX to V4-XX X XXX SX ype code: MXX_XXX_V1-XX X XXX SX_V2-XX X XXX SX_V3-XX X XXX SX_V4-XX X XXX SX_EX he determination of control circuit V2-XX X XXX SX, V3-XX X XXX SX and V4-XX X XXX SX is the same as of control circuit V1-XX X XXX SX. Control valves Function as reserve space with blind plate 00 3/2 directional poppet valve, 500 bar, without auxiliary energy -> 1 x single acting 01 3/2 directional poppet valve, 500 bar, without auxiliary energy ->R 1 x single acting 02 3/2 directional poppet valve, 250 bar, without auxiliary energy -> 1 x single acting 03 3/2 directional poppet valve, 250 bar, without auxiliary energy ->R 1 x single acting 04 4/3 directional poppet valve, 500 bar, without auxiliary energy all connections closed 1 x double acting 05 4/3 directional poppet valve, 250 bar, without auxiliary energy all connections closed 1 x double acting 06 4/3 directional poppet valve, 500 bar, without auxiliary energy + ->R 1 x double acting 07 4/3 directional poppet valve, 250 bar, without auxiliary energy + ->R 1 x double acting 08 2 x 3/2 directional poppet valve, 500 bar, without auxiliary energy -> + 2 x single acting 09 2 x 3/2 directional poppet valve, 500 bar, without auxiliary energy + ->R 2 x single acting 10 2 x 3/2 directional poppet valve, 500 bar, without auxiliary energy -> / ->R 2 x single acting 11 2 x 3/2 directional poppet valve, 250 bar, without auxiliary energy -> + 2 x single acting 12 2 x 3/2 directional poppet valve, 250 bar, without auxiliary energy + ->R 2 x single acting 13 2 x 3/2 directional poppet valve, 250 bar, without auxiliary energy -> / ->R 2 x single acting 14 2 x 4/2 directional spool valve, 315 bar, without auxiliary energy -> / ->R 1x double-acting, not leakage-free 15 4/3 directional spool valve, 315 bar, without auxiliary energy all connections closed 1x double-acting, not leakage-free 16 4/3 directional spool valve, 315 bar, without auxiliary energy + ->R 1x double-acting, not leakage-free 17 4/3 directional spool valve, 315 bar, without auxiliary energy ->R, + closed 1x double-acting, not leakage-free 18 4/3 directional spool valve, 315 bar, without auxiliary energy all connections connected 1x double-acting, not leakage-free 19 without mounting plate, and R closed without XX _V1-XX X XXX SX_ ressure switch Flow control valves without system pressure switch for machine tool interlock 0 piston pressure switch in for machine tool interlock 1 piston pressure switch in for machine tool interlock 2 piston pressure switch in + for machine tool interlock 3 electronic system pressure switch in for machine tool interlock 4 electronic system pressure switch in for machine tool interlock 5 electronic system pressure switch in + for machine tool interlock 6 without flow control valve 0 with flow control valve in +, supply throttling, 500 bar 1 with flow control valve in +, supply throttling, 315 bar 2 ressure valves Check valves without pressure reducing valve 0 pressure reducing valve in with pressure display 1 pressure reducing valve and pressure relief valve in with pressure display 2 pressure reducing valve in with pressure display 3 pressure reducing valve in and pressure relief valve in with pressure display 4 pressure reducing valve in and pressure relief valve in with pressure display 5 pressure reducing valve in and pressure relief valve in + with pressure display 6 pressure relief valve in 7 pressure relief valve in 8 pressure relief valve in + 9 without intermediate plate check valves 0 intermediate plate twin check valves in + max. 315 bar 1 intermediate plate check valve in max. 315 bar 2 intermediate plate check valve in max. 315 bar 3 Switch 7.1800 without switch 0 hand switch, latching with pilot light green 1 foot switch, latching with pilot light green 2 3-way selector switch, latching with pilot light green 3 key switch, latching with pilot light green 4 2 x hand switch, latching with pilot light green 5 2 x foot switch, latching with pilot light green 6 2 x key switch, latching with pilot light green 7 Carr Lane Roemheld Mfg Co. Hilma-Römheld GmbH hone +49 (0) 2733 / 281-0 Fax +49 (0) 2733 / 198 hone 800-827-2526 Fax 636-386-8034 www.hilma-usa.com 8

ower units in modular design switching symbols switch variants Control valves Flow control valve Switching symbols Control valves a a DRSV pressure reducing valve, or 3/2 directional poppet valve V1-01 V1-03 a V1-02 V1-04 4/2 directional spool valve V1-15 R R R b V4 V3 V2 V1 Machine tool interlock iston pressure switch / electronic pressure switch Series mounting plate 4/3 directional poppet valve V1-05 V1-06 a with 4th switching function Solenoid "a" and "b" operated a+b a a+b R R R V1-07 V1-08 with 4th switching function Solenoid "a" and "b" operated R b b Valve block (max. 4 control circuits V1 V4) he equipment of the control circuits is based on the functional requirements of the application; the maximum pressures as well as the design-related differences in poppet and spool valves are to be considered. a a a Double 3/2 directional poppet valve V1-09 V1-12 V1-10 V1-13 V1-11 V1-14 b b b Special versions: Switch combinations and special switches are possible on request. It is also always possible to deviate from the prescribed standard. For example, more than 4 control circuits can be set up. It is possible to implement additional functions. he electrical control can be designed even more individually up to the installation of programmable logic controllers and touch panels for humanmachine communication. a a a a R R R R b b b b ressure switch 4/3 directional spool valve iston V1-16 pressure switch V1-17 V1-18 V1-19 V1-XX 1 V1-XX 2 V1-XX 3 50-550 bar 2 3 1 0-600 bar 8888 XXX bar Electronic pressure switch V1-XX 4 V1-XX 5 V1-XX 6 XXX bar Flow control valves ressure valves Flow control valve V1-XX X 1 V1-XX X 2 ressure reducing valve V1-XX X X1 M:G1/4 V1-XX X X3 M:G1/4 ressure reducing valve with pressure relief valve M:G1/4 V1-XX X X2 V1-XX X X7 ressure relief valve V1-XX X X9 V1-XX X X8 Check valves V1-XX X XX2 Intermediate plate twin check valve V1-XX X XX1 V1-XX X XX3 M:G1/4 V1-XX X X6 V1-XX X X4 V1-XX X X5 Switch Connecting cable 3 m, other lengths on request Manual switch Foot switch 3-way selector switch Key switch V1-XX X XXX S1 V1-XX X XXX S2 V1-XX X XXX S3 V1-XX X XXX S4 78,5 114 46 85 78,5 17 75 250 276 102,8 124 137 124 48 199 9 156 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.1800

ower units in modular design technical data ypes of valves oppet valves, hermetically sealed dm. operating pressure up to 500 bar dm. flow rate up to 20 l/min Flow direction in the direction of the arrow as per symbol Hydraulic oil HL 22 as per DIN 51524 Connection flange for mounting plate assembly ype of mounting 4 screws M 6 Nominal voltage 24 V DC, + 5 % / 10 % ick-up and holding power 30 W Make time 60 ms rake time 60 ms Max. cycles 2000 /h Duty cycle 100 % ED Code class I 65 ( IEC 60529 ) Connection cable socket as per DIN EN 175 301-803 and ISO 4400 Spool valves, leakage-afflicted Leakage rate up to 20 ccm/min at 100 bar dm. operating pressure up to 315 bar dm. flow rate up to 80 l/min Flow direction in the direction of the arrow as per symbol Hydraulic oil HL 32 or 46 as per DIN 51524 flange, hole pattern as per DIN 24340, Connection form CEO 4.2 4.3, ISO 4401 for mounting plate assembly ype of mounting 4 screws M 5 Nominal voltage 24 VDC, + 10 % / 10 % ick-up and holding power 30 W Make time 20 45 ms rake time 10 25 ms Max. cycles 15000 / h Duty cycle 100 % ED Code class I 65 as per DIN 40050 Connection cable socket as per DIN EN 175 301-803 and ISO 4400 Other voltages and/or actuations available on request Note to pressure reducing valves Max. input pressure: [bar] 500 djustable output pressure [bar] 30 380 (other pressure ranges on request) Note to pressure relief valves Max. input pressure: [bar] 500 djustable reaction pressure [bar] 50 500 (other pressure ranges on request) ressure switch variants Electronic pressure switches Recommended oil HL 22, 32 and 46 as per DIN 51524 ressure ranges 0 600 bar Excess pressure [bar] 50 % of the nominal pressure (N) ressure pick-up eak-value memory every 2 ms Operating voltage 12 to 32 V DC (residual ripple < 10 %), protected against reverse polarity Voltage drop < 2 V Current consumption < 60 m 2 x pnp switching, no/nc 1 Switching outputs short circuit protection switching output 2 is omitted if current output is parameterised Delay time 0 to 20 s, switch on and off delay separately adjustable Range of adjustment switching point 6 to 600 bar Reverse switching point 5 to 594 bar Switching frequency max. 125 Hz Reproducibility < ± 0.1 % of the final value if parameterized, switching output 2 is Current output omitted 0/4 to 20 m, 20 to 0/4 m, starting point and final point selectable Load max. RL [ W ] = (Ub 8V) / 20 m Error detection analog output in case of line break Rise time 5 ms (10 % to 90 % of N) Damping 0 to 20 s, adjustable Linearity deviation max. ± 0.25 % of N System pressure display 4 x 7 segment LED display Display damping 0 to 20 s, adjustable Switching function display 2x LED red Operating temperature 20 C to + 80 C emperature drift < ± 0.2 % / 10 K ( 10 C to + 70 C) ressure port G1/4, SW 19 Sensor head material stainless steel 1.4435 Housing material 6.6, polyester Code class I 65 as per EN 60529 Electric connection M12 connector 4-pin art no. 9740-050* s system pressure switch with teach-in function for easy system pressure adjustment For machine tool interlock art no. 9740-049* Mechanical pressure switch echnical data as per ROEMHELD data iston switch sheet F 9.732 * Detailed operating instructions available on request For the protection of pressure reducing valves, additional pressure relief valves are recommended. 7.1800 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 10 200

ower units in modular design type code for Electronics _EX ype code: MXX_XXX_V1-XX X XXX SX_V2-XX X XXX SX_V3-XX X XXX SX_V4-XX X XXX SX_EX Electronics he function triggering can be realized in various ways. he following are available for selection: without electric control, without terminal box connection of the individual components and electric control provided by the customer with terminal box, without electric control connections of the individual components are connected to the terminal strip of the terminal box, the connection will be made to the customer s electric control with electric control, without terminal box function triggering by customer contacts or selected switches _E X without electric control, without terminal box. 0 with terminal box 1 with electric control and function triggering provided by the customer 2 with electric control and function triggering in a common housing 3 with electric control and function triggering in individual housings 4 U = 3/ N / E 400 V 50 Hz Other voltages and frequencies of 1 h. 110 V to 3 h. 500 V 50/60 Hz on request Special approvals on request. Function triggering provided by the customer: otential free contacts from a customer control. Function triggering in a common housing: he selected switches in control circuits are installed in one operating housing and connected to the electrical control. Function triggering in individual housings: he selected switches in the control circuits are design as shown on page 9 of this series, and individually connected to the electric control. 201 11 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.1800

ower units in modular design technical data dimensions 3/8" 380 56 23 3/8" Example power unit 11 liters without 3/8" electronics _E0 343 384 409 384 409 398 409 398 427 593 398427 593427 300 593 611 323 24 39 24 24 25 67 67 67102 102 102 170 170 170 39 39 39 467 22 123 268 30 30 30 268 268 268 30 598 598 598 467 467 467 123 123 123 300 300 300 598 22 22 22 300 with terminal box _E1 300 300 300 170 25 427 250 250 343 250 384343 Ø9 Ø9 Ø9 14 14 47 14 47 47 25 593 R 1/2" R 67 R 1/2" 1/2" 102 4 x M8 4 x M8 4 x M8 261 261 261 380 380 399380 399 399 x x x 343 384 409 398 14 47 25 323 323 323 338 338 338 611 611 611 399 380 261 Ø9 250 3/8" 3/8" 24 3/8" 4 x M8 338 R 1/2" x 23 56 4 x M8 4 x M8 4 x M8 4 x M8 3/8" 380 380 380 23 23 56 56 3/8" 3/8" 3/8" 3/8" 3/8" with electric control _E2 18 18 18 189 189 189 30 7.1800 168 168 168 30 30 Dimensions in mm 533 533 533 168 305 305 305 533 189 400 18 400 400 30 400 305 Hilma-Römheld GmbH Carr Lane Roemheld Mfg Co. Schützenstraße 74Drive, 57271 Hilchenbach, Germany 927 Horan Fenton, MO 63026 hone +49800-827-2526 (0) 2733 / 281-0Fax Fax +49 (0) 2733 /www.hilma-usa.com hone 636-386-8034 12 202

ower units in modular design technical data dimensions Example power unit 11 liters (Dimensions in mm) ower unit 11 liters without electronics with terminal box with electric control x (motor 0.75 kw) 493 493 493 x (motor 1.1 kw) 509 509 509 x (motor 1.5 kw) 531 531 531 Reservoir volume ype code for example power unit art no. 11 M 03_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E0 8456004 11 M 03_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E1 8456003 11 M 03_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E2 8456002 203 13 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.1800

t Example power unit 27 / 40 / 63 liters without electronics _E0 3/8" 3/8" 3/8" 3/8" 23 56 u v u v with terminal box _E1 Ø 11 x 4 x M10 f Ø 11 4 x M10 o g k p q r 4 x M10 bf 4 x M10 ol hg k p q r i b l c h i c 2 123 30 2 300 m1 5 R 1/2" 3/8" 30 140 s 300 with electric control _E2 305 1 189 30 1 189 30 n 30 H1 400 n1 H1 t ower units in modular design technical data dimensions 23 56 300 m1 5 a d e x R 1/2" 123 30 3/8" 140 30 H 300 s 305 m n 30 H1 400 n1 a d H1 e H m Dimensions in mm 7.1800 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 14 204

ower units in modular design technical data dimensions Example power unit 27 / 40 / 63 liters (Dimensions in mm) Dimension table power unit 27 litres 40 litres 63 litres x (motor 0.75 kw) 661 691 741 x (motor 1.1 kw) 677 707 757 x (motor 1.5 kw) 699 729 779 x (motor 2.2 kw) 727 757 807 x (motor 3.0 kw) 784 834 a 433 463 513 b 491 525 615 c 724 758 848 403 485 539 1 579 662 712 2 513 596 646 d 548 578 628 e 567 597 647 f 326 341 423 g 366 381 463 h 515 549 639 H 779 809 859 H1 876 906 956 i 540 574 664 j 233 233 233 k 63 72 77 l 354 436 490 m 30 41 66 m1 34 45 70 n 446 476 526 n1 546 576 626 o 176 241 283 p 216 281 323 q 63 72 76 r 49 49 49 s 491 521 571 t 506 536 586 u 293 375 429 v 257 339 393 Reservoir volume ype code for example power unit art no. 27 M10_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E0 8457003 27 M10_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E1 8457002 27 M10_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E2 8457001 40 M22_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E0 8458003 40 M22_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E1 8458002 40 M22_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E2 8458001 63 M39_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E0 8459003 63 M39_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E1 8459002 63 M39_212_V1-054110 S0_V2-054100 S0_V3-074000 S0_V4-014000 S0_E2 8459001 205 15 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.1800

ower units in modular design example configurations MXX_1 intermittent cycle MXX_2_ unpressurised cycle, 500 bar MXX_XXX_V1-011000_ 1x single acting, 500 bar with MI in MXX_XXX_V1-XXXXXX_V2-000000_ 2. Valve combination as reserve space, closed with a blind plate for later retrofitting :G3/8 R:G1/2 8000 437 :G3/8 R:G1/2 8000 437 :G3/8 2450 261 :3/8 :G3/8 2450 261 :3/8 9740 050 0-600bar 0 8888 9740 050 0-600bar 0 8888 9730 500 50-550bar M:G1/4 M:G1/4 M1:G1/4 M2:G1/4 8000 438 M1:G1/4 M2:G1/4 8000 438 S2 2 1 3 3534 051 420 bar G1/4 M:G1/4 M:G1/4 2450 006 2450 006 2952 029 2363 326 a b Y0 2952 029 2363 324 M:G1/8 a Y1 500 bar 500 bar MXX_XXX_V1-053000_ 1x double acting, 500 bar with MI in + 2450 261 :G3/8 :3/8 MXX_XXX_V1-093000_ 2x single acting, 500 bar with MI in + 2450 261 :G3/8 :3/8 MXX_XXX_V1-050010_ 1x double acting, valve 500 bar pressure reduction in, 150 bar 2450 261 :G3/8 :3/8 9730 500 50-550bar 9730 500 50-550bar 9730 500 50-550bar 9730 500 50-550bar M:G1/4 M:G1/4 S3 2 1 3 3534 051 420 bar G1/4 M:G1/4 M:G1/4 S2 2 1 3 G1/4 420 bar 3534 051 S3 2 1 3 3534 051 420 bar G1/4 M:G1/4 M:G1/4 S2 2 1 3 G1/4 420 bar 3534 051 9822 000 0-250bar 150 bar 2953 850 2363 320 M:G1/8 M:G1/8 2363 374 M:G1/8 M:G1/8 M:G1/4 Y2 a b Y1 a Y1 b Y2 2363 320 M:G1/8 M:G1/8 :G1/4 :G1/4 Y2 a b Y1 MXX_XXX_V1-050020_ 1x double acting, valve 500 bar pressure reduction in, 150 bar MXX_XXX_V1-050030_ 1x double acting, valve 500 bar pressure reduction in, 150 bar MXX_XXX_V1-050060_ 1x double acting, valve 500 bar pressure reduction in, 150 bar 2450 261 :G3/8 :3/8 2450 261 :G3/8 :3/8 2450 261 :G3/8 :G3/8 M:G1/4 M:G1/4 M:G1/4 M:G1/4 M:G1/4 M:G1/4 2952 594 2953 854 2952 596 9822 000 150 bar 200 bar 2953 850 M:G1/4 200 bar 200 bar 2953 854 9823 000 0-400bar M:G1/8 150 bar 2363 320 M:G1/8 M:G1/8 9823 000 0-400bar M:G1/4 150 bar 30-380bar Y2 a b Y1 2363 320 M:G1/8 M:G1/8 2363 320 M:G1/8 M:G1/8 Y2 a b Y1 M:G1/4 MXX_XXX_V1-170201_ 1x double acting, 350 bar with twin flow control check valve and twin check valve 2450 261 :G3/8 :3/8 M:G1/4 Y2 a b Y1 MXX_XXX_V1-151000_ 1x double acting, 315 bar with MI in one of the two pressure lines is always under pressure 2450 261 :G3/8 :3/8 2951 591 9730 501 50-350bar 2957 403 S2 2 1 3 3534 051 250 bar G1/4 M:G1/4 M:G1/4 2457 220 2452 220 Y2 a b Y1 Y1 a b 7.1800 7.1800 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 16 206

Hydraulic power units Special designs ower units with large flow rate echnical data Max. flow rate 4.2 l/min. Max. operating pressure 400 bar Reservoir volume 9 l Oil port G 3 8 Hydraulic fluid Hydraulic oil HL 46 to DIN 51524 Motor voltage 380-420 V/50 Hz/3~ Motor rating 2.2 kw ype of valve oppet valves, leak-proof, max. 500 bar Valve voltage 24 VDC ype of protection I 54 Dimensions (LxxH) approx. 400 x 400 x 600 mm depending on flow rate and valve design Weight approx. 40-60 kg depending on design echnical data Max. flow rate 45 l/min. Max. operating pressure 400 bar Other technical data will be made available during the course of the project lanning and installation of complete oil- systems including complex electrical controls, designed to suit Hilma-Roemheld clamping elements used by our customers. Suitable for all clamping elements used on presses, especially on power and forging presses. Our large range of power units and clamping elements for presses enables us to meet your specific requirements. Frame-type power unit for 3 forging presses: 12 clamping circuits with pressure reduction for temperature compensation high pressure 4.2 l/min., 400 bar cooling return flow: 45 l/min., 10 bar 207 1 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 7.2500

Hydraulic power units ccessories and service Valve packages fastened to the press ram or the press bed 4-circuit valve packages with pump pressure switch echnical data Max. flow rate 8 l/min Oil port G 3 8 Hydraulic fluid Hydraulic oil HL 46 to DIN 51524 ype of valve Seat valves, leak-proof, max. 500 bar Solenoid voltage 24 V DC Other versions are available upon request. he service we offer you In addition to the cost effectiveness of our products, our customers also benefit from our efficient service. Our service includes preparation and installation of systems to suit specific applications manufacture, installation and commissioning of complete systems repair and maintenance of cylinders, clamping elements and power units supplied trouble-shooting and repair on the customer s premises constant repair service and fast response on our premises ll over the world our service is ready to act and to guarantee immediate help. Specially trained, experienced staff make sure that problems are solved rapidly and proficiently. You can rely on us! 7.2500 hone hone +49 800-827-2526 (0) 2733 / 281-0 Fax Fax 636-386-8034 +49 (0) 2733 / www.hilma-usa.com 2 208