SECOND FLOOR HEATING, VENTILATION & AIR CONDITIONING PLAN DRAWING INFORMATION NOTES PARTIAL MECHANICAL ROOM HVAC DETAIL SECOND FLOOR HVAC PLAN

Similar documents
Mechanical Technical Report 1

THE EFFICIENCY OF AIR DIFFUSION (E Z ) OF THE HIGH INDUCTION DAL 358 DIFFUSER REACHES. E z = 1.1

Phase 1 Remodeling for New State s Attorney Office Facility Will County Court Annex 57 N. Ottawa St & 57 W. Jefferson St.

Gallaudet University Sorenson Language and Communication Center

Technical Report 1. September 18, Erin Miller Mechanical Dr. Stephen Treado the Auditorium 1

Installation Instructions DNECOMZR020A02, DNECOMZR021A03 (For 3 to 12.5 Ton Units) and DNECOMZR062A00 (For RHS 12.5 Ton Heat Pump Units)

Installation Instructions

ENERGY STAR Certified Homes Clearing the Air: Ventilation. March 2, 2016

Installation Instructions

FDCLP2 Constant Volume Series Flow, Low Profile

CLOSELEIGH MANOR LAMBERT STREET WHITEHORSE, YUKON VENTILATION SYSTEM REPORT

Installation Instructions

Residential Energy Audit (Electrical) Internal Lighting Annual kwh Entertainment Equipment Annual kwh Laundry Annual kwh Tel: (03)

Optimizing System Performance

Installation Instructions

Engineering Bulletin. Recirculation Energy Recovery Unit Controls CLCH-PRB009-EN

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

ROUND CEILING DIFFUSERS DIMENSIONAL DETAILS

Water side Economizer WC chiller

Installation Instructions

Installation Instructions

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

5/12/2018 Climate Control - Control Components - Description and Operation 2009 Ford F-150 MotoLogic

ECONOMIZERS. 5/2012 Supersedes

Installation Instructions

Safety & Installation Instructions

Metasys Zoning Package Overview

SUMMARY OF PROPOSED CHANGES,

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

HEATING COOLING SYSTEM DESIGN

CERTIFICATE OF COMPLIANCE

FOR USE IN SOLUTION AIR HANDLING UNITS

Air Handling Unit Fan Selection Guide

CH5000 Heat Recovery Ventilator

Sketch Plans. for the Addition and Renovation of. BISHOP REDING CATHOLIC SECONDARY SCHOOL Milton, Ontario. September 26, 2018

Motors and Variable Speed Drives for Pumps and Fans. Reid Hart, PE

MAH. Modular Air Handling Unit

Samsung Modelling Guide for equest

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Design Makes All The Difference...

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

Installation Instructions

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

Installation Instructions

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

200, 9200 & 9200-VIB SERIES

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Installation Instructions

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTRUCTIONS 177R0076 INSTALLATION OF TOP AND BOTTOM COVERS FOR IP00 FRAMES D3, D4 & E2 INTO RITTAL ENCLOSURES

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

2001 Dodge Caravan Sport MANUAL A/C-HEATER SYSTEMS Caravan, Town & Country, & Voyager

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

VAHU Vertical Air Handling Unit

RHS. Product Specifications. PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP TONS (1 & 3 Phase)

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

ECM Motors Nonresidential HVAC Stakeholder Meeting #2

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

High Performance Fan Coils FCHG Genesis Series Horizontal

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.


New! Fluke 922 Airflow Meter. Fluke HVAC/IAQ Tools. Get more done.

M E M O R A N D U M. DATE: September 13, 2012 TO: Orcutt Winslow Partnership 3003 N. Central Ave. Phoenix, AZ Tracy Lee FROM: Michael Olson, CPD

Product Data. 50TCQ Packaged Heat Pump 3to12.5NominalTons C08613

GRAND UNION CANAL UXBRIDGE WEST LONDON UB8 2GH. Accommodation schedule. Block B

Product Data. 50HCQ High Efficiency Packaged Rooftop Heat Pump Units 3to10Tons C Except 04 models in single phase

Fan Powered Terminal Units FPV, FDV Series Variable Volume Parallel Flow

A. NU2035 HRV Specifications NU2035

Product Data. 50TCQ Packaged Heat Pump 3to12.5NominalTons C08613

MicroTech Applied Rooftop Unit Controller: VAV Control

ECON-ZIP-DETF; ZIP PACK

Centrifugal Inline Fans

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

Practical examples of installation in the TD range

C-BOA Tool. Comparison of Peak Demand Savings Estimation Methods. February 7, of 14

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

SINGLE DUCT AIR TERMINAL UNITS

Appendix A: Inputs, Outputs, and Parameters

KEES, INC. BALANCING MANUAL

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory.

SE8300 Series Installation Guide 24 Vac Low Voltage

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Pneumatic Valve 4V100 Series

Product Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015

Retro-Commissioning: Energy Hero In Plain Sight. Kevin Gombotz, PE

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

ICEMINI & Vertical MTI Units

Performance. Efficiency. & Comfort. Increase Productivity

Air Measuring Products AMD AMS IAQ

Transcription:

SECOND FLOOR HEATING, VENTILATION & AIR CONDITIONING PLAN DRAWING INFORMATION NOTES Ram Auburn Hospitality, LLC 600 Martin Luther Kg Jr Pkwy Phenix City, AL 36869 (706) 660-5616 Bradley, Schmidt & Carn A r c h i t e c t u r e, P L L C (334) 794-2224 256 Honeysuckle Road, Suite #7 Dothan, AL 36305 Fax (334) 794-2245 P.O. Box 1663 Dothan, AL 36302 PARTIAL MECHANICAL ROOM HVAC DETAIL SECOND FLOOR HVAC PLAN

THIRD FLOOR HEATING, VENTILATION & AIR CONDITIONING PLAN DRAWING INFORMATION NOTES Ram Auburn Hospitality, LLC 600 Martin Luther Kg Jr Pkwy Phenix City, AL 36869 (706) 660-5616 Bradley, Schmidt & Carn A r c h i t e c t u r e, P L L C (334) 794-2224 256 Honeysuckle Road, Suite #7 Dothan, AL 36305 Fax (334) 794-2245 P.O. Box 1663 Dothan, AL 36302 THIRD FLOOR HVAC PLAN

DRAWING INFORMATION NOTES FOURTH FLOOR HEATING, VENTILATION & AIR CONDITIONING PLAN Ram Auburn Hospitality, LLC 600 Martin Luther Kg Jr Pkwy Phenix City, AL 36869 (706) 660-5616 Bradley, Schmidt & Carn A r c h i t e c t u r e, P L L C (334) 794-2224 256 Honeysuckle Road, Suite #7 Dothan, AL 36305 Fax (334) 794-2245 P.O. Box 1663 Dothan, AL 36302 FOURTH FLOOR HVAC PLAN

Building: System Tag/Name: Operating Condition Description: Units (select from pull-down list) Courtyard by Marriott Auburn, AL DOAS1, & DOAS2 24 hours IP w/o diversity w/ diversity Inputs for System Name Units System Diversity System Check Figures Floor area served by system As sf 9,871 Population of area served by system Ps P 195 D 100% 195 19.8 P/1000 sf Design primary supply fan airflow rate Vpsd cfm 9,871 100% 9,871 1.00 cfm/sf OA req'd per unit area for system (Weighted average) Ras cfm/sf 0.10 0.10 ave cfm/sf OA req'd per person for system area (Weighted average) Rps cfm/p 6.7 6.66 ave cfm/p Percent increase in Vbz over minimum required 0% Inputs for Potentially Critical zones Potentially Critical Zones Zone Name CORR - 43 ELECT - 120 PBX - 31 CORR - 30 CORR - 18 CORR - 41 MAINT/ELECT - 16 ASHRAE 62.1-2010 VENTILATION CALCULATIONS LINEN - 11 LAUNDRY - 09 EMPLOYEE BREAK - 10 MANAGER - 06 SALES - 05 VESTIBULE - 01 RECEPTION/ MARKET - 03 WORK ROOM - 04 GUEST LAUNDRY - 20 EXERCISE - 19 LOUNGE - 23 RECEPTION LOUNGE/CAF É - 40 MEETING ROOM - 27 MEDIA PODS MEETING STORAGE - 25 KITCHEN - 38 STORAGE - 37 Zone Tag enter tag enter tag New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID New zone ID Occupancy Category Corridors Electrical equipment Electrical equipment Corridors Corridors Corridors Electrical equipment Storage rooms Laundry rooms, Break rooms Office space Office space Lobbies Reception areas Office space Laundry rooms, Health club/weight Bars, cocktail lounges Bars, cocktail lounges Multipurpose assembly Multipurpose assembly Storage rooms Kitchen (cooking) Storage rooms Select from pull-down list: rooms rooms rooms central central rooms Floor Area of zone Az sf 530 120 60 129 662 305 150 112 480 192 158 92 153 575 168 132 830 1,431 1,233 1,164 265 70 484 100 9,595 total sf Design population of zone Pz P (default value listed; may be overridden) 0 0 0 0 0 0 0 0 5 4 1 1 5 17.25 3 1.32 8.3 25 45 60 9 0 9.68 0 194.55 total P Design total supply to zone (primary plus local recirculated) Vdzd cfm 530 120 60 129 662 305 150 112 480 192 158 92 153 575 168 132 830 1,431 1,233 1,164 265 70 484 100 9,595 total cfm Induction Terminal Unit, Dual Fan Dual Duct or Transfer Fan? Select from pull-down list or leave blank if N/A: Frac. of local recirc. air that is representative of system RA Er 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 1.00 average Inputs for Operating Condition Analyzed Percent of total design airflow rate at conditioned analyzed Ds % May need to manually edit Ds: 97% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% average Air distribution type at conditioned analyzed Select from pull-down list: CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH CSCRH Zone air distribution effectiveness at conditioned analyzed Ez 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 average Primary air fraction of supply air at conditioned analyzed Ep 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 average Results System Ventilation Efficiency Ev 0.67 Outdoor air intake required for system Vot cfm 3436 Outdoor air per unit floor area Vot/As cfm/sf 0.35 Outdoor air per person served by system (including diversity) Vot/Ps cfm/p 17.6 Outdoor air as a % of design primary supply air Ypd % 35% Totals/averages Detailed Calculations Initial Calculations for the System as a whole System primary supply air flow at conditioned analyzed Vps cfm = Vpsd Ds = 9595 Uncorrected OA intake flow req'd for system Vou cfm = Rps Ps + Ras As = 2317 Uncorrected OA req'd as a fraction of primary SA Xs = Vou / Vps = 0.24 Initial Calculations for individual zones Area outdoor air rate Ra cfm/sf 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.12 0.12 0.12 0.06 0.06 0.06 0.06 0.06 0.12 0.06 0.18 0.18 0.06 0.06 0.12 0.12 0.12 People outdoor air rate Rp cfm/p 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 20.00 7.50 7.50 5.00 5.00 0.00 7.50 0.00 Total supply air to zone (at condition being analyzed) Vdz cfm Vdzd Ds 530 120 60 129 662 305 150 112 480 192 158 92 153 575 168 132 830 1431 1233 1164 265 70 484 100 9595 Primary airflow to zone (at condition being analyzed) Vpz cfm = Vdz Ep = 530 120 60 129 662 305 150 112 480 192 158 92 153 575 168 132 830 1431 1233 1164 265 70 484 100 9595 Breathing zone outdoor airflow Vbz cfm = Rp Pz + Ra Az = 32 7 4 8 40 18 9 13 83 43 14 11 34 121 25 22 216 445 559 370 61 8 131 12 2286 Zone outdoor airflow Voz cfm = Vbz / Ez = 40 9 5 10 50 23 11 17 103 54 18 13 43 151 31 28 270 556 699 462 76 11 163 15 2858 Fraction of zone supply not directly recirc. from zone Fa = Ep + (1-Ep) Er = 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Fraction of zone supply from fully mixed primary air Fb = Ep = 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Fraction of zone OA not directly recirc. from zone Fc = 1-(1-Ez)(1-Ep)(1-Er) = 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 OA fraction required in the supply air to the zone Zd = Voz / Vdz = 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.15 0.22 0.28 0.11 0.14 0.28 0.26 0.19 0.21 0.33 0.39 0.57 0.40 0.29 0.15 0.34 0.15 0.57 Maximum Zd OA fraction required in the primary air to the zone Zpz = Voz / Vpz = 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.15 0.22 0.28 0.11 0.14 0.28 0.26 0.19 0.21 0.33 0.39 0.57 0.40 0.29 0.15 0.34 0.15 0.57 Maximum Zpz System Ventilation Efficiency Zone Ventilation Efficiency (App A Method) Evz = (Fa+FbXs-FcZpzEp)/Fa = 1.17 1.17 1.17 1.17 1.17 1.17 1.17 1.09 1.03 0.96 1.13 1.10 0.96 0.98 1.05 1.03 0.92 0.85 0.67 0.84 0.95 1.09 0.90 1.09 System Ventilation Efficiency (App A Method) Ev = min (Evz) = 0.67 System Ventilation Efficiency (Table 6.3 Method) Ev = Value from Table 6.3 = n/a Minimum outdoor air intake airflow Outdoor Air Intake Flow required to System Vot cfm = Vou / Ev = 3436 OA intake req'd as a fraction of primary SA Y = Vot / Vps = 0.36 Outdoor Air Intake Flow required to System (Table 6.3 Method) Vot cfm = Vou / Ev = n/a OA intake req'd as a fraction of primary SA (Table 6.3 Method) Y = Vot / Vps = n/a OA Temp at which Min OA provides all cooling OAT below which OA Intake flow is @ minimum Deg F = {(Tp-dTsf)-(1-Y)*(Tr+dTrf)}/Y = 25 1337 APRIL 18, 2014 Ram Auburn Hospitality, LLC 600 Martin Luther Kg Jr Pkwy Phenix City, AL 36869 (706) 660-5616 Bradley, Schmidt & Carn A r c h i t e c t u r e, P L L C (334) 794-2224 256 Honeysuckle Road, Suite #7 Dothan, AL 36305 Fax (334) 794-2245 P.O. Box 1663 Dothan, AL 36302 ASHRAE 62.1-2010 VENTILATION CALCULATIONS