SECTION A8 LUBRICITY

Similar documents
Revision 4 May 23, 2018

TIRE TREAD APPLICATIONS

CONDUCTIVE COMPOUNDS. CABELEC Conductive Compounds Product Selection Guide

Hybrid Electric Vehicle End-of-Life Testing On Honda Insights, Honda Gen I Civics and Toyota Gen I Priuses

Drilling Specialties Company a division of Chevron Phillips Chemical Company LP. Main Office:

CABELEC Conductive Compounds Product Selection Guide

SPECIALTY CARBON BLACKS HIGH PERFORMANCE MATERIALS FOR ADVANCED LITHIUM-ION BATTERIES

A Critical Assessment of Synthetic Lubricant Technologies for Alternative Refrigerants

CONDUCTIVE COMPOUND AND CONCENTRATES CABELEC CONDUCTIVE COMPOUNDS AND CONCENTRATES PRODUCT SELECTION GUIDE

Application Note #1013 Measuring the Behavior of Brake Materials More Efficiently: Correlation Between Benchtop and Dynamometer Tests

HCFC-22 Retrofits. There has been increased emphasis on retrofitting R-22

Neutral Oils : 60R, 110RVL, 100R, 150R, 220R, 600R

Revision 9 January 9, 2019

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

Low-torque Deep-groove Ball Bearings for Transmissions

MASTER \ C. Idaho National Engineering Laboratory. INEL 96J014t we.l~%/0o/60 PREPRINT. MOTOR-OPERATOR GEARBOX EFFICIENCY 5 i u.

High Performance Industrial Lubricants for Food and Beverage Processing

SPECIALTY CARBON BLACKS HIGH PERFORMANCE MATERIALS FOR ADVANCED LEAD ACID BATTERIES

Journal of KONES Powertrain and Transport, Vol. 21, No ISSN: e-issn: ICID: DOI: /

THERMOELECTRIC SAMPLE CONDITIONER SYSTEM (TESC)

Diesel Power. Advanced synthetic technology to protect today s most demanding diesels. SYNTHETIC DIESEL OILS. FuEL.

Mobil SHC 600 Series. Exceptional Performance Gear and Bearing Oils. Product Description. Features and Benefits

PATENTED TECHNOLOGY» PROVEN RESULTS» PAYBACK

Product Description. Mobil SHC 600 Series. Mobil Industrial, Canada. Exceptional Performance Gear and Bearing Oils

High Performance Industrial Lubricants for Food and Beverage Processing

ENERGY ANALYSIS OF A POWERTRAIN AND CHASSIS INTEGRATED SIMULATION ON A MILITARY DUTY CYCLE

Over-the-Road Trucks SYNTHETIC MOTOR OILS. FuEL. FLuIdS

Over-the-Road Trucks. FuEL FLuIdS SYNTHETIC MOTOR OILS

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 2900 MIXER TO BE USED BY CNRL FOR BITUMEN VISCOSITY CONTROL Report R0. By Kimbal A.

Beyond Standard. Dynamic Wheel Endurance Tester. Caster Concepts, Inc. Introduction: General Capabilities: Written By: Dr.

White Paper. Electromechanical Actuators in the Automotive Industry Roller screw actuators for weld gun applications

Synthetic Gear Oil Selection Dennis Lauer

Influence of fuel properties and aftertreatment techn. on particles in tailpipe and ambient air

High Capacity Tapered Roller Bearings

Product Loss During Retail Motor Fuel Dispenser Inspection

Determination of Volume Correction Factors for FAME and FAME / Mineral-diesel blends

Filtercake Breaker Evaluation Pitfalls: Lessons Learned Through Testing

Series A Construction

PCMO3. Fuel Economy & Engine Durability Predictor Test. Alternatives to ASTM D7589 & ILSAC SEQ 6E

Wear prevention characteristics of binary oil mixtures

ASTM D for Denatured Fuel Ethanol Automating Calculations and Reports with Empower 2 Software

NOVAGUARD 890. PRODUCT DATA SHEET January 21, 2015 (Revision of December 12, 2014) DESCRIPTION

UPDATE OF THE SURVEY OF SULFUR LEVELS IN COMMERCIAL JET FUEL. Final Report. November 2012

Fidmash. Coiled Tubing and Pressure Pumping Equipment

DaimlerChrysler Alternative Particulate Measurement page 1/8

Accelerating the Development of Expandable Liner Hanger Systems using Abaqus

Solvay/ Torlon Thrust Bearing Discussion Torlon Versus Vespel Brian Stern

NOVAGUARD 840. PRODUCT DATA SHEET January 21, 2015 (Revision of December 12, 2014) DESCRIPTION

Bisnet Solutions for Tomorrow, Today! The Die Casting Process Planner. Users Manual. August 5, A Product By: Bisnet - 1 -

International Journal of Scientific & Engineering Research, Volume 6, Issue 11, November ISSN

ProOne Downhole Drilling Fluid

Estimation Procedure for Following Vapor Pressure Changes

Other significant updates include:

The PMAC Dynamic Scale Loop

-5 F to 620 F. High Performance, Low-pressure Heat Transfer Fluid. Heat Transfer Fluid by Solutia. Technical Bulletin A +400 C +700 F +350 C

High Accuracy Bunker Blending / Bunker Control

RENEP CGLP. High-performance slideway oils for machine tools, with excellent demulsification properties. Description. Advantages

ASTM B117 Testing Quality Control

AADE-05-NTCE-60. The Current (and Problematic) State

ESD Tests on Protektive Pak Versus Coated ESD Boxes

THERMINOL LT. heat transfer fluid. Wide temperature range, liquid/vapor phase fluid to 315 C. (--103 to 600 F)

The Effect of Spring Pressure on Carbon Brush Wear Rate

High Accuracy Bunker Blending / Bunker Control

International Conference on Advances in Energy, Environment and Chemical Engineering (AEECE-2015)

Operating Efficiency of Crankshaft Drive Pumps

HiPer-tex fibre for light weight, cost effective blast and ballistic protection solutions

ONYX 360. Rolling PDC cutter

RECYCLABILITY EVALUATION PROTOCOL FOR PE FILMS

SSC Sensor Replacement Board for the SSC Evaluation Kit. Features. Benefits

EXPERTLY ENGINEERED FULL FLOW OIL FILTERS FOR HEAVY DUTY ENGINES

AxeBlade. Ridged diamond element bit

Sarasota FD900 Sarasota ID900 Sarasota PD900 Gas Density Meters for Gas Metering and Control

Experience with a new 200 C Triple-Combo LWD system

700 Type P & PK DC Relays Timer Units Latch Units Series A and B Construction. Renewal Parts

White paper: Originally published in ISA InTech Magazine Page 1

Effects of wet lubrication on Bal Seal spring-energized seal performance

FOR COMMERCIAL ON-HIGHWAY HEAVY-DUTY PROTECTION CHOOSE DELO

Combustion PVM-MF. The PVM-MF model has been enhanced particularly for dualfuel

VALVOLINE HYDRAULIC OILS PEOPLE WHO KNOW USE VALVOLINE

LOW TEMPERATURE OPERABILITY STARTABILITY & CHARACTERISTICS

SIGMADUR 520. PRODUCT DATA SHEET December 12, 2014 (Revision of May 01, 2013) DESCRIPTION

Burn Characteristics of Visco Fuse

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

EXPERTLY ENGINEERED FULL FLOW OIL FILTERS FOR HEAVY DUTY ENGINES

THERMINOL 72. heat transfer fluid. High temperature, excellent stability at medium pressure. -14 to 380 C. (7 to 715 F)

FORWARD-LOOKING INFORMATION

The following report discusses effect on HTHS Viscosity of Proton's Engine Oils by addition of X-1R Engine Treatment.

Forane 427A Refrigerant

Submittal Data. Fiberglass Bondstrand 2000 Pipe pe

Global Oilfield Solutions. Performance Chemicals for Drilling

Polyurea Spray Coatings

Outstanding. Valve Stem Packings. Teadit 010-ELE (Extremely Low Emissions) Combo Set Valve Stem Packings for Extreme Emission Control

505 Size 5 Series A Construction

Simulation and Validation of FMVSS 207/210 Using LS-DYNA

EN. SKF Grease Spraying System For Large Open Gears. Extend the lifetime of large gear drives

EXPERIMENTAL INVESTIGATION OF THE EFFECT OF HYDROGEN BLENDING ON THE CONCENTRATION OF POLLUTANTS EMITTED FROM A FOUR STROKE DIESEL ENGINE

Model Speed Viscometer. Features DRILLING FLUIDS EQUIPMENT

UCON Hydrolube HP-5046D

OPTIMIZATION STUDIES OF ENGINE FRICTION EUROPEAN GT CONFERENCE FRANKFURT/MAIN, OCTOBER 8TH, 2018

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Transcription:

FORMATE TECHNICAL MANUAL C A B O T CHEMICAL AND PHYSICAL PROPERTIES SECTION A8 LUBRICITY A8.1 Introduction...2 A8.2 Lubricity tests from HLT Lubricity Tester...2 A8.2.1 Instrument description...2 A8.2.2 Test fluids and conditions...2 A8.2.3 Test procedure...2 A8.2.4 Results...2 A8.3 Lubricity tests from Baroid Lubricity Tester... 4 A8.4 Lubricity tests from BP Side Load Lubricity Tester... 4 A8.4.1 Instrument description...4 A8.4.2 Test fluids and conditions...4 A8.4.3 Test procedure...4 A8.4.4 Test results...4 References... 4 The Formate Technical Manual is continually updated. To check if a newer version of this section exists please visit formatebrines.com/manual NOTICE AND DISCLAIMER. The data and conclusions contained herein are based on work believed to be reliable; however, CABOT cannot and does not guarantee that similar results and/or conclusions will be obtained by others. This information is provided as a convenience and for informational purposes only. No guarantee or warranty as to this information, or any product to which it relates, is given or implied. CABOT DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AS TO (i) SUCH INFORMATION, (ii) ANY PRODUCT OR (iii) INTELLECTUAL PROPERTY INFRINGEMENT. In no event is CABOT responsible for, and CABOT does not accept and hereby disclaims liability for, any damages whatsoever in connection with the use of or reliance on this information or any product to which it relates. 2013 Cabot Corporation, MA, USA. All rights reserved. CABOT is a registered trademark of Cabot Corporation.

CABOT FORMATE TECHNICAL MANUAL A8.1 Introduction With the increase in extended reach and horizontal drilling, the need for low torque and drag factors is becoming more imperative. In turn, fluid lubricity is an increasingly important factor in choosing the optimum fluid for the operation. Several different tools are available for measuring friction in the laboratory. Result quality varies a lot. Large or full scale laboratory equipment has been shown to provide the most accurate results. The coefficient of friction (COF) is defined as the ratio of the static or kinetic friction force to the normal force. The metal-to-metal and metal-to-sandstone friction coefficients for formate-based fluids have been measured in the HLT Lubricity Tester at Westport Technology Center in Houston and in the BP lubricity testing rig in Sunbury. In addition to these large scale tests, tests have also been carried out on the Baroid Lubricity Tester, which is typically applied in the industry as a first-pass measurement. Only the lubricity of the formate brines themselves are discussed in this chapter. The effect of adding lubricants to formate-based drilling fluids is discussed in Section B5, Compatibility with Additives. A8.2 Lubricity tests from HLT Lubricity Tester A8.2.1 Instrument description The HLT Lubricity Tester at Westport Technology Center in Houston is a result of a Joint Industry Project between MI Drilling Fluids and BP Exploration to develop an instrument to measure the friction coefficient of drilling fluids under simulated field conditions. The instrument developed in the late eighties (Figure 1) is now jointly owned and operated by MI Swaco and Westport Technology Center International. Results obtained by the instrument have been verified with field data, and the instrument is considered today s industry standard. The Lubricity Tester is supported on a lathe bed and is designed to measure the coefficient of friction of metalto-metal, metal-to-sandstone, and metal-to-shale at temperatures up to 121 C / 250 F with pressure and variable torque under automated control. Figure 1 Westport / MI Drilling Fluids HLT Lubricity Tester. A8.2.2 Test fluids and conditions HLT lubricity tests were run on a series of potassium and cesium formate brine blends, varying in density from 1.60 to 2.28 g/cm 3 / 13.34 to 19.0 lb/gal [1]. Water was tested and used as a baseline measurement. Testing consisted of: Metal-to-metal: The metal test bob is composed of carbon steel (Rockwell hardness C 37) and is 3 inches long and 2.5 inches in diameter. The metal insert is composed of a cut section of N-80, 4.5 inch tubing. Metal-to-sandstone: Metal-to-Berea sandstone (200 md) contact Metal-to-shale: Contacts metal-to-pierre II shale contact Tests were carried out at temperatures of 24, 66, 93, and 124 C / 75, 150, 200, and 225 F. The cell pressure was 1.72 MPa / 250 psi. A8.2.3 Test procedure The HLT Lubricity Tester was calibrated with water. For all measurements, a contact of 150 rpm and 75 lbf was used. Each sample was circulated at a constant flow rate of 2 gallons/minute during each test. Each COF test was run using the test protocol of the HLT machine. Each test was a run of nine series, with 50 data points per series and an average of 25 readings per data point. The COF was determined as the average for each test. A8.2.4 Results Test results (Table 1) indicate that potassium and cesium formate brines and their blends are extremely lubricious, significantly reducing coefficient of friction (COF) values from that of water (Table 2). The average coefficient of friction values are also compared to water, with the percentage reduction shown. PAGE 2 SECTION A8

SECTION A: CHEMICAL AND PHYSICAL PROPERTIES CABOT Table 1 COF for potassium / cesium formate fluid blends, measured by the HLT Lubricity Tester and the Baroid Lubricity Tester. Brine Water 1.60 g/cm 3 / 13.3 lb/gal 1.77 g/cm 3 / 14.8 lb/gal 1.94 g/cm 3 / 16.2 lb/gal 2.11 g/cm 3 / 17.6 lb/gal CsFo 2.28 g/cm 3 / 19.0 lb/gal Metal-to-metal 24 C 75 F 0.3640 0.1391 0.1437 0.1446 0.1561 0.1227 66 C 150 F 0.3595 0.1745 0.1496 0.1526 93 C 200 F 0.3647 0.1963 0.1705 0.1661 107 C 225 F 0.3399 0.1802 0.1856 0.1857 Baroid L. M. 0.355 0.075 0.100 0.105 0.110 0.103 Metal-to-sandstone 24 C 75 F 0.5209 0.1281 0.0944 0.1267 66 C 150 F 0.5299 0.1589 0.1303 0.1557 93 C 200 F 0.5267 0.1723 0.1313 0.1513 107 C 225 F 0.4970 0.1695 0.1318 0.1813 Metal-to-shale 24 C 75 F 0.4524 0.1574 0.1442 0.1358 0.1588 0.1590 66 C 150 F 0.6276 0.2107 0.1854 0.2066 93 C 200 F 0.5859 0.2190 0.2459 0.2395 107 C 225 F 0.5750 0.2177 0.2587 0.2506 Table 2 Percentage reduction of COF from that of water for potassium / cesium formate blends, measured by the HLT Lubricity Tester. Brine 1.60 g/cm 3 / 13.3 lb/gal [%] 1.77 g/cm 3 / 14.8 lb/gal [%] 1.94 g/cm 3 / 16.2 lb/gal [%] 2.11 g/cm 3 / 17.6 lb/gal [%] CsFo 2.28 g/cm 3 / 19.0 lb/gal [%] Metal-to-metal 24 C 75 F 61.79 60.52 69.98 57.12 66.29 66 C 150 F 51.46 58.39 57.55 93 C 200 F 46.17 53.25 54.46 107 C 225 F 46.98 45.40 45.37 Metal-to-sandstone 24 C 75 F 75.41 81.88 75.68 66 C 150 F 70.01 75.41 70.62 93 C 200 F 67.29 75.07 71.27 107 C 225 F 65.90 73.48 63.46 Metal-to-shale 24 C 75 F 65.21 68.13 66.00 64.90 64.85 66 C 150 F 66.43 70.46 67.08 93 C 200 F 62.62 58.37 59.12 107 C 225 F 62.14 55.01 56.42 Reductions are seen in the range of 46% to 66% (metalto-metal), 63% to 82% (metal-to-sandstone), 55% to 70% (metal-to-shale). These low COF trends were seen at all test temperatures. Comparison with water-based, oil-based, and syntheticbased drilling fluids, all formulated with lubricants, also confirms very low coefficient of friction for formate brines (Table 3). SECTION A8 PAGE 3

CABOT FORMATE TECHNICAL MANUAL Table 3 Coefficient of friction (COF) of various fluid types measured using the HLT Lubricity Tester. Fluid A8.3 Lubricity tests from Baroid Lubricity Tester The potassium / cesium formate blends above were also tested in the Baroid Lubricity Tester, according to API procedures. Test parameters were 60 rpm, metalto-metal contact, 150 inch-lbs of torque. Each test was run for five minutes. The results from these tests are included in Table 1. A8.4 Lubricity tests from BP Side Load Lubricity Tester A8.4.1 Instrument description The Sunbury lubricant test device is a small scale model of a drilling rig. The drill pipe is replaced with a 1" OD steel shaft that rotates inside of a 1 1/2" ID steel casing. The casing is supported on linear bearings and can be moved from side to side. The contact length of the casing and the shaft is 74.1 cm / 2.43 ft. Side loads are applied via a pulley system on the casing so that the inside of the casing is pressed against the steel shaft. An air motor on the top powers the shaft. A torque transducer is mounted between the air motor and the shaft and records the torque. A tachometer monitors rotary speed. The mud circulation system consists of a vessel with a volume of about 1.32 gal, which can be heated to 65 C / 149 F. The mud is circulated through the annulus from the bottom to the top. A logging unit captures data from the rig (torque, temperature, and rotation speed). A8.4.2 Test fluids and conditions Metal-tometal Metal-tosandstone Water-based, 15.0 lb/gal 1) 0.264 0.338 Diesel-based, various weights 1) 0.180 0.223 Mineral-based, various weights 1) 0.223 0.231 Synthetic-based, various weights 1) 0.181 0.253 Potassium / cesium formate 2) 0.162 0.144 1) Average COFs over several years measured with same instrument 2) Average COFs over all temperatures Testing has been conducted on various concentrations of all three formate brines [2] along with a series of other brines. The brines were diluted with deionized water. A8.4.3 Test procedure Rotation speed 120 rpm (field condition) Pump rate: 1.89 gpm (7.12 liter/min). Equivalent to 500 gpm in the field. Variations were shown to have minimal impact Side loads: 31, 21, and 11 kg. Representative for true field conditions. Straight shaft was used (variations shown to have minimal impact) Temperature: All tests were run at standard temperature 25 C / 77 F. Heating caused by friction led to actual temperatures up to 30 C / 86 F) Duration: Each test was run for 15 minutes. This was found to give stable test results The general procedure started with a two-minute run without any weights to find the tare torque. A side load of 31 kg / 68.3 lbs was then applied for 15 minutes, followed by a two-minute break to re-establish the tare torque. The run was then continued with a side load of 21 kg for 15 minutes, followed by a two-minute break, and finally a side load of 11 kg for 15 minutes. Average COF was calculated based on the average of the three last minutes of each load. A8.4.4 Test results The results for the formate brines are shown in Figure 2 and Figure 3. As expected, the coefficients of friction for the individual formate brines are dependent on the concentration. At high concentrations, both potassium and cesium formate are as lubricious as oil-based muds measured in the same study. At lower concentrations, typically sodium formate and the lower sodium / potassium formate density range, formate brines will benefit from addition of a lubricant (see part B of the manual). For all brine systems tested in this study, it was concluded that the lubricity of the brine could be best correlated to brine viscosity. The lubricity was found to be higher with increased brine viscosity. It is important to note that this relationship applies to the viscosity of the formate brine itself and not the bulk viscosity of the fluid. Therefore, simply viscosifying a formate brine will not necessarily improve its lubricity. For cesium formate, particularly at a given density, lubricity of the potassium / cesium formate blend will be better than lubricity of a diluted cesium formate fluid. References [1] Spreadsheet Friction Coefficient.xls, Westport Technology Center International. [2] Pingitzer, G.: Lubricity of Drilling and Completion Fluids The Influence of metal type on friction, Master Thesis, University of Leoben, Austria. PAGE 4 SECTION A8

SECTION A: CHEMICAL AND PHYSICAL PROPERTIES CABOT Pure water Potassium formate mild steel 0.70 0.60 Coefficient of friction (COF) 0.50 0.40 0.30 0.20 WBM OBM 0.10 0.00 1.0 1.1 1.2 1.3 1.4 1.5 1.6 Density [g/cm 3 ] 31 kg side load 21 kg side load 11 kg side load Figure 2 Metal-to-metal COF for potassium formate as a function of brine concentration for mild steel. Measurements are conducted using the Sunbury Lubricity Tester. Pure water Cesium formate mild steel 0.70 0.60 Coefficient of friction (COF) 0.50 0.40 0.30 0.20 WBM OBM 0.10 0.00 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 2.3 Density [g/cm 3 ] 31 kg side load 21 kg side load 11 kg side load Figure 3 Metal-to-metal COF for cesium formate as a function of brine concentration for mild steel. Measurements are conducted using the Sunbury Lubricity Tester. SECTION A8 PAGE 5