Dewatering Submersible sewage pumps

Similar documents
Series description: Wilo-Drain STS 40

Series description: Wilo-Drain MTC

Sewage transport Submersible pumps

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)

Series description: Wilo-Drain TM/TMW/TMR 32

Series description: Wilo-Drain TM/TMW/TMR 32

Series description: Wilo-DrainLift KH 32

Drainage and Sewage Wastewater Transport and Dewatering

Pressure boosting Single pumps

Series description: Wilo-MultiCargo MC

SL B. Grundfos pump GRUNDFOS DATA BOOKLET

Data sheet: Wilo-Economy MHI 202 (3~400 V, EPDM)

Series description: Wilo-Sub TWI 6-..-B

SEV D. Grundfos Pump GRUNDFOS DATA BOOKLET

SE M.C.N.51D

waste water and sewage pumps

ABS submersible sewage pump AFP

VX-ST VORTEX. Submersible pumps in stainless steel. PERFORMANCE RANGE Flow rate up to 650 l/min (39 m³/h) Head up to 15 m

Data sheet: Wilo-Multivert MVI 205 (3~400 V, EPDM, PN 16)

Design details Design. Installation types. Shaft seal. Impeller type. Drive. Bearings

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16)

Series description: Wilo-TOP-S

Data sheet: Wilo-Multivert MVI 404 (1~230 V, EPDM, PN 16)

Series description: Wilo-MultiCargo FMC

SDL i MACERATING SUBMERSIBLE PUMPS

Data sheet: Wilo-CronoLine-IL 125/210-5,5/4

TRITUS. Submersible pumps with grinder

Data sheet: Wilo-CronoLine-IL 65/160-5,5/2

Pumps stations and solids separation systems

HOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400

- continuos running: max ±5%. - intermittent running: max ±10%. Voltage imbalance between phases: max 2%. Maximum number of starts per hour: 30.

Unilift CC 7-A1 (240V,0.25kW, L/sec,1-7m)

JUNG PUMPEN MULTICUT SEWAGE PUMPS

Aqualift F XL Lifting Stations

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Priox. The new range NOCCHI. Lenntech NOCCHI. Tel Fax waste water treatment

COLLECTION STATIONS AND WASTE WATER LIFTING DESIGN SPECIFICATIONS

Position Qty. Description Single Price 1 SEV B

SUBMERSIBLE PUMP RANGE

Ama Porter. 50 Hz. Submersible motor pumps

FVO. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 4 pole - 50 Hz OPERATING LIMITS APPLICATIONS BENEFITS SPECIFICATIONS

blue series bluepro series

GRUNDFOS WASTEWATER. S range kw. 50 and 60 Hz versions

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80

CONTENTS. Purpose Model meaning Conditions of use Rotating direction Structures description...02

MAN. Single-channel open impeller. motralec. electrical submersible pumps. General characteristics

DGN. Set-back Vortex impeller. electrical submersible pumps. General characteristics

Multilift M, MD, MDV, and MD1 ranges

High pressure centrifugal pumps

TOP MULTI. Submersible multi-stage pumps TOP MULTI 1 TOP MULTI 2-3. PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 42 m

Data sheet: Wilo-VeroLine-IPL 100/ /4

Data sheet: Wilo-VeroLine-IPL 65/ /2

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

SPECIFICATION PUMP. DW - G 2 UNI ISO 228 Flange

Data sheet: Wilo-CronoLine-IL 65/130-4/2

Data sheet: Wilo-CronoLine-IL 50/200-1,5/4

Data sheet: Wilo-CronoLine-IL 50/120-2,2/2

Data sheet: Wilo-CronoLine-IL 80/145-1,1/4

High Pressure Centrifugal Pumps Product Overview

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET

50Hz. water solutions. E SerieS DGE DRE GRE APE

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART DW 204 PERFORMANCE CHART DW VOX 205

DGN. Set-back vortex impeller. submersible pumps PRODUCT CATALOGUE General characteristics

S range kw GRUNDFOS WASTEWATER

Submersible Mixer. Amamix. 60 Hz. Type Series Booklet

Data sheet: Wilo-CronoLine-IL 100/250-5,5/4

DGN. Set-back vortex impeller. electrical submersible pumps. General characteristics

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 BEARINGS 301 MECHANICAL SEAL 301

SUBMERSIBLE PUMPS EFFLUENT DISPOSAL RANGE 4 poles - 50 Hz

Data sheet: Wilo-CronoLine-IL 40/220-1,5/4

JUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)

GRUNDFOS DATA BOOKLET AP, KP. Wastwater pumps 50 Hz

GY/UY GRINDER / VORTEX SERIES

Introducing the new Steady Flygt 1300 series. Power to go

Data sheet: Wilo-CronoNorm-NL 150/315-37/4

Submersible Electric Pumps for Solid-laden Wastewater. DOMO Series

Electric submersible pumps SEMISOM for sewage water

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 TYPE KEY 202 PERFORMANCE CHART DW 203 PERFORMANCE CHART DW VOX 204

4SR. 4 submersible pumps. PERFORMANCE RANGE Flow rate up to 400 l/min (24 m³/h) Head up to 425 m

Data sheet: Wilo-VeroLine-IPL 65/ /2

NIVOMAG MAGNETIC LEVEL SWITCHES GENERAL DESCRIPTION MODEL SELECTION SUPPLEMENTARY DATA. Temperature diagram: Temperature specification for Ex versions

Data sheet: Wilo-CronoTwin-DL 65/250-4/4

Submersible Sewage Pumps Type ABS XFP

JUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS

Submersible Motor Pump. Amarex N. 60 Hz. Type Series Booklet

Corrosion Resistant Fiberglass Submersible Pumps. EU product Made in Italy

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

50 Hz. GLS - GLV Series SUBMERSIBLE WASTEWATER PUMPS. Cod Rev

GRUNDFOS WASTEWATER. Super-heavy-duty submersible sewage and raw water pumps

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage

Data sheet: Wilo-VeroTwin-DPL 65/ /2

JUNG PUMPEN compli 100 MC Sewage lifting stations

200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES DW VOX 204

Transcription:

Series description Wilo-Drain TP 80/TP 100 Equipment/function Thermal motor monitoring Leakage detection in the motor ATEX-certified Sheath current cooling Materials Pump housing: PUR Impeller: PUR Shaft: stainless steel 1.4404 Mechanical seal on pump side: SiC/SiC Mechanical seal on motor side: C/Cr Static gasket: NBR Motor housing: stainless steel 1.4404 Design Submersible sewage pump for industrial applications Type key e.g. Wilo-Drain TP 80 E 160/17 TP Submersible pump 80 Nominal diameter [mm] E Single-channel impeller 160 Nominal diameter of the impeller [mm] 17 Power P 2 [kw] (=value/10 = 1.7 kw) Application Pumping of wastewater and drainage water as well as sewage containing faeces, municipal and industrial sewage for: domestic and site drainage sewage and water management Environmental and water treatment technology Industrial and process engineering Special features/product benefits Operation in stationary wet well and dry well installation as well as portable wet well installation Submersible ATEX approval as standard Low weight Detachable connection cable Longitudinally watertight cable inlet Standard-equipped with clogging-free sheath current cooling Corrosion-resistant (e.g. swimming-pool water, salt water, etc.) Low-wearing Patented clogging-free hydraulics Easy installation due to suspension unit or pump base Technical data Mains connection: 3~400 V, 50 Hz Immersed and surfaced operating modes: or S3 25% Protection class: IP 68 Insulation class: F Max. fluid temperature: 3-40 C Free ball passage: 80 or 95 mm Max. immersion depth: 20 m Description/design Submersible sewage pump as submersible monobloc unit for stationary wet well and dry well installation as well as portable wet well installation. Hydraulics The outlet on the pressure side is designed as DN 80 or DN 100 horizontal flange connection. Single-channel impellers are used as the impeller shape. Motor Dry motors are equipped with clogging-free sheath current cooling as standard. This ensures that heat is given off directly to the fluid. As a result, these units can be operated in immersed and non-immersed state for permanent or intermittent operation. In addition, the motor is equipped with a leakage detection unit and a thermal motor monitoring unit. A sealing chamber protects the motor from fluid ingress. The filling fluid used is potentially biodegradable and environmentally safe. The cable inlet is longitudinally watertight, the standard cable length is 10 m. Sealing Sealing on the fluid side and on the pump side is achieved by two bidirectional mechanical seals. Scope of delivery Pump ready for connection with 10 m connection cable (bare cable end) Installation and operating instructions Accessories Suspension unit Chain Non-return valve and gate valve Various pressure outlets and hoses Switchgears and relays Options HD version with Viton seals and another mechanical seals Pumps without cooling jacket for use in higher-viscosity fluids such as sludge (intermittent operation S3-25 only) Salt water version for higher temperatures and salt contents Version for horizontal dry well installation External cooling for fluid with floating solid matter, such as wood chippings Cable lengths up to 50 m are available in length increments of 10 m 180 Wilo Building Services catalogue 50 Hz Drainage and sewage Edition 2011/2012 Subject to change without prior notice

Series description Wilo-Drain TP 80/TP 100 Duty chart H[m] 20 Wilo-Drain TP 80/TP 100 18 16 Dewatering 12 10 8 TP 80 TP 100 6 4 2 0 0 20 40 60 80 100 120 0 160 180 0 10 20 30 40 50 Q[m³/h] Q[l/s] Wilo Building Services catalogue 50 Hz Drainage and sewage Edition 2011/2012 Subject to change without prior notice 181

Pump curves, ordering information Wilo-Drain TP 80 Pump curves Wilo-Drain TP 80-50 Hz - 50 rpm Open single-channel impeller - Free ball passage: 80 mm H[m] 18 16 12 36% 38% 40% 42% 44% 46% 48% 50% 10 8 51% TP 80E230/40 TP 80E210/37 6 4 2 TP 80E170/21 TP 80E160/17 TP 80E190/29 0 0 20 40 60 80 100 0 4 8 12 16 20 24 28 Q[m³/h] Q[l/s] Pump curves in accordance with ISO 9906, Appendix A. The specified degrees of efficiency correspond to the overall efficiency. Information for order placements Wilo-Drain... Mains connection Art no. TP 80E160/17 3~400 V, 50 Hz K 6043950 TP 80E170/21 3~400 V, 50 Hz K 6043957 TP 80E190/29 3~400 V, 50 Hz K 6043963 TP 80E210/37 3~400 V, 50 Hz K 6043971 TP 80E230/40 3~400 V, 50 Hz K 6043983 = supply availability, L = stock article, C = order-specific production approx. 2 weeks, K = order-specific production approx. 4 weeks, A = delivery time on request 182 Wilo Building Services catalogue 50 Hz Drainage and sewage Edition 2011/2012 Subject to change without prior notice

Technical data Drain TP 80 TP 80E160/17 TP 80E170/21 TP 80E190/29 TP 80E210/37 TP 80E230/40 3~400 V, 50 Hz 3~400 V, 50 Hz 3~400 V, 50 Hz 3~400 V, 50 Hz 3~400 V, 50 Hz Unit Pressure connection DN 80 DN 80 DN 80 DN 80 DN 80 Free ball passage mm 80 80 80 80 80 Max. volume flow Q max / m 3 /h 75 85 100 100 95 Max. delivery head H max / m 9 10 13 15 17 Operating mode (immersed) Operating mode (non-immersed) Max. immersion depth m 20 20 20 20 20 Protection class IP 68 IP 68 IP 68 IP 68 IP 68 Fluid temperature T / C 3... 40 3... 40 3... 40 3... 40 3... 40 Weight approx. m / kg 42 42 42 42 42 Motor data Nominal current I N / A 6.4 6.7 7.3 8.5 9.5 Starting current I A / A Nominal motor power P 2 / kw 1.7 2.1 2.9 3.7 4 Power consumption P 1 / kw 2 2.5 3.3 4.5 5.1 Activation type Direct Direct Direct Direct Direct Nominal speed n / rpm 50 50 50 50 50 Insulation class F F F F F Recommended switching frequency 1/h 20 20 20 20 20 Max. switching frequency 1/h 60 60 60 60 60 Permitted voltage tolerance % /- 10 /- 10 /- 10 /- 10 /- 10 Cable Length of connecting cable m 10 10 10 10 10 Cable type NSSHÖU NSSHÖU NSSHÖU NSSHÖU NSSHÖU Cable cross-section mm 2 7x1,5 7x1,5 7x1,5 7x1,5 7x1,5 Type of connecting cable Detachable Detachable Detachable Detachable Detachable Mains plug Equipment/function Float switch Motor protection WSK WSK WSK WSK WSK Explosion protection ATEX ATEX ATEX ATEX ATEX Materials Static seal NBR NBR NBR NBR NBR Impeller PUR PUR PUR PUR PUR Sealing on motor side C/Cr C/Cr C/Cr C/Cr C/Cr Mechanical seal SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC Motor housing 1.4404 1.4404 1.4404 1.4404 1.4404 Pump housing PUR PUR PUR PUR PUR Pump shaft 1.4404 1.4404 1.4404 1.4404 1.4404 Dewatering P 1 refers to the maximum power consumption. All of the data applies to 3~400 V, 50 Hz and a density of 1 kg/dm 3. Wilo Building Services catalogue 50 Hz Drainage and sewage Edition 2011/2012 Subject to change without prior notice 183

Dimensions Wilo-Drain TP 80 Dimension drawing Wilo-Drain TP 80 - stationary wet well installation 90 60 ø650 700x1 325 6 81 228 19 160 15 40 DN 80 180 315 >80 2x Ø42,4x3,25 DIN 2440 220 81 228 105 170 170 52 428 615 (550-750) 180 303,4 Ø40 225 118,5 110 688 210,5 >85 ø1 Ø12 ø1500 80 Dimension drawing Wilo-Drain TP 80 - stationary dry well installation 0 370 494 130 180 180 342 130 184 Wilo Building Services catalogue 50 Hz Drainage and sewage Edition 2011/2012 Subject to change without prior notice