Operation Manual for the Drummond Pipet-Aid XP

Similar documents
Operation Manual for the Drummond Pipet-Aid XL

Operation Manual for the Drummond Pipet-Aid XL

Operation Manual for the Drummond Hood Mate Pipet-Aid

Pipette Controllers OPERATOR INSTRUCTIONS

Never charge the batteries with a charger other than that supplied by the manufacturer.

PRECISION LIQUID HANDLING SYSTEMS CUSTOM GLASS TUBING

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only.

60V RECHARGEABLE LITHIUM-ION BATTERY

ENGLISH. RS Stock number Description:

CappController Pipette Controller. Operation Manual Version: 1.2.

BlueSwan Pipette Controller

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Tempo PIPETTE CONTROLLER USER GUIDE. Masters of precision

9. WARRANTY INFORMATION

Tenergy Corp 1292 Kifer Road Suite 807 Sunnyvale CA 94086

CHARACTERISTICS FOR. NEXcell NICKEL-METAL HYDRIDE RECHARGEABLE BATTERY PACKS. MODEL HTD x 10

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

High Temperature Rechargeable Nickel-Metal Hydride Cylindrical Battery Pack, 3 cell, 4000mAh

Specification Approval Sheet

User s Manual. Pipette Controller for liquid handling. Thank you very much for purchasing Pipette Mate NEO.

Step1: Battery and Speaker Assembly Step 2: Pump and Battery Installation Step 3: Setting Up Your Fountain 6 Troubleshooting and Maintenance

Register your instrument! Easypet 3. Operating manual

Cordless Screwdriver

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

RS Stock No

Bibbyjet Pipette Controller. Fingertip control... technology & ergonomics in harmony

USER S GUIDE 2880 SERIES. 3 Safety Instructions. Product View. Assembly 4-5. Operation. Maintenance and Care. Troubleshooting.

USER'S GUIDE 9151 SERIES V

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1

V3700UK OWNER S GUIDE.

ENGLISH. RS Stock No

OPERATING INSTRUCTIONS

OPERATOR'S MANUAL Model CHL91302 Battery Charger for use with LITHIUM EARTHWISE Lithium-ion Battery Pack

Register your instrument! Easypet 3. Operating manual

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

Cordless High Speed Drill

RECHARGEABLE POWER OUTAGE LED LIGHT INSTRUCTION MANUAL

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

Twelve Unit Rapid Charger

Rechargeable Garden Fountain

82V LITHIUM-ION BATTERY CHARGER GC 400

Cordless two speed drill/driver K 10613

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

Intelligent Battery Charger

User s Manual Power Supply IM E. 5th Edition

TECHNOLOGY FILE GB CELL. FILE NAME:Specification for 18650C4 Cylindrical. Lithium Ion Rechargeable Battery PREPARED BY REVIEWED BY APPROVED BY

CAUTION-ELECTRICALLY OPERATED PRODUCT:

NI-MH BATTERIES SPECIFICATIONS

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser!

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

4V LITHIUM-ION SCREWDRIVER OWNER S OPERATING MANUAL

Checkup. Make. Signature. Date. Company Stamp: com

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Battery Safety Instructions 4 Garden Fountain Parts List 7 Step1: Battery Installation 8 Step 2: Setting Up Your Fountain 11

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

MULTI-FUNCTION JUMP STARTER

2800 OPERATING INSTRUCTIONS

OPK-300N OPTIMAX Multi-Lite

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

LIQUID HANDLING TECHNOLOGY. User Manual Bedienungsanleitung

Specification Approval Sheet

Single Unit Rapid Charger FOR RECHARGEABLE TWO-WAY RADIO BATTERIES

Technical Specification

Register your instrument! Easypet 3. Operating manual

CYCLONE X Bolt PP-600 Power Pack for Portable Flashes

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

ELECTRIC WAGON OWNER S MANUAL. Read and understand this entire manual before allowing child to use this product! Item Numbers:

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

2 1.Nominal Voltage 1.2V. 2 6.End Voltage of Discharge 1.0V

INSTRUCTIONS. Living Room. Bathroom. Windows

Operating Instructions. PowerMax. CORDLESS CAULKING GUN Modell: HPS-4C2-10.8V Li-Ion 380ml to 410ml (5:1)Coaxial Cartridges

2.0Ah BATTERY INSTRUCTION MANUAL

Cordless Blower. 18 Volt OZCBL18VA. To view the full range visit: Operation Manual 2 Year Replacement Warranty

BC-0907 SBC3001. Solar Charger

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

Battery Powered Hydraulic Pump; Kit PN [ ]

12.0-Volt Lithium-Ion Power Source

Intelligent NiMH/NiCd/Li-ion Charger TN456

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

Data Sheet. Specifications of Nickel Metal Hydride Battery. Page 1 of 6. Conrad Electronic SE, Klaus-Conrad-Str. 1, D Hirschau. Item no.

SURGICAL POWER & ACCESSORIES. Rx Only PM-X00-710/PM-X IR-12.13

User Manual PORTABLE JUMPSTARTER

original instructions 18V Torch RFP1801

INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY. Safety

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

19.2V CORDLESS 2-IN-I COMBO KIT OWNER'S MANUAL

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Mini Multimeter with Non-Contact Voltage Detector (NCV)

V2700Z OWNER S GUIDE.

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

1. D-Lux Introduction ENGLISH Parts & Components Product Overview. 4. Precautions. 5. Hand-piece Components Installation

Lumitester PD-20 Control Kit

OPERATING INSTRUCTIONS

190M. Medical ScopeMeter. Safety Information

Transcription:

Operation Manual for the Drummond Pipet-Aid XP Catalog Number 4-000-101 4-000-201 4-000-201-E Quality and Reliability Guaranteed Made in USA by Drummond Scientific Co. 500 Parkway Broomall, PA 19008 800/523-7480 610/353-0200 www.pipet-aid.com

Operating Instructions for the Drummond Statement of Purpose All Pipet-Aid models are designed to transfer liquids with the use of serological, volumetric and/or blow-out pipets in either glass, plastic or something similar. Rules for Safe Operation For indoor use only. Do not attempt to use the charger with any other product. DO NOT ATTEMPT TO CHARGE THIS UNIT WITH ANY OTHER CHARGERS. This product includes rechargeable Ni-MH batteries. Do not incinerate batteries as they may explode at high temperatures. Never operate unit in an explosive atmosphere. Expelling liquid from a pipet generates aerosols. The faster the liquid is expelled, the more aerosols are generated. Understand the nature of the liquid being pipetted and take appropriate precautions. Do not operate unit with a damaged cord. Use charger only in a standard electrical outlet. Do not handle charger with wet hands. Do not put unit or charger in water or other liquid. Pipetting acids or strong alkalis will damage unit. When servicing, use only identical Drummond replacement parts. Save these instructions. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Always use the charger or power supply that is supplied with the unit. Connections to Charger: Check the charger to see that the line voltage corresponds to the voltage indicated on the mains adapter. If the mains adapter supply and the line voltage are not compatible, the electrical components of the Pipet-Aid may be damaged or destroyed. Before each use, confirm that the mains adapter cable is not damaged, worn or severely buckled and there are no breaks in the insulating surface. If any damage is noted, do not use the Pipet-Aid until the damaged mains is replaced. Specifications for Usage This equipment is for indoor use only. Temperature Range 10 C 35 C, Maximum Humidity 60% For use with pipets from 1 ml to 100 ml FAILURE TO USE THE EQUIPMENT IN ACCORDANCE WITH INSTRUCTIONS OR MODIFYING THE EQUIPMENT WILL VOID WARRANTIES. CAUTION: CAREFULLY READ THROUGH THIS ENTIRE MANUAL BEFORE USING YOUR NEW PIPET-AID XP. PAY CLOSE ATTENTION TO THE RULES FOR SAFE OPERATION WARNINGS AND CAUTIONS. 2

Pipet-Aid (Model XP) Features Thank you for purchasing the Drummond Model XP Portable Pipet-Aid which incorporates several important features: A powerful pump designed specifically for Pipet-Aid use. Compact, lightweight design. Individual speed controls for both the aspirate and the dispense buttons. Designed and constructed with material that will withstand commonly used reagents. Nosepiece lock to prevent accidental removal. External battery access. The Drummond Pipet-Aid XP is covered under the following US Patents, and other foreign patents pending. #5,294,405, #5,214,968, #5,616,871 Instructions for Use Insert a pipet into the nosepiece by twisting the pipet while pushing. Exercise extreme caution when using glass pipets as breakage is an ever-present danger. Depressing the top button fills the pipet, depressing the bottom empties it. The flow rate is proportional to the amount the button is depressed. Speed Controls Each button has three speeds F fast, M medium, S slow. The speed is selected by rotating the button on its axis until the speed chosen is visible when the handle is held in the right hand. The M corresponds to the speed of previous Pipet-Aids. Fast is to be used for rapid filling of large pipets or breaking up cell clumps. Slow speed should be used for small pipets or where precise delivery is required. Please note that each button can be set independently. For example, one could fill a large pipet on F and deliver small amounts on S. CAUTION: SPEED Control Buttons must be positioned on F, M, or S. Intermediate settings will cause leakage. Also do not change Speed Control Buttons with fluid in the pipet. This will cause the unit to leak. Battery The XP is powered by a nickel-metal hydride rechargeable battery. To get the maximum life from the battery, recharge it overnight as needed. The battery can be replaced by removing the screw marked (B) on the diagram and sliding out the cover (78). Filter The XP incorporates a TISSUE CULTURE NOSEPIECE, which features a unique filter element. The TC filter will cease to pass air in either direction when it becomes wet, alerting the user to possible contamination of the rubber insert. To remove the filter, slide the nosepiece release (74) away from the nosepiece and twist off the nosepiece. 3

Instructions for Cleaning Wiping the unit with a soft cloth or wipe with isopropyl alcohol is sufficient to clean the unit. Avoid the use of acetone and other organic solvents which will damage the handle. All components inside the nosepiece may be autoclaved with the exception of the Drummond Self-locking Filter. Replace the filter when compromised. Always disconnect the charger from the unit when cleaning. Battery The XP is powered by a 8.4V, nickel-metal hydride (Ni-MH), rechargeable battery (catalog number: 4-000-035). The battery can be replaced by removing the screw marked (B) on the diagram on page 7 and sliding off the cover (78). Charging the Battery IMPORTANT: BATTERY SHOULD BE CHARGED FOR A MINIMUM OF SIX HOURS BEFORE INITIAL USE. When not in use, plug in the charger and let charge overnight. NOTE: DO NOT USE ANY CHARGER OTHER THAN THE ONE SUPPLIED. ALTHOUGH MANY OTHER CHARGERS WILL FIT INTO THE UNIT, CHARGING WILL NOT OCCUR AND DAMAGE TO THE BATTERY CAN RESULT. All rechargeable batteries have a limited life span. Generally each battery will last approximately 1000 cycles (charges) and then must be replaced. Replacement is a user function and will require a Phillips head screwdriver, a new battery (4-000-035), and about two minutes of your time. (See above) *Use only recommended battery for replacement (DSC #4-000-035). Do not replace the battery with a non-rechargeable battery. Explosion or fire hazard can occur if incorrect battery replacement is used. 4

Questions, Comments, Suggestions, or Service: CALL OUR HOTLINE AT 1-800-523-7480 ASPIRATE NOSE- PIECE RELEASE DISPENSE Ordering Information Catalog No. Description 4-000-101 Pipet-Aid XP 110V 4-000-030 Charger, Input: 120V, 60Hz 4-000-201 Pipet-Aid XP 230V, Euro Plug, CE 4-000-031 European Charger, Input: 230V, 50Hz 4-000-201-E Pipet-Aid XP 240V, UK, CE 4-000-033 UK Charger, Input: 240V, 50Hz CHARGING PORT Specifications Size 5.5 Weight 7.5 oz. Capacity Accepts 1 to 100 ml pipets Battery Ni-MH (8.4V/750 mah) 5

Parts Commonly used parts (e.g. rubber inserts, batteries) are available from your dealer or Drummond Scientific Company. We welcome your comments, questions or suggestions. 75 74 73 73 73 73 57 51 57 77 72 02 40 79 6

35 90 78 B 76 77 Index Numbers Correspond to Last Digits in Catalog Number Catalog No. Parts Description 4-000-002 Rubber Insert 2/pack 4-000-030* Pipet-Aid charger 110V 4-000-031* Pipet-Aid charger 230V 4-000-035 Ni-MH Rechargeable Battery 4-000-040 Portable Motor & Pump 4-000-051 Replacement Filters 5/pack 4-000-051-S Sterile Filters 5/pack 4-000-052 Replacement Filters 50/pack 4-000-052-S Sterile Filters 50/Pack 4-000-057 TC Filter Gasket 2/pack 4-000-072 Switch Operator *Charger not shown **Wall Bracket not shown Catalog No. Parts Description 4-000-073 Valve Body Assembly (Complete with Buttons) 4-000-074 Nosepiece Release 4-000-075 Handle Connector 4-000-076 Wire Harness with Switch and Terminals 4-000-077 Handle Shell 4-000-078 Battery Door 4-000-079 EZ Grip Nosepiece 4-000-089** Pipet-Aid Holster-Type Wall Bracket 4-000-090 Removable Stand 7

Maintenance and Servicing Keep your Pipet-Aid clean and charged at all times. When not in use, it is appropriate to keep the unit plugged into the charger. No damage will occur if you are using the charger supplied. Drummond Self-locking Filters are provided with all models that use filters. Replacement part numbers are: 4-000-051 5 pk 4-000-051-S 5 pk, sterile 4-000-052 50 pk 4-000-052-S 50 pk, sterile These filters must be replaced if over-pipetting occurs. They protect the handle components as well as minimize cross contamination of samples and contain two membrane layers. All rechargeable batteries have a limited life span; generally each battery will last 1,000 cycles (charges) and then must be replaced. Battery replacement is a user function and will not require any special tools; a Phillips screwdriver is all you will need. Voltage Rating and Frequency: Chargers 4-000-101 4-000-030 (charger) 120V, 60Hz, 55mA 6VDC/10mA 4-000-201 4-000-031 (charger) 230V, 50Hz, 55mA, CE, Int l 8.7V/8mA 4-000-201-E 4-000-033 (charger) 240V, 50Hz, 55mA, CE, UK 8.7V/10mA Battery Specifications Pipet-Aid XP Cat. No. Rating 4-000-035 8.4V/750mA Ni-MH 500 Parkway, Box 700 Broomall, PA 19008 800/523-7480 FAX: 610/353-6204 Website: www.drummondsci.com For Technical Assistance, call 1-800-523-7480 or e-mail info@drummondsci.com Copyright, Drummond Scientific Company, 2014, Rev. 3/14 Printed in USA Pipet-Aid is a registered trademark of Drummond Scientific Company