Bladder-type accumulator. Type HAB. Features. Contents. RE Edition: Replaces: 50170

Similar documents
Bladder-type accumulator HAB

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Bladder-type accumulators

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Supply pressure compensator, direct operated

Throttle and throttle check valve

Pressure reducing valve, direct operated

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated

Motor-pump group. Features. Table of contents RE 51171/ Type ABAPG and ABHPG

Check valve. Type S. Contents. Features. RE Edition: Replaces:

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Axial Piston Fixed Pump A2FO

Hydraulic inch power brake valve LT 31

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Bladder-type accumulator

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Pressure reducing valve, direct operated, with pressure monitoring

Inline filter with filter element according to DIN 24550

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Pressure reducing valve, direct operated

Proportional pressure reducing valve, pilot operated

Pressure relief valve, pilot operated

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

2-way flow control valve

Twin throttle check valve

Check valve, pilot operated

3/2 directional spool valve, direct operated with solenoid actuation

Inline filter with filter element according to DIN 24550

2-way flow control valve

Filling valve sandwich plate

Pressure relief valve, pilot operated

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Inline filter with filter element according to DIN 24550

Flow sharing control block in mono block / sandwich plate design M6-22

Check valve, pilot operated

Block mounting filter, for lateral flange-mounting

Check valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Block mounting filter, for lateral flange-mounting

Block mounting filter, for vertical flange-mounting

Check valve, pilot operated

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Block mounting filter, for sandwich plate mounting

3/2 and 4/2 directional seat valves with solenoid actuation

Line filter with filter element according to DIN 24550

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Flow sharing control block in mono block / sandwich plate design M6-15

Block mounting filter, lateral flange-mounting possible

Check valve, pilot operated

Directional servo-valve of 4-way design

Pressure limitation and feed valve, pilot-operated Type MHDBN...Y

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition:

Axial piston fixed motor A2FM Series 70 A2FE Series 70

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Pressure relief valve, pilot operated

Hydro-electric pressure switch

Throttle and throttle check valve

Single-circuit power brake valve LT 05

Gerotor pump, fixed displacement volume

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

2/2 directional seat valve, direct operated with solenoid actuation

Pressure relief and feed valve, pilot operated. Type MHDBN. Features. Contents. RE Edition: Replaces:

Pipe burst safety valve

Radial piston motor for compact drives MCR-C

8050/18-V1-02 SEALING PLUG. Efficient sealing of holes

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Central Hydraulics Valve for Tractors with Priority Function for Steering, Trailer Brake and Pilot Oil Valve

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Radial piston motor for frame integrated drives MCR-A

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

Pressure sequence valve, direct operated

Dual-circuit power brake valve LT 07

Bourdon tube pressure switch with infinitely variable switching pressure differential

Bourdon tube pressure switch with infinitely variable switching pressure differential

Proportional pressure reducing valve, pilot operated

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Pressure relief valve, pilot operated

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

Radial piston pump PR4 series 1X

Type 400LDN0040 to 1000; 400LD0130, 0150

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Replacement cartridge filter

Throttle and throttle check valve

External gear motor High Performance AZMB

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Axial Piston Fixed Pump A17FNO Series 10

Transcription:

Bladder-type accumulator Type HAB RE 0171 Edition: 16-03 Replaces: 0170 Component series 6X Nominal volume 1... 0 liters Maimum operating pressure 30 bar Features Hydraulic accumulator according to Pressure Equipment Directive 1/68/EU Bladder material for different applications Use: Energy storage in intermittent operation systems Energy reserve for emergencies Compensation of leakage loss Impact and vibration absorption Volume compensation in case of pressure and temperature change Contents Features 1 Ordering code 2 Function, section 3 Technical data Application, mode of operation Calculation 8 Dimensions 9 Spare parts and accessories 17 Important notices 18 Safety equipment 18 Further information 19 RE 0171, edition: 16-03, Bosch Reroth AG

2/ HAB Bladder-type accumulator Ordering code 01 02 03 0 0 06 07 08 09 11 12 13 1 HAB 6X / 0 G 2 1 1 1 01 Bladder-type accumulator HAB Nominal volume 02 1 liter 1 2. liters 2. liters 6 liters 6 liters liters 2 liters 2 32 liters 32 0 liters 0 Maimum operating pressure 03 30 bar (1... 6 liters) 30 330 bar (1... 0 liters) 330 0 Component series 60 69 (60 69: unchanged installation and connection dimensions) 6X Gas filling pressure 0 0 bar 0 Port size for hydraulic fluid 1) 06 "1" "2." "" "6" "" "" "2" "32" "0" G3/ G0 G1 1/ G07 G2 G09 Type of mounting (oil port form) 07 Thread with sealing surface, radial on the inside G Gas port form 08 Gas valve for filling and test device (see page 12) 2 Bladder material 1) 09 NBR N ECO E FKM F HNBR H Tank material 1) Steel 1 Surface of the tank inside 1) 11 Steel 1 Surface of the connection side 1) 12 Steel 1 Certification (acceptance) 13 CE (PED 1/68/EU) CE Instructions for use BA 16 Further details in the plain tet, e.g. special versions * Order eample: HAB-330-6X/0G09G-2N111-CE 1) Other versions upon request. Bosch Reroth AG, RE 0171, edition: 16-03

Bladder-type accumulator HAB 3/ Function, section General Hydraulic accumulators are hydrostatic devices capable of storing a certain amount of energy in order to release it to the hydraulic system when needed. Fluids only possess low compressibility; however, gases are highly compressible. The working principle of all gasloaded hydraulic accumulators is based on this difference. The difference between bladder and diaphragm type accumulators lies in the type of separator element. Hydraulic accumulators essentially consist of a fluid section and a gas section with a gastight separator element. The fluid section has a connection to the hydraulic circuit. If a higher liquid pressure is applied to a specific quantity of pressurized gas, the gas volume decreases as the liquid pressure increases, with the gas pressure increasing with the liquid pressure. If the pressure of the fluid decreases, the fluid is pushed back into the hydraulic system by the epanding gas until the pressure is balanced again. Bladder-type accumulator Bladder-type accumulators consist of a seamless cylindrical pressure container (1) made of high-strength steel. An elastic bladder (2) mounted inside the container separates the accumulator into a gas side and a fluid side. Via the gas valve (), the bladder is filled with nitrogen up to the intended gas filling pressure p 0. The oil valve (3) located inside the oil port of the bladdertype accumulator closes if the pressure on the gas side is higher compared to the fluid side. This prevents the bladder from entering the oil channel and being destroyed. When the minimum operating pressure is reached, a small fluid volume (appro. % of the hydraulic accumulator's nominal volume) should remain between the bladder and the oil valve in order to prevent the bladder from hitting the valve during each epansion process. The gas valve () consists of sealing cap (.1), gas valve insert (.2), gas prefill valve body (.3), and O-ring (.). These parts can be replaced individually. The type cap (7) includes the technical data and features of the hydraulic accumulator. Symbol 6 Detail X.1 8 7 1 2 3 9.2.3. 1 Tank 2 Bladder 3 Oil valve Gas valve Gas valve support 6 Nut 7 Type cap 8 Cover cap 9 Protective cap of oil valve RE 0171, edition: 16-03, Bosch Reroth AG

/ HAB Bladder-type accumulator Technical data (For applications outside these parameters, please consult us!) General Weight See table on page Design Bladder-type accumulator Installation position Bottom fluid connection socket, others upon request Type of mounting With clamping collars and console Line connection Screw-in thread Hydraulic Nominal volume V nom l 1 2. 6 2 32 0 Effective gas volume V eff l 2. 3.7.9 9.2 18.1 2. 33. 8.7 Maimum flow q ma l/min 20 0 0 0 900 900 900 900 900 Maimum operating pressure p ma bar 330 330 330 330 330 330 330 330 330 30 30 30 30 Maimum pressure fluctuation range Δp dyn bar 0 0 0 0 12 12 12 12 12 Operating pressures and useful volume See calculation on page... 8 Hydraulic fluid Hydraulic oil according to DIN 12; other fluids on request! Hydraulic fluid temperature range (others upon request) C 1... +80 (NBR) 32... +80 (ECO)... +80 (FKM) 30... +80 (HNBR) Pneumatic Charging gas Nitrogen, cleanliness class.0, N 2 = 99.99 vol. % Gas filling pressure p 0 bar 0 Hydraulic fluids Material Mineral oils NBR 1) ECO 2) HNBR 3) HFC NBR 1) HFD FKM ) 1) Acrylonitrile butadiene rubber 2) Epichlorohydrin rubber 3) Hydrated acrylonitrile butadiene rubber ) Fluorine rubber Bosch Reroth AG, RE 0171, edition: 16-03

Bladder-type accumulator HAB / Application, mode of operation Applications Various applications eist for hydro-pneumatic accumulators: Energy storage in order to save pump drive power in intermittent operation systems. Energy reserve for emergencies, e.g. upon failure of the hydraulic pump. Compensation of leakage losses. Impact and vibration absorption in case of periodic vibrations. Volume compensation in case of pressure and temperature changes. Mode of operation Fluids are almost incompressible and therefore cannot store pressure energy. Hydro-pneumatic Reroth accumulators use the compressibility of a gas for fluid storage. Eclusively use nitrogen of cleanliness class.0! N 2 = 99.99 vol. % load load V 0 V 1 V 2 p 0 p 1 p 2 unload unload Calculation Pressures The following pressures are of decisive importance for the calculation of an accumulator: p 0 Gas filling pressure at room temperature and empty fluid chamber p 0 (t) Gas filling pressure at operating temperature p 0 (t ma ) Gas filling pressure at maimum operating temperature p 1 Minimum operating pressure Maimum operating pressure p 2 In order to achieve the best utilization of the accumulator volume possible as well as a long life cycle, compliance with the following values is recommended: p 0 (t ma ) ~ 0.9 p 1 (1) The highest hydraulic pressure should not eceed four times the filling pressure, as otherwise too much stress will be put on the elasticity of the bladder, resulting in too great a compression change with strong gas heating: p 2 p 0 (2) The life cycle of the accumulator bladder is the higher the smaller the difference between p 1 and p 2 is. However, the operating ratio of the maimum accumulator capacity will also be reduced accordingly. RE 0171, edition: 16-03, Bosch Reroth AG

6/ HAB Bladder-type accumulator Calculation Oil volume According to the pressures p 0 p 2, the gas volumes V 0 V 2 will result. In this process, V 0 simultaneously is the nominal volume of the accumulator. The available oil volume ΔV corresponds to the difference of the gas volumes V 1 and V 2 : ΔV V 1 V 2 (3) Application of calculation diagrams (see page 7 8) Available oil volume V V [l] V 2 p 0 Gas filling pressure s 2 The gas volume variable within a pressure differential is determined by the following equations: For an isothermal state change of gases, i.e. when the change of the gas cushion happens so slowly as to leave sufficient time for a complete thermal echange between the nitrogen and its environment, therefore keeping the temperature constant, the following applies: p 0 V 0 = p 1 V 1 = p 2 V 2 (.1) s V 1 1 p p [bar] p 1 p 2 Operating pressure range Isothermal ΔV real = ΔV ideal K i p 2 = 0 bar For an adiabatic state change, i.e. a quick change of the gas cushion accompanied by a temperature change of the nitrogen, the following applies: p 0 V χ 0 = p 1 V χ 1 = p 2 V χ 2 (.2) Ki 0.9 0.8 p 2 = 300 bar p2 = 00 bar χ = ratio of the specific gas heats (adiabatic eponent), for nitrogen = 1. In practice, state changes rather follow adiabatic laws. Often charging is isothermal and discharge is adiabatic. Considering the equations (1) and (2), ΔV is between 0% and 70% of the nominal accumulator volume. The following applies as a guiding principle: V 0 = 1. 3 ΔV () 0.7 0.6 0.1 0.2 0.3 0. 0. 0.6 0.7 0.8 0.9 p 1 /p 2 Calculation diagram For graphic determination, the formulas (.1) and (.2) are converted into diagrams on pages 7 and 8. Depending on the task, the available oil volume, the accumulator size or the pressures can be determined. Adiabatic ΔV real = ΔV ideal K a 0.9 Correction factor K i and K a The equations (.1) and (.2) apply to ideal gases only. The behavior of real gases, however, will show considerable variation at operating pressures above 0 bar which will have to be accounted for by correction factors. These can be taken from the following diagrams. The correction factors the ideal sampling volume V is to be multiplied with lie within a range of 0.6 1. Ka 0.8 0.7 p 2 = 0 bar p2 = 300 bar 0.6 0.1 0.2 0.3 0. 0. 0.6 0.7 0.8 0.9 p 1 /p 2 Bosch Reroth AG, RE 0171, edition: 16-03

Bladder-type accumulator HAB 7/ Calculation: isothermal state changes p 0 = 1 90 bar 1.0.0 0.8 V [l] 3 30 2 2 1 16 12 1.0 8.0 7.0 6.0.0.0.0 3.0 2. 1. 1. 0.7 0.6 0. 0. p 0 [bar] 1 2 3 6 7 89 12 1 16 18 2 30 0 0 60 70 80 90 1 8 6.0 3.0 0.3.0 0. 0. 0.2 0.1 0 32 2 6 2. 1 1 2 3 30 0 0 0 0 00 Accumulator size [l] p 1, p 2 [bar] 300 p 0 = 0 300 bar 1.0.0 0.8 3 30 2 16 1.0 7.0 6.0.0 2. 1. 0.7 0.6 V [l] 2 1 1 12 8 8.0 6.0.0.0.0 3.0 3.0 1. 0. 0. 0. 0. 0.3 0.2 0.1 p 0 [bar] 0 10 0 20 300 0 32 2 6 2. 1 0 10 0 20 300 00 Accumulator size [l] p 1, p 2 [bar] RE 0171, edition: 16-03, Bosch Reroth AG

8/ HAB Bladder-type accumulator Calculation: Isothermal state changes p 0 = 1 90 bar 1.0.0 0.8 V [l] 3 30 2 1 2 1 16 12 8 1.0 8.0 6.0 7.0 6.0.0.0 3.0.0 3.0 2. 1. 1. 0.7 0.6 0. 0. 0.3 p 0 [bar] 1 2 3 6 78 9 12 1 16 18 2 30 0 0 60 70 80 90.0 0. 0. 0.2 0.1 0 32 2 6 2. 1 1 2 3 30 0 0 0 0 00 300 Accumulator size [l] p 1, p 2 [bar] p 0 = 0 300 bar 1.0.0 0.8 3 30 2 16 1.0 7.0 6.0.0 2. 1. 0.7 0.6 V [l] 2 1 1 12 8 8.0 6.0.0.0.0 3.0 3.0 1. 0. 0. 0. 0. 0.3 0.2 0.1 p 0 [bar] 0 10 0 20 300 0 32 2 6 2. 1 0 10 0 20 300 00 Accumulator size [l] p 1, p 2 [bar] Bosch Reroth AG, RE 0171, edition: 16-03

Bladder-type accumulator HAB 9/ Dimensions (dimensions in mm) Preferred types HAB-6X Type Material no. h a b ød SW HAB1-30-6X/0G0G-2N111-BA HAB2,-30-6X/0G07G-2N111-CE HAB-30-6X/0G07G-2N111-CE HAB6-30-6X/0G07G-2N111-CE HAB-330-6X/0G09G-2N111-CE HAB-330-6X/0G09G-2N111-CE HAB2-330-6X/0G09G-2N111-CE HAB32-330-6X/0G09G-2N111-CE HAB0-330-6X/0G09G-2N111-CE R9013300 R9013301 R9013302 R9013303 R901330 R901330 R9013306 R9013307 R9013308 øg øe øf Nominal volume [l] Ordering code / type h Ød a b Øe Øf Øg SW Weight [kg] 1 HAB1-330-6X/...G0G... HAB1-30-6X/...G0G... 3.-3. 112.-11. 6±3 71.±3 G 3 / " 2. 23H7 0 7 2. HAB2.-330-6X/...G07G... HAB2.-30-6X/...G07G....-62. 112.-11. 6±3 71.±3 G1 1 / " 2. 36H8 0 HAB-330-6X/...G07G... HAB-30-6X/...G07G... 00.-2. 166.3-169.7 6±3 71.±3 G1 1 / " 2. 36H8 0 16. 6 HAB6-330-6X/...G07G... HAB6-30-6X/...G07G... 3.-69. 166.3-169.7 6±3 71.±3 G1 1 / " 2. 36H8 0 HAB-330-6X/...G09G... 9-91 216.8-221.2 1.±3 71.±3 G2" 76 H7 70 32 HAB-330-6X/...G09G... 869-901 216.8-221.2 1.±3 71.±3 G2" 76 H7 70 3 2 HAB2-330-6X/...G09G... 0-36 216.8-221.2 1.±3 71.±3 G2" 76 H7 70 61 32 HAB32-330-6X/...G09G... 1389-121 216.8-221.2 1.±3 71.±3 G2" 76 H7 70 8 0 HAB0-330-6X/...G09G... 190-1936 216.8-221.2 1.±3 71.±3 G2" 76 H7 70 123 RE 0171, edition: 16-03, Bosch Reroth AG

/ HAB Bladder-type accumulator Spare parts and accessories (dimensions in mm) HAB mounting elements 1 Clamp types Material number Accumulator size 1 2. 6 2 3 0 Clamp 1-1 131316021 1 Clamp 160-170 131316022 2 Clamp 218-228 131316026 1 2 Clamp 22-230 13131600 2 Console 13133008 1 1 1 Rubber support ring 130222 1 1 1 3 1 Clamp 2 Console 3 Rubber support ring 2 Console and rubber support ring Console (material number: 13133008) Rubber support ring (material number: 130222) 3000 Nm 7 0 3 ø1 0 260 123 ø170 22 Bosch Reroth AG, RE 0171, edition: 16-03

E 9 E S S H H C C M Bladder-type accumulator HAB 11/ Spare parts and accessories: Mounting clamps (dimensions in mm) Type F1 Type F2 D M F ry F a F r D A A K L B L B 9 Clamp types Dimensions A B C D E H K L M S Material number Clamp 1-1 F1 13 96 10 1-1 0 6-69 6 M8 3 131316021 Clamp 160-170 F1 237 17 0 160-170 0 90-9 3 M8 131316022 Clamp 218-228 F1 237 17 28 218-228 0 1-12 3 M8 131316026 Clamp 22-230 F2 2 212 2 22-230 30 1-123 29 M12 3 13131600 RE 0171, edition: 16-03, Bosch Reroth AG

12/ HAB Bladder-type accumulator Spare parts and accessories: filling and test device (dimensions in mm) Supplemental parts Material number (separate order) Pressure gauge 0... 2 bar R9000339 Pressure gauge 0... 60 bar 1372302 Pressure gauge 137230 0 00 bar Transition socket F 13339 GB 1333911 USA 1333912 Measurement case Material number for bladder-type accumulator (HAB) 0383011 Case (without contents) R9079781 Filling and test valve HAB 038300 Pressure gauge 0 to 20 bar 1372301 Hose l = 2. m 1307 D with transition socket for bladder and diaphragm accumulator 038301 (HAB/HAD) Components as above plus filling and test 0383006 valve HAD Hose l = m with transition socket KR J RUS D 1333913 133391 133391 13076 Dimensions of filling and test valve 1 valve body with check valve, drain valve, pressure gauge connection and gas hose connection. D 1 2 W 2.32 1 1/ in 0 10 113 M1 1. SW32 0 00 00 100 psi bar 00 200 3000 300 0 1372301 20 Reroth 0 3 l = 2. m SW32 Ø0 SAE 7/8 in -1 UNF 1 Spare part, material number 13706 2 Adapter see pages 1/1 Bosch Reroth AG, RE 0171, edition: 16-03

Bladder-type accumulator HAB 13/ Spare parts and accessories: adapter for nitrogen bottle to cap nut (dimensions in mm) Material number: 13339 Material number: 1333913 Material number: R90003782 W 21.8 1/1 in 37 SW32 W 2.32 1/1 in W 23 1/1 in 2 SW32 W 2.32 1/1 in M22 1.7 60 SW32 W2.32 1/1 in Material number: 1333911 Material number: R900216133 Material number: R9007088 G /8-ISO 228 SW32 W 2.32 1/1 in 81 68 W 22 1/1 in SW32 W 2.32 1/1 in W21.8 1/1 in 79 SW32 W2.32 1/1 in Material number: 1333912 Material number: 133391 Material number: R9070776 W 2.1 1/1 in 81 SW32 W 2.32 1/1 in G 3/-ISO 228 SW36 W 2.32 1/1 in G/8-ISO228 61 SW32 W 2.32 1/1 in RE 0171, edition: 16-03, Bosch Reroth AG

1/ HAB Bladder-type accumulator Spare parts and accessories: adapter for nitrogen bottle to cap nut (dimensions in mm) Country Brazil Bulgaria China France Greece United Kingdom India Italy Japan Canada North Korea South Korea Malaysia Meico Romania Russia Spain Saudi Arabia Singapore Taiwan Turkey USA Material number 13339 1333911 1333912 1333913 R900216133 133391 R90003782 R9007088 R9070776 Other countries upon request Spare parts and accessories: accumulator adapter for accumulator shut-off blocks type ABZSS (dimensions in mm [inches]) Please select the matching type according to data sheet 0131. 19 [0.7] 2, [0.] O1 D M ØD2 S H2 H1 O Accumulator shut-off block ABZSS 08 ABZSS ABZSS 28 [1.] Accumulator type Bladder-type accumulator Data sheet 0171 33 2 1); 1. 2) Accumulator DN 2..0 6.0.0.0 3.0 0.0 29.7 2.8 1); 2 2) Accumulator adapter S 1) S 2) S12 1) S7 2) S13 1) S9 2) D G3/A G1 1/A G2A H1 H2 M O O1 S 1. [0.61] 18 2. [0.71 0.] 37 [1.6] 3 [1.69] 16. [0.6] 1) 303 17. [0.68] 2) [1.18 0.12]. [0.81] 1) 8 3 18. [0.73] 2) [1.89 0.12] ØD2 39.9 [1.7] 1) 3.0 [1.37] 2) SW1 [1.61A/F] 1) SW36 [1.1A/F] 2) SW6 [1.81A/F] SW6 [2.A/F] Bosch Reroth AG, RE 0171, edition: 16-03

Bladder-type accumulator HAB 1/ Spare parts and accessories: accumulator adapter for accumulator shut-off blocks type ABZSS (dimensions in mm) Adapter to metric thread (HAB.. 1X to HAB.. X and 6X) D2 ød R2 L2 H SW D1 ød3 Nominal volume [l] According to ISO 228 According to ISO 228 Dimensions [mm] Material number adapter Order number complete with seal ring R2 D2 M A [Nm] D1 M A [Nm] H L2 ØD3 ØD SW 1 G3/ 180 +18 M30 1. 180 +18 32 28 6 12 1 133307 R90122863 2. 6 G1/1 0 + M0 1. 00 +0 3 37 60 133308 R9012286 0 G2 00 +0 M0 1. 0 + 1 78 32 70 133309 R9012286 Adapter for reduction of pipe connection ød2 D R2 H L2 SW D1 ød3 Nominal volume [l] According to ISO 228 According to ISO 228 Dimensions [mm] Material number adapter Order number complete with seal ring R2 D2 M A [Nm] D1 M A [Nm] H L2 ØD3 ØD SW 1 G3/ 180 +18 G3/8 70 +7 8 28 38 12 32 1333039 R90122880 2. 6 G1/1 0 + G1/2 11 +12 8 37 60 2 133303 R9012288 G1/1 0 + G3/ 180 +18 8 37 60 2 133300 R90122881 0 G2 00 +0 G1/2 11 +12 7 30 6 13330 R9012288 G2 00 +0 G3/ 180 +18 7 30 6 133301 R90122882 G2 00 +0 G1 3 +31 7 30 6 13330 13330 G2 00 +0 G1 1/2 0 + 0 7 32 6 133302 R90122883 RE 0171, edition: 16-03, Bosch Reroth AG

16/ HAB Bladder-type accumulator Spare parts and accessories (dimensions in mm) Pressure monitoring Adapter for pressure gauge, material number 1300171 Adapter G1/ ISO 228 1. deep Pressure gauge connection 7/8-1UNF Gas valve Spare part kit for gas valve Components Material number R90138300 Quantity 1 Protective cap 1 2 Sealing cap series 60 1 3 Valve insert series 60 1 Gas valve series 60 1 O-ring 1 6 Nut 1 1 2 3 6 Bosch Reroth AG, RE 0171, edition: 16-03

Bladder-type accumulator HAB 17/ Spare parts (dimensions in mm) Seal kit (position 1 ) Accumulator size Material number NBR, HNBR, ECO Material number FKM 1L R90119 2. 6L R9011921 0L R9011922 R9011923 30 7/8 1 UNF-1A 1/2 UNF-2B Ø7.70.79 (ISO 70 : 8V1) 1 2 3 Accumulator 30 size Spare bladder with gas valve and seal kit Holding ring Oil valve kit consisting of Material number Material number holding ring and oil valve NBR ECO FKM HNBR NBR, HNBR, FKM ECO 1 l R901370 R9013820 R90138280 R90138290 2. l R901371 R9013821 R90138280 R90138290 l R901372 R9013823 R9013822 R90138280 R90138290 R90138270 6 l R901373 R9013823 R90138280 R90138290 R90138270 l R90137 R9013823 R9013820 R901382 R90138281 R90138291 R90138271 l R90137 R9013821 R901382 R90138281 R90138291 R90138271 2 l R901376 R9013826 R90138281 R90138291 R90138271 32 l R901377 R90138236 R9013822 R9013827 R90138281 R90138291 R90138271 0 l R901378 R9013823 R9013828 R90138281 R90138291 R90138271 RE 0171, edition: 16-03, Bosch Reroth AG

18/ HAB Bladder-type accumulator Important notices Intended use Reroth bladder-type accumulators type HAB..-6X are intended for the set-up of hydraulic drive systems in stationary mechanical engineering and plant construction. In mobile applications or applications in which acceleration forces are applied to the bladder-type accumulator during intended use, its use is permitted only following release by the competent Reroth product manager. Please contact technical sales for this. Reroth bladder-type accumulators type HAB..-6X are not intended for private use. Project planning information Bladder-type accumulators have to be safely and permanently fastened to the machine or system using mounting elements. The fastening is intended to keep the oil port tension-free. Particularly, no tension forces or static or dynamic inertia forces should be applied to the oil port. Thermal epansion of the supporting structure and vibrations originating from the environment should be considered in the selection of suitable mounting points. Legal provisions Hydraulic accumulators are pressure vessels and subject to the application national provisions and/or regulations valid at the place of installation. In Germany, the Ordinance on Industrial Safety and Health (BetrSichV) applies. Special regulations are to be observed in shipbuilding, aircraft construction, mining, etc. Authorized persons According to Ordinance on Industrial Safety and Health (BetrSichV), only authorized persons may carry out tests. Authorized persons are such persons having obtained the required epert knowledge through professional training, eperience and recent professional activity. Safety instructions for hydraulic accumulators For the hydraulic accumulator type HAB..-6X, observe the operating instructions 0171-B. The machine end-user will have sole responsibility for compliance. General notices for hydraulic accumulators in hydraulic system can be found in ISO 13. Keep all documents included in the delivery in a safe place; they will be required by the epert in recurring tests. Safety equipment Notice: Hydraulic accumulators have to be secured against operation outside of the admissible limits according to Pressure Equipment Directive 1/68/EU. In order not to eceed the maimum operating pressure, we recommend the use of an accumulator shut-off block type ABZSS according to data sheet 0131. Bosch Reroth AG, RE 0171, edition: 16-03

Bladder-type accumulator HAB 19/ Further information Operating instructions valid for HAB1 HAB0 Language Operating Document number instructions German RD0171-B RA60062 English RE0171-B RA6006 French RF0171-B RA60063 Spanish RS0171-B RA6009 Italian RI0171-B RA60061 Chinese RC0171-B RA6006 Russian R-RS0171-B RA600 Norwegian R-NO0171-B RA6008 Polish R-PL0171-B RA60066 Czech R-CZ0171-B RA6006 Romanian R-RU0171-B RA60067 Hungarian RU0171-B RA6007 Portuguese RP0171-B RA60060 Swedish R-SK0171-B RA692909 CE Declarations of Conformity In German, English, French Type Document number HAB1-330... HAB2,-330... RA6313071 HAB-330... HAB6-330... HAB1-30... HAB2,-30... RA6313069 HAB-30... HAB6-30... HAB-330... RA6313070 HAB-330... HAB2-330... HAB32-330... HAB0-330... Accumulator shut-off block Data sheet 0131 Selection of filters www.boschreroth.com/filter Information on available spare parts www.boschreroth.com/spc RE 0171, edition: 16-03, Bosch Reroth AG

/ HAB Bladder-type accumulator Notes Bosch Reroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +9 (0) 93 2 / 18-0 documentation@boschreroth.de www.boschreroth.de This document, as well as the data, specifications and other information set forth in it, are the eclusive property of Bosch Reroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Bosch Reroth AG, RE 0171, edition: 16-03