New. High Performance Inverter FUJI INVERTERS 24A1-E-0042

Similar documents
Fuji Electric High Performance Compact Inverter. Single-phase 200 V kw Three-phase 400 V kw

Instruction Manual. Fuji Electric Co., Ltd.

AC Drive for Elevator

General Specifications

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

3 Year. Warranty. Maximum Engineering for Global Advantage. The High Performance Multifunctional Inverter CEN-G1EN18.05

3-phase 400 V 0.4 to 630 kw. High Performance Multifunctional Inverter

FRENIC-Mega Series of High-performance Multi-function Inverters

Solar. Fuji Electric Asia Pacific Pte. Ltd. Solar (PV) Pumping Inverter

Frequency Inverters SJ Series Type P1

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Powerdrive FX Ultra compact regenerative drive solution

Instruction Manual Fuji Electric Co., Ltd. INR-SI c-E

J1000. Compact Inverter Series.

V1000. Inverter Series.

V1000 Inverter Series

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

Instruction Manual Fuji Electric Co., Ltd. INR-SI E

SYSDrive Frequency Inverter

Unidrive M700 Class leading performance with onboard real-time Ethernet

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

The Fuji Cabinet Solution

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Delta Products VFD CP2000 Bypass Control Packages.

L300P Inverter Specifications

Cabinet-built single drives, ACS880-07

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

VSD Series II Variable Speed Micro Drives

Powerdrive FX Ultra compact regenerative drive solution

Symbol Input rating Symbol 2 Three-phase, 200 ~ 230V N 4 Three-phase, 380 ~ 480V. None. Loader. Graphic. Loader

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Industrial Inverter (For 3-phase motors)

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

SD1 Series General Purpose AC Variable Speed Drives


Frequency inverters overview

High performance Vector Control. Ratings. System configuration

V1000 DE ES FR IT V1000 V1000 V1000 V1000

ADJUSTABLE FREQUENCY CRANE CONTROLS

SJ300 Inverter Specifications

LSLV High-Performance Standard Drive 0.4~2.2kW 1-Phase 200~240Volts 0.4~15kW 3-Phase 200~240Volts 0.4~75kW 3-Phase 380~480Volts

A1000 D E A1000 A1000 A1000 A1000

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Quick Start Guide of CV50- ControlVIT Series

V1000. AC Drive Series.

VFD E Series. Features

English.

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

High on intelligence big on reliability AC Drive

Shenzhen Sine Electric Co., Ltd.

Lexium integrated drives

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

INVERTER SERIES HIGH PERFORMANCE VECTOR CONTROL A1000

Technical Explanation for Inverters

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive

Topology. Topology of System

VG7. System Application Drive. Drives for every industry

LIFT INVERTER SERIES L1000A

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Liquid cooled heavy duty converter

SSW07. Soft Starters. Applications. Standard Features

SMS PRODUCT CATALOGUE

up to 63 A (1 module per pole)

HVW701 HVAC Drive with By-Pass

Technical Data Sheets

RVS-DN Digital Reduced Voltage Motor Starter

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

INVEOR "Smart connections." on five levels

FE100/FE200. Inverter

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Delta Fan/Pump Vector Control Drive CP2000 Series

USB Copy Unit COM ERR. Copy. RJ-45 / USB Adapter. Verify. Read LOCK YASKAWA JVOP-181. Remote Operator Extansion Cable. Communication Option Board

Phase + Neutral, neutral on left side

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

GS2 Series - Introduction

DX³ RCCBs - ID 4P up to 100 A

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Starting guide FRENIC-Lift

LV Capacitor Bank APC

825-P Modular Protection System for motors Specification Guide

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Phase + Neutral, neutral on right side

MX1S Matrix Converter

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Customized drive solutions

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Transcription:

High Performance Inverter New FUJI INVERTERS The FRENIC-Ace is the inverter that produces excellent cost-performance; maintains high performance through optimal design. In this way, it can be applied to various machines and devices. 24A1-E-0042

The next generation inverter has arrived Introducing our New Standard Inverter! Enjoy a full range of applications The standard inverter for the next generation, the FRENIC-Ace, can be used in almost any type of applicationfrom fans and pumps to specialized machinery. 3-phase 400V series Nominal applied motor [kw] Model rating Rated output current Model rating Rated output current H rating Rated output Model current rating Rated output Model current 18.5 39A 22 A A A 59A 60A 60A 60A 72A A A A 85A 91A 91A 91A 105A 112A 112A 112A 139A 150A 150A 150A 168A 176A 176A 110 203A Rating condition Overload current rating 120% -1min Max. ambient temp. 40 Overload current rating 150% -1min Max. ambient temp. 40 Overload current rating 120% -1min Max. ambient temp. 50 Overload current rating 150% -1min, 200% -0.5sec Max. ambient temp. 50 Fans, pumps Application Wire drawing Vertical conveyance Winding machines Printing machines Note: The 3-phase 400V 0.1-15 kw, 132 kw - 220 kw, 3-phase 200V series, and single-phase 200V will be coming soon.

OPEN FUJI INVERTERS Type How to read the model number Series name FRN FRENIC Series Standard motor (kw) Code 0059 0072 0085 0105 0139 0168 0203 110 22 H 22 18.5 22 Destination, specialty items C A E China Asia Europe External diagram Fig. A Fig. B MAX.W W1 MAX.D 40 W2 40 D3 H 11 8 11 8.3 W 12 12 32.6 66.8 41.4 N M D D2 10 H H1 25 25 12 H2 8 246.2 61.3 66.8 147.2 41.4 N M 3.1 6 D1 D2 4 4 M8 252 226 4 M8 312 288 418.5 8 205 243 19 357 (41) 417 8 MAX.W3 W4 8 240 512 9 5 Series Inverter type Fig Dimensions (mm) W W1 W2 W3 W4 H H1 H2 D D1 D2 D3 M N A 250 400 195 105 Three-phase 400V 326.2 320 240 310.2 4 0 5 500 261 140 2 2 10 10 B 615 595 565 115 361.2 3 2 3.2 339 6 6 625 276 1 270 740 720 6

FUJI INVERTERS Customizable logic Customizable logic function is available as a standard feature. FRENIC-Ace has built-in customizable logic functions with a maximum of 100 steps* including both digital and analog operation functions, giving customers the ability to customize their invertersfrom simple logic functions to full-scale programming. Fuji also has plans to offer programming templates for wire drawing machines, hoists, spinning machines, and other applications so that the FRENIC-Ace can be used as a dedicated purpose inverter. Example: Hoist crane application Programming the FRENIC-Ace main unit with the required logic for controlling a hoist (1) Set speed program (2) Reset the alarm by using the push-button switch (3) Mechanical limit switch function (4) Detect load (5) Automatic speed drive when no load is detected Dedicated/specialized functions for hoist application implemented by using customizable logic (6) Overload stop function * 200 steps planned for upcoming version upgrade Superior flexibility (coming soon) FRENIC-Ace has readily available interface cards and various types of fieldbus / network to maximize its flexibility. Option Installation type RJ- connector PG interface (5V) card PG interface (12/15V) card control terminal block Control terminal block DeviceNet communication card CC-Link communication card PROFIBUS-DP communication card EtherNet/IP communication card ProfiNet-RT communication card CANopen communication card Digital input/output interface card Analog input/output interface card Front face panel front face keypad mount kw(): option card is built-in Wide variety of functions as a standard feature Sensorless dynamic torque vector control Motor vector control with PG coming soon / with optional card Synchronous motor with sensorless vector control coming soon 2-channel on-board RS485 communications port Standard CANopen compatibility Removable keypad device Removable control terminal block board

FUJI INVERTERS Multi-function keypad (option) FRENIC-Ace has two different multi-function keypads available Multi-function keypad with LCD display: Enhanced HMI functionality (coming soon) USB keypad: Connect to a computer for more efficient operation (set-up, troubleshooting, maintenance, etc) LAN cable USB USBminiB cable Multi-function keypad with LCD screen USB keypad Functional Safety FRENIC-Ace is equipped with STO functional safety function as a standard. Therefore output circuit magnetic contactors are not required for safe stop implementation. Enhanced standard features position FRENIC-Ace ahead of its class (Safety input: 2CH, output: 1CH). Complies with (coming soon) EN ISO 13849-1: 2008, Cat.3 / PL=e IEC/EN 60204-1: 2005/2006 Stop category 0 IEC/EN 61508-1 to -7: 2010 SIL3 IEC/EN 61800-5-2: 2007 SIL3 (Safety feature: STO) IEC/EN 62061: 2005 SIL3 10 years lifetime design FRENIC-Ace components have a design life of ten years. A longer maintenance cycle also helps to reduce running costs. Design life Main circuit capacitor Electrolytic capacitors on PCB Cooling fan Ambient temperature Life conditions Load rate * specifications have a rated current of two sizes higher than specifications, so the life is 7 years. 10 years* 10 years* 10 years* +40 C (104 F) 100% ( specifications) 80% (H// specifications) Standards RoHS Directive Standard compliance with European regulations that limit the use of specific hazardous substances (RoHS) Global compliance Standard compliance (cominng soon) <Six hazardous substances> Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), polybrominated biphenyl ether (PBDE) Europe EC Directives (CE Mark) North America/Canada UL Standard (cul Certified) <About RoHS> Directive 2002/95/EC, issued by the European Parliament and European Council, limits the use of specific hazardous substances in electrical and electronic devices.

FUJI INVERTERS Basic wiring diagram Standard terminal block board model Motor (when cooling fan is installed) Transformer Thermal relay FU FV FW FM (G) Braking resistor (option) 2 (CM) 1 P DB MCCB or ELCB Magnetic contactor (MC) DC REACTOR (option) P1 Braking resistor (option) (G) 2 (CM) 1 P DB (THR) P(+) DB N(-) (G) P(+) R P(+) P(+) DB 2 1 (THR) N(-) Braking unit BU (option) N(-) Thermal relay Motor 400V series 380V to 480V 50/60Hz L1/R L2/S L3/T R C F U V W U V W M 3~ Control power AUX input Fan power AUX input Ground terminal R0 T0 R1 T1 G Charge lamp DC/DC Power voltage switching connector "CN UX" Fan power connector "CN R" / "CN W" G to [C1] to [11] Ground terminal PTC Thermistor TH1 THC E C +24VDC 0V RJ connector B A Alarm relay output (for any fault) (A, B, C) Relay output Safety signal (EN1) (EN2) Keypad SW2 Data send/receive (RS-485) Option connector Forward operation and stopping command Reverse operation and stopping command (PLC) SINK (PLC) SW1 SOURCE (FWD) (REV) Removable terminal block <Y2> <Y1> <CMY> Transistor output 2 [OL] motor overload warning Transistor output 1 [RUN] running Transistor output common Transistor output Digital input 1 [SS1] Multistep speed selection Digital input Digital input 2 [SS2] Multistep speed selection Digital input 3 [SS4] Multistep speed selection Digital input 4 [BX] Coast-to-stop command Digital input 5 [RST] Alarm (error) reset Digital input common Analog input Voltage input for speed setting Current input for speed setting 3 2 1 (+) (-) (X1) (X2) (X3) (X4) (X5) (CM) +10VDC [13] Voltage input 12 (0 to +10 VDC) [12] (0 to ±10 VDC) 0V [11] AI PTC SW4 Current input C1 (4 (0) to 20 madc) V2 [C1] PTC thermistor input Voltage input V2 C1 (0 to +10 VDC) SW3 0V Current output FMI (4 (0) to 20 madc) Voltage output (0 to +10 VDC) Pulse output FMV FMP [FM] (25 to 32 kp/s) SW5 SW6 SW6 [11] 0V DX+ DX- CAN+ CAN- RJ connector Analog output/pulse output [Fout1] output frequency (prior to slip compensation) Analog output common Data send/receive (RS-485) (CAN-BUS) Analog pulse output NOTE This wiring diagram is to be used as a reference only when using standard terminal block model. When wiring your inverter and/or before applying power, please follow always the connection diagrams and the relevant information written in the User's Manual.

FUJI INVERTERS Standard specifications Item Type FRN E2S-4 Nominal applied motor [kw] (*1) H Rated capacity [kva] (*2) H Voltage [V] (*3) Output rating Rated current [A] (*4) H Overload current rating, H Main power (phase, voltage, frequency) Voltage/frequency variation Rated current (no DCR) [A] (*5) H Input power Rated current (with DCR) [A] (*5) H Required power supply capacity H (with DCR) [kva] (*6) Braking torque [%] (*7) H Braking DC braking Braking transistor Braking resistor DC reactor (DCR), H Protective structure (IEC60529) Cooling system Weight [kg] Specifications 0059 0072 0085 0105 0139 0168 0203 110 22 22 18.5 22 65 80 106 128 1 34 46 57 69 85 114 134 34 46 57 69 85 114 134 34 46 57 69 85 114 Three-phase 380 480V (with AVR function) 59.0 72.0 85.0 105 139 168 203.0 60.0.0 91.0 112 150 176.0 60.0.0 91.0 112 150 176 39.0.0 60.0.0 91.0 112 150 150% of rated output current -1 min 120% of rated output current -1 min 150% of rated output current -1 min, 200% -0.5s 3-phase 380 to 480V, 50Hz/60Hz 3-phase 380 to 440V, 50Hz 3-phase 380 to 480V, 60Hz Voltage: +10 to -15% (Voltage unbalance: 2% or less (*7)), Frequency: +5 to -5% 77.9 94.3 114 140 60.6 77.9 94.3 114 140 60.6 77.9 94.3 114 140 52.3 60.6 77.9 94.3 114 140 57.0 68.5 83.2 102 138 164 201 42.2 57.0 68.5 83.2 102 138 164 42.2 57.0 68.5 83.2 102 138 164 35.5 42.2 57.0 68.5 83.2 102 138 39 47 58 71 96 114 139 29 39 47 58 71 96 114 29 39 47 58 71 96 114 25 29 39 47 58 71 96 12% 5 to 9% 15% 7 to 12% 15% 7 to 12% 20% 10 to 15% Starting frequency: 0.1 to 60.0Hz, Braking time: 0.0 to.0s, Braking level: 0 to 100% ( specifications), 0 to 80% (/ specifications), 0 to 60% ( specifications) Built-in Standard Standard Standard IP20 closed type, UL open type IP00 open type, UL open type Fan cooled 9.5 10 25 26 33 40 *1 Nominal applied motor refers to the use of a Fuji Electric 4-pole standard motor. *2 Rated capacity refers to 440V rating *3 Output voltage cannot exceed the power supply voltage. *4 Must be reduced if carrier frequency (function code F26) is higher than the following settings. /: Model or higher 4 khz H: Model ; 10kHz: to ; 6 khz, ; 4 khz : Model to FRN0168 E2S-4 ; 10kHz: FRN0203 E2S-4 ; 6 khz *5 With a power supply of 500 kva (if the inverter capacity is over 50 kva, then 10 times inverter capacity), indicates the calculated value when connected to a %X=5% power supply. When the applied motor has a capacity of kw or higher, use a DC reactor. *6 When DC reactor is connected *7 Average braking torque value for the motor alone (varies depending on motor efficiency). *8 Voltage unbalance [%] = (Max. voltage [V] Min. voltage [V])/Three-phase average voltage [V] 67 (see IEC/EN 61800-3). Use AC reactor (ACR, optional) for unbalance rates between 2% and 3%.

When running general-purpose motors Driving a 400V general-purpose motor When driving a 400V general-purpose motor with an inverter using extremely long cables, damage to the insulation of the motor may occur. Use an output circuit filter (OFL) if necessary after checking with the motor manufacturer. Fuji's motors do not require the use of output circuit filters because of their reinforced insulation. Torque characteristics and temperature rise When the inverter is used to run a general-purpose motor, the temperature of the motor becomes higher than when it is operated using a commercial power supply. In the low-speed range, the cooling effect will be weakened, so decrease the output torque of the motor. If constant torque is required in the low-speed range, use a Fuji inverter motor or a motor equipped with an externally powered ventilating fan. Vibration When the motor is mounted to a machine, resonance may be caused by the natural frequencies, including that of the machine. Operation of a 2-pole motor at 60Hz or more may cause abnormal vibration. * Study use of tier coupling or dampening rubber. * It is also recommended to use the inverter jump frequencies control to avoid resonance points. Noise When an inverter is used with a general-purpose motor, the motor noise level is higher than that with a commercial power supply. To reduce noise, raise carrier frequency of the inverter. High-speed operation at 60Hz or more can also result in more noise. When running special motors Explosion-proof motors When driving an explosion-proof motor with an inverter, use a combination of a motor and an inverter that has been approved in advance. Brake motors For motors equipped with parallel-connected brakes, their braking power must be supplied from the primary circuit (commercial power supply). If the brake power is connected to the inverter power output circuit (secondary circuit) by mistake, problems may occur. Do not use inverters for driving motors equipped with series-connected brakes. Geared motors If the power transmission mechanism uses an oillubricated gearbox or speed changer/reducer, then continuous motor operation at low speed may cause poor lubrication. Avoid such operation. Single-phase motors Single-phase motors are not suitable for inverterdriven variable speed operation. Use three-phase motors. NOTES Environmental conditions Installation location Use the inverter in a location with an ambient temperature range of -10 to 50 C. The inverter and braking resistor surfaces become hot under certain operating conditions. Install the inverter on nonflammable material such as metal. Ensure that the installation location meets the environmental conditions specified in "Environment" in inverter specifications. Combination with peripheral devices Installing a molded case circuit breaker (MCCB) Install a recommended molded case circuit breaker (MCCB) or an earth leakage circuit breaker (ELCB) in the primary circuit of each inverter to protect the wiring. Ensure that the circuit breaker capacity is equivalent to or lower than the recommended capacity. Installing a magnetic contactor (MC) in the output (secondary) circuit If a magnetic contactor (MC) is mounted in the inverter's secondary circuit for switching the motor to commercial power or for any other purpose, ensure that both the inverter and the motor are fully stopped before you turn the MC on or off. Remove the surge killer integrated with the MC. Installing a magnetic contactor (MC) in the input (primary) circuit Do not turn the magnetic contactor (MC) in the primary circuit on or off more than once an hour as an inverter fault may result. If frequent starts or stops are required during motor operation, use FWD/REV signals. Protecting the motor The electronic thermal facility of the inverter can protect the general-purpose motor. The operation level and the motor type (general-purpose motor, inverter motor) should be set. For high-speed motors or water-cooled motors, set a small value for the thermal time constant to protect the motor. If you connect the motor thermal relay to the motor with a long cable, a high-frequency current may flow into the wiring stray capacitance. This may cause the relay to trip at a current lower than the set value for the thermal relay. If this happens, lower the carrier frequency or use the output circuit filter (OFL). Discontinuance of power-factor correcting capacitor Do not mount power factor correcting capacitors in the inverter (primary) circuit. Use a DC REACTOR to improve the inverter power factor. Do not use power factor correcting capacitors in the inverter output circuit (secondary). An overcurrent trip will occur, disabling motor operation. Discontinuance of surge killer Do not mount surge killers in the inverter output (secondary) circuit. Reducing noise Use of a filter and shielded wires are typical measures against noise to ensure that EMC Directives are met. Measures against surge currents If an overvoltage trip occurs while the inverter is stopped or operated under a light load, it is assumed that the surge current is generated by open/close of the phase-advancing capacitor in the power system. We recommend connecting a DC REACTOR to the inverter. Megger test When checking the insulation resistance of the inverter, use a 500V megger and follow the instructions contained in the Instruction Manual. Wiring Wiring distance of control circuit When performing remote operation, use twisted shielded wire and limit the distance between the inverter and the control box to 20m. Wiring length between inverter and motor If long wiring is used between the inverter and the motor, the inverter will overheat or trip as a result of overcurrent (due to high-frequiency current flowing into the stray capacitance). Ensure that the wiring is shorter than 50m. If this length must be exceeded, lower the carrier frequency or mount an output circuit filter (OFL). When wiring is longer than 50m, and sensorless vector control or vector control with speed sensor is selected, execute off-line tuning. Wiring size Select cables with a sufficient capacity by referring to the current value or recommended wire size. Wiring type Do not use multicore cables that are normally used for connecting several inverters and motors. Grounding Securely ground the inverter using the grounding terminal. Selecting inverter capacity Driving general-purpose motor Select an inverter according to the applicable motor ratings listed in the standard specifications table for the inverter. When high starting torque is required or quick acceleration or deceleration is required, select an inverter with a capacity one size greater than the standard. Driving special motors Select an inverter that meets the following condition: Inverter rated current > Motor rated current. Transportation and storage When transporting or storing inverters, follow the procedures and select locations that meet the environmental conditions according to the inverter specifications. Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan Phone: +81-3-5435-7057 Fax: +81-3-5435-7420 URL: http://www.fujielectric.com/ Printed in Japan 2013-02(B13/B13)CM 20 FOLS