Cam switches 3. General 3. Complete switches. Ø 16 or Ø 22 hole fixing

Similar documents
K50H004UP cam changeover switch - 4-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

XACA871 pendant control station XAC-A - 8 pushbuttons

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

Pendant control stations 6

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Limit switches 3. Page 92. Page 92

AF40... AF96 3-pole contactors Technical data

Limit Switch - Prewired Type Metal Body

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

FL series position switches


Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

Position switches FD series

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

FOOT SWITCHES

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

LR-LX-LK-LW Safety Switches with separate actuator

Limit Switches - Limit Type (PS21L) Metal Body IP66

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

ASL09..S 3-pole Contactors - Spring Terminals

Rotary limit switches FCR FGR series

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Pendant control stations

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Compact plastic limit switches with positive opening mechanism

XACA871 pendant control station XAC-A - 8 pushbuttons

Safety switches with separate actuator

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

Modular contactors and relays

SFS-UFS Single Foot Switches

Compact plastic limit switches with positive opening mechanism

Miniaturized limit switches

Cylindrical fuse-link

Comepi Limit Switches

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

Safety switches for hinged doors

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

PV DC Isolator Switches

Special Purpose Fuses

MS General Information Extended Product Type: MS

Limit Switches - Limit Type Plastic Body IP65

General_technical_data Series

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Pre wired limit switches

Limit Switches - Limit Type Plastic Body IP65

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Limit Switches - Limit Type (PS31L) Plastic Body IP65

MANUALLY OPERATED CHANGEOVER SWITCHES

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Cam Switch. Rish Cam 16A Rish Cam 32A Rish Cam 100A. Rish Cam 10A Rish Cam 25A Rish Cam 63A Rish Cam 200A. Rish Cam 6A Rish Cam 20A Rish Cam 40A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Safety Limit Switches

3 - Protection components Motor circuit-breakers

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Safety rope switch with reset for emergency stop

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Vistop TM isolating switches 63 to 160A

LK Position Switches TECHNICAL DATASHEET.

Switch Disconnectors

Safety switches for hinged doors

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Screw limit switches XRBA and XR2. Catalogue

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Safety rope switches with reset for emergency stop

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Motorized switch-disconnectors OTM 40 to 125 Amperes

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

Transcription:

General Cam switches Complete switches, A The range K cam switches ( A rating) comprises only complete switches. These products are more specifi cally designed for process control applications: b compact size, b easy to integrate with other Ø Ø mm units, b selection functions. Complete switches Front mounting b switches b stepping switches b reversing switch b changeover switches b voltmeter switches b ammeter switches By Ø. or Ø. mm hole Mounting Ø or Ø hole fixing Locking/unlocking the body-head assembly by spigot Ø hole fixing Ø hole fixing page -EN/ s: page -EN/ page -EN/ -EN_Ver..indd

Characteristics Cam switches Complete switches, A Front mounting by Ø or Ø mm hole With x mm front plate Environment Conformity to stards EN/IEC - EN/IEC -- UL Product certifications culus Protective treatment Stard version: TC Ambient air temperature For operation: - + C For storage: - + C Electric shock protection Class II, conforming to IEC Degree protection Mechanical life IP conforming to IEC (operating head) IP (contact block) million operating cycles Contact block characteristics Rated operational characteristics AC-, A V A V A AC-A, AC- V A Short-circuit protection UL/Canada Heavy Duty A -phase / V. hp / V hp single-phase / V. hp / V. hp AC-A -phase / V. kw single-phase / V. kw / V. kw d.c. current Ie resistive load A cartridge fuse type gg contact V A V. A V. A Conventional thermal current (Ith) A Rated insulation voltage (Ui) V, degree pollution, conforming to IEC - Contact operation Slow break Terminal referencing Conforming to EN Rated impulse withst voltage (U imp) kv conforming to IEC - Electrical reliability Connection Failure rate < fault for million operating cycles (c V PLC inputs) Captive screw clamp terminals Clamping capacity: x. mm page -EN/ s: page -EN/ page -EN/ -EN_Ver..indd

s Cam switches Complete switches, A Front mounting by Ø or Ø mm hole With x mm front plate Switches with switching angle switch poles K BACH K AACH. K BACH. -pole -pole -pole -pole K CACH. K DACH. Stepping switches, single-pole, with switch steps L + K BQCH. L + K CQCH. K DQCH L + K DQCH. page -EN/ page -EN/ page -EN/ -EN_Ver..indd

s (continued) Cam switches Complete switches, A Front mounting by Ø or Ø mm hole With x mm front plate Stepping switches, -pole, with switch steps K DQCH L L + K DQCH. L L + K FQCH. Stepping switches, single-pole, without L K CNCH. L K DNCH. page -EN/ page -EN/ page -EN/ -EN_Ver..indd

s (continued) Cam switches Complete switches, A Front mounting by Ø or Ø mm hole With x mm front plate Stepping switch, -pole, without switch steps L L K FNCH. Changeover switch with spring return to switch poles L L K BTCH. K BTCH page -EN/ page -EN/ page -EN/ -EN_Ver..indd

s (continued) Cam switches Complete switches, A Front mounting by Ø or Ø mm hole With x mm front plate Changeover switches with switch poles K FUCH L/ -pole -pole -pole -pole K BUCH. K DUCH. K FUCH. K HUCH. Changeover switches without L/ -pole -pole -pole -pole K BUCH. K DUCH. K FUCH. K HUCH. page -EN/ page -EN/ page -EN/ -EN_Ver..indd

s (continued) Cam switches Complete switches, A Front mounting by Ø or Ø mm hole With x mm front plate Voltmeter switches For measurements between phases between phase neutral switch L L L N L-L L-N L-L L-N L-L L-N K FMCH. K FMCH V For measurements between phases, with L L L V L-L L-L L-L K DMCH. Ammeter switches For circuits, with K FMCH L L L PE A K FMCH. page -EN/ page -EN/ page -EN/ -EN_Ver..indd

Dimensions Cam switches Complete switches, A Front mounting by Ø or Ø mm hole With x mm front plate Cam switches, A e a a K A, B K C, D K F K H e: support panel thickness. to mm. Ø Ø mm panel cut-outs,,,,,, Convention used for representation Link s (factory mounted) Graphic representation switching s spring return to L L L Contact terminal reference number U V W Contact closed Contact closed in s maintained between the s Angular switch Sealed assembly for auto-maintain control Overlapping contacts page -EN/ page -EN/ s: pages -EN/ to -EN/ -EN_Ver..indd